1.
J Neurosci Methods ; 382: 109728, 2022 12 01.
Article in English | MEDLINE | ID: mdl-36244524

ABSTRACT

BACKGROUND: A device for moving the head during MR imaging, called a Weighted Head Accelerator Mechanism (WHAM), rotates the head of a supine subject within programmable rotation limits and acceleration profiles. The WHAM can be used with custom MRI sequences to visualize the deformation and recoil of in vivo brain parenchyma with high temporal resolution, allowing element-wise calculation of strain and shear forces in the brain. Unlike previous devices, the WHAM can be configured to provide a wide range of motion and acceleration profiles. NEW METHOD: The WHAM was calibrated using a high-speed camera on a laboratory bench and in 1.5 Tesla and 3.0 Tesla MRI scanners using gel phantoms and human subjects. The MR imaging studies employed a spatial spin-saturation tagging sub-sequence, followed by serial image acquisition. In these studies, 256 images were acquired with a temporal resolution of 2.56 ms. Deformation of the brain was quantified by following the spatial tags in the images. RESULTS: MR imaging showed that the WHAM drove quantifiable brain motions using g forces less than those typically observed in day-to-day activities, with peak accelerations of ∼250 rad/sec2. COMPARISON WITH EXISTING METHODS: The peak pre-contact accelerations and velocities achieved by the WHAM device in this study are both higher than devices used in previous studies, while also allowing for modification of these factors. CONCLUSIONS: MR imaging performed with the WHAM provides a direct method to visualize and quantify "brain slosh" in response to rotational acceleration. Consequently, this approach might find utility in evaluating strategies to protect the brain from mild traumatic brain injury (mTBI).


Subject(s)
Brain , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Brain/physiology , Head , Acceleration , Rheology
2.
AJR Am J Roentgenol ; 202(1): W95-W105, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24370170

ABSTRACT

OBJECTIVE: The objective of our study was to develop a small 1.5-T MRI system for neonatal imaging that can be installed in the neonatal ICU (NICU) and to evaluate its performance in 15 neonates. SUBJECTS AND METHODS: A 1.5-T MR system designed for orthopedic use was adapted for neonatal imaging. Modifications included raising and leveling the magnet, construction of a patient table, and integration of imaging electronics from a high-performance adult-sized scanner. The system was used to perform MR examinations of the brain, abdomen, and chest in 15 medically stable neonates using standard clinical protocols. The scanning time was limited to 60 minutes. The MR examinations were performed without administering sedation to the patients. ECG, heart rate, oxygen saturation, and temperature were monitored continuously throughout the examination. The images were evaluated by two pediatric radiologists for overall study quality, motion artifact, spatial resolution, signal-to-noise ratio, and contrast. RESULTS: All 15 neonates were successfully imaged without sedation. No adverse MRI-related events were noted. In total, 19 brain and seven abdominal examinations were performed. Six chest and two cardiac examinations were also obtained. Gross (versus physiologic) subject motion proved to be the most influential factor in determining overall study and image quality. High-quality diagnostic images were obtained at each anatomic location. CONCLUSION: The customized neonatal MRI system provides state-of-the-art MRI capabilities in the NICU.


Subject(s)
Infant, Newborn, Diseases/diagnosis , Intensive Care Units, Neonatal , Magnetic Resonance Imaging/methods , Female , Humans , Infant, Newborn , Magnetic Resonance Imaging/instrumentation , Male