Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Appl Physiol (1985) ; 109(5): 1432-40, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20813981

ABSTRACT

Expulsive maneuvers (EMs) caused by simultaneous contraction of diaphragm and abdominal muscles shift substantial quantities of blood from the splanchnic circulation to the extremities. This suggests that the diaphragm assisted by abdominal muscles might accomplish ventilation and circulation simultaneously by repeated EMs. We tested this hypothesis in normal subjects by measuring changes (Δ) in body volume (Vb) by whole body plethysmography simultaneously with changes in trunk volume (Vtr) by optoelectronic plethysmography, which measures the same parameters as whole body plethysmography plus the volume of blood shifts (Vbs) between trunk and extremities: Vbs = ΔVtr-ΔVb. We also measured abdominal pressure, pleural pressure, the arterial pressure wave, and cardiac output (Qc). EMs with abdominal pressure ~100 cmH(2)O for 1 s, followed by 2-s relaxations, repeated over 90 s, produced a "stroke volume" from the splanchnic bed of 0.35 ± 0.07 (SD) liter, an output of 6.84 ± 0.75 l/min compared with a resting Qc of 5.59 ± 1.14 l/min. Refilling during relaxation was complete, and the splanchnic bed did not progressively empty. Diastolic pressure increased by 25 mmHg during each EM. Between EMs, Qc increased to 7.09 ± 1.14 l/min due to increased stroke volume and heart rate. The circulatory function of the diaphragm assisted by simultaneous contractions of abdominal muscles with appropriate pressure and duration at 20 min(-1) can produce a circulatory output as great as resting Qc, as well as ventilation. These combined functions of the diaphragm have potential for cardiopulmonary resuscitation. The abdominal circulatory pump can act as an auxiliary heart.


Subject(s)
Abdominal Muscles/physiology , Diaphragm/physiology , Hemodynamics , Muscle Contraction , Pulmonary Ventilation , Splanchnic Circulation , Adult , Aged , Blood Pressure , Cardiac Output , Female , Femoral Vein/physiology , Hepatic Veins/physiology , Humans , Male , Plethysmography, Whole Body , Pressure , Regional Blood Flow , Time Factors , Vena Cava, Inferior/physiology
2.
J Clin Sleep Med ; 5(6): 532-7, 2009 Dec 15.
Article in English | MEDLINE | ID: mdl-20465019

ABSTRACT

STUDY OBJECTIVES: Evaluate the efficacy of a novel device placed in the nares that imposes an expiratory resistance for the treatment of obstructive sleep apnea (OSA) and evaluate adherence to the device over a 30-day in-home trial period. DESIGN: One diagnostic and 3 treatment polysomnograms were administered in a Latin-square design to identify the optimal expiratory resistance to be used during the 30-day in-home trial. Subjects had repeat polysomnography with the prescribed device at the end of the 30-day trial. SETTING: Multicenter study. PARTICIPANTS: Participants (N=34; age 27 to 67) with a baseline apnea-hypopnea index (AHI) > or =5. MEASUREMENTS AND RESULTS: The AHI was reduced from 24.5 _ 23.6 (mean +/- SD) to an average of 13.5 +/- 18.7 (p < 0.001) across initial treatment nights. The AHI was 15.5 +/-+/- 18.9 (p = 0.001) for the prescribed device at the end of the 30-day trial. Of 24 subjects with an AHI > 10 at baseline, 13 achieved an AHI < 10 on the initial treatment nights; 10 had a similar response on the final treatment night. Percent of the night snoring decreased from 27.5 +/- 23.2 to 11.6 +/- 13.7 (p < 0.001) on initial treatment nights and 14.6 +/- 20.6 (p = 0.013) at the end of the trial; Epworth Sleepiness scores decreased from 8.7 +/- 4.0 at baseline to 6.9 +/- 4.4 (p < 0.001) at the end of the trial; the Pittsburgh Sleep Quality Index improved from 7.4 +/- 3.3 to 6.5 +/- 3.6 (p = 0.042). Mean oxygen saturation increased from 94.8 +/- 2.0 to 95.2 +/- 1.9 (p = 0.023) on initial treatment nights and 95.3 +/- 1.9 (p = 0.003) at the end of the trial. Sleep architecture was not affected. Participants reported using the device all night long for 94% of nights during the in-home trial. CONCLUSIONS: Treatment with this novel device was well tolerated and accepted by the participants. An overall reduction in AHI was documented; however, therapeutic response was variable among the participants. Further research is required to identify the ideal candidates for this new therapeutic option in the management of OSA.


Subject(s)
Exhalation , Patient Compliance/statistics & numerical data , Positive-Pressure Respiration/instrumentation , Sleep Apnea, Obstructive/therapy , Adult , Aged , Airway Resistance , Equipment Design , Female , Humans , Male , Middle Aged , Nasal Cavity , Polysomnography/methods , Polysomnography/statistics & numerical data , Positive-Pressure Respiration/methods , Prospective Studies , Treatment Outcome
3.
Chest ; 127(6): 1999-2006, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15947312

ABSTRACT

BACKGROUND: Bronchial thermoplasty is a novel procedure being developed as a potential treatment for asthma. Experience with animal studies has enabled development of appropriate reliable equipment, definition of therapeutic parameters, and descriptions of tissue effects of treatment. STUDY OBJECTIVES: This study was undertaken to assess the feasibility and general safety of the application of bronchial thermoplasty in the human airway, and to determine if the reduction in airway smooth muscle seen in animal studies could be replicated. DESIGN: A prospective study. SETTING: Academic thoracic surgery center. PARTICIPANTS: Nine patients scheduled to undergo lung resection for suspected or proven lung cancer. INTERVENTIONS: Bronchial thermoplasty was performed during routine preoperative bronchoscopy up to 3 weeks prior to prescheduled lung resection. Treatment was limited to areas of the segmental bronchi within the lobe that was to be removed. Treated airways were inspected via bronchoscopy at the time of thoracotomy, and were examined histologically following surgical resection. RESULTS: There were no adverse clinical effects of the procedure, including no new symptoms and no unscheduled visits for medical care. Treated sites exhibited slight redness and edema of the mucosa within 2 weeks of treatment, and appeared normal at later time points. There was narrowing (visually estimated at 25 to 50%) in four airways in two subjects examined at 5 days and 13 days after treatment, with excess mucus in two of these airways. There was no bronchoscopic evidence of scarring in any of the airways examined. Histologic examination showed a reduction in airway smooth muscle, and the extent of the treatment effect was confined to the airway wall and the immediate peribronchial region. CONCLUSION: Application of bronchial thermoplasty to the human airway appears to be well tolerated. Treatment resulted in significant reduction of smooth muscle mass in the airways. Bronchial thermoplasty may provide therapeutic benefit in disease states such as asthma.


Subject(s)
Catheter Ablation/methods , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Muscle, Smooth/surgery , Pneumonectomy/methods , Aged , Biopsy, Needle , Bronchoscopy/methods , Combined Modality Therapy , Feasibility Studies , Female , Follow-Up Studies , Humans , Immunohistochemistry , Male , Middle Aged , Postoperative Complications/epidemiology , Preoperative Care/methods , Prospective Studies , Risk Assessment , Survival Rate , Treatment Outcome
4.
J Appl Physiol (1985) ; 97(5): 1946-53, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15258133

ABSTRACT

We delivered controlled radio frequency energy to the airways of anesthetized, ventilated dogs to examine the effect of this treatment on reducing airway narrowing caused by a known airway constrictor. The airways of 11 dogs were treated with a specially designed bronchial catheter in three of four lung regions. Treatments in each of the three treated lung regions were controlled to a different temperature (55, 65, and 75 degrees C); the untreated lung region served as a control. We measured airway responsiveness to local methacholine chloride (MCh) challenge before and after treatment and examined posttreatment histology to 3 yr. Treatments controlled to 65 degrees C as well as 75 degrees C persistently and significantly reduced airway responsiveness to local MCh challenge (P < or = 0.022). Airway responsiveness (mean percent decrease in airway diameter after MCh challenge) averaged from 6 mo to 3 yr posttreatment was 79 +/- 2.2% in control airways vs. 39 +/- 2.6% (P < or = 0.001) for airways treated at 65 degrees C, and 26 +/- 2.7% (P < or = 0.001) for airways treated at 75 degrees C. Treatment effects were confined to the airway wall and the immediate peribronchial region on histological examination. Airway responsiveness to local MCh challenge was inversely correlated to the extent of altered airway smooth muscle observed in histology (r = -0.54, P < 0.001). We conclude that the temperature-controlled application of radio frequency energy to the airways can reduce airway responsiveness to MCh for at least 3 yr in dogs by reducing airway smooth muscle contractility.


Subject(s)
Bronchial Hyperreactivity/chemically induced , Bronchial Hyperreactivity/physiopathology , Bronchoconstrictor Agents , Methacholine Chloride , Radio Waves , Animals , Bronchi/pathology , Bronchi/physiopathology , Bronchi/radiation effects , Bronchial Hyperreactivity/pathology , Bronchial Hyperreactivity/prevention & control , Dogs , Muscle, Smooth/pathology , Muscle, Smooth/physiopathology , Muscle, Smooth/radiation effects , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...