1.
Anal Chem ; 93(30): 10519-10527, 2021 08 03.
Article in English | MEDLINE | ID: mdl-34282898

ABSTRACT

The last decade has seen widespread adoption of triple quadrupole-based inductively coupled plasma-tandem mass spectrometry (ICPMS/MS) technique using a collision/reaction cell in combination with a precell bandpass mass analyzer to measure isotopes otherwise masked by spectral interferences. High-precision isotope ratio analysis containing such isotopes would benefit from a similar capability on a multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) platform, but using a quadrupole-based precell mass analyzer for MC-ICPMS/MS has several limitations. To overcome these limitations, we developed a novel precell mass analyzer for MC-ICPMS/MS using sector field technology. The new precell mass analyzer, comprising two Wien filters and a selection aperture, and a hexapole collision/reaction cell were integrated together in a single module and added to the commercially available Thermo Scientific Neptune XT MC-ICPMS to create a prototype MC-ICPMS/MS we named Vienna. Vienna was proven to retain the same performance of the base MC-ICPMS in terms of sensitivity, accuracy, and precision. Using the Vienna mass filter to eliminate Ar-based species, the abundance sensitivity achievable was equivalent to TIMS at mass 237.05, which was used to accurately determine the low 236U/238U isotope ratio of the uranium reference material IRMM184 (certified value, 1.2446 × 10-7). The performance of Vienna was then tested for a variety of geoscience applications that were expected to benefit from MC-ICPMS/MS technique, including Ca, K, Si, and in situ Rb/Sr dating by laser ablation.


Subject(s)
Isotopes , Mass Spectrometry , Spectrum Analysis
2.
J Anal At Spectrom ; 36(5): 917-931, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34092881

ABSTRACT

We document the utility for in situ Rb-Sr dating of a one-of-a-kind tribrid mass spectrometer, 'Proteus', coupled to a UV laser ablation system. Proteus combines quadrupole mass-filter, collision cell and sector magnet with a multicollection inductively-coupled plasma mass spectrometer (CC-MC-ICPMS/MS). Compared to commercial, single collector, tribrid inductively-coupled plasma mass spectrometers (CC-ICPMS/MS) Proteus has enhanced ion transmission and offers simultaneous collection of all Sr isotopes using an array of Faraday cups. These features yield improved precision in measured 87Sr/86Sr ratios, for a given mass of Sr analysed, approximately a factor of 25 in comparison to the Thermo Scientific™ iCAP TQ™ operated under similar conditions. Using SF6 as a reaction gas on Proteus, measurements of Rb-doped NIST SRM (standard reference material) 987 solutions, with Rb/Sr ratios from 0.01-100, yield 87Sr/86Sr that are indistinguishable from un-doped NIST SRM 987, demonstrating quantitative 'chemical resolution' of Rb from Sr. We highlight the importance of mass-filtering before the collision cell for laser ablation 87Sr/86Sr analysis, using an in-house feldspar standard and a range of glass reference materials. By transmitting only those ions with mass-to-charge ratios 82-92 u/e into the collision cell, we achieve accurate 87Sr/86Sr measurements without any corrections for atomic or polyatomic isobaric interferences. Without the pre-cell mass-filtering, measured in situ 87Sr/86Sr ratios are inaccurate. Combining in situ measurements of Rb/Sr and radiogenic Sr isotope ratios we obtain mineral isochrons. We utilise a sample from the well-dated Dartmoor granite (285 ± 1 Ma) as a calibrant for our in situ ages and, using the same conditions, produce accurate Rb-Sr isochron ages for samples of the Fish Canyon tuff (28 ± 2 Ma) and Shap granite pluton (397 ± 1 Ma). Analysing the same Dartmoor granite sample using identical laser conditions and number of spot analyses using the Thermo Scientific™ iCAP TQ™ yielded an isochron slope 5× less precise than Proteus. We use an uncertainty model to illustrate the advantage of using Proteus over single collector CC-ICPMS/MS for in situ Rb-Sr dating. The results of this model show that the improvement is most marked for samples that have low Rb/Sr (<10) or are young (<100 Ma). We also report the first example of an in situ, internal Rb-Sr isochron from a single potassium-feldspar grain. Using a sample from the Shap granite, we obtained accurate age and initial 87Sr/86Sr with 95% confidence intervals of ±1.5% and ±0.03% respectively. Such capabilities offer new opportunities in geochronological studies.

3.
Rapid Commun Mass Spectrom ; 34(23): e8918, 2020 Dec 15.
Article in English | MEDLINE | ID: mdl-32767797

ABSTRACT

RATIONALE: Magnesium is one of the most abundant elements in the earth's crust and in seawater. Fractionation of its stable isotopes has been shown to be a useful indicator of many geological, chemical, and biological processes. For example, biogenic carbonates display an ~5‰ range of δ26 Mg values, which is attributed to variable degrees of biological control on Mg ions during biomineralisation. Understanding this biological control is essential for developing proxies based on biogenic carbonates. METHODS: In this work, we present a new approach of measuring Mg isotopes in biogenic carbonates using Laser Ablation Multi-Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICPMS). RESULTS: Our results show that this microanalytical approach provides relatively fast, high spatial resolution (<0.2 µm) measurements with high precision and accuracy down to 0.2‰ (2SE). To achieve high levels of precision and accuracy, baseline interferences need to be monitored and a carbonate standard with a relatively low trace metal composition similar to biogenic carbonates should be used. We also demonstrate that the matrix effect on Mg isotopes in carbonates with low Fe and Mn is limited to less than 0.2‰ fractionation under different laser parameters and low oxide condition (<0.3% ThO/Th). CONCLUSIONS: Our newly developed LA-MC-ICPMS method and its applications to biogenic carbonates show significant advantages provided by the microanalytical approach in understanding complex processes of biomineralisation in marine calcifiers.


Subject(s)
Carbonates/analysis , Isotopes/analysis , Lasers , Magnesium/analysis , Mass Spectrometry/methods , Biomineralization , Carbonates/chemistry , Carbonates/metabolism
4.
Anal Chem ; 90(19): 11564-11571, 2018 10 02.
Article in English | MEDLINE | ID: mdl-30207702

ABSTRACT

The introduction of rapid response laser ablation cells and sample transport technologies to laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) has enabled signal pulse durations for a single laser ablation shot of less than 10 ms. These developments have resulted in marked improvements in analytical throughput, resolution, and sensitivity vital for the generation of large, highly spatially resolved elemental maps. The focus on mapping, particularly bioimaging, has obscured the possibility of applying the sensitivity advantage of rapid response technologies to other LA-ICPMS applications, such as high-precision isotope ratio analysis on multicollector (MC) ICPMS. In this work a commercially available rapid response sample transport system and a conventional configuration were compared for LA-MC-ICPMS analysis. Ablation of known reference materials demonstrated "sensitivity" or sample ion yield of 7-9% using the rapid response sample transport system, more than double that for the conventional setup. This increase in efficiency was demonstrated to improve precision for the Pb isotope ratio analysis of the MPI-DING reference glasses and improve the spatial resolution of Hf isotope ratio analysis of reference zircons.

5.
Rapid Commun Mass Spectrom ; 32(2): 93-104, 2018 Jan 30.
Article in English | MEDLINE | ID: mdl-29078008

ABSTRACT

RATIONALE: Li and Mg isotopes are increasingly used as a combined tool within the geosciences. However, established methods require separate sample purification protocols utilising several column separation procedures. This study presents a single-step cation-exchange method for quantitative separation of trace levels of Li and Mg from multiple sample matrices. METHODS: The column method utilises the macro-porous AGMP-50 resin and a high-aspect ratio column, allowing quantitative separation of Li and Mg from natural waters, sediments, rocks and carbonate matrices following the same elution protocol. High-precision isotope determination was conducted by multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) on the Thermo Scientific™ NEPTUNE Plus™ fitted with 1013  Ω amplifiers which allow accurate and precise measurements at ion beams ≤0.51 V. RESULTS: Sub-nanogram Li samples (0.3-0.5 ng) were regularly separated (yielding Mg masses of 1-70 µg) using the presented column method. The total sample consumption during isotopic analysis is <0.5 ng Li and <115 ng Mg with long-term external 2σ precisions of ±0.39‰ for δ7 Li and ±0.07‰ for δ26 Mg. The results for geological reference standards and seawater analysed by our method are in excellent agreement with published values despite the order of magnitude lower sample consumption. CONCLUSIONS: The possibility of eluting small sample masses and the low analytical sample consumption make this method ideal for samples of limited mass or low Li concentration, such as foraminifera, mineral separates or dilute river waters.

6.
Rapid Commun Mass Spectrom ; 32(1): 9-18, 2018 Jan 15.
Article in English | MEDLINE | ID: mdl-28990235

ABSTRACT

RATIONALE: Boron isotope ratios (δ11 B values) are used as a proxy for seawater paleo-pH, amongst several other applications. The analytical precision can be limited by the detection of low intensity ion beams from limited sample amounts. High-gain amplifiers offer improvements in signal/noise ratio and can be used to increase measurement precision and reduce sample amounts. METHODS: 1013 ohm amplifier technology has previously been applied to several radiogenic systems, but has thus far not been applied to non-traditional stable isotopes. Here we apply 1013 ohm amplifier technology for the measurement of boron isotope ratios using solution mode MC-ICP-MS and laser ablation mode (LA-)MC-ICP-MS techniques. Precision is shown for reference materials as well as for low-volume foraminifera samples. RESULTS: The baseline uncertainty for a 0.1 pA 10 B+ ion beam is reduced to <0.1 ‰ for a typical measurement period. The external precision is better than 0.2 ‰ (2SD) for δ11 B measurements for solution samples containing as little as 0.8 ng total boron. For in situ microanalyses with LA-MC-ICP-MS, the external precision of 11 B/10 B from an in-house calcite standard was 1 ‰ (2SD) for individual spot analyses, and 0.3 ‰ for the mean of ≥10 replicate spot analyses. CONCLUSIONS: 1013 ohm amplifier technology is demonstrated to offer advantages for the determination of δ11 B values by both MC-ICP-MS and LA-MC-ICP-MS for small samples of biogenic carbonates, such as foraminifera shells. 1013 ohm amplifier technology will also be of benefit to other non-traditional stable isotope measurements.

7.
Science ; 339(6120): 647, 2013 Feb 08.
Article in English | MEDLINE | ID: mdl-23393248

ABSTRACT

Fromm et al. and Vernier et al. suggest that their analyses of satellite measurements indicate that the main part of the Nabro volcanic plume from the eruption on 13 June 2011 was directly injected into the stratosphere. We address these analyses and, in addition, show that both wind trajectories and height-resolved profiles of sulfur dioxide indicate that although the eruption column may have extended higher than the Smithsonian report we highlighted, it was overwhelmingly tropospheric. Additionally, the height-resolved sulfur dioxide profiles provide further convincing evidence for convective transport of volcanic gas to the stratosphere from deep convection associated with the Asian monsoon.

8.
Science ; 337(6090): 78-81, 2012 Jul 06.
Article in English | MEDLINE | ID: mdl-22767926

ABSTRACT

The Nabro stratovolcano in Eritrea, northeastern Africa, erupted on 13 June 2011, injecting approximately 1.3 teragrams of sulfur dioxide (SO(2)) to altitudes of 9 to 14 kilometers in the upper troposphere, which resulted in a large aerosol enhancement in the stratosphere. The SO(2) was lofted into the lower stratosphere by deep convection and the circulation associated with the Asian summer monsoon while gradually converting to sulfate aerosol. This demonstrates that to affect climate, volcanic eruptions need not be strong enough to inject sulfur directly to the stratosphere.

9.
Sci Total Environ ; 390(1): 58-68, 2008 Feb 01.
Article in English | MEDLINE | ID: mdl-17976690

ABSTRACT

Inhaled depleted uranium (DU) aerosols are recognised as a distinct human health hazard and DU has been suggested to be responsible in part for illness in both military and civilian populations that may have been exposed. This study aimed to develop and use a testing procedure capable of detecting an individual's historic milligram-quantity aerosol exposure to DU up to 20 years after the event. This method was applied to individuals associated with or living proximal to a DU munitions plant in Colonie New York that were likely to have had a significant DU aerosol inhalation exposure, in order to improve DU-exposure screening reliability and gain insight into the residence time of DU in humans. We show using sensitive mass spectrometric techniques that when exposure to aerosol has been unambiguous and in sufficient quantity, urinary excretion of DU can be detected more than 20 years after primary DU inhalation contamination ceased, even when DU constitutes only approximately 1% of the total excreted uranium. It seems reasonable to conclude that a chronically DU-exposed population exists within the contamination 'footprint' of the munitions plant in Colonie, New York. The method allows even a modest DU exposure to be identified where other less sensitive methods would have failed entirely. This should allow better assessment of historical exposure incidence than currently exists.


Subject(s)
Radioactive Pollutants/urine , Uranium/urine , Geologic Sediments/analysis , Humans , Inhalation Exposure/analysis , New York/epidemiology , Radioactive Pollutants/analysis , Risk Assessment , Uranium/analysis , Water Supply/analysis
11.
Appl Opt ; 42(8): 1441-50, 2003 Mar 10.
Article in English | MEDLINE | ID: mdl-12645980

ABSTRACT

The possibility of retrieving horizontal atmospheric structure from a series of limb images taken aboard a satellite is discussed and a maximum likelihood expectation maximization algorithm is developed. Examples of the retrieval of horizontal structure with this algorithm, for different S/N (signal-to-noise) ratios and different structures, are presented. It is shown that with this algorithm and even in the presence of substantial observational noise, a S/N equal to 10 for a single observation, it is possible to retrieve both horizontal and vertical atmospheric structure.