1.
Sensors (Basel) ; 18(11)2018 Oct 24.
Article in English | MEDLINE | ID: mdl-30355993

ABSTRACT

Point cloud registration plays a key role in three-dimensional scene reconstruction, and determines the effect of reconstruction. The iterative closest point algorithm is widely used for point cloud registration. To improve the accuracy of point cloud registration and the convergence speed of registration error, point pairs with smaller Euclidean distances are used as the points to be registered, and the depth measurement error model and weight function are analyzed. The measurement error is taken into account in the registration process. The experimental results of different indoor scenes demonstrate that the proposed method effectively improves the registration accuracy and the convergence speed of registration error.

2.
Sensors (Basel) ; 16(10)2016 Sep 27.
Article in English | MEDLINE | ID: mdl-27690023

ABSTRACT

Gait phase is widely used for gait trajectory generation, gait control and gait evaluation on lower-limb exoskeletons. So far, a variety of methods have been developed to identify the gait phase for lower-limb exoskeletons. Angular sensors on lower-limb exoskeletons are essential for joint closed-loop controlling; however, other types of sensors, such as plantar pressure, attitude or inertial measurement unit, are not indispensable.Therefore, to make full use of existing sensors, we propose a novel gait phase recognition method for lower-limb exoskeletons using only joint angular sensors. The method consists of two procedures. Firstly, the gait deviation distances during walking are calculated and classified by Fisher's linear discriminant method, and one gait cycle is divided into eight gait phases. The validity of the classification results is also verified based on large gait samples. Secondly, we build a gait phase recognition model based on multilayer perceptron and train it with the phase-labeled gait data. The experimental result of cross-validation shows that the model has a 94.45% average correct rate of set (CRS) and an 87.22% average correct rate of phase (CRP) on the testing set, and it can predict the gait phase accurately. The novel method avoids installing additional sensors on the exoskeleton or human body and simplifies the sensory system of the lower-limb exoskeleton.

SELECTION OF CITATIONS
SEARCH DETAIL
...