Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Childs Nerv Syst ; 36(3): 551-558, 2020 03.
Article in English | MEDLINE | ID: mdl-31786632

ABSTRACT

INTRODUCTION: Cranioplasty in children is a controversial and challenging issue, since there is still no consensus on the ideal material. Main problems in paediatric age are represented by the child's growing skull, the lower bone thickness and the high incidence of cerebrospinal fluid (CSF) disorders or brain swelling. Autologous bone is still considered the "gold standard". When it is not available, a wide range of alloplastic materials have been proposed. Hydroxyapatite, a ceramic-based derivative, bears a chemical composition very similar to the human natural bone, making this material a valuable alternative to other cranioplasty solutions. METHODS: All patients implanted with a custom-made porous hydroxyapatite device at Santobono-Pausilipon Hospital in Naples were retrospectively reviewed. A follow-up CT scan of the skull was performed from 1 up to 48 months postoperatively to document the bone ingrowth as well as the osteointegration process. The bone density was measured as according to the Hounsfield scale at the bone-implant interface. RESULTS: Between 2014 and 2018, 11 patients (7 males, 4 females) underwent cranioplasty with hydroxyapatite ceramic implants (HAP). Patients' age ranged between 3 and 16 years old. Initial aetiology was trauma in most cases. Two subjects were implanted with HAP as primary cranioplasty, 9 as revision surgery following previous cranioplasty failure. Sites of the cranial defect were unilateral fronto-temporo-parietal (N = 8), unilateral frontal (N = 1) and bifrontal (N = 2). Two patients with large bilateral defects received two prostheses. In one of these, the two prostheses were explanted and replaced with two back-up implants (accounting for a total of 15 implants in 11 patients). Osteointegration was measurable for 12 out of 15 implanted devices. The mean percentage was about 51%. There were six asymptomatic prosthesis fractures (40%), all occurring within 6 months from implant. In one case, the bifrontal prostheses were explanted and replaced. This was the only patient who underwent revision surgery. CONCLUSION: Hydroxyapatite ceramic implants represent a valid alternative to other cranioplasty solutions. Where coaptation occurs correctly, with good osteointegration, implant mechanical resistance increases over time.


Subject(s)
Durapatite , Plastic Surgery Procedures , Adolescent , Ceramics , Child , Child, Preschool , Female , Humans , Male , Prostheses and Implants , Retrospective Studies , Skull/diagnostic imaging , Skull/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...