Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 30(2): 1397-1409, 2022 Jan 17.
Article in English | MEDLINE | ID: mdl-35209301

ABSTRACT

The use of the new CYTOP (Cyclized Transparent Optical Polymer) fibres for the inscription of optical structures and the detection of different parameters has started to gain importance in the past decade. This work presents the design, simulation and manufacture of a CYTOP-based surrounding refractive index sensor for aqueous solutions, given its high sensitivity in the range 1.315 - 1.333 (at 1550 nm wavelength). The structure is based on a bent and polished fibre (in order to increase its sensitivity), the polished area being the surface on which a diffraction grating is inscribed with a femtosecond laser. The interaction of the field propagated by the fibre with the grating causes diffraction of certain orders towards the outside, depending, among other things, on the refractive index of the fluid. In addition to a maximum sensitivity of -208.8 nm/RIU and a remarkable insensitivity to temperature, it offers a spectral fingerprint of each sensed fluid.

2.
J Biomed Opt ; 22(3): 37001, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28253378

ABSTRACT

Different low-cost approaches based on fiber specklegram sensors are employed to measure the physiological activity of patients lying in bed. This study is conducted over 20 volunteers to measure the movement and heart rate (HR) using two different sensor designs placed at two different bed locations. Three different processing methods are developed and tested in order to extract useful information from the measured data. The results suggest that a stretched fiber optic configuration under the head of the person lying in bed is the optimal configuration to detect HR and motion, nonetheless the other tested possibilities also exhibit remarkably good performances. On the other hand, the three proposed processing methods also achieve a good precision in the HR detection. The sensor implementation is simple, not requiring any special conditions, and it provides robust performance. This leads to the conclusion that fiber specklegram technology is a feasible method to be used in real situations for heartbeat and movement monitoring.


Subject(s)
Fiber Optic Technology , Heart Rate , Monitoring, Physiologic/instrumentation , Humans , Movement
SELECTION OF CITATIONS
SEARCH DETAIL
...