Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
Add more filters










Publication year range
1.
J Biophotonics ; : e202400052, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38952197

ABSTRACT

A Mueller matrix polarimetry system at 532 nm wavelength is developed for noninvasive glucose sensing in turbid media such as human's fingertip. The system extracts mean absorbance and anisotropic properties, demonstrated numerically and experimentally with phantom glucose samples. It is found that mean absorbance ( A e $$ {A}_e $$ ), depolarization index (Δ), and linear dichroism (LD) show linear variation with glucose concentration 100-500 mg/dL. In addition, LightTools simulations indicate proportional scaling of scattering effects with A e $$ {A}_e $$ , Δ, and LD. Real-world tests on fingertip show a strong correlation between these properties and blood glucose levels with a mean absolute relative deviation (MARD) of 12.56% and a correlation coefficient (R2) of 0.875 in prediction by a neural network (NN) model, highlighting the advantages of Mueller matrix in extracting more parameters related to blood glucose.

2.
Biomed Opt Express ; 15(5): 3492-3506, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38855686

ABSTRACT

This study introduces a cutting-edge fiber-optic dosimetry (FOD) sensor designed for measuring radiation in biological settings. The accuracy and precision of dosimeters for small animals, particularly prolonged exposure to nonuniform radiation fields, are always challenging. A state-of-the-art in-vivo dosimeter utilizing glass-encapsulated Thermoluminescence cylindrical detector (TLD) was introduced. The FODs are implanted into the rat during a prolonged irradiation scenario involving 137Cs where the rat has the freedom to move within a heterogeneous radiation domain. The implantation surgery was verified with X-ray computed tomography (CT) in addition to biochemical and pathological tests to assess the biocompatibility of FOD in vivo. A versatile FOD is designed for industrial and medical fields, which demand accurate and resilient radiation dosimeters. The dose measurements are associated with precise two-dimensional (2D) radiation distribution imaging. Three cylindrical FODs and three standards TLD_100 for each rat were tested. The measurements of peak irradiation before and after exposure reveal greater stability and superior sensitivity when compared to standard thermo-luminescence detectors in an in-vivo animal test. To the best of our knowledge, FOD testing on live animals is presented for the first time in this paper. Regarding the safety and biocompatibility of FOD, no morphological signs with any kind of inflammation or sensitivity toward the FOD material have been remarked. Moreover, with the current FOD, there is no oedema between the epidermal, dermal, and subdermal sections at the site of implantation. The results also show the stable levels of white blood cells (lymphocytes, granulocytes, MID) as blood inflammatory markers before surgery and at the time of extraction of the implanted dosimeters, thus confirming the biocompatibility for each optical fiber cylinder dosimeter. As a result, the new dosimeters have excellent biocompatibility in living tissues and have 100% accurate reusability intensity of the delivered radiation doses compared to TLD_100 which demonstrated a 45% reduction in its intensity accuracy.

3.
3D Print Addit Manuf ; 10(4): 732-748, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37609594

ABSTRACT

Laser powder bed fusion (LPBF) provides a rapid and versatile approach for producing parts with complex geometries. However, many parts with intricate geometries have overhang structures, which are not easily fabricated by using LPBF and are often downgraded by staircase effects, warpage, cracks, and dross formation. Thus, the present study proposes a combined numerical and experimental approach for determining the optimal settings of the laser power and scanning speed that minimize the surface roughness and maximize the density of Inconel 718 LPBF overhang structures. In the proposed approach, the heat transfer simulations are employed to determine the melt pool depth, the melt pool length, and the solid cooling rate within the feasible input space of laser power and scanning speed combinations. Notably, the simulations take account of both the difference in the material properties of the solid and powder materials, respectively, and the variation of the laser absorptivity in the depth direction of the powder layer. The simulation results are then used to train artificial neural networks for predicting the melt pool depth for 3600 combinations of the laser power and scanning speed within the input space. The resulting processing maps are screened in accordance with three quality criteria (namely the melt pool depth, the melt pool length, and the solid cooling rate) to determine the optimal processing region, which improves the surface roughness. The feasibility of the proposed approach is demonstrated by fabricating 10 × 10 and 20 × 20 mm2 horizontal overhang structures using parameter settings chosen from the optimal processing map. It shows that the optimal processing conditions result in a low surface roughness and a maximum density of 99.78%.

4.
Sensors (Basel) ; 22(24)2022 Dec 08.
Article in English | MEDLINE | ID: mdl-36560001

ABSTRACT

Mechanical energy harvesters including piezoelectric nanogenerators, electromagnetic generators and triboelectric nanogenerators (TENG) used to convert the mechanical motion into electricity are more and more important in the recent decades. Specifically, the fiber-based TENG (FTENG) has gained considerable favors due to its flexibility, light weight, and high environmental tolerance for the wearable devices. The traditional FTENGs made of Teflon result in better performance but are not suitable for long-term wear in person. Here, we propose a novel FTENG using a flexible micro-needle-structured polydimethylsiloxane (MN-PDMS) together with the comfortable commercially available 2D-polyester fibers, and electroless nickel-plated cotton cloth of which two are widely used in human daily life. The MN-PDMS is formed by a laser engraved mold for improving its output performance of FTENG compared to the flat-PDMS. The open-circuit voltage (Voc) and the short-circuit current (Isc) of MN-FTENG increased to 73.6 V and 36 µA, respectively, which are 34% and 37% higher than the flat-FTENG. In terms of power, the performance of MN-FTENG reaches 1.296 mW which is 89% higher than that of flat-TENG and it can also light up 90 LEDs. For application, human motion at the joints can be detected and collected with various signals that are used for the human-machine interface (HMI) through the cooperation of components for the Internet of Things (IoT). It can light up the LED bulb through MN-FTENG to potentially develop IoT HMI systems for human motion control of robot in the future.


Subject(s)
Internet of Things , Plant Roots , Humans , Bone Plates , Electricity , Man-Machine Systems
5.
Materials (Basel) ; 14(23)2021 Nov 30.
Article in English | MEDLINE | ID: mdl-34885505

ABSTRACT

An integrated simulation framework consisting of the 3D finite element method and 3D cellular automaton method is presented for simulating the multi-track and multi-layer selective laser melting (SLM) process. The framework takes account of all the major multi-physics phenomena in the SLM process, including the initial grain structure, the growth kinetics, the laser scanning strategy, the laser-powder and laser-matter interactions, the melt flow, and the powder-to-liquid-to-solid transformations. The feasibility of the proposed framework is demonstrated by simulating the evolution of the epitaxy grain structure of Inconel 718 (IN718) during a 15-layer SLM process performed using a bi-directional 67° rotation scanning strategy and various SLM process parameters. The simulation results are found to be in good agreement with the experimental observations obtained in the present study and in the literature. In particular, a strong (001) texture is observed in the final component, which indicates that the grains with a preferred <001> orientation win the competitive epitaxy grain growth process. In addition, the size and shape of the IN718 grains are governed primarily by the cooling rate, where the cooling rate is determined in turn by the SLM parameters and the build height. Overall, the results show that the proposed framework provides an accurate approach for predicting the final microstructures of SLM components, and therefore, it can play an important role in optimizing the SLM processing parameters in such a way as to produce components with the desired mechanical properties.

6.
Materials (Basel) ; 14(18)2021 Sep 10.
Article in English | MEDLINE | ID: mdl-34576428

ABSTRACT

The mechanical properties of selective laser melting (SLM) components are fundamentally dependent on their microstructure. Accordingly, the present study proposes an integrated simulation framework consisting of a three-dimensional (3D) finite element model and a cellular automaton model for predicting the epitaxial grain growth mode in the single-track SLM processing of IN718. The laser beam scattering effect, melt surface evolution, powder volume shrinkage, bulk heterogeneous nucleation, epitaxial growth, and initial microstructure of the substrate are considered. The simulation results show that during single-track SLM processing, coarse epitaxial grains are formed at the melt-substrate interface, while fine grains grow at the melt-powder interface with a density determined by the intensity of the heat input. During the solidification stage, the epitaxial grains and bulk nucleated grains grow toward the top surface of the melt pool along the temperature gradient vectors. The rate of the epitaxial grain growth varies as a function of the orientation and size of the partially melted grains at the melt-substrate boundary, the melt pool size, and the temperature gradient. This is observed that by increasing heat input from 250 J/m to 500 J/m, the average grain size increases by ~20%. In addition, the average grain size reduces by 17% when the initial substrate grain size decreases by 50%. In general, the results show that the microstructure of the processed IN718 alloy can be controlled by adjusting the heat input, preheating conditions, and initial substrate grain size.

7.
Sensors (Basel) ; 19(12)2019 Jun 24.
Article in English | MEDLINE | ID: mdl-31238542

ABSTRACT

This work presents a novel and compact method for simultaneously measuring errors in linear displacement and vertical straightness of a moving linear air-bearing stage using 3D sinusoidal-groove linear reflective grating and a novel triangular wave-based sequence signal analysis method. The new scheme is distinct from the previous studies as it considers two signals to analyze linear displacement and vertical straightness. In addition, the tilt motion of the precision linear stage could also be measured using the 3D sinusoidal-groove linear reflective grating. The proposed system is similar to a linear encoder and can make online measurements of stage errors to analyze automatic processes and also be used for real-time monitoring. The performance of the proposed method and its reliability have been verified by experiments. The experiments show that the maximum error of measured tilt angle, linear displacement, and vertical straightness error is less than 0.058°, 0.239 µm, and 0.188 µm, respectively. The maximum repeatability error on measurement of tilt angle, linear displacement, and vertical straightness error is less than ±0.189o, ±0.093 µm, and ±0.016 µm, respectively. The proposed system is suitable for error compensation in the multi-axis system and finds application in most industries.

8.
Appl Opt ; 57(9): 2121-2127, 2018 Mar 20.
Article in English | MEDLINE | ID: mdl-29604002

ABSTRACT

A method is proposed for characterizing the optical properties of articular cartilage sliced from a pig's thighbone using a Stokes-Mueller polarimetry technique. The principal axis angle, phase retardance, optical rotation angle, circular diattenuation, diattenuation axis angle, linear diattenuation, and depolarization index properties of the cartilage sample are all decoupled in the proposed analytical model. Consequently, the accuracy and robustness of the extracted results are improved. The glucose concentration, collagen distribution, and scattering properties of samples from various depths of the articular cartilage are systematically explored via an inspection of the related parameters. The results show that the glucose concentration and scattering effect are both enhanced in the superficial region of the cartilage. By contrast, the collagen density increases with an increasing sample depth.

9.
J Biomed Opt ; 23(4): 1-9, 2018 04.
Article in English | MEDLINE | ID: mdl-29637760

ABSTRACT

A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index of aqueous glucose solutions with low and high scattering, respectively. It is shown that for both solutions, the optical rotation angle and depolarization index vary approximately linearly with the glucose concentration. As a result, the ability of the proposed method to obtain the glucose concentration by means of just two optical parameters is confirmed. The practical applicability of the proposed technique is demonstrated by measuring the optical rotation angle and depolarization index on the human fingertip of healthy volunteers under various glucose conditions.


Subject(s)
Blood Glucose/analysis , Fingers/diagnostic imaging , Signal Processing, Computer-Assisted , Tomography, Optical Coherence/methods , Algorithms , Equipment Design , Feasibility Studies , Humans , Phantoms, Imaging , Tomography, Optical Coherence/instrumentation
10.
Opt Express ; 25(13): 15179-15187, 2017 Jun 26.
Article in English | MEDLINE | ID: mdl-28788947

ABSTRACT

A differential Mueller matrix polarimetry technique is proposed for obtaining non-invasive (NI) measurements of the glucose concentration on the human fingertip. The feasibility of the proposed method is demonstrated by detecting the optical rotation angle and depolarization index of tissue phantom samples containing de-ionized water (DI), glucose solutions with concentrations ranging from 0~500 mg/dL and 2% lipofundin. The results show that the extracted optical rotation angle increases linearly with an increasing glucose concentration, while the depolarization index decreases. The practical applicability of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index properties of the human fingertips of healthy volunteers.


Subject(s)
Glucose/analysis , Optical Rotation , Spectrum Analysis/methods , Fingers , Humans
11.
J Biomed Opt ; 22(4): 47002, 2017 04 01.
Article in English | MEDLINE | ID: mdl-28384706

ABSTRACT

A surface plasmon resonance (SPR)-enhanced method is proposed for measuring the circular dichroism (CD), circular birefringence (CB), and degree of polarization (DOP) of turbid media using a Stokes­Mueller matrix polarimetry technique. The validity of the analytical model is confirmed by means of numerical simulations. The simulation results show that the proposed detection method enables the CD and CB properties to be measured with a resolution of 10 ? 4 refractive index unit (RIU) and 10 ? 5 ?? RIU , respectively, for refractive indices in the range of 1.3 to 1.4. The practical feasibility of the proposed method is demonstrated by detecting the CB/CD/DOP properties of glucose­chlorophyllin compound samples containing polystyrene microspheres. It is shown that the extracted CB value decreases linearly with the glucose concentration, while the extracted CD value increases linearly with the chlorophyllin concentration. However, the DOP is insensitive to both the glucose concentration and the chlorophyllin concentration. Consequently, the potential of the proposed SPR-enhanced Stokes­Mueller matrix polarimetry method for high-resolution CB/CD/DOP detection is confirmed. Notably, in contrast to conventional SPR techniques designed to detect relative refractive index changes, the SPR technique proposed in the present study allows absolute measurements of the optical properties (CB/CD/DOP) to be obtained.


Subject(s)
Circular Dichroism/methods , Nephelometry and Turbidimetry , Refractometry/methods , Scattering, Radiation , Algorithms , Anisotropy , Birefringence , Chlorophyllides/chemistry , Computer Simulation , Glucose/chemistry , Microspheres , Models, Theoretical , Polystyrenes , Spinacia oleracea/metabolism , Surface Plasmon Resonance
12.
J Biomed Opt ; 22(3): 35006, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28289750

ABSTRACT

The optical properties of biological tissues under stretching are investigated using a full-field ellipsometry technique based on a differential Mueller matrix formalism. Traditional photoelastic-based formalism for extracting the linear birefringence (LB) properties of stretched anisotropic optical samples ignores the effects of the other optical properties of the sample. By contrast, in the formalism proposed in this study, the LB, linear dichroism (LD), circular birefringence (CB), circular dichroism (CD), and depolarization (Dep) properties are fully decoupled. Simulations are performed to evaluate the performance of the two formalisms in extracting the LB properties of optically anisotropic samples with different degrees of Dep, CB, LD, and CD. The practical feasibility of the proposed all-parameter decoupled formalism is then demonstrated using chicken breast muscle tissue. In general, the results show that both formalisms provide a reliable LB measurement performance for healthy chicken breast tissue under stretching. However, while the LB-only formalism has good robustness toward scattering, its measurement performance is seriously degraded for samples with high CB. Thus, of the two formalisms, the proposed all-parameter decoupled formalism provides a more effective approach for examining the anisotropic properties of biological tissues under stretching.


Subject(s)
Optical Phenomena , Pectoralis Muscles/chemistry , Animals , Anisotropy , Birefringence , Chickens , Computer Simulation
13.
Appl Opt ; 55(19): 5001-7, 2016 Jul 01.
Article in English | MEDLINE | ID: mdl-27409183

ABSTRACT

A new laser galvanometric scanning optical system incorporating a dynamic-tilt focusing lens is proposed to improve the laser spot performance in adaptive manufacturing applications. The simulations focus specifically on the laser spot size, the spot profile, the spot position, the spot energy distribution, and the size of the scanning working field. It is shown that for a designed spot size of 50 µm, the proposed system achieves an average spot size of 50.5 µm. Moreover, the maximum position deviation of the laser beam is reduced from (x=-3.02%, y=1.30%) in a traditional scanning system to (x=-0.055%, y=0.162%) in the proposed system. Finally, the maximum working field area is increased by around 240% compared to that of a traditional system. Overall, the results show that the proposed laser galvanometric scanning system achieves a small spot size, a symmetrical and round spot profile, a uniform spot energy distribution, and a large working area. As a result, it is ideally suited to rapid prototyping applications.

14.
Opt Express ; 24(12): 12812-24, 2016 Jun 13.
Article in English | MEDLINE | ID: mdl-27410300

ABSTRACT

A novel method for enhanced circular dichroism (CD) detection is proposed based on a surface plasmon resonance (SPR) prism coupler and a polarization scanning ellipsometry technique. An analytical model is derived to extract the CD and degree of polarization (DOP) properties of optical samples with and without scattering effects, respectively. The validity of the analytical model is confirmed by means of numerical simulations. The simulation results show that the proposed detection method has a sensitivity of 10-5~10-6 RIU (refractive index unit) for refractive indices in the range of 1.32~1.36 and 1.3100~1.3118. The practical feasibility of the proposed method is demonstrated by the experimental results for the sensitivity of the CD with the chlorophyllin samples with/without scattering effect. It is shown that for both types of sample, the extracted CD value increases linearly with the chlorophyll concentration over the considered range. In general, the results obtained in this study show that the measured CD response is highly sensitive to the polarization scanning angle. Consequently, the potential of polarization scanning ellipsometry for high-resolution CD detection is confirmed.

15.
Carbohydr Polym ; 147: 409-414, 2016 08 20.
Article in English | MEDLINE | ID: mdl-27178947

ABSTRACT

This work develops a dual-function thermosensitive hydrogel to prevent overheating, a side effect of focused ultrasound therapy. The proposed hydrogel has the components of chitosan, ß-glycerophosphate, and glycerol. Its thermosensitive sol-to-gel transition gives an instant signal of overheating without the need of any awkward sensing device. Impacts of varying component concentrations on the sol-to-gel temperature, rate, and degree of transparency are also investigated. Chemical structures and ultrasonic coefficients after heating are obtained with a Fourier transform infrared spectroscopy and ultrasonic measurement, respectively. Optimized formula of the proposed hydrogel is 0.5% chitosan, 5% ß-glycerophosphate, and 25% glycerol. This hydrogel has a high acoustic impedance (Z=1.8 Mrayl) close to that of human skin, high ultrasonic transmission (T=99%, which is normalized to water) from 25 to 55°C, and low attenuation coefficient (α=4.0Np/m). These properties assure the success of dual functions of the hydrogel developed in this work.


Subject(s)
Chitosan/chemistry , Glycerol/chemistry , Glycerophosphates/chemistry , Hydrogels/chemistry , Ultrasonic Therapy/instrumentation , Hydrogel, Polyethylene Glycol Dimethacrylate , Temperature
16.
Opt Express ; 23(8): 10213-23, 2015 Apr 20.
Article in English | MEDLINE | ID: mdl-25969063

ABSTRACT

A dynamic polarization scanning ellipsometry technique based on Stokes polarimetry is proposed for dynamically characterizing a voltage-driven twisted nematic liquid crystal (TNLC) cell. In the proposed method, the six effective ellipsometric parameters are extracted under modulation voltages ranging from 0 V ~ + 10 V using four linearly polarized input lights. The profiles of the tilt angle and twist angle are calculated as a function of the modulation voltage. The validity of the proposed method is confirmed by comparing the experimental results for the effective ellipsometric parameters of a TNLC cell with the analytical results. Furthermore, a genetic algorithm (GA) based on a curve-fitting technique is used to inversely extract the pretilt angle, twist angle and rubbing direction of the TNLC cell. These extracted values are then compared to the known valued of the TNLC cell. In general, the results presented in this paper show that the proposed method provides a reliable means of obtaining the dynamic optical properties of a TNLC cell.

17.
Opt Express ; 23(8): 10653-67, 2015 Apr 20.
Article in English | MEDLINE | ID: mdl-25969104

ABSTRACT

A method is proposed for extracting the linear birefringence (LB) and linear dichroism (LD) properties of an anisotropic optical sample using reflection-mode optical coherence tomography (OCT) and a hybrid Mueller matrix formalism. To ensure the accuracy of the extracted parameter values, a method is proposed for calibrating and compensating the polarization distortion effect induced by the beam splitters in the OCT system using a composite quarter-waveplate / half-waveplate / quarter-waveplate structure. The validity of the proposed method is confirmed by extracting the LB and LD properties of a quarter-wave plate and a defective polarizer. To the best of the authors' knowledge, the method proposed in this study represents the first reported attempt to utilize an inverse Mueller matrix formalism and a reflection-mode OCT structure to extract the LB and LD parameters of optically anisotropic samples.

18.
Appl Opt ; 54(35): 10425-31, 2015 Dec 10.
Article in English | MEDLINE | ID: mdl-26836866

ABSTRACT

An optical-based method is proposed for measuring the glucose concentration of samples containing scattering particles. In the proposed approach, a Stokes-Mueller reflection-based polarimetry technique is used to solve the Mueller matrices of a turbid glucose sample with circular birefringence and depolarization properties given six incident lights with different polarization states. Using an error function defined as the difference between the simulated output Stokes vectors and the experimental ones, a genetic algorithm is used to inversely derive the optical rotation and depolarization parameters of the experimental sample corresponding to the glucose concentration and scattering depolarization effect, respectively. The validity of the proposed method is demonstrated using glucose samples containing 0.02 ml and 0.04 ml lipofundin, respectively.


Subject(s)
Glucose/analysis , Algorithms , Animals , Birefringence , Humans , Models, Theoretical , Optical Phenomena , Scattering, Radiation
19.
Appl Opt ; 52(31): 7629-37, 2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24216667

ABSTRACT

Most phase unwrapping algorithms shift the 2π phase jump pixels to obtain the unwrapped phases, while most filtering algorithms remove the noisy pixels to avoid the fault of unwrapped phases. Thus, finding the positions of phase jump pixels and noisy pixels is important. This study proposed a modified detection scheme developed from the originally published noise and phase jump detection scheme [Opt. Express 19, 3086 (2011)]. The original detection scheme finds the noise positions and phase jump positions, and then marks these pixels in two maps, namely, the noise map and the phase jump map. One 2π phase jump contains a 2π-high position and a 0-low position. However, the original detection scheme usually finds a 2π-high position and misses a corresponding 0-low position, or usually finds a 0-low position and misses a corresponding 2π-high position. Moreover, the original detection scheme produces detection errors, containing the repeated pixels of phase jump or the wrong pixels generated by noise. Fortunately, the proposed modified detection scheme can find both the 2π-high position and the corresponding 0-low position. Moreover, the detection errors are also reduced by the proposed modified detection scheme. The robustness of the modified detection scheme is demonstrated both numerically and experimentally.

20.
Opt Express ; 21(14): 16831-53, 2013 Jul 15.
Article in English | MEDLINE | ID: mdl-23938533

ABSTRACT

A hybrid model comprising the differential Mueller matrix formalism and the Mueller matrix decomposition method is proposed for extracting the linear birefringence (LB), linear dichroism (LD), circular birefringence (CB), circular dichroism (CD), and depolarization properties (Dep) of turbid optical samples. In contrast to the differential-based Mueller matrix method, the proposed hybrid model provides full-range measurements of all the anisotropic properties of the optical sample. Furthermore, compared to the decomposition-based Mueller matrix method, the proposed model is insensitive to the multiplication order of the constituent basis matrices. The validity of the proposed method is confirmed by extracting the anisotropic properties of a compound chitosan-glucose-microsphere sample with LB/CB/Dep properties and two ferrofluidic samples with CB/CD/Dep and LB/LD/Dep properties, respectively. It is shown that the proposed hybrid model not only yields full-range measurements of all the anisotropic parameters, but is also more accurate and more stable than the decomposition method. Moreover, compared to the decomposition method, the proposed model more accurately reflects the dependency of the phase retardation angle and linear dichroism angle on the direction of the external magnetic field for ferrofluidic samples. Overall, the results presented in this study confirm that the proposed model has significant potential for extracting the optical parameters of real-world samples characterized by either single or multiple anisotropic properties.


Subject(s)
Algorithms , Models, Theoretical , Nephelometry and Turbidimetry/methods , Refractometry/instrumentation , Anisotropy , Computer Simulation , Equipment Design , Equipment Failure Analysis , Light , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...