Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
Add more filters










Publication year range
1.
Anal Chim Acta ; 1297: 342325, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38438246

ABSTRACT

This review summarizes the stepwise strategy and key points for magnetic beads (MBs)-based aptamer selection which is suitable for isolating aptamers against small and large molecules via systematic evolution of ligands by exponential enrichment (SELEX). Particularities, if any, are discussed according to the target size. Examples targeting small molecules (<1000 Da) such as xenobiotics, toxins, pesticides, herbicides, illegal additives, hormones, and large targets such as proteins (biomarkers, pathogens) are discussed and presented in tabular formats. Of special interest are the latest advances in more efficient alternatives, which are based on novel instrumentation, materials or microelectronics, such as fluorescence MBs-SELEX or microfluidic chip system-assisted MBs-SELEX. Limitations and perspectives of MBs-SELEX are also reviewed. Taken together, this review aims to provide practical insights into MBs-SELEX technologies and their ability to screen multiple potential aptamers against targets from small to large molecules.


Subject(s)
Herbicides , Chromatography, Affinity , Ligands , Microfluidics , Oligonucleotides
2.
Anal Chem ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38331397

ABSTRACT

The shortage of specific glycan recognition reagents has proven a significant hurdle in the development of assays to detect altered glycoforms associated with cancer. Here, a carbohydrate-binding aptamer originally selected against the glycan moiety of prostate-specific antigen (PSA) is used as a lectin-mimicking reagent. As a first proof-of-principle, this aptamer has been applied to develop a sandwich-type electrochemical biosensor for the detection of the serum amyloid P (SAP) component, a glycosylated protein whose increased sialylation has been associated with pancreatic cancer. The assay combines a specific antibody for this potential tumor biomarker and the aptamer as capture and detection receptors, respectively. Two oriented antibody immobilization approaches, protein A-based and boronic ester-based attachment to self-assembled monolayers built onto gold surfaces, were comparatively evaluated, the latter being able to circumvent the unwanted interaction between the aptamer and the glycans on the electrode-attached antibody. The resulting biosensing platform allows the detection of the SAP glycoprotein at levels of nanograms per milliliter with a reproducibility value lower than 20%, both in aqueous buffer and in serum. This work represents a proof-of-concept of a promiscuous ligand of proteins with high levels of sialylated glycans typically produced by cancer cells.

4.
Anal Bioanal Chem ; 416(9): 2089-2095, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38093115

ABSTRACT

Wearable sensors would revolutionize healthcare and personalized medicine by providing individuals with continuous and real-time data about their bodies and environments. Their integration into everyday life has the potential to enhance well-being, improve healthcare outcomes, and offer new opportunities for research. Capacitive sensors technology has great potential to enrich wearable devices, extending their use to more accurate physiological indicators. On the basis of capacitive sensors developed so far to monitor physical parameters, and taking into account the advances in capacitive biosensors, this work discusses the benefits of this type of transduction to design wearables for the monitoring of biomolecules. Moreover, it provides insights into the challenges that must be overcome to take advantage of capacitive transduction in wearable sensors for health.


Subject(s)
Biosensing Techniques , Wearable Electronic Devices , Humans , Biosensing Techniques/methods , Spectrum Analysis
5.
Anal Bioanal Chem ; 415(29-30): 7035-7045, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37794245

ABSTRACT

A major societal challenge is the development of the necessary tools for early diagnosis of diseases such as cancer and sepsis. Consequently, there is a concerted push to develop low-cost and non-invasive methods of analysis with high sensitivity and selectivity. A notable trend is the development of highly sensitive methods that are not only amenable for point-of-care (POC) testing, but also for wearable devices allowing continuous monitoring of biomarkers. In this context, a non-invasive test for the detection of a promising biomarker, the protein Interleukin-6 (IL-6), could represent a significant advance in the clinical management of cancer, in monitoring the chemotherapy response, or for prompt diagnosis of sepsis. This work reports a capacitive electrochemical impedance spectroscopy sensing platform tailored towards POC detection and treatment monitoring in human serum. The specific recognition of IL-6 was achieved employing gold surfaces modified with an anti-IL6 nanobody (anti-IL-6 VHH) or a specific IL-6 aptamer. In the first system, the anti-IL-6 VHH was covalently attached to the gold surface using a binary self-assembled-monolayer (SAM) of 6-mercapto-1-hexanol (MCH) and 11-mercaptoundecanoic acid. In the second system, the aptamer was chemisorbed onto the surface in a mixed SAM layer with MCH. The analytical performance for each label-free sensor was evaluated in buffer and 10% human serum samples and then compared. The results of this work were generated using a low-cost, thin film eight-channel gold sensor array produced on a flexible substrate providing useful information on the future design of POC and wearable impedance biomarker detection platforms.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Neoplasms , Sepsis , Humans , Biosensing Techniques/methods , Interleukin-6 , Aptamers, Nucleotide/chemistry , Gold/chemistry , Biomarkers , Electrodes , Electrochemical Techniques/methods
6.
Anal Bioanal Chem ; 415(11): 2045-2057, 2023 May.
Article in English | MEDLINE | ID: mdl-36344668

ABSTRACT

The glycosylation status of proteins is increasingly used as biomarker to improve the reliability in the diagnosis and prognosis of diseases as relevant as cancer. This feeds the need for tools that allow its simple and reliable analysis and are compatible with applicability in the clinic. With this objective in mind, this work reports the first bioelectronic immunoplatforms described to date for the determination of glycosylated haptoglobin (Hp) and the simultaneous determination of total and glycosylated Hp. The bioelectronic immunoplatform is based on the implementation of non-competitive bioassays using two different antibodies or an antibody and a lectin on the surface of commercial magnetic microcarriers. The resulting bioconjugates are labeled with the horseradish peroxidase (HRP) enzyme, and after their magnetic capture on disposable electroplatforms, the amperometric transduction using the H2O2/hydroquinone (HQ) system allows the single or multiple detection. The developed immunoplatform achieves limits of detection (LODs) of 0.07 and 0.46 ng mL-1 for total and glycosylated Hp in buffer solution, respectively. The immunoplatform allows accurate determination using simple and relatively short protocols (approx. 75 min) of total and glycosylated Hp in the secretomes of in vitro-cultured colorectal cancer (CRC) cells with different metastatic potentials, which is not feasible, due to lack of sensitivity, by means of some commercial ELISA kits and Western blot methodology.


Subject(s)
Biosensing Techniques , Neoplasms , Humans , Haptoglobins , Hydrogen Peroxide , Reproducibility of Results , Enzyme-Linked Immunosorbent Assay , Antibodies , Biosensing Techniques/methods
8.
Anal Bioanal Chem ; 414(1): 147-165, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34091712

ABSTRACT

The role of the extracellular matrix (ECM) remodeling in tumorigenesis and metastasis is becoming increasingly clear. Cancer development requires that tumor cells recruit a tumor microenvironment permissive for further tumor growth. This is a dynamic process that takes place by a cross-talk between tumor cells and ECM. As a consequence, molecules derived from the ECM changes associated to cancer are released into the bloodstream, representing potential biomarkers of tumor development. This article highlights the importance of developing and improving bioanalytical methods for the detection of ECM remodeling-derived components, as a step forward to translate the basic knowledge about cancer progression into the clinical practice.


Subject(s)
Biomarkers, Tumor , Extracellular Matrix Proteins/chemistry , Neoplasms/diagnosis , Extracellular Matrix Proteins/metabolism , Humans , Protein Conformation
9.
Anal Chim Acta ; 1189: 339206, 2022 Jan 02.
Article in English | MEDLINE | ID: mdl-34815029

ABSTRACT

The extracellular matrix (ECM) plays an essential role in tumor progression and invasion through its continuous remodeling. The growth of most carcinomas is associated with an excessive collagen deposition that provides the proper environment for tumor development and chemoresistance. The α1 chain of a minor human collagen, type XI, is overexpressed in some tumor stroma, but not found in normal stroma. To test the clinical utility of this collagen as a cancer biomarker, specific receptors are needed. Available antibodies do not show enough selectivity or are directed toward the propeptide region that is cleaved when the protein is released to the ECM. Here we show the selection of an aptamer for the specific C-telopeptide region using a 16-mer peptide as the target for the SELEX. The aptamer selected with a Kd of ∼25 nM was able to capture the collagen XI from cell lysates. It was also used for target detection in a mixed antibody-aptamer sandwich assay showing it can be useful for diagnostic purposes in biological fluids.


Subject(s)
Aptamers, Nucleotide , Collagen Type XI/analysis , Neoplasms , Biomarkers, Tumor , Extracellular Matrix , Humans , Neoplasms/diagnosis
10.
Biosens Bioelectron ; 192: 113520, 2021 Nov 15.
Article in English | MEDLINE | ID: mdl-34311209

ABSTRACT

The prostate specific antigen (PSA) test is the gold standard for the screening of prostate cancer (PCa), despite its limited clinical specificity. Long noncoding RNAs are released from the tumor tissue to the urine and show great potential for improving specificity in PCa diagnosis. This work reports on a sandwich-type hybridization assay to detect both the urinary biomarker prostate cancer antigen 3 (PCA3) and an endogenous control, the PSA mRNA. Multiple fluorescein-tagged hybridization assistant probes are used to promote the selective capture of this long noncoding RNA, and sensitivity by incorporating multiple redox enzymes per target molecule, after addition of antifluorescein Fab fragment-peroxidase conjugate. This strategy alleviates the problems associated with the low natural abundance of this marker, its large size, and complex secondary structure. The individual genosensors exhibit good sensitivity (2.48 ± 0.01 µA nM-1 and 6.4 ± 0.3 µA nM-1 for PCA3 and PSA, respectively), with wide linear ranges (from 25 pM to 10 nM for PCA3 and 1 nM for PSA), and detection limits in the low picomolar range (4.4 pM and 1.5 pM for PCA3 and PSA, respectively). This analytical performance is retained in the dual configuration without significant cross-talk, despite using the same enzyme label. The usefulness of this dual platform was demonstrated by analyzing RNA extracts from the prostate cancer cell line LNCaP and from urine samples of prostate cancer patients.


Subject(s)
Biosensing Techniques , Prostatic Neoplasms , RNA, Long Noncoding , Antigens, Neoplasm/genetics , Biomarkers, Tumor/genetics , Early Detection of Cancer , Humans , Male , Prostate-Specific Antigen , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/genetics , RNA, Long Noncoding/genetics
11.
Biosens Bioelectron ; 175: 112872, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33288424

ABSTRACT

Prostate specific antigen (PSA) is the common biomarker for prostate cancer (PCa). However, its lack of specificity to differentiate PCa from benign prostate disorders stimulates the search for alternative cancer biomarkers to improve the clinical management of the patients. Different studies have described changes in the core-fucosylation level of PSA between PCa patients and healthy controls. To exploit these findings, we have adapted an impedimetric aptamer-based sensor to the dual recognition of PSA. Two different aptamers, PSAG-1 and anti-PSA, are immobilized onto two adjacent nanostructured gold electrodes. The direct binding from diluted serum samples of specific glycosylated-PSA to the first sensor and total PSA to the second one leads to changes in the charge transfer resistance, which correlate to the amount of glycosylated and total PSA in the sample. The sensors are able to measure PSA in serum with a dynamic range between 0.26 and 62.5 ng/mL (PSAG-1) and from 0.64 to 62.5 ng/mL (anti-PSA), with a reproducibility of 5.4 %. The final output of the proposed platform is the ratio between PSAG-1 reactive PSA and total PSA, defined as the glycan score. The glycan score was tested in serum samples from patients with different pathologies, showing excellent correlation between the measured score and the known diagnosis of the patients. Hence this dual aptamer-based impedimetric biosensor could be used as a minimally invasive method for the diagnosis of prostate cancer.


Subject(s)
Biosensing Techniques , Prostatic Neoplasms , Humans , Male , Polysaccharides , Prostate-Specific Antigen , Prostatic Neoplasms/diagnosis , Reproducibility of Results
12.
Sensors (Basel) ; 20(19)2020 Sep 26.
Article in English | MEDLINE | ID: mdl-32993106

ABSTRACT

A personal glucose meter (PGM)-based method for quantitative detection of a urinary nucleic acid biomarker in prostate cancer screening, the so-called PCA3, is reported herein. A sandwich-type genoassay is conducted on magnetic beads to collect the target from the sample by specific hybridization, making the assay appropriate for PCA3 detection in biological fluids. The success of the method hinges on the use of alkaline phosphatase (ALP) to link the amount of nucleic acid biomarker to the generation of glucose. In particular, specifically attached ALP molecules hydrolyze D-glucose-1-phosphate into D-glucose, thus enabling the amplification of the recorded signal on the personal glucose meter. The developed genoassay exhibits good sensitivity (3.3 ± 0.2 mg glucose dL-1 pM-1) for PCA3, with a dynamic range of 5 to 100 pM and a quantification limit of 5 pM. Likewise, it facilitates point-of-care testing of nucleic acid biomarkers by using off-the-shelf PGM instead of complex instrumentation involved in traditional laboratory-based tests.


Subject(s)
Biomarkers/urine , Biosensing Techniques , Early Detection of Cancer/instrumentation , Nucleic Acids/urine , Prostate-Specific Antigen/urine , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnosis
13.
Biosens Bioelectron ; 165: 112339, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-32729482

ABSTRACT

Enzyme-linked immunosorbent assays are currently the most popular methods to quantify gluten in foods. Unfortunately, the antibodies used as specific receptors in such methods are not compatible with the usual solvents for the extraction of gluten proteins. In consequence, commercial tests require a high dilution of the sample after the extraction, increasing the limit of quantification and decreasing convenience. In this work, we have rationally truncated an aptamer capable of recognizing gliadin in a deep eutectic solvent (DES). The truncated aptamer is a 19-nucleotides-long DNA that minimizes self-hybridization, allowing the development of an electrochemical sandwich-based sensor for the quantification of gluten in the DES ethaline. The sensor incorporates two identical biotin-labeled truncated aptamers, one of which is immobilized on a carbon screen-printed electrode and the other reports the binding of gliadin after incubation in streptavidin-peroxidase. This sensor can detect gliadin in DES, with a dynamic range between 1 and 100 µg/L and an intra-assay coefficient of variation of 11%. This analytical performance allows the quantification of 20 µg of gluten/kg of food when 1 g of food is extracted with 10 mL of ethaline. We demonstrate the ability of this method to achieve the measurement of gluten in food samples, after the extraction with pure ethaline. The assay is useful for the analysis of residual gluten levels in foods, thus facilitating the evaluation of any potential health risk associated with the consumption of such food by people with celiac disease or other gluten-related disorders.


Subject(s)
Biosensing Techniques , Celiac Disease , Enzyme-Linked Immunosorbent Assay , Gliadin , Glutens , Humans , Solvents
14.
Anal Chim Acta ; 1124: 1-19, 2020 Aug 08.
Article in English | MEDLINE | ID: mdl-32534661

ABSTRACT

The tunability of SELEX procedure is an essential feature to supply bioaffinity receptors (aptamers) almost on demand for analytical and therapeutic purposes. This longstanding ambition is, however, not straightforward. Non-invasive cancer diagnosis, so called liquid biopsy, requires collection of body fluids with minimal or no sample pretreatment. In those raw matrices, aptamers must recognize minute amounts of biomarkers that are not unique entities but large sets of variants evolving with the disease stage. The susceptibility of aptasensors to assay conditions has driven the selection of aptamers to natural environments to ensure their optimum performance in clinical samples. We present herein a compilation of the SELEX procedures in natural milieus. By revising the electrochemical aptasensors applied to clinical samples for cancer diagnosis and tracing back to the original SELEX we analyze whether aptamers raised using these SELEX strategies are being incorporated to the diagnostic devices and how aptasensors are finding their way to a market dominated by antibody-based assays.


Subject(s)
Aptamers, Nucleotide/chemistry , Biosensing Techniques , Body Fluids/chemistry , Electrochemical Techniques , Neoplasms/diagnostic imaging , SELEX Aptamer Technique , Humans
15.
Biosensors (Basel) ; 10(5)2020 Apr 30.
Article in English | MEDLINE | ID: mdl-32365872

ABSTRACT

Affinity characterization is essential to develop reliable aptamers for tumor biomarker detection. For alpha-fetoprotein (AFP), a biomarker of hepatocellular carcinoma (HCC), two DNA aptamers were described with very different affinity. In this work, we estimate the dissociation constant of both of them by means of a direct assay on magnetic beads modified with AFP and electrochemical detection on carbon screen-printed electrodes (SPCE). Unlike previous works, both aptamers showed similar dissociation constant (Kd) values, in the subµM range. In order to improve the performance of these aptamers, we proposed the isothermal amplification of the aptamers by both terminal deoxynucleotidyl transferase (TdT) and rolling circle amplification (RCA). Both DNA amplifications improved the sensitivity and also the apparent binding constants from 713 nM to 189 nM for the short aptamer and from 526 nM to 32 nM for the long aptamer. This improvement depends on the true affinity of the binding pair, which ultimately limits the analytical usefulness.


Subject(s)
Aptamers, Nucleotide/chemistry , Biosensing Techniques , DNA/chemistry , Electrochemical Techniques , Nucleic Acid Amplification Techniques , alpha-Fetoproteins/analysis , Electrodes , Humans
17.
Talanta ; 197: 406-412, 2019 May 15.
Article in English | MEDLINE | ID: mdl-30771954

ABSTRACT

Cancer diagnosis based on serum biomarkers requires receptors of extreme sensitivity and selectivity. Tunability of aptamer selection makes them ideal for that challenge. However, aptamer characterization is a time-consuming task, not always thoroughly addressed, leading to suboptimal aptamer performance. In this work, we report on the affinity characterization and potential usage of two aptamers against a candidate cancer biomarker, the neutrophil gelatinase-associated lipocalin (NGAL). Electrochemical sandwich assays on Au electrodes and SPR experiments showed a restricted capture ability of one of the aptamers (LCN2-4) and a small detectability of the other (LCN2-2). Interestingly, a truncated version of the signaling aptamer LCN2-2 selectively binds to NGAL covalently linked to magnetic beads due to high local protein concentration. The functional affinity of this aptamer is enhanced by three-orders of magnitude using rolling circle amplification (RCA), completed in only 15 min, followed by hybridization with short complementary fluorescein-tag probes, enzyme labeling and chronoamperometric measurement. Microscale thermophoresis experiments show a poor affinity for the protein in solution, which urges the importance of a full and in-depth characterization of aptamers to be used as diagnostic reagents.


Subject(s)
Aptamers, Nucleotide/chemistry , Lipocalin-2/chemistry , Nucleic Acid Amplification Techniques , Aptamers, Nucleotide/metabolism , Biosensing Techniques , Electrochemical Techniques , Humans , Lipocalin-2/metabolism
18.
Anal Bioanal Chem ; 411(19): 4265-4275, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30683966

ABSTRACT

Despite having been underappreciated in favor of their protein-coding counterparts for a long time, long noncoding RNAs (lncRNAs) have emerged as functional molecules, which defy the central dogma of molecular biology, with clear implications in cancer. Altered expression levels of some of these large transcripts in human body fluids have been related to different cancer conditions that turns them into potential noninvasive cancer biomarkers. In this review, a brief discussion about the importance and current challenges in the determination of lncRNAs associated to cancer is provided. Different electrochemical nucleic acid-based strategies for lncRNAs detection are critically described. Future perspectives and remaining challenges for the practical implementation of these methodologies in clinical medicine are also discussed.


Subject(s)
Early Detection of Cancer , Genomics , RNA, Long Noncoding/genetics , Humans
19.
Biosens Bioelectron ; 128: 83-90, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30640124

ABSTRACT

The development of chemical sensors capable of detecting the specific glycosylation patterns of proteins offers a powerful mean for the early detection of cancer. Unfortunately, this strategy is scarcely explored because receptors recognizing the glycans linked to proteins are challenging to discover. In this work, we describe a simple method for directing the selection of aptamers toward the glycan structure of the glycoproteins, with prostate-specific antigen (PSA) as a model target. Using this strategy, we identified one aptamer (PSA-1) that binds the glycan moiety of PSA with reasonable affinity (a dissociation constant of 177 ±â€¯65 nM). Interestingly, an electrochemical sensor with a sandwich format employing the identified aptamer as a signaling receptor, provides a tool of discriminating human PSA from the unglycosylated protein, with a limit of detection of 0.66 ng/mL. The sensor responds to different levels of PSA in serum, correlating well with chemiluminescence ELISA used in hospitals even with higher potential to discriminate clinically meaningful prostate cancer. Although validation on a larger cohort is needed, this is the first demonstration of an aptamer-based sensor to detect PSA by focusing in its glycan moiety.


Subject(s)
Aptamers, Nucleotide/chemistry , Biosensing Techniques , Polysaccharides/chemistry , Prostatic Neoplasms/blood , Aptamers, Nucleotide/genetics , Gold/chemistry , Humans , Limit of Detection , Male , Prostate-Specific Antigen , Prostatic Neoplasms/genetics
20.
Water Sci Technol ; 77(9-10): 2436-2444, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29893732

ABSTRACT

Electrochemical oxidation of an emerging pollutant, 2-(4-methylphenoxy)ethanol (MPET), from water has been studied by cyclic voltammetry (CV). Multiwall carbon nanotubes glassy carbon electrodes (MWCNT-GCE) were used as working electrode due to their extraordinary properties. The oxidation process is irreversible, since no reduction peaks were observed in the reverse scan. The electrocatalytic effect of MWCNT was confirmed as the oxidation peak intensity increases in comparison to bare-GCE. The effect of functional groups on MWCNT was also studied by MWCNT functionalized with NH2 (MWCNT-NH2) and COOH (MWCNT-COOH) groups. The oxidation peak current decreases in the following order: MWCNT > MWCNT-NH2 > MWCNT-COOH. Taking into account the normalized peak current, MWCNT-NH2 exhibits the best results due to its strong interaction with MPET. Under optimal conditions (pH = 5.0 and volume of MWCNT = 10 µL), degradation was studied for MWCNT-GCE and MWCNT-NH2-GCE. A complete MPET removal was observed using MWCNT-GCE after four CV cycles, for a volume/area (V/A) ratio equal to 19. In the case of MWCNT-NH2-GCE, the maximum MPET removal was close to 90% for V/A = 37, higher than that obtained for MWCNT-GCE at the same conditions (≈80%). In both cases, no organic by-products were detected.


Subject(s)
Benzene Derivatives/chemistry , Electrochemical Techniques/instrumentation , Ethanol/analogs & derivatives , Nanotubes, Carbon/chemistry , Carbon/chemistry , Electrochemical Techniques/methods , Electrodes , Ethanol/chemistry , Hydrogen-Ion Concentration , Oxidation-Reduction , Water/chemistry , Water Pollutants, Chemical/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...