Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Eng Online ; 23(1): 57, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38902671

ABSTRACT

OBJECTIVE: Our objective was to create a machine learning architecture capable of identifying obstructive sleep apnea (OSA) patterns in single-lead electrocardiography (ECG) signals, exhibiting exceptional performance when utilized in clinical data sets. METHODS: We conducted our research using a data set consisting of 1656 patients, representing a diverse demographic, from the sleep center of China Medical University Hospital. To detect apnea ECG segments and extract apnea features, we utilized the EfficientNet and some of its layers, respectively. Furthermore, we compared various training and data preprocessing techniques to enhance the model's prediction, such as setting class and sample weights or employing overlapping and regular slicing. Finally, we tested our approach against other literature on the Apnea-ECG database. RESULTS: Our research found that the EfficientNet model achieved the best apnea segment detection using overlapping slicing and sample-weight settings, with an AUC of 0.917 and an accuracy of 0.855. For patient screening with AHI > 30, we combined the trained model with XGBoost, leading to an AUC of 0.975 and an accuracy of 0.928. Additional tests using PhysioNet data showed that our model is comparable in performance to existing models regarding its ability to screen OSA levels. CONCLUSIONS: Our suggested architecture, coupled with training and preprocessing techniques, showed admirable performance with a diverse demographic dataset, bringing us closer to practical implementation in OSA diagnosis. Trial registration The data for this study were collected retrospectively from the China Medical University Hospital in Taiwan with approval from the institutional review board CMUH109-REC3-018.


Subject(s)
Electrocardiography , Machine Learning , Signal Processing, Computer-Assisted , Sleep Apnea Syndromes , Humans , Male , Middle Aged , Sleep Apnea Syndromes/diagnosis , Female , Adult , Aged , Sleep Apnea, Obstructive/diagnosis , Sleep Apnea, Obstructive/physiopathology
3.
Front Cardiovasc Med ; 9: 1001982, 2022.
Article in English | MEDLINE | ID: mdl-36312246

ABSTRACT

Objective: To implement an all-day online artificial intelligence (AI)-assisted detection of ST-elevation myocardial infarction (STEMI) by prehospital 12-lead electrocardiograms (ECGs) to facilitate patient triage for timely reperfusion therapy. Methods: The proposed AI model combines a convolutional neural network and long short-term memory (CNN-LSTM) to predict STEMI on prehospital 12-lead ECGs obtained from mini-12-lead ECG devices equipped in ambulance vehicles in Central Taiwan. Emergency medical technicians (EMTs) from the 14 AI-implemented fire stations performed the on-site 12-lead ECG examinations using the mini portable device. The 12-lead ECG signals were transmitted to the AI center of China Medical University Hospital to classify the recordings as "STEMI" or "Not STEMI". In 11 non-AI fire stations, the ECG data were transmitted to a secure network and read by available on-line emergency physicians. The response time was defined as the time interval between the ECG transmission and ECG interpretation feedback. Results: Between July 17, 2021, and March 26, 2022, the AI model classified 362 prehospital 12-lead ECGs obtained from 275 consecutive patients who had called the 119 dispatch centers of fire stations in Central Taiwan for symptoms of chest pain or shortness of breath. The AI's response time to the EMTs in ambulance vehicles was 37.2 ± 11.3 s, which was shorter than the online physicians' response time from 11 other fire stations with no AI implementation (113.2 ± 369.4 s, P < 0.001) after analyzing another set of 335 prehospital 12-lead ECGs. The evaluation metrics including accuracy, precision, specificity, recall, area under the receiver operating characteristic curve, and F1 score to assess the overall AI performance in the remote detection of STEMI were 0.992, 0.889, 0.994, 0.941, 0.997, and 0.914, respectively. During the study period, the AI model promptly identified 10 STEMI patients who underwent primary percutaneous coronary intervention (PPCI) with a median contact-to-door time of 18.5 (IQR: 16-20.8) minutes. Conclusion: Implementation of an all-day real-time AI-assisted remote detection of STEMI on prehospital 12-lead ECGs in the field is feasible with a high diagnostic accuracy rate. This approach may help minimize preventable delays in contact-to-treatment times for STEMI patients who require PPCI.

4.
J Med Biol Eng ; 41(5): 659-668, 2021.
Article in English | MEDLINE | ID: mdl-34512223

ABSTRACT

PURPOSE: Sleep is an important human activity. Comfortable sensing and accurate analysis in sleep monitoring is beneficial to many healthcare and medical applications. From 2020, owing to the COVID­19 pandemic that spreads between people when they come into close physical contact with one another, the willingness to go to hospital for receiving care has reduced; care-at-home is the trend in modern healthcare. Therefore, a home-use and real-time sleep-staging system is developed in this paper. METHODS: We developed and implemented a real-time sleep staging system that integrates a wearable eye mask for high-quality electroencephalogram/electrooculogram measurement and a mobile device with MobileNETV2 deep learning model for sleep-stage identification. In the experiments, 25 all-night recordings were acquired, 17 of which were used for training, and the remaining eight were used for testing. RESULTS: The averaged scoring agreements for the wake, light sleep, deep sleep, and rapid eye movement stages were 85.20%, 87.17%, 82.87%, and 89.30%, respectively, for our system compared with the manual scoring of PSG recordings. In addition, the mean absolute errors of four objective sleep measurements, including sleep efficiency, total sleep time, sleep onset time, and wake after sleep onset time were 1.68%, 7.56 min, 5.50 min, and 3.94 min, respectively. No significant differences were observed between the proposed system and manual PSG scoring in terms of the percentage of each stage and the objective sleep measurements. CONCLUSION: These experimental results demonstrate that our system provides high scoring agreements in sleep staging and unbiased sleep measurements owing to the use of EEG and EOG signals and powerful mobile computing based on deep learning networks. These results also suggest that our system is applicable for home-use real-time sleep monitoring.

SELECTION OF CITATIONS
SEARCH DETAIL
...