Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 21(8)2021 Apr 08.
Article in English | MEDLINE | ID: mdl-33918061

ABSTRACT

In the framework of the MICADO (Measurement and Instrumentation for Cleaning And Decommissioning Operations) European Union (EU) project, aimed at the full digitization of low- and intermediate-level radioactive waste management, a set of 32 solid state thermal neutron detectors named SiLiF has been built and characterized. MICADO encompasses a complete active and passive characterization of the radwaste drums with neutrons and gamma rays, followed by a longer-term monitoring phase. The SiLiF detectors are suitable for the monitoring of nuclear materials and can be used around radioactive waste drums possibly containing small quantities of actinides, as well as around spent fuel casks in interim storage or during transportation. Suitable polyethylene moderators can be exploited to better shape the detector response to the expected neutron spectrum, according to Monte Carlo simulations that were performed. These detectors were extensively tested with an AmBe neutron source, and the results show a quite uniform and reproducible behavior.

2.
Phys Med ; 29(4): 379-87, 2013 Jun.
Article in English | MEDLINE | ID: mdl-22763280

ABSTRACT

Cone-beam breast Computed Tomography (bCT) is an X-ray imaging technique for breast cancer diagnosis, in principle capable of delivering a much more homogeneous dose spatial pattern to the breast volume than conventional mammography, at dose levels comparable to two-view mammography. We present an investigation of the three-dimensional dose distribution for a cone-beam CT system dedicated to breast imaging. We employed Monte Carlo simulations for estimating the dose deposited within a breast phantom having a hemiellipsoidal shape placed on a cylinder of 3.5 cm thickness that simulates the chest wall. This phantom represents a pendulant breast in a bCT exam with the average diameter at chest wall, assumed to correspond to a 5-cm-thick compressed breast in mammography. The phantom is irradiated in a circular orbit with an X-ray cone beam selected from four different techniques: 50, 60, 70, and 80 kVp from a tube with tungsten anode, 1.8 mm Al inherent filtration and additional filtration of 0.2 mm Cu. Using the Monte Carlo code GEANT4 we simulated a system similar to the experimental apparatus available in our lab. Simulations were performed at a constant free-in-air air kerma at the isocenter (1 µGy); the corresponding total number of photon histories per scan was 288 million at 80 kVp. We found that the more energetic beams provide a more uniform dose distribution than at low energy: the 50 kVp beam presents a frequency distribution of absorbed dose values with a coefficient of variation almost double than that for the 80 kVp beam. This is confirmed by the analysis of the relative dose profiles along the radial (i.e. parallel to the "chest wall") and longitudinal (i.e. from "chest wall" to "nipple") directions. Maximum radial deviations are on the order of 25% for the 80 kVp beam, whereas for the 50 kVp beam variations around 43% were observed, with the lowest dose values being found along the central longitudinal axis of the phantom.


Subject(s)
Cone-Beam Computed Tomography/methods , Mammography/methods , Radiation Dosage , Monte Carlo Method , Phantoms, Imaging , Radiometry
3.
Radiat Prot Dosimetry ; 150(3): 316-24, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22223721

ABSTRACT

Interventional cardiology procedures are increasing because they offer many advantages to patients compared with other techniques: therefore the Italian National Institution for Insurance against Accidents at Work decided to start a survey for monitoring the state-of-the-art regarding the professionals involved in those procedures. The survey covered six cardiology and medical physics Italian departments. Each centre was asked to record 10 examinations for five types of procedures: coronary angiography (CA), electrophysiology studies (ES), pacemaker implantation (PI), percutaneous transluminal coronary angioplasty (PTCA) and radiofrequency catheter ablation (RA). For each examination all the centres were requested to fill in a questionnaire containing information regarding the operator performing the examination, the patient and the procedure. A total of 290 examinations were recorded: 103 CA, 14 ES, 68 PI, 79 PTCA and 26 RA. As occupational doses are strongly related to patient doses, both patients and operators radiation dose data are reported. Ratios of maximum to minimum mean patient doses across the hospitals surveyed were 2.0, 3.9, 7.0, 1.8 and 1.4 for CA, ES, PI, PTCA and RA, respectively. The calculated rounded mean dose-area product values across all participating hospitals were comparable with other values reported in the literature. In general, specific radiation protection tools were used by all operators performing different procedures in all hospitals. A major issue in this survey was the absence of information about correlation between staff and patient doses in a single procedure: future studies could be more aimed to prospective goals where occupational exposures per procedure are monitored specifically.


Subject(s)
Cardiology , Heart Diseases/diagnostic imaging , Occupational Exposure , Radiation Dosage , Radiation Monitoring , Radiography, Interventional/standards , Adolescent , Adult , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary , Coronary Angiography , Female , Fluoroscopy , Health Surveys , Humans , Italy , Male , Middle Aged , Radiation Protection , Young Adult
4.
J Biomed Opt ; 16(11): 116023, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22112128

ABSTRACT

It has been recently shown that optical imaging (OI) methods can be used to image the in vivo biodistribution of several radiopharmaceuticals labeled with beta or alpha emitters. In this work particular attention has been focused on investigating the weaker optical signal induced by an almost pure gamma emitter like Tc-99m. Visible light emission measurements of a water solution containing Tc-99m were performed using a small animal OI system. A sequence of images was acquired for 24 h in order to study the decay of the luminescence signal. The difference between the luminescence decay half life and well-known Tc-99m half life was equal to 1%. in vivo imaging was performed by injecting one control nude mice with Tc-99m-MDP. Optical images obtained with equipment designed for bioluminescence imaging showed that a visible light emission was distinguishable and correctly localized in the bladder region where a higher concentration of Tc-99m-MDP was expected. The bladder to background ratio was always greater than 1. We conclude that the experimental data presented in this paper show that it is possible to detect in vivo luminescence optical photons induced by Tc-99m. This is important especially considering the large number of Tc-99m-based radiopharmaceutical currently available.


Subject(s)
Optics and Photonics/methods , Radionuclide Imaging/methods , Radiopharmaceuticals/chemistry , Technetium Tc 99m Medronate/chemistry , Animals , Mice , Mice, Nude , Radiopharmaceuticals/pharmacokinetics , Technetium Tc 99m Medronate/pharmacokinetics , Urinary Bladder/diagnostic imaging , Urinary Bladder/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...