Results 1 - 20 de 161
Filter
1.
Phys Med ; 112: 102640, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37441823

ABSTRACT

Phase-contrast imaging techniques address the issue of poor soft-tissue contrast encountered in traditional X-ray imaging. This can be accomplished with the propagation-based phase-contrast technique by employing a coherent photon beam, which is available at synchrotron facilities, as well as long sample-to-detector distances. This study demonstrates the optimization of propagation-based phase-contrast computed tomography (CT) techniques for multiscale X-ray imaging of the breast at the Elettra synchrotron facility (Trieste, Italy). Two whole breast mastectomy samples were acquired with propagation-based breast-CT using a monochromatic synchrotron beam at a pixel size of 60 µm. Paraffin-embedded blocks sampled from the same tissues were scanned with propagation-based micro-CT imaging using a polychromatic synchrotron beam at a pixel size of 4 µm. Images of both methodologies and of the same sample were spatially registered. The resulting images showed the transition from whole breast imaging with propagation-based breast-CT methodology to virtual histology with propagation-based micro-CT imaging of the same sample. Additionally, conventional histological images were matched to virtual histology images. Phase-contrast images offer a high resolution with low noise, which allows for a highly precise match between virtual and conventional histology. Furthermore, those techniques allow a clear discernment of breast structures, lesions, and microcalcifications, being a promising clinically-compatible tool for breast imaging in a multiscale approach, to either assist in the detection of cancer in full volume breast samples or to complement structure identification in paraffin-embedded breast tissue samples.


Subject(s)
Breast Neoplasms , Humans , Female , X-Ray Microtomography , X-Rays , Breast Neoplasms/diagnostic imaging , Mastectomy , Breast/diagnostic imaging
2.
Phys Med Biol ; 67(9)2022 04 25.
Article in English | MEDLINE | ID: mdl-35395648

ABSTRACT

Objective.To introduce the optimization of a customized GPU-based simultaneous algebraic reconstruction technique (cSART) in the field of phase-contrast breast computed tomography (bCT). The presented algorithm features a 3D bilateral regularization filter that can be tuned to yield optimal performance for clinical image visualization and tissues segmentation.Approach.Acquisitions of a dedicated test object and a breast specimen were performed at Elettra, the Italian synchrotron radiation (SR) facility (Trieste, Italy) using a large area CdTe single-photon counting detector. Tomographic images were obtained at 5 mGy of mean glandular dose, with a 32 keV monochromatic x-ray beam in the free-space propagation mode. Three independent algorithms parameters were optimized by using contrast-to-noise ratio (CNR), spatial resolution, and noise texture metrics. The results obtained with the cSART algorithm were compared with conventional SART and filtered back projection (FBP) reconstructions. Image segmentation was performed both with gray scale-based and supervised machine-learning approaches.Main results.Compared to conventional FBP reconstructions, results indicate that the proposed algorithm can yield images with a higher CNR (by 35% or more), retaining a high spatial resolution while preserving their textural properties. Alternatively, at the cost of an increased image 'patchiness', the cSART can be tuned to achieve a high-quality tissue segmentation, suggesting the possibility of performing an accurate glandularity estimation potentially of use in the realization of realistic 3D breast models starting from low radiation dose images.Significance.The study indicates that dedicated iterative reconstruction techniques could provide significant advantages in phase-contrast bCT imaging. The proposed algorithm offers great flexibility in terms of image reconstruction optimization, either toward diagnostic evaluation or image segmentation.


Subject(s)
Cadmium Compounds , Quantum Dots , Algorithms , Tellurium , Tomography, X-Ray Computed/methods
3.
Leukemia ; 31(11): 2416-2425, 2017 11.
Article in English | MEDLINE | ID: mdl-28336937

ABSTRACT

ARCTIC was a multicenter, randomized-controlled, open, phase IIB non-inferiority trial in previously untreated chronic lymphocytic leukemia (CLL). Conventional frontline therapy in fit patients is fludarabine, cyclophosphamide and rituximab (FCR). The trial hypothesized that including mitoxantrone with low-dose rituximab (FCM-miniR) would be non-inferior to FCR. A total of 200 patients were recruited to assess the primary end point of complete remission (CR) rates according to IWCLL criteria. Secondary end points were progression-free survival (PFS), overall survival (OS), overall response rate, minimal residual disease (MRD) negativity, safety and cost-effectiveness. The trial closed following a pre-planned interim analysis. At final analysis, CR rates were 76 FCR vs 55% FCM-miniR (adjusted odds ratio: 0.37; 95% confidence interval: 0.19-0.73). MRD-negativity rates were 54 FCR vs 44% FCM-miniR. More participants experienced serious adverse reactions with FCM-miniR (49%) compared to FCR (41%). There are no significant differences between the treatment groups for PFS and OS. FCM-miniR is not expected to be cost-effective over a lifetime horizon. In summary, FCM-miniR is less well tolerated than FCR with an inferior response and MRD-negativity rate and increased toxicity, and will not be taken forward into a confirmatory trial. The trial demonstrated that oral FCR yields high response rates compared to historical series with intravenous chemotherapy.


Subject(s)
Antineoplastic Agents/therapeutic use , Leukemia, Lymphocytic, Chronic, B-Cell/drug therapy , Rituximab/therapeutic use , Adult , Aged , Aged, 80 and over , Antineoplastic Agents/adverse effects , Antineoplastic Agents/economics , Costs and Cost Analysis , Dose-Response Relationship, Drug , Female , Humans , Male , Middle Aged , Rituximab/adverse effects , Rituximab/economics , Survival Analysis
4.
J Investig Allergol Clin Immunol ; 27(3): 175-182, 2017.
Article in English | MEDLINE | ID: mdl-27959286

ABSTRACT

BACKGROUND AND OBJECTIVE: Skin prick testing (SPT) with commercial extracts is the first step in the diagnosis of shrimp allergy, although its clinical efficiency is unknown. Objective: To analyze the clinical usefulness of all commercial crustacean extracts available for SPT in Italy. METHODS: We performed a multicenter study of 157 shrimp-allergic patients who underwent SPT with 5 commercial crustacean extracts and with house dust mite (HDM) extract. Commercial extracts were analyzed using SDS-PAGE and compared with a freshly prepared in-house shrimp extract. IgE to Pen a 1/Pen m 1, Pen m 2, and Pen m 4 was determined, and immunoblot analysis was performed on a large number of sera. RESULTS: The skin reactions caused by commercial crustacean extracts were extremely heterogeneous, resulting in 32 clinical profiles, with marked differences in protein content and missing proteins at molecular weights corresponding to those of major shrimp allergens. Only strong Pen a 1/Pen m 1 reactors reacted to both HDM and all 5 commercial extracts in SPT. Most patients, including those who were tropomyosin-negative, reacted to HDM. Patients reacted to a large and variable array of proteins, and IgE reactivity was common at high molecular weights (>50 kDa). CONCLUSIONS: The in vivo diagnosis of shrimp allergy must continue to be based on SPT with fresh material. Shrimp-allergic patients frequently react to a number of ill-defined high-molecular-weight allergens, thus leaving currently available materials for component-resolved diagnosis largely insufficient. Mites and crustaceans probably share several allergens other than tropomyosin.


Subject(s)
Allergens/immunology , Arthropod Proteins/immunology , Immunoglobulin E/immunology , Shellfish Hypersensitivity/diagnosis , Adolescent , Adult , Aged , Animals , Child , Child, Preschool , Electrophoresis, Polyacrylamide Gel , Female , Humans , Immunoblotting , Italy , Male , Middle Aged , Pyroglyphidae/immunology , Shellfish Hypersensitivity/immunology , Skin Tests , Tropomyosin/immunology , Young Adult
5.
Int J Obes (Lond) ; 41(2): 289-298, 2017 02.
Article in English | MEDLINE | ID: mdl-27795551

ABSTRACT

BACKGROUND/OBJECTIVES: In the last decade, a strict link between epigenetics and metabolism has been demonstrated. Histone deacetylases (HDACs) have emerged as key epigenetic regulators involved in metabolic homeostasis in normal and pathologic conditions. Here we investigated the effect of the class I HDAC inhibitor MS-275 in a model of obesity induced by a high-fat diet (HFD). METHODS: C57BL6/J male mice were fed HFD for 17 weeks and then randomized in two groups, treated intraperitoneally with vehicle dimethylsulfoxide (DMSO) or with the class I selective HDAC inhibitor MS-275 every other day for 22 days. Glucose tolerance test and measurement of body temperature during cold exposure were performed. Adipose tissues and liver were phenotypically characterized through histological analysis. Gene and protein expression analysis of brown and white adipose tissues (WATs) were performed. RESULTS: MS-275 treated mice showed 10% reduction of body weight, lower adipocyte size and improved glucose tolerance. Inhibition of class I HDAC determined reduction of adipocyte size and of fat mass, paralleled by higher expression of adipose functionality markers and by increased rate of lipolysis and fatty acid ß-oxidation. MS-275 also promoted thermogenic capacity, related to 'browning' of visceral and subcutaneous WAT, showing increased expression of uncoupling protein 1. In brown adipose tissue, we observed limited effects on gene expression and only reduction of brown adipocyte size. CONCLUSIONS: This study provides evidence that class I HDAC inhibition stimulated functionality and oxidative potential of adipose tissue, improving glucose tolerance and ameliorating the metabolic profile in diet-induced obese mice.


Subject(s)
Adipocytes, Brown/drug effects , Adipose Tissue, Brown/drug effects , Adipose Tissue, White/drug effects , Diet, High-Fat/adverse effects , Histone Deacetylase Inhibitors/pharmacology , Obesity/drug therapy , Obesity/metabolism , Adipocytes, Brown/metabolism , Adipose Tissue, Brown/metabolism , Adipose Tissue, White/metabolism , Animals , Benzamides/pharmacology , Disease Models, Animal , Gene Expression Profiling , Glucose Tolerance Test , Histone Deacetylases/metabolism , Male , Mice , Mice, Inbred C57BL , Obesity/enzymology , Pyridines/pharmacology , Thermogenesis/drug effects , Thermogenesis/genetics
6.
J. investig. allergol. clin. immunol ; 27(3): 175-182, 2017. tab, ilus
Article in English | IBECS | ID: ibc-163167

ABSTRACT

Background: Skin prick testing (SPT) with commercial extracts is the first step in the diagnosis of shrimp allergy, although its clinical efficiency is unknown. Objective: To analyze the clinical usefulness of all commercial crustacean extracts available for SPT in Italy. Methods: We performed a multicenter study of 157 shrimp-allergic patients who underwent SPT with 5 commercial crustacean extracts and with house dust mite (HDM) extract. Commercial extracts were analyzed using SDS-PAGE and compared with a freshly prepared in-house shrimp extract. IgE to Pen a 1/Pen m 1, Pen m 2, and Pen m 4 was determined, and immunoblot analysis was performed on a large number of sera. Results: The skin reactions caused by commercial crustacean extracts were extremely heterogeneous, resulting in 32 clinical profiles, with marked differences in protein content and missing proteins at molecular weights corresponding to those of major shrimp allergens. Only strong Pen a 1/Pen m 1 reactors reacted to both HDM and all 5 commercial extracts in SPT. Most patients, including those who were tropomyosin-negative, reacted to HDM. Patients reacted to a large and variable array of proteins, and IgE reactivity was common at high molecular weights (>50 kDa). Conclusions: The in vivo diagnosis of shrimp allergy must continue to be based on SPT with fresh material. Shrimp-allergic patients frequently react to a number of ill-defined high-molecular-weight allergens, thus leaving currently available materials for componentresolved diagnosis largely insufficient. Mites and crustaceans probably share several allergens other than tropomyosin (AU)


Introducción: Las pruebas cutáneas con extractos comerciales representan el primer paso en el diagnóstico de alergia a gamba, si bien, su eficacia clínica no está bien definida. Objetivos: El objetivo de este estudio fue analizar la utilidad clínica de todos los extractos comerciales disponibles en Italia frente a crustáceos en pruebas cutáneas. Métodos: En un estudio multicéntrico, se incluyeron 157 pacientes alérgicos a gamba a los que se realizaron pruebas cutáneas con cinco extractos comerciales de crustáceos y con ácaros del polvo doméstico. Los extractos comerciales fueron analizados mediante SDS-PAGE y comparados con un extracto de gamba preparado en fresco. Se determinó IgE frente a Pen a 1/Pen m 1; Pen m 2, y Pen m 4; y el análisis mediante inmunoblotting se realizó en un amplio número de sueros. Resultados: Los extractos de gamba comercializados dieron lugar a reacciones cutáneas muy poco homogéneas en 32 perfiles clínicos diferentes; así mismo, mostraron grandes diferencias en contenido proteico y, en algunos casos, a falta de proteína a pesos moleculares correspondientes a alérgenos mayoritarios de gamba. Únicamente los reactores más fuertes a Pen a1 /Pen m 1 reaccionaron tanto a ácaros del polvo de casa como a los cinco extractos comerciales en pruebas cutáneas. La mayoría de los pacientes, incluyendo los negativos a tropomiosina, reaccionaron a los ácaros del polvo. Los pacientes reaccionaron a un amplio y variable array de proteínas y se detectó con frecuencia reactividad de IgE en pesos moleculares altos (>50 kDa). Conclusiones: El diagnóstico in vivo de alergia a gamba todavía debe estar basado en pruebas cutáneas prick con producto fresco. Los pacientes alérgicos a gamba a menudo reaccionan a un número de alérgenos de peso molecular alto poco definido, lo que hace que las moléculas disponibles hoy en día para el diagnóstico por componentes sean muy insuficiente. Ácaros y crustáceos probablemente comparten varios alérgenos además de la tropiomiosina (AU)


Subject(s)
Humans , Allergens/analysis , Allergens/isolation & purification , Food Hypersensitivity/diagnosis , Skin Tests/methods , Shellfish/adverse effects , Hypersensitivity, Immediate/diagnosis , Plant Extracts/analysis , Skin Tests , Immunoglobulin E/analysis , Molecular Weight , In Vitro Techniques
7.
Phys Med ; 32(5): 681-90, 2016 May.
Article in English | MEDLINE | ID: mdl-27160829

ABSTRACT

PURPOSE: Within the SYRMA-CT collaboration based at the ELETTRA synchrotron radiation (SR) facility the authors investigated the imaging performance of the phase-contrast computed tomography (CT) system dedicated to monochromatic in vivo 3D imaging of the female breast, for breast cancer diagnosis. METHODS: Test objects were imaged at 38keV using monochromatic SR and a high-resolution CdTe photon-counting detector. Signal and noise performance were evaluated using modulation transfer function (MTF) and noise power spectrum. The analysis was performed on the images obtained with the application of a phase retrieval algorithm as well as on those obtained without phase retrieval. The contrast to noise ratio (CNR) and the capability of detecting test microcalcification clusters and soft masses were investigated. RESULTS: For a voxel size of (60µm)(3), images without phase retrieval showed higher spatial resolution (6.7mm(-1) at 10% MTF) than corresponding images with phase retrieval (2.5mm(-1)). Phase retrieval produced a reduction of the noise level and an increase of the CNR by more than one order of magnitude, compared to raw phase-contrast images. Microcalcifications with a diameter down to 130µm could be detected in both types of images. CONCLUSIONS: The investigation on test objects indicates that breast CT with a monochromatic SR source is technically feasible in terms of spatial resolution, image noise and contrast, for in vivo 3D imaging with a dose comparable to that of two-view mammography. Images obtained with the phase retrieval algorithm showed the best performance in the trade-off between spatial resolution and image noise.


Subject(s)
Breast Neoplasms/diagnostic imaging , Cadmium Compounds/chemistry , Mammography/methods , Synchrotrons , Tellurium/chemistry , Tomography, X-Ray Computed , Algorithms , Breast/diagnostic imaging , Calcinosis/diagnostic imaging , Contrast Media/chemistry , Equipment Design , Female , Humans , Microscopy, Phase-Contrast , Photons , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio
8.
Phys Med Biol ; 61(4): 1634-49, 2016 Feb 21.
Article in English | MEDLINE | ID: mdl-26836274

ABSTRACT

The aim of the SYRMA-CT collaboration is to set-up the first clinical trial of phase-contrast breast CT with synchrotron radiation (SR). In order to combine high image quality and low delivered dose a number of innovative elements are merged: a CdTe single photon counting detector, state-of-the-art CT reconstruction and phase retrieval algorithms. To facilitate an accurate exam optimization, a Monte Carlo model was developed for dose calculation using GEANT4. In this study, high isotropic spatial resolution (120 µm)(3) CT scans of objects with dimensions and attenuation similar to a human breast were acquired, delivering mean glandular doses in the range of those delivered in clinical breast CT (5-25 mGy). Due to the spatial coherence of the SR beam and the long distance between sample and detector, the images contain, not only absorption, but also phase information from the samples. The application of a phase-retrieval procedure increases the contrast-to-noise ratio of the tomographic images, while the contrast remains almost constant. After applying the simultaneous algebraic reconstruction technique to low-dose phase-retrieved data sets (about 5 mGy) with a reduced number of projections, the spatial resolution was found to be equal to filtered back projection utilizing a four fold higher dose, while the contrast-to-noise ratio was reduced by 30%. These first results indicate the feasibility of clinical breast CT with SR.


Subject(s)
Breast Neoplasms/diagnostic imaging , Synchrotrons , Tomography, X-Ray Computed/instrumentation , Algorithms , Humans , Tomography, X-Ray Computed/methods
9.
J Trace Elem Med Biol ; 34: 50-5, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26854245

ABSTRACT

This work aimed to investigate metal bioaccumulation by mussels (Perna perna) and Lion's Scallop (Nodipecten nodosus) farmed in tropical bays, in order to estimate spatial and temporal variation in the exposure to these elements, as well as human health risk. The concentration of each measured element was considered for this evaluation, using maximum residue level (MRL) in foods established by the Brazilian (ANVISA), American (USFDA) and European Communities (EC) legislations. Values for estimated daily ingestion (EDI) were determined for metals intake through mussel and scallop consumption. These estimates were compared with the reference value of (PTDI) proposed by World Health Organization (WHO). Trace elements concentration was measured on ninety mussels P. perna (tissue) and ninety Lion's Scallop N. nodosus (muscle and gonad) reared in four different tropical areas of the Southeast Brazilian coast, between 2009 and 2010. Zinc (Zn), Iron (Fe), Copper (Cu), Manganese (Mn), Chrome (Cr), Nickel (Ni), Cadmium (Cd) and Lead (Pb) concentrations were measured by flame atomic absorption spectrometry after acid mineralization. Cd and Mn were more efficiently bioaccumulated by scallops than mussels and the opposite was found for Fe, Cu and Ni. Guanabara Bay and Sepetiba Bay were considered the most impacted between ecosystems studied. Higher Cd values in Arraial do Cabo in the other sites studied were associated with upwelling that occurs in the region. Consumption of both species cannot be considered safe, because the Cu and Cr concentrations, in accordance with the limits established by the Brazilian Agency (ANVISA). On the other hand, any EDI value exceeded the corresponding value of the PTDI, proposed by World Health Organization (WHO).


Subject(s)
Bivalvia/metabolism , Metals/metabolism , Water Pollutants, Chemical/metabolism , Animals , Brazil , Cadmium/analysis , Cadmium/metabolism , Chromium/analysis , Chromium/metabolism , Copper/analysis , Copper/metabolism , Environmental Monitoring , Metals/analysis , Water Pollutants, Chemical/analysis
10.
J Phys Condens Matter ; 28(6): 065503, 2016 Feb 17.
Article in English | MEDLINE | ID: mdl-26792795

ABSTRACT

By means of density-functional-theoretic calculations, we investigate the structural and electronic properties of a hexagonal InP sheet and of hydrogen-passivated zigzag InP nanoribbons (ZInPNRs) with Stone-Wales (SW)-type defects. Our results show that the influence of this kind of defect is not limited to the defected region but it leads to the formation of ripples that extend across the systems, in keeping with the results obtained recently for graphene and silicene sheets. The presence of SW defects in ZInPNRs causes an appreciable broadening of the band gap and transforms the indirect-bandgap perfect ZInPNR into a direct-bandgap semiconductor. An external transverse electric field, regardless of its direction, reduces the gap in both the perfect and defective ZInPNRs.

11.
Phys Med Biol ; 61(2): 569-87, 2016 Jan 21.
Article in English | MEDLINE | ID: mdl-26683710

ABSTRACT

The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation from a synchrotron radiation source in the energetic range from 8 to 50 keV with 1 keV intervals, to evaluate the MGD. The code was validated with literature data, in terms of mammographic normalized glandular dose coefficients (DgN) and with ad hoc experimental data, in terms of computed tomography dose index (CTDI). Simulated cylindrical phantoms of different sizes (diameter at phantom base 8, 10, 12, 14 or 16 cm, axial length 1.5 times the radius) and glandular fraction by weight (0%, 14.3%, 25%, 50%, 75% and 100%) were implemented into the code. The validation of the code shows an excellent agreement both with previously published work and in terms of DgN and CDTI measurements. The implemented simulations show a dependence of the glandular dose estimate on the vertical dimension of the irradiated zone when a partial organ irradiation was implemented. Specific normalized coefficients for calculating the MGD to the whole breast or to the single irradiated slice were reported.


Subject(s)
Breast Neoplasms/radiotherapy , Mammary Glands, Human/radiation effects , Photons , Radiotherapy Planning, Computer-Assisted/methods , Synchrotrons , Tomography, X-Ray Computed/methods , Female , Humans , Phantoms, Imaging , Radiation Dosage
12.
Radiat Prot Dosimetry ; 168(1): 40-5, 2016 Jan.
Article in English | MEDLINE | ID: mdl-25737582

ABSTRACT

The response of LiF:Mg,Cu,P thermoluminescence dosemeters (type GR-200A) to monoenergetic radiation of energy 28, 35, 38 and 40 keV was evaluated with respect to irradiation with a calibrated (60)Co gamma-ray source. High-precision measurements of the relative air kerma response performed at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) showed a significant deviation of the average response to low-energy X-rays from that to (60)Co, with an over-response from 6 % (at 28 keV) to 22 % (at 40 keV). These data are not consistent with literature data for these dosemeters, where model predictions gave deviation from unity of the relative air kerma response of about 10 %. The authors conclude for the need of additional determinations of the low-energy relative response of GR-200A dosemeters, covering a wider range of monoenergetic energies sampled at a fine energy step, as planned in future experiments by their group at the ELETTRA facility.


Subject(s)
Synchrotrons , Thermoluminescent Dosimetry/methods , Air , Calibration , Cobalt Radioisotopes/analysis , Copper/chemistry , Fluorides/chemistry , Gamma Rays , Lithium Compounds/chemistry , Magnesium/chemistry , Phosphorus/chemistry , Photons , Radiation Dosage , X-Rays
13.
Phys Med Biol ; 60(16): N311-23, 2015 Aug 21.
Article in English | MEDLINE | ID: mdl-26267405

ABSTRACT

Mean glandular dose (MGD) is the main dosimetric quantity in mammography. MGD evaluation is obtained by multiplying the entrance skin air kerma (ESAK) by normalized glandular dose (DgN) coefficients. While ESAK is an empirical quantity, DgN coefficients can only be estimated with Monte Carlo (MC) methods. Thus, a MC parameters benchmark is needed for effectively evaluating DgN coefficients. GEANT4 is a MC toolkit suitable for medical purposes that offers to the users several computational choices. In this work we investigate the GEANT4 performances testing the main PhysicsLists for medical applications. Four electromagnetic PhysicsLists were implemented: the linear attenuation coefficients were calculated for breast glandularity 0%, 50%, 100% in the energetic range 8-50 keV and DgN coefficients were evaluated. The results were compared with published data. Fit equations for the estimation of the G-factor parameter, introduced by the literature for converting the dose delivered in the heterogeneous medium to that in the glandular tissue, are proposed and the application of this parameter interaction-by-interaction or retrospectively is discussed. G4EmLivermorePhysicsList shows the best agreement for the linear attenuation coefficients both with theoretical values and published data. Moreover, excellent correlation factor (r2>0.99) is found for the DgN coefficients with the literature. The final goal of this study is to identify, for the first time, a benchmark of parameters that could be useful for future breast dosimetry studies with GEANT4.


Subject(s)
Mammography/methods , Radiation Dosage , Software , Radiometry/methods
14.
Phys Chem Chem Phys ; 16(23): 11218-27, 2014 Jun 21.
Article in English | MEDLINE | ID: mdl-24776820

ABSTRACT

In this work, we present a density-functional theory (DFT) investigation of the phase stability, electrochemical stability and phase transformation mechanisms of the layered and over-lithiated Mn oxides. This study includes the thermodynamic stability of Li and oxygen vacancies, to examine the electrochemical activation mechanisms of these cathode materials. The DFT calculations provide phase diagrams of the Li-Mn-O system in both physical and chemical potential spaces, including the crystals containing vacancies as independent phases. The results show the ranges of electrochemical activity for both layered LiMnO2 and over-lithiated Li2MnO3. By using a thermodynamic model analysis, we found that the required temperature for oxygen evolution and Li vacancy formation is too high to be compatible with any practical synthesis temperature. Using solid-state transition calculations, we have identified the key steps in the phase transition mechanism of the layered LiMnO2 into the spinel phase. The calculated effects of pH on the Li-Mn-O phase stability elucidated the mechanism of Mn(2+) formation from the spinel phase under acidic conditions.

15.
Opt Express ; 22(7): 7989-8000, 2014 Apr 07.
Article in English | MEDLINE | ID: mdl-24718174

ABSTRACT

X-ray phase contrast imaging (XPCi) methods are sensitive to phase in addition to attenuation effects and, therefore, can achieve improved image contrast for weakly attenuating materials, such as often encountered in biomedical applications. Several XPCi methods exist, most of which have already been implemented in computed tomographic (CT) modality, thus allowing volumetric imaging. The Edge Illumination (EI) XPCi method had, until now, not been implemented as a CT modality. This article provides indications that quantitative 3D maps of an object's phase and attenuation can be reconstructed from EI XPCi measurements. Moreover, a theory for the reconstruction of combined phase and attenuation maps is presented. Both reconstruction strategies find applications in tissue characterisation and the identification of faint, weakly attenuating details. Experimental results for wires of known materials and for a biological object validate the theory and confirm the superiority of the phase over conventional, attenuation-based image contrast.


Subject(s)
Algorithms , Imaging, Three-Dimensional/methods , Microscopy, Phase-Contrast/methods , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Humans , Light , X-Rays
16.
Eur Ann Allergy Clin Immunol ; 45(5): 160-6, 2013 Sep 01.
Article in English | MEDLINE | ID: mdl-24129043

ABSTRACT

BACKGROUND: The prevalence of IgE reactivity against genuine walnut and hazelnut allergens is poorly defined. OBJECTIVE: The IgE response to walnut and hazelnut was investigated in Italian patients with primary allergy to these nuts. METHODS: Sera from 36 patients allergic to hazelnut and/or walnut, not reactive to PR-10, profilin, and LTP, underwent immunoblot analysis with extracts of both nuts. RESULTS: Most patients had a history of systemic symptoms following the ingestion of the offending food(s). Twelve patients were sensitized to both walnut and hazelnut, and 13 were sensitized to other nuts and seeds (cashew, peanut, sesame, pine nut, almond, Brazil nut, and pistachio). On walnut immunoblot, the 7 sera which scored positive showed much variability in their IgE profile. Two reacted uniquely at 10 kDa, and the others at 35 , 40, 45, 50, 67, and > 67 kDa. The profiles obtained under reducing and non-reducing conditions showed several differences. The 7 sera positive on hazelnut immunoblot under reducing conditions recognized sera at 10 kDa and at <10 kDa (n=1), 20 kDa (n=4), at about 22, 24, 30, 40, 43, 58, 60, and 90 kDa, and higher m.w. in other cases. Under non-reducing conditions IgE reactivity at 20, 28, 35, 40, 45, 60, 90, and 100 kDa, was detected. Only two sera scored positive under both conditions and showed an IgE profile that partly changed from one assay to another. CONCLUSION: The current list of walnut and hazelnut allergens is far from being complete. Both reducing and non-reducing conditions are needed to detect IgE reactivity in individual patients.


Subject(s)
Corylus/immunology , Immunoglobulin E/blood , Juglans/immunology , Nut Hypersensitivity/immunology , Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Male , Middle Aged
17.
Opt Express ; 21(6): 7384-99, 2013 Mar 25.
Article in English | MEDLINE | ID: mdl-23546122

ABSTRACT

Phase retrieval is a technique for extracting quantitative phase information from X-ray propagation-based phase-contrast tomography (PPCT). In this paper, the performance of different single distance phase retrieval algorithms will be investigated. The algorithms are herein called phase-attenuation duality Born Algorithm (PAD-BA), phase-attenuation duality Rytov Algorithm (PAD-RA), phase-attenuation duality Modified Bronnikov Algorithm (PAD-MBA), phase-attenuation duality Paganin algorithm (PAD-PA) and phase-attenuation duality Wu Algorithm (PAD-WA), respectively. They are all based on phase-attenuation duality property and on weak absorption of the sample and they employ only a single distance PPCT data. In this paper, they are investigated via simulated noise-free PPCT data considering the fulfillment of PAD property and weakly absorbing conditions, and with experimental PPCT data of a mixture sample containing absorbing and weakly absorbing materials, and of a polymer sample considering different degrees of statistical and structural noise. The simulation shows all algorithms can quantitatively reconstruct the 3D refractive index of a quasi-homogeneous weakly absorbing object from noise-free PPCT data. When the weakly absorbing condition is violated, the PAD-RA and PAD-PA/WA obtain better result than PAD-BA and PAD-MBA that are shown in both simulation and mixture sample results. When considering the statistical noise, the contrast-to-noise ratio values decreases as the photon number is reduced. The structural noise study shows that the result is progressively corrupted by ring-like artifacts with the increase of structural noise (i.e. phantom thickness). The PAD-RA and PAD-PA/WA gain better density resolution than the PAD-BA and PAD-MBA in both statistical and structural noise study.


Subject(s)
Algorithms , Image Enhancement/methods , Models, Statistical , Tomography/methods , X-Ray Diffraction/methods , Computer Simulation , Signal-To-Noise Ratio
18.
J Phys Condens Matter ; 25(8): 085506, 2013 Feb 27.
Article in English | MEDLINE | ID: mdl-23364241

ABSTRACT

Unlike graphene, a hexagonal InP sheet (HInPS) cannot be obtained by mechanical exfoliation from the native bulk InP, which crystallizes in the zinc blende structure under ambient conditions. However, by ab initio density functional theory calculations we found that a slightly buckled HInPS is stable both in pristine form and when doped with Zn atoms; the same occurred for hydrogen-passivated zigzag InP nanoribbons (ZInPNRs), quasi-one-dimensional versions of the quasi-two-dimensional material. We investigated the electronic properties of both nanostructures, in the latter case also in the presence of an external transverse electric field, and the results are compared with those of hypothetical planar HInPS and ZInPNRs. The band gaps of planar ZInPNRs were found to be tunable by the choice of strength of this field, and to show an asymmetric behavior under weak electric fields, by which the gap can either be increased or decreased depending on their direction; however, this effect is absent from slightly buckled ZInPNRs. The binding energies of the acceptor impurity states of Zn-doped HInPS and ZInPNRs were found to be similar and much larger than that of Zn-doped bulk InP. These latter findings show that the reduction of the dimensionality of these materials limits the presence of free carriers.


Subject(s)
Electronics , Indium/chemistry , Nanostructures/chemistry , Nanotubes, Carbon , Phosphines/chemistry , Zinc/chemistry , Computer Simulation , Models, Chemical
19.
Radiol Med ; 118(1): 89-100, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22744351

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the feasibility of phase-contrast mammography with synchrotron radiation using a high-resolution computed radiology (CR) system devoted to mammography. MATERIALS AND METHODS: The study was performed at the Synchrotron Radiation for Medical Physics (SYRMEP) beamline of the Elettra synchrotron radiation (SR) facility in Trieste (Italy); X-ray beams were in the range 16-22 keV with a high degree of monochromaticity and spatial coherence. The CR system evaluated is the FCR Profect CS by Fujifilm Global. The first images were obtained from test objects and surgical breast specimens. Images obtained using SR and both screen-film and the CR system were compared with images of the same samples acquired with digital mammography equipment. In view of the good quality of the results obtained, the CR system was used in two mammographic examinations with SR. RESULTS: Images acquired using SR and both screen-film and CR were obtained with the same level of delivered dose. Image quality obtained with CR was similar or superior to that of screen-film images. Moreover, the digital images obtained with SR were always better than those acquired using the digital mammography system. CONCLUSIONS: Phase-contrast mammography with SR using the studied CR system is a feasible option.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/methods , Synchrotrons , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Feasibility Studies , Female , Humans , Mastectomy , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted
20.
Ultrasonics ; 52(8): 971-4, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22939262

ABSTRACT

The goal of this paper is to propose an experimental method allowing the identification of the complete elastic tensor of anisotropic biological materials such as wood using only one sample. To do so, two complementary methods are used. First, the wood eigen-directions are defined from a sample of spherical shape that is then cut into a cube in a way to perform resonant ultrasound spectroscopy (RUS). The method is successfully applied on a reference beech sample with known orthotropic directions. A comparison of the identified elastic constants with those from the literature and some inferred from ultrasonic transmission measurements is given.