Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(17)2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36081060

ABSTRACT

Deep brain stimulation of the Anterior Nucleus of the Thalamus (ANT-DBS) is an effective therapy in epilepsy. Poorer surgical outcomes are related to deviations of the lead from the ANT-target. The target identification relies on the visualization of anatomical structures by medical imaging, which presents some disadvantages. This study aims to research whether ANT-LFPs recorded with the PerceptTM PC neurostimulator can be an asset in the identification of the DBS-target. For this purpose, 17 features were extracted from LFPs recorded from a single patient, who stayed at an Epilepsy Monitoring Unit for a 5-day period. Features were then integrated into two machine learning (ML)-based methodologies, according to different LFP bipolar montages: Pass1 (nonadjacent channels) and Pass2 (adjacent channels). We obtained an accuracy of 76.6% for the Pass1-classifier and 83.33% for the Pass2-classifier in distinguishing locations completely inserted in the target and completely outside. Then, both classifiers were used to predict the target percentage of all combinations, and we found that contacts 3 (left hemisphere) and 2 and 3 (right hemisphere) presented higher signatures of the ANT-target, which agreed with the medical images. This result opens a new window of opportunity for the use of LFPs in the guidance of DBS target identification.


Subject(s)
Anterior Thalamic Nuclei , Deep Brain Stimulation , Epilepsy , Anterior Thalamic Nuclei/physiology , Deep Brain Stimulation/methods , Electrodes , Epilepsy/therapy , Humans
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4559-4562, 2020 07.
Article in English | MEDLINE | ID: mdl-33019008

ABSTRACT

Wearable devices have been showing promising results in a large range of applications: since industry, to entertainment and, in particular, healthcare. In the scope of movement disorders, wearable devices are being widely implemented for motor symptoms objective assessment. Currently, clinicians evaluate patients' motor symptoms resorting to subjective scales and visual perception, such as in Parkinson's Disease. The possibility to make use of wearable devices to quantify this disorder motor symptoms would bring an accurate follow-up on the disease progression, leading to more efficient treatments.Here we present a novel textile embedded low-power wearable device capable to be used in any scenario of movement disorders assessment due to its seamless, comfort and versatility. Regarding our research, it has already improved the setup of a wrist rigidity quantification system for Parkinson's Disease patients: the iHandU system. The wearable comprises a hardware sensing unit integrated in a textile band with an innovative design assuring higher comfort and easiness-to-use in movement disorders assessment. It enables to collect inertial data (9-axis) and has the possibility to integrate two analog sensors. A web platform was developed for data reading, visualization and recording. To ensure inertial data reliability, validation tests for the accelerometer and gyroscope sensors were conducted by comparison with its theoretical behavior, obtaining very good results.


Subject(s)
Parkinson Disease , Wearable Electronic Devices , Humans , Parkinson Disease/therapy , Reproducibility of Results , Textiles , Wrist Joint
3.
Sensors (Basel) ; 20(2)2020 Jan 07.
Article in English | MEDLINE | ID: mdl-31936023

ABSTRACT

Deep brain stimulation (DBS) surgery is the gold standard therapeutic intervention in Parkinson's disease (PD) with motor complications, notwithstanding drug therapy. In the intraoperative evaluation of DBS's efficacy, neurologists impose a passive wrist flexion movement and qualitatively describe the perceived decrease in rigidity under different stimulation parameters and electrode positions. To tackle this subjectivity, we designed a wearable device to quantitatively evaluate the wrist rigidity changes during the neurosurgery procedure, supporting physicians in decision-making when setting the stimulation parameters and reducing surgery time. This system comprises a gyroscope sensor embedded in a textile band for patient's hand, communicating to a smartphone via Bluetooth and has been evaluated on three datasets, showing an average accuracy of 80%. In this work, we present a system that has seen four iterations since 2015, improving on accuracy, usability and reliability. We aim to review the work done so far, outlining the iHandU system evolution, as well as the main challenges, lessons learned, and future steps to improve it. We also introduce the last version (iHandU 4.0), currently used in DBS surgeries at São João Hospital in Portugal.


Subject(s)
Deep Brain Stimulation , Neurosurgical Procedures , Software , Wrist/physiology , Humans , Motion , Signal Processing, Computer-Assisted , Wearable Electronic Devices
4.
Clin Neurol Neurosurg ; 186: 105537, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31605896

ABSTRACT

OBJECTIVE: Axial motor features are common in Parkinson's disease (PD). These include gait impairment and postural abnormalities, such as camptocormia. The response of these symptoms to deep brain stimulation (DBS) is variable and difficult to assess objectively. For the first time, this study analyzes the treatment outcomes of two PD patients with camptocormia that underwent bilateral subthalamic nucleus (STN)-DBS evaluated with disruptive technologies. PATIENTS AND METHODS: Two patients with PD and camptocormia who underwent STN-DBS were included. Gait parameters were quantitatively assessed before and after surgery by using the NeuroKinect system and the camptocormia angle was measured using the camptoapp. RESULTS: After surgery, patient 1 improved 29 points in the UPDRS-III. His camptocormia angle was 68° before and 38° after surgery. Arm and knee angular amplitudes (117.32 ±â€¯7.47 vs 134.77 ±â€¯2.70°; 144.51 ±â€¯7.47 vs 169.08 ±â€¯3.27°) and arm swing (3.59 ±â€¯2.66 vs 5.40 ±â€¯1.76 cm) improved when compared with his preoperative measurements. Patient 2 improved 22 points in the UPDRS-III after surgery. Her camptocormia mostly resolved (47° before to 9° after surgery). Gait analysis revealed improvement of stride length (0.29 ±â€¯0.03 vs 0.35 ±â€¯0.03 m), stride width (18.25 ±â€¯1.16 vs 17.9 ±â€¯0.84 cm), step velocity (0.91 ±â€¯0.57 vs 1.33 ±â€¯0.48 m/s), arm swing (4.51 ±â€¯1.01 vs 7.38 ±â€¯2.71 cm) and arm and hip angular amplitudes (131.57 ±â€¯2.45° vs 137.75 ±â€¯3.18; 100.51 ±â€¯1.56 vs 102.18 ±â€¯1.77°) compared with her preoperative results. CONCLUSION: The gait parameters and camptocormia of both patients objectively improved after surgery, as assessed by the two quantitative measurement systems. STN-DBS might have a beneficial effect on controlling axial posturing and gait, being a potential surgical treatment for camptocormia in patients with PD. However, further studies are needed to derive adequate selection criteria for this patient population.


Subject(s)
Deep Brain Stimulation/methods , Gait Analysis/methods , Muscular Atrophy, Spinal/diagnosis , Muscular Atrophy, Spinal/therapy , Parkinson Disease/diagnosis , Parkinson Disease/therapy , Spinal Curvatures/diagnosis , Spinal Curvatures/therapy , Aged , Female , Gait/physiology , Humans , Male , Middle Aged , Muscular Atrophy, Spinal/complications , Parkinson Disease/complications , Spinal Curvatures/complications
SELECTION OF CITATIONS