1.
Ann Ig ; 36(4): 487-497, 2024.
Article in English | MEDLINE | ID: mdl-38545674

ABSTRACT

Introduction: The correct method of surface disinfection in hospitals is an essential tool in the fight against the spread of healthcare-associated infections caused by multi-resistant microorganisms. Currently, there are many disinfectants on the market that can be used against different microorganisms. However, the effectiveness of different active molecules is controversial in the literature. Study design: The aim of this study was to evaluate the effectiveness of wipes based on hydrogen peroxide (1.0 %) and highly specific plant-based surfactants, contained in H2O2TM (Hi-speed H2O2TM) products, against some hospital-associated microorganisms. Methods: The effectiveness of the wipes was tested against nosocomial and control strains of methicillin-resistant Staphylococcus aureus, carbapenem-resistant Pseudomonas aeruginosa, Klebsiella pneumoniae carbapenemase, Aspergillus fumigatus and Candida parapsilosis. Specifically, in vitro activity was assessed using three different techniques: stainless steel surface testing, surface diffusion testing and well diffusion test. Results: The three different methods tested confirm the wipes' good effectiveness against the most common multi-resistant bacteria and against fungi. Conclusions: These data show that the tested wipes could be a valid adjunct to the disinfection process and could assist in the prevention of healthcare-associated infections.


Subject(s)
Cross Infection , Disinfectants , Disinfection , Hydrogen Peroxide , Disinfection/methods , Hydrogen Peroxide/pharmacology , Cross Infection/prevention & control , Disinfectants/pharmacology , Humans , Health Facilities , Surface-Active Agents/pharmacology , Methicillin-Resistant Staphylococcus aureus/drug effects
2.
Acta Biomed ; 94(S3): e2023217, 2023 08 30.
Article in English | MEDLINE | ID: mdl-37773490

ABSTRACT

BACKGROUND AND AIM: Legionnaires' disease is a severe form of pneumonia caused by the inhalation or aspiration of water droplets contaminated with Legionella pneumophila and other Legionella species. These bacteria are commonly found in natural habitats and man-made water systems. Legionnaires' disease is a significant public health problem, especially in healthcare settings where patients may be exposed to contaminated environmental sources. Nosocomial outbreaks have been reported worldwide, leading to high morbidity and mortality rates, and increased healthcare costs. This study aimed to compare, the clonal relationship of clinical L. pneumophila strains from two different hospitals with L. pneumophila strains isolated from the water supply. METHODS: In the period from 2019 to 2021, clinical and environmental strains involved in three cases of legionellosis were compared by means of pulsed field gel electrophoresis and sequence based typing techniques. RESULTS: Our findings highlight the persistence of clonally distinct strains within each hospital examined. Furthermore, the L. pneumophila strains detected from hospital environmental sources were related to the clinical strains isolated, demonstrating the nosocomial origin of these cases. CONCLUSIONS: Therefore, it is important to implement more accurate surveillance systems both for epidemiological studies and to check the effectiveness of remediation procedures. (www.actabiomedica.it).


Subject(s)
Cross Infection , Legionella pneumophila , Legionnaires' Disease , Humans , Legionnaires' Disease/diagnosis , Legionnaires' Disease/epidemiology , Legionnaires' Disease/microbiology , Cross Infection/epidemiology , Cross Infection/microbiology , Legionella pneumophila/genetics , Water Supply , Water
3.
Article in English | MEDLINE | ID: mdl-37107839

ABSTRACT

The consumption of hot drinks dispensed from vending machines has become a common practice, both in workplaces and during free time. Every day, millions of bulk drinks are sold, but the quality of the products distributed may not always be guaranteed, as it is related to many factors such as the quality of the water, the raw materials used, and the effectiveness of the equipment's cleaning system. The purpose of this study is to evaluate the hygienic-sanitary requirements of hot drinks and vending machine surfaces. The investigation highlighted the microbial contamination of both coffee and vending machine surfaces. Although the "coffee break" is usually considered a moment of pleasure, apparently not subject to specific jurisdiction, the products dispensed can represent a health risk if the hygienic conditions are not fully respected. Therefore, official controls carried out by the Prevention Department represent a suitable way for evaluating and guaranteeing the hygienic-sanitary requirements, providing for corrective actions, when needed, to protect consumers.


Subject(s)
Coffee , Food Dispensers, Automatic
4.
Environ Monit Assess ; 195(4): 496, 2023 Mar 22.
Article in English | MEDLINE | ID: mdl-36947259

ABSTRACT

Understanding the actual distribution of different Legionella species in water networks would help prevent outbreaks. Culture investigations followed by serological agglutination tests, with poly/monovalent antisera, still represent the gold standard for isolation and identification of Legionella strains. However, also MALDI-TOF and mip-gene sequencing are currently used. This study was conducted to genetically correlate strains of Legionella non pneumophila (L-np) isolated during environmental surveillance comparing different molecular techniques. Overall, 346 water samples were collected from the water system of four pavilions located in a hospital of the Apulia Region of Italy. Strains isolated from the samples were then identified by serological tests, MALDI-TOF, and mip-gene sequencing. Overall, 24.9% of water samples were positive for Legionella, among which the majority were Legionella pneumophila (Lpn) 1 (52.3%), followed by Lpn2-15 (20.9%), L-np (17.4%), Lpn1 + Lpn2-15 (7.1%), and L-np + Lpn1 (2.3%). Initially, L-np strains were identified as L. bozemanii by monovalent antiserum, while MALDI-TOF and mip-gene sequencing assigned them to L. anisa. More cold water than hot water samples were contaminated by L. anisa (p < 0.001). PFGE, RAPD, Rep-PCR, and SAU-PCR were performed to correlate L. anisa strains. Eleven out of 14 strains identified in all four pavilions showed 100% of similarity upon PFGE analysis. RAPD, Rep-PCR, and SAU-PCR showed greater discriminative power than PFGE.


Subject(s)
Environmental Monitoring , Hospitals , Water Microbiology , Water Supply , Environmental Monitoring/methods , Italy , Microbiological Techniques/standards , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Legionella/genetics , Legionella/isolation & purification , Sequence Analysis, DNA
5.
Article in English | MEDLINE | ID: mdl-35742328

ABSTRACT

Aspergillosis is a disease caused by Aspergillus, and invasive pulmonary aspergillosis (IPA) is the most common invasive fungal infection leading to death in severely immuno-compromised patients. The literature reports Aspergillus co-infections in patients with COVID-19 (CAPA). Diagnosing CAPA clinically is complex since the symptoms are non-specific, and performing a bronchoscopy is difficult. Generally, the microbiological diagnosis of aspergillosis is based on cultural methods and on searching for the circulating antigens galactomannan and 1,3-ß-D-glucan in the bronchoalveolar lavage fluid (bGM) or serum (sGM). In this study, to verify whether the COVID-19 period has stimulated clinicians to pay greater attention to IPA in patients with respiratory tract infections, we evaluated the number of requests for GM-Ag research and the number of positive tests found during the pre-COVID-19 and COVID-19 periods. Our data show a significant upward trend in GM-Ag requests and positivity from the pre-COVID to COVID period, which is attributable in particular to the increase in IPA risk factors as a complication of COVID-19. In the COVID period, parallel to the increase in requests, the number of positive tests for GM-Ag also increased, going from 2.5% in the first period of 2020 to 12.3% in the first period of 2021.


Subject(s)
COVID-19 , Invasive Pulmonary Aspergillosis , Pulmonary Aspergillosis , Aspergillus , Bronchoalveolar Lavage Fluid , COVID-19/epidemiology , Humans , Invasive Pulmonary Aspergillosis/complications , Invasive Pulmonary Aspergillosis/diagnosis , Invasive Pulmonary Aspergillosis/epidemiology , Pulmonary Aspergillosis/complications , Pulmonary Aspergillosis/diagnosis , Pulmonary Aspergillosis/epidemiology , Sensitivity and Specificity
6.
Pathogens ; 11(5)2022 May 23.
Article in English | MEDLINE | ID: mdl-35631128

ABSTRACT

Awareness of the importance of the microbial contamination of air and surfaces has increased significantly during the COVID-19 pandemic. The aim of this study was to evaluate the presence of bacteria and fungi in the air and on surfaces within some critical areas of large supermarkets with and without an ozonation system. Surveys were conducted in four supermarkets belonging to the same commercial chain of an Apulian city in June 2021, of which two (A and B) were equipped with an ozonation system, and two (C and D) did not have any air-diffused remediation treatment. There was a statistically significant difference in the total bacterial count (TBC) and total fungal count (TFC) in the air between A/B and C/D supermarkets (p = 0.0042 and p = 0.0002, respectively). Regarding surfaces, a statistically significant difference in TBC emerged between A/B and C/D supermarkets (p = 0.0101). To the best of our knowledge, this is the first study evaluating the effect of ozone on commercial structures in Italy. Future investigations, supported by a multidisciplinary approach, will make it possible to deepen the knowledge on this method of sanitation, in light of any other epidemic/pandemic waves.

7.
Article in English | MEDLINE | ID: mdl-35457735

ABSTRACT

Healthcare-related infections are sustained by various bacteria and fungi. In recent years, various technologies have emerged for the sanitation of healthcare-related environments. This study evaluated the effectiveness of a no-touch disinfection system that aerosolizes 5% hydrogen peroxide and 10% ethyl alcohol. After selecting an environment, the Total Bacterial Count and the Total Fungal Count in the air and on a surface of the room were determined to evaluate the effectiveness of the aerosolization system. In addition, sterile stainless-steel plates inoculated with S. aureus, P. aeruginosa, and Aspergillus spp. isolated from hospitalized patients and reference strains were used to evaluate the effectiveness of the system. For each organism, three plates were used: A (cleaned), B (not cleaned), and C (control). The A plates were treated with non-ionic surfactant and the aerosolization system, the B plates were subjected to the aerosolization system, and the plates C were positioned outside the room that was sanitized. Following sanitization, air and surface sampling was conducted, after which, swabs were processed for bacterial and fungal enumeration. The results showed that the air sanitization system had good efficacy for both bacteria and fungi in the air and on stainless-steel plates, particularly for the A plates.


Subject(s)
Disinfectants , Disinfection , Aerosols , Bacteria , Delivery of Health Care , Disinfection/methods , Ethanol , Humans , Hydrogen Peroxide , Pseudomonas aeruginosa , Stainless Steel , Staphylococcus aureus
8.
Pathogens ; 11(1)2022 Jan 17.
Article in English | MEDLINE | ID: mdl-35056056

ABSTRACT

The Mycobacteriumabscessus complex (MABC) is a group of rapidly growing, nontuberculous mycobacteria that are ubiquitous in soil, urban water pipes, swimming pools, and drinking water. Members of the MABC are considered opportunistic pathogens. The aim of this study was to investigate the origins of MABC detected in broncho-lavage (BL) samples from asymptomatic cancer patients. We turned our attention to washing and disinfection procedures for bronchoscopes; we also assessed water and disinfectant samples. Of 10 BL and 34 environmental samples tested, four BL samples (40%) and seven environmental samples (20.6%) tested positive for MABC. We hypothesized that contamination could arise from the prewashing machine and/or the water used because no patient had clinical or radiological signs consistent with MABC respiratory tract infection. Our study highlights the importance of evaluating cleaning and disinfection procedures for endoscope channels to reduce the potential spread of microorganisms and artefactual results arising from contamination.

9.
Article in English | MEDLINE | ID: mdl-34769932

ABSTRACT

Although direct contact is considered the main mode of transmission of SARS-CoV-2, environmental factors play an important role. In this study, we evaluated the presence of SARS-CoV-2 on bus and train surfaces. From the buses, we took samples from the following areas: handrails used to enter or exit the bus, stop request buttons and handles next to the seats. From the trains, the sampled surfaces were handrails used to enter or exit the train, door open/close buttons, handles next to the seats, tables and toilet handles. SARS-CoV-2 was detected on 10.7% of the tested surfaces overall, 19.3% of bus surfaces and 2% of train surfaces (p < 0.0001). On the buses, the most contaminated surfaces were the handles near the seats (12.8%), followed by door open/close buttons (12.5%) and handrails (10.5%). Of the five analyzed transport companies, bus companies were the most contaminated, in particular, companies C (40%) and B (23.3%). A greater number of positive samples were found among those taken at 10:00 a.m. and 10:55 a.m. (45% and 40%, respectively). The presence of the virus on many bus surfaces highlights how the sanitation systems on public transport currently in use are not sufficient to limit the spread of SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Motor Vehicles , Sanitation , Transportation
10.
Article in English | MEDLINE | ID: mdl-34639592

ABSTRACT

As a complement to clinical disease surveillance, the monitoring of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in wastewater can be used as an early warning system for impending epidemics. This study investigated the dynamics of SARS-CoV-2 in untreated wastewater with respect to the trend of coronavirus disease 2019 (COVID-19) prevalence in Southern Italy. A total of 210 wastewater samples were collected between May and November 2020 from 15 Apulian wastewater treatment plants (WWTP). The samples were concentrated in accordance with the standard of World Health Organization (WHO, Geneva, Switzerland) procedure for Poliovirus sewage surveillance, and molecular analysis was undertaken with real-time reverse-transcription quantitative PCR (RT-(q) PCR). Viral ribonucleic acid (RNA) was found in 12.4% (26/210) of the samples. The virus concentration in the positive samples ranged from 8.8 × 102 to 6.5 × 104 genome copies/L. The receiver operating characteristic (ROC) curve modeling showed that at least 11 cases/100,000 inhabitants would occur after a wastewater sample was found to be positive for SARS-CoV-2 (sensitivity = 80%, specificity = 80.9%). To our knowledge, this is the first study in Italy that has applied wastewater-based epidemiology to predict COVID-19 prevalence. Further studies regarding methods that include all variables (meteorological phenomena, characteristics of the WWTP, etc.) affecting this type of wastewater surveillance data would be useful to improve data interpretation.


Subject(s)
COVID-19 , Humans , Italy/epidemiology , SARS-CoV-2 , Sewage , Wastewater
11.
Article in English | MEDLINE | ID: mdl-34501993

ABSTRACT

Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) emerged in March 2020 in Italy, leading to the pandemic of coronavirus disease 2019 (COVID-19) that continues to cause high global morbidity and mortality in human populations. Numerous studies have focused on the spread and persistence of the virus in the hospital setting. New scientific evidence shows that SARS-CoV-2 is present in different community environments. Although aerosol is one of the main routes of transmission for SARS-CoV-2, indirect contact through virus-contaminated surfaces could also play a key role. The survival and persistence of SARS-CoV-2 on surfaces appear to be influenced by the characteristics of the material, temperature, and humidity. In this study, we investigated the presence of SARS-CoV-2 RNA on surfaces in 20 supermarkets throughout the Apulia region during the lockdown period. We collected a total of 300 swab samples from various surfaces including supermarket scales, trolley handles, refrigerator and freezer handles, and keyboards. In total, 13 (4.3%) surfaces were positive for SARS-CoV-2 RNA contamination, with shopping trolley handles being the most frequently contaminated. This study showed that contamination in public spaces can occur, so we remark the importance to adopt adequate preventive measures, including environment ventilation, careful surfaces sanitation, hand hygiene, and correct usage of masks, to reduce the likelihood of virus transmission.


Subject(s)
COVID-19 , SARS-CoV-2 , Communicable Disease Control , Humans , RNA, Viral , Supermarkets
12.
Article in English | MEDLINE | ID: mdl-34574734

ABSTRACT

Serratia marcescens (SM) is a Gram-negative bacterium that is frequently found in the environment. Since 1913, when its pathogenicity was first demonstrated, the number of infections caused by SM has increased. There is ample evidence that SM causes nosocomial infections in immunocompromised or critically ill patients admitted to the intensive care units (ICUs), but also in newborns admitted to neonatal ICUs (NICUs). In this study, we evaluated the possible genetic correlation by PFGE between clinical and environmental SM strains from NICU and ICU and compared the genetic profile of clinical strains with strains isolated from patients admitted to other wards of the same hospital. We found distinct clonally related groups of SM strains circulating among different wards of a large university hospital. In particular, the clonal relationship between clinical and environmental strains in NICU and ICU 1 was highlighted. The identification of clonal relationships between clinical and environmental strains in the wards allowed identification of the epidemic and rapid implementation of adequate measures to stop the spread of SM.


Subject(s)
Cross Infection , Serratia Infections , Cross Infection/epidemiology , Disease Outbreaks , Electrophoresis, Gel, Pulsed-Field , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Serratia Infections/epidemiology , Serratia marcescens/genetics
13.
Environ Res ; 202: 111649, 2021 11.
Article in English | MEDLINE | ID: mdl-34252427

ABSTRACT

Legionellosis is a severe pneumonia caused by the inhalation of aerosols containing Legionella, Gram-negative bacteria present in the water systems of touristic-recreational facilities. The purpose of this study was to develop a scoring tool to predict the risk of both environmental contamination and Legionnaires' disease cases in such facilities in the Apulia region of southern Italy. We analyzed 47 structural and management parameters/risk factors related to the buildings, water systems, and air conditioning at the facilities. A Poisson regression model was used to compute an overall risk score for each facility with respect to three outcomes: water samples positive for Legionella (risk score range: 7-54), water samples positive for Legionella with an average load exceeding 1000 colony-forming units per liter (CFU/L) (risk score range: 22-179,871), and clinical cases of Legionnaire's disease (risk score range: 6-31). The cut-off values for three outcomes were determined by receiver operating characteristic curves (first outcome, samples positive for Legionella in a touristic-recreational facility: 19; second outcome, samples positive for Legionella in a touristic-recreational facility with an average load exceeding 1000 CFU/L: 2062; third outcome, clinical cases of Legionnaire's disease in a touristic-recreational facility: 22). Above these values, there was a significant probability of observing the outcome. We constructed this predictive model using 70% of a large dataset (18 years of clinical and environmental surveillance) and tested the model on the remaining 30% of the dataset to demonstrate its reliability. Our model enables the assessment of risk for a touristic facility and the creation of a conceptual framework to link the risk analysis with prevention measures.


Subject(s)
Legionella pneumophila , Legionella , Legionellosis , Legionnaires' Disease , Humans , Legionellosis/epidemiology , Legionnaires' Disease/epidemiology , Reproducibility of Results , Risk Assessment , Water Microbiology
14.
Article in English | MEDLINE | ID: mdl-33801099

ABSTRACT

A Coronavirus disease (COVID-19), caused by a new virus called severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), spreads via direct contact through droplets produced by infected individuals. The transmission of this virus can also occur via indirect contact if objects and surfaces are contaminated by secretions from individuals with COVID-19 or asymptomatic carriers. Environmental contamination with SARS-CoV-2 is high in hospital settings; on the contrary, surface contamination in non-healthcare settings is still poorly studied. In this study, the presence of SARS-CoV-2 on the surfaces of 20 tourist-recreational facilities was investigated by performing a total of 100 swabs on surfaces, including refrigerator handles, handrails, counters, tables, and bathroom access doors. Six (6%) swabs from four (20%) tourist-recreational facilities tested positive for SARS-CoV-2; the surfaces that were involved were toilet door handles, refrigerator handles, handrails, and bar counters. This study highlights that SARS-CoV-2 is also present in non-healthcare environments; therefore, in order to limit this worrying pandemic, compliance with behavioral rules and the adoption of preventive and protective measures are of fundamental importance not only in healthcare or work environments but also in life environments.


Subject(s)
COVID-19 , Coronavirus Infections , Humans , Italy/epidemiology , Pandemics , SARS-CoV-2
15.
Pathogens ; 10(1)2021 Jan 16.
Article in English | MEDLINE | ID: mdl-33467059

ABSTRACT

The good installation, as well as commissioning plan, of a water network is a crucial step in reducing the risk of waterborne diseases. The aim of this study was to monitor the microbiological quality of water from a newly built pavilion before it commenced operation. Overall, 91 water samples were tested for coliforms, Escherichia coli, enterococci, Pseudomonas aeruginosa and Legionella at three different times: T0 (without any water treatment), T1 (after treatment with hydrogen peroxide and silver ions at initial concentration of 20 mg/L and after flushing of water for 20 min/day for seven successive days) and T2 (15 days later). Coliforms were detected in 47.3% of samples at T0, 36.3% at T1 and 4.4% at T2. E. coli was isolated in 4.4% of the samples only at T1, while enterococci appeared in 12.1% of the samples at T1 and in 2.2% at T2. P. aeruginosa was isolated in 50.5% of the samples at T0, 29.7% at T1 and 1.1% at T2. Legionella pneumophila serogroup 8 was isolated in 80.2% of the samples at T0, 36.3% at T1 and 2.2% at T2. Our results confirmed the need for a water safety plan in new hospital pavilions to prevent the risk of waterborne diseases.

16.
Environ Res ; 191: 110231, 2020 12.
Article in English | MEDLINE | ID: mdl-32976823

ABSTRACT

The COVID-19 pandemic started in China in early December 2019, and quickly spread around the world. The epidemic gradually started in Italy at the end of February 2020, and by May 31, 2020, 232,664 cases and 33,340 deaths were confirmed. As a result of this pandemic, the Italian Ministerial Decree issued on March 11, 2020, enforced lockdown; therefore, many social, recreational, and cultural centers remained closed for months. In Apulia (southern Italy), all non-urgent hospital activities were suspended, and some wards were closed, with a consequent reduction in the use of the water network and the formation of stagnant water. This situation could enhance the risk of exposure of people to waterborne diseases, including legionellosis. The purpose of this study was to monitor the microbiological quality of the water network (coliforms, E. coli, Enterococci, P. aeruginosa, and Legionella) in three wards (A, B and C) of a large COVID-19 regional hospital, closed for three months due to the COVID-19 emergency. Our study revealed that all three wards' water network showed higher contamination by Legionella pneumophila sg 1 and sg 6 at T1 (after lockdown) compared to the period before the lockdown (T0). In particular, ward A at T1 showed a median value = 5600 CFU/L (range 0-91,000 CFU/L) vs T0, median value = 75 CFU/L (range 0-5000 CFU/L) (p-value = 0.014); ward B at T1 showed a median value = 200 CFU/L (range 0-4200 CFU/L) vs T0, median value = 0 CFU/L (range 0-300 CFU/L) (p-value = 0.016) and ward C at T1 showed a median value = 175 CFU/L (range 0-22,000 CFU/L) vs T0, median value = 0 CFU/L (range 0-340 CFU/L) (p-value < 0.001). In addition, a statistically significant difference was detected in ward B between the number of positive water samples at T0 vs T1 for L. pneumophila sg 1 and sg 6 (24% vs 80% p-value < 0.001) and for coliforms (0% vs 64% p-value < 0.001). Moreover, a median value of coliform load resulted 3 CFU/100 ml (range 0-14 CFU/100 ml) at T1, showing a statistically significant increase versus T0 (0 CFU/100 ml) (p-value < 0.001). Our results highlight the need to implement a water safety plan that includes staff training and a more rigorous environmental microbiological surveillance in all hospitals before occupying a closed ward for a longer than one week, according to national and international guidelines.


Subject(s)
Coronavirus Infections , Legionella pneumophila , Pandemics , Pneumonia, Viral , Betacoronavirus , COVID-19 , China/epidemiology , Escherichia coli , Humans , Italy/epidemiology , SARS-CoV-2 , Water , Water Microbiology , Water Supply
17.
Pathogens ; 9(10)2020 Sep 24.
Article in English | MEDLINE | ID: mdl-32987845

ABSTRACT

Since the last decade, attention towards the occurrence of fungi in potable water has increased. Commensal and saprophytic microorganisms widely distributed in nature are also responsible for causing public health problems. Fungi can contaminate hospital environments, surviving and proliferating in moist and unsterile conditions. According to Italian regulations, the absence of fungi is not a mandatory parameter to define potable water, as a threshold value for the fungal occurrence has not been defined. This study evaluated the occurrence of fungi in potable water distribution systems in hospitals. The frequency of samples positive for the presence of fungi was 56.9%; among them, filamentous fungi and yeasts were isolated from 94.2% and 9.2% of the samples, respectively. The intensive care unit (87.1%) had the highest frequency of positive samples. Multivariable model (p < 0.0001), the variables of the period of the year (p < 0.0001) and type of department (p = 0.0002) were found to be statistically significant, suggesting a high distribution of filamentous fungi in the potable water of hospitals. Further studies are necessary to validate these results and identify the threshold values of fungi levels for different types of water used for various purposes to ensure the water is safe for consumption and protect public health.

18.
Article in English | MEDLINE | ID: mdl-32664624

ABSTRACT

In recent years, the chaotic habits of modern life have favored the consumption of quickly prepared meals, using ready-to-eat (RTE) foods and condiments. The aim of this study was to establish the microbiological safety of RTE sauces and pesto from markets analyzed at different stages of shelf life. In the bacterial investigation, all samples were shown to be acceptable, although differences were observed concerning shelf life times. On the other hand, the fungal investigation showed frequent positive results, with concentrations higher than threshold values. Detected microbial diffusion was the lowest when products were far from the expiry date and had just been opened, while high microbial proliferation was observed when analyzing the same package after 48 h, higher than for a product close to the end of its shelf life. This study highlights the discreet microbiological quality of processed and RTE foods, underlining the importance of hygienic-sanitary surveillance of these foods to their shelf life. Consequently, it is necessary to: (1) implement a food control plan for all food categories to carry out risk analysis associated with their consumption; and (2) better adapt the regulations relating to microbiological analysis, and understand the biological significance of each microbial parameter throughout the shelf life of foods.


Subject(s)
Consumer Product Safety , Food Contamination/analysis , Food Microbiology , Food Preservation/methods , Hygiene , Colony Count, Microbial , Humans , Listeria monocytogenes , Quality Control , Surveys and Questionnaires
19.
Article in English | MEDLINE | ID: mdl-32187971

ABSTRACT

The impact of waste incinerators is usually examined by measuring environmental pollutants. Biomonitoring has been limited, until now, to few metals and to adults. We explored accumulation of a comprehensive panel of metals in children free-living in an urban area hosting two waste incinerators. Children were divided by georeferentiation in exposed and control groups, and toenail concentrations of 23 metals were thereafter assessed. The percentage of children having toenail metal concentrations above the limit of detection was higher in exposed children than in controls for Al, Ba, Mn, Cu, and V. Exposed children had higher absolute concentrations of Ba, Mn, Cu, and V, as compared with those living in the reference area. The Tobit regression identified living in the exposed area as a significant predictor of Ba, Ni, Cu, Mn, and V concentrations, after adjusting for covariates. The concentrations of Ba, Mn, Ni, and Cu correlated with each other, suggesting a possible common source of emission. Exposure to emissions derived from waste incinerators in an urban setting can lead to body accumulation of specific metals in children. Toenail metal concentration should be considered a noninvasive and adequate biomonitoring tool and an early warning indicator which should integrate the environmental monitoring of pollutants.


Subject(s)
Biological Monitoring , Environmental Pollutants , Incineration , Metals, Heavy , Adult , Child , Environmental Exposure , Environmental Monitoring , Humans , Metals , Urban Population
20.
Environ Res ; 178: 108721, 2019 11.
Article in English | MEDLINE | ID: mdl-31541805

ABSTRACT

Legionella is the causative agent of Legionnaires' disease, a flu-like illness normally acquired following inhalation or aspiration of contaminated water aerosols. Our recent studies revealed that climatic parameters can increase the number of reported cases of community-acquired Legionnaires' disease. Here, we evaluated the presence of Legionella in water networks and the distribution of Legionnaires' disease cases associated with touristic-recreational facilities in the Apulia region (southern Italy) during the period 2001-2017 using geostatistical and climatic analyses. Geostatistical analysis data revealed that the area with the highest concentration of Legionella in water systems also had the greatest number of cases of Legionnaires' disease associated with touristic-recreational facilities. Climatic analysis showed that higher daily temperature excursion (difference between maximum and minimum temperature) on the day of sampling was more often associated with Legionella-positive samples than Legionella-negative samples. In addition, our data highlighted an increased risk of Legionnaires' disease with increases in precipitation and average temperature and with decreases in daily temperature excursion (difference between maximum and minimum temperature over the course of 24 h in the days of incubation period of disease) and minimum temperature. Healthcare professionals should be aware of this phenomenon and be particularly vigilant for cases of community-acquired pneumonia during such climatic conditions and among the tourist population. The innovative geo-statistical approach used in this study could be applied in other contexts when evaluating the effects of climatic conditions on the incidence of Legionella infections.


Subject(s)
Environmental Exposure/statistics & numerical data , Legionellosis/epidemiology , Climate , Humans , Italy/epidemiology , Legionella , Legionella pneumophila , Legionnaires' Disease , Water Microbiology