1.
J Clin Sleep Med ; 19(5): 941-946, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36722607

ABSTRACT

STUDY OBJECTIVES: To evaluate for potential interactions between magnetic positive airway pressure (mPAP) masks and cardiac implantable electronic devices (CIEDs) for patients with sleep apnea. METHODS: Adult patients with a CIED who used an mPAP mask were recruited from our sleep clinic to undergo a safety visit at our pacemaker clinic. We tested whether the mPAP interacted with the implanted device at home during normal use and in the clinic during simulated normal use and with direct contact. The magnetic field strength of 6 mPAP masks was tested with a gaussmeter. RESULTS: Of 13 patients tested, 1 (8%), wearing a full face mask (ResMed AirFit F30 [ResMed, San Diego, California]), had a magnet response event (interaction) with direct contact, but no interactions were identified during normal or simulated normal use in any patient. The magnetic field strength of the mPAP masks increased the closer the mask got to the CIED, from 0.4 mT (4 G) at the mask manufacturer's recommended 5.1-cm (2-inch) distance from an implanted medical device up to 291 mT (2,910 G) at 0 cm (0 inches; direct contact). CONCLUSIONS: An mPAP mask may interact with a CIED if placed directly on the skin overlying the CIED. The use of Philips Respironics (Philips, Cambridge, Massachusetts) mPAP masks is now contraindicated in patients with a CIED. Until additional studies are conducted to better document the risks and benefits of mPAP masks, we recommend discouraging patients with CIEDs from using any mPAP mask. CITATION: Ruoff CM, Tashman YS, Cheema KPK, et al. Interaction of positive airway pressure mask magnets with cardiac implantable electronic devices. J Clin Sleep Med. 2023;19(5):941-946.


Subject(s)
Magnets , Sleep Apnea Syndromes , Adult , Humans , Prostheses and Implants
2.
Sleep Med ; 102: 142-146, 2023 02.
Article in English | MEDLINE | ID: mdl-36652893

ABSTRACT

OBJECTIVE/BACKGROUND: Home sleep apnea tests utilizing peripheral arterial tone (PAT HSAT) detect sleep disordered breathing by measuring various physiologic measures including changes in arterial volume in the finger. Validation tests comparing PAT HSAT to simultaneous polysomnography (PSG) have demonstrated a high correlation. Alcohol increases peripheral vasodilation, which may alter arterial tone in the finger. Validation studies have not evaluated for an interaction between alcohol consumption and PAT HSAT measures. PATIENTS/METHODS: We describe an in-depth evaluation of a 53-year-old man who consumes alcohol on nightly basis. He underwent a series of 5 diagnostic studies under different conditions: three PAT HSATs (two nights with and another without alcohol) and two polysomnograms (one night with and another without alcohol). RESULTS: Obstructive sleep apnea (OSA) was found on both polysomnograms but only on the PAT HSAT without alcohol, raising the possibility of two false negative PAT HSAT results after alcohol consumption. CONCLUSIONS: This report demonstrates the need for further investigations into the performance of PAT HSATs with and without alcohol. In the meantime we recommend that testing be done without alcohol and over the course of multiple nights.


Subject(s)
Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Male , Humans , Middle Aged , Sleep Apnea Syndromes/diagnosis , Sleep Apnea, Obstructive/diagnosis , Sleep , Polysomnography/methods , Alcohol Drinking/adverse effects