1.
Endosc Int Open ; 12(6): E740-E749, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38847015

ABSTRACT

Background and study aims Endoscopic ultrasound (EUS)-guided transmural (TM) deployment of lumen-apposing metal stents (LAMS) is considered relatively safe in non-cirrhotic patients and is cautiously offered to cirrhotic patients. Patients and methods This was a retrospective, multicenter, international matched case-control study to study the safety of EUS-guided TM deployment of LAMS in cirrhotic patients. Results Forty-three cirrhotic patients with model for end-stage liver disease score 12.5 ± 5, with 23 having ascites and 16 with varices underwent EUS-guided TM LAMS deployment, including 19 for pancreatic fluid collection (PFC) drainage, 13 gallbladder drainage, six for endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP), three for EDGI, one for endoscopic ultrasound-directed transenteric ERCP, and one postsurgical collection drainage. Technical failure occurred in one LAMS for PFC drainage. Clinical failure was encountered in another PFC. Nine adverse events (AEs) occurred. The most common AE was LAMS migration (3), followed by non-bleeding mucosal erosion (2), delayed bleeding (2), sepsis (1), and anesthesia-related complication (pulseless electrical activity) (1). Most AEs were graded as mild (6), followed by severe (2), and moderate (1); the majority were managed conservatively. On univariable comparison, risk of AE was higher when using a 20 × 10 mm LAMS and the absence of through-the-LAMS plastic stent(s). Conditional logistic regression of matched case-control patients did not show any association between potential predicting factors and occurrence of AEs. Conclusions Our study demonstrated that mainly in patients with Child-Pugh scores A and B cirrhosis and despite the presence of mild-to-moderate ascites in over half of cases, the majority of AEs were mild and could be managed conservatively. Further studies are warranted to verify the safety of LAMS in cirrhotic patients.

3.
Gastrointest Endosc ; 99(2): 237-244.e1, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37536633

ABSTRACT

BACKGROUND AND AIMS: Mucosal closure adds time but reduces adverse events associated with endoscopic submucosal dissection (ESD). We aimed to assess the closure time (CT), technical success, and cost-effectiveness between a novel through-the-scope helix tack suture system (TTSS) and the over-the-scope suturing system (OTSS). METHODS: In this single-center, prospective, randomized trial, all patients undergoing ESD with anticipated closure were randomized 1:1 to TTSS (study group) or OTSS (control group). Primary outcomes were CT and overall CT (OCT; CT + setup time). Secondary outcomes were rates of technical success, adverse events, and cost-effectiveness. RESULTS: Forty patients were randomized to OTSS (n = 20) or TTSS (n = 20). OTSS and TTSS groups were similar with respect to age, gender, proportion of colorectal polyps, proximal colon polyps, and mean size of the resected specimen (40.9 mm vs 40.4 mm). The mean CT was 18.4 minutes for OTSS and 23.3 minutes for TTSS (P = .36). The mean OCT was 32 minutes for OTSS and 39.5 minutes for TTSS (P = .36). Closure with a primary device was successful in 17 cases (85%) with OTSS and 18 cases (90%) with TTSS (P = .63). No closure-related intraprocedural adverse events or delayed perforations were noted. Mean cost of closure was significantly lower in the TTSS group for lesions <35 mm (P = .008). CONCLUSIONS: TTSS was not found to be superior to OTSS with respect to CT and technical and clinical success for closure of gastric and colorectal ESD defects. TTSS is more cost-effective for closure of lesions <35 mm. (Clinical trial registration number: NCT04925271.).


Subject(s)
Colorectal Neoplasms , Endoscopic Mucosal Resection , Humans , Endoscopic Mucosal Resection/methods , Prospective Studies , Stomach , Colorectal Neoplasms/surgery , Colorectal Neoplasms/etiology , Sutures , Treatment Outcome , Retrospective Studies
4.
ACG Case Rep J ; 10(12): e01214, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38089535

ABSTRACT

Endoscopic full-thickness resection using a full-thickness resection device is a newer technique for endoscopic removal of submucosal lesions not amenable to endoscopic mucosal resection or endoscopic submucosal dissection. There is a low rate of complications reported, although we report 2 cases of delayed perforation caused by dislodgement of a full-thickness resection device clip after removal of scarred gastric lesions. Both were managed endoscopically with good outcomes. However, special attention and consideration of alternative closure techniques should be considered with scarred gastric lesions and possible changes to the clip design could be considered.

5.
J Clin Gastroenterol ; 2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37646532

ABSTRACT

BACKGROUND: Endoscopic ultrasound (EUS)-guided gastroenterostomy (EUS-GE) is a minimally invasive therapy for patients with gastric outlet obstruction without the risks of surgical bypass and the limited long-term efficacy of enteral self-expanding metal stent placement. However, due to its novelty, there is a lack of significant data comparing long-term outcomes of patients with EUS-GE, based on the underlying disease. In this study, we compare outcomes of EUS-GE on benign versus malignant indications. METHODS: Consecutive patients from 12 international, tertiary care centers who underwent EUS-GE over 3 years were extracted in a retrospective registry. Demographic characteristics, procedure-related information and follow-up data was collected. Primary outcome was the rate of adverse events associated with EUS-GE and the comparison of the rate of adverse events in benign versus malignant diseases. Secondary outcomes included technical and clinical success as well as hospitalization admission. RESULTS: A total of 103 patients were included: 72 malignant and 31 benign. The characteristics of the patients undergoing EUS-GE is shown in Table 1. The mean age of the cohort was 68 years and 58 years for malignant and benign etiology. Gender distribution was 57% and 39% being females in malignant and benign etiology group, respectively. Clinical success, technical success, average procedure time, and hospital length of stay were similar in both groups. Patients with benign underlying etiology had significantly higher number of surgically altered midgut anatomy (P=0.0379). CONCLUSION: EUS-GE is equally efficient regardless of the underlying etiology (malignant vs. benign), and the adverse events both groups were comparable.

6.
J Clin Gastroenterol ; 57(2): 218-226, 2023 02 01.
Article in English | MEDLINE | ID: mdl-33899781

ABSTRACT

BACKGROUND AND AIMS: Endoscopic decompression is considered a first-line treatment for symptomatic pancreatic fluid collections (PFCs). A lumen-apposing metal stent (LAMS) with an electrocautery-enhanced delivery system [electrocautery-enhanced lumen-apposing metal stent (ELAMS)] may facilitate this procedure. This study evaluated the safety and efficacy of ELAMS in the management of symptomatic PFCs. PATIENTS AND METHODS: A multicenter, nonblinded, prospective, Food and Drug Administration (FDA)-approved, investigational device exemption clinical trial was conducted. Enrollment criteria included symptomatic PFCs ≥6 cm with ≥70% fluid fraction. Subjects were followed prospectively for safety, efficacy, and resolution of the collections. Primary endpoint success was defined as ≥50% reduction in PFC size. Clinical outcomes were compared with our previously published series of LAMS without the cautery-enhanced delivery system. RESULTS: The target enrollment of 30 patients was achieved in 7 US tertiary care centers. All patients underwent successful placement of the ELAMS. The mean procedure duration, stent placement time, and fluoroscopy exposures were 28.1±12.5, 5.8±2.6, and 1.8±1.6 minutes, respectively. Eight patients had no fluoroscopy. The primary endpoint was achieved in 83.3% of patients. Two adverse events were attributed to the ELAMS: 1 bleeding upon stent removal and 1 stent migration. Relative to the comparator noncautery LAMS multicenter trial (N=33, 8 tertiary centers), there was a significantly shorter procedure duration [36 min ( P <0.001)] with similar technical and clinical outcomes in the ELAMS cohort. CONCLUSION: LAMS placed using an electrocautery delivery system significantly reduce procedure duration and were safe and effective in the management of symptomatic PFCs.


Subject(s)
Decompression, Surgical , Pancreatic Diseases , Humans , Drainage/methods , Electrocoagulation , Endosonography , Lumbar Vertebrae/surgery , Metals/adverse effects , Pancreatic Diseases/surgery , Prospective Studies , Stents/adverse effects
7.
J Clin Gastroenterol ; 57(8): 798-803, 2023 09 01.
Article in English | MEDLINE | ID: mdl-35997700

ABSTRACT

INTRODUCTION: Single-use disposable duodenoscopes (SDD) have been developed to mitigate infectious risks related to reusable duodenoscopes. The aim of this study is to compare the safety and efficacy of the two available SDDs in the United States. METHODS: We conducted a comparative study of 2 SDD in consecutive ERCP procedures performed by expert endoscopists from 9 academic centers. Performance ratings, procedure details, and adverse events were collected. RESULTS: A total of 201 patients were included: 129 patients underwent ERCP with Exalt (mean age 63, Males- 66 (51%), 72 with aScope Duodeno (mean age 65, males=30 (42%). A majority of endoscopists had performed >2000 ERCPs in both groups (71% Exalt, 93% aScope Duodeno). Technical success was 92% in both groups (n=119 Exalt-group, n=66 aScope-Duodeno-group). The procedural complexity for the ERCP cases performed were: Grade 1: 35 cases (18%), Grade 2: 83 cases (41%), Grade 3: 65 cases (32%), and Grade 4: 18 cases (9%). Thirteen patients (10%) from the Exalt group and 16 patients (22%) from the aScope Duodeno group required conversion to a reusable duodenoscope. On a scale of 1 to 5, Exalt and aScope Duodeno, respectively, were rated: 2.31 versus 2.60 for location and visualization quality, 1.38 versus 1.57 for maneuverability based on papillary orientation, 1.48 versus 1.15 for suction/air control, and 2.31 versus 2.34 for elevator efficiency. None of the adverse events were related to the SDDs. CONCLUSIONS: The 2 SDDs were comparable. Further ongoing enhancements to these devices will improve maneuverability and clinical effectiveness.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Duodenoscopes , Male , Humans , Middle Aged , Aged , Duodenoscopes/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/adverse effects
8.
Ann Gastroenterol ; 34(2): 273-281, 2021.
Article in English | MEDLINE | ID: mdl-33654370

ABSTRACT

BACKGROUND: To compare fully covered bi-flanged metal stents (BFMS) and lumen-apposing metal stents (LAMS) for endoscopic ultrasound (EUS)-guided drainage/debridement of pancreatic walled-off necrosis (WON). METHODS: Patients with WON managed by EUS-guided therapy were divided into those who underwent: 1) drainage using BFMS; and 2) drainage using LAMS and scheduled direct endoscopic necrosectomy (DEN). Clinical success (resolution of the WON), technical success (successful stent placement), and adverse events (AEs) were evaluated. RESULTS: 387 patients underwent WON endoscopic drainage, 205 using BFMS and 182 using LAMS. The clinical success in the BFMS or LAMS groups were similar (197 [96.1%] vs. 174 [95.6%]; P=0.81). Median number of procedures required for WON resolution was significantly lower in BFMS compared to LAMS (2 vs. 3, P<0.001). Technical success for stent placement was similar in BFMS and LAMS groups (203 [99%] vs. 180 [99%], P=0.90). Procedure-related AEs were similar in the BFMS and LAMS groups (19 [9.3%] vs. 20 [10.9%], P=0.61). Stent dysfunction with occluding debris was higher in the BFMS group compared to LAMS group (21 [10.2 %] vs. 11 [5.9%], P=0.04). The migration rate was higher in the BFMS group than in the LAMS group (15 [7.3%] vs. 3 [1.6%]; P<0.001). DEN was required in 23 [11.2%] patients in the BFMS group after lack of WON resolution by conservative means. CONCLUSION: BFMS with a "step-up approach" and LAMS with scheduled DEN are both safe and effective for EUS-guided drainage/debridement of WON.

9.
Endoscopy ; 53(6): 611-618, 2021 06.
Article in English | MEDLINE | ID: mdl-32882722

ABSTRACT

BACKGROUND: Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP; EDGE) is an alternative to enteroscopy- and laparoscopy-assisted ERCP in patients with Roux-en-Y gastric bypass anatomy. Although short-term results are promising, the long-term outcomes are not known. The aims of this study were: (1) to determine the rates of long-term adverse events after EDGE, with a focus on rates of persistent gastrogastric or jejunogastric fistula; (2) to identify predictors of persistent fistula; (3) to assess the outcomes of endoscopic closure when persistent fistula is encountered. METHODS: This was a multicenter retrospective study involving 13 centers between February 2015 and March 2019. Adverse events were defined according to the ASGE lexicon. Persistent fistula was defined as an upper gastrointestinal series or esophagogastroduodenoscopy showing evidence of fistula. RESULTS: 178 patients (mean age 58 years, 79 % women) underwent EDGE. Technical success was achieved in 98 % of cases (175/178), with a mean procedure time of 92 minutes. Periprocedural adverse events occurred in 28 patients (15.7 %; mild 10.1 %, moderate 3.4 %, severe 2.2 %). The four severe adverse events were managed laparoscopically. Persistent fistula was diagnosed in 10 % of those sent for objective testing (9/90). Following identification of a fistula, 5 /9 patients underwent endoscopic closure procedures, which were successful in all cases. CONCLUSIONS: The EDGE procedure is associated with high clinical success rates and an acceptable risk profile. Persistent fistulas after lumen-apposing stent removal are uncommon, but objective testing is recommended to identify their presence. When persistent fistulas are identified, endoscopic treatment is warranted, and should be successful in closing the fistula.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Gastric Bypass , Endoscopy, Gastrointestinal , Endosonography , Female , Gastric Bypass/adverse effects , Humans , Male , Middle Aged , Retrospective Studies
10.
Dig Liver Dis ; 51(11): 1557-1561, 2019 11.
Article in English | MEDLINE | ID: mdl-31272934

ABSTRACT

INTRODUCTION: Lumen apposing metal stents (LAMS) have been used increasingly for drainage of pancreatic fluid collections (PFC). We present an international, multicenter study evaluating the safety and efficacy of LAMS in PFCs. METHODS: Consecutive patients undergoing LAMS placement for PFC at 12 international centers were included (ClinicalTrials.gov NCT01522573). Demographics, clinical history, and procedural details were recorded. Technical success was defined as successful LAMS deployment. Clinical success was defined as PFC resolution at three-month follow-up. RESULTS: 192 patients were included (140 males (72.9%), mean-age 53.8 years), with mean follow-up of 4.2 months ±â€¯3.8. Mean PFC size was 11.9 cm (range 2-25). The median number of endoscopic interventions was 2 (range 1-14). Etiologies for PFC were gallstone (n = 82, 42.7%), alcohol (n = 50, 26%), idiopathic (n = 26, 13.5%), and other (n = 34, 17.7%). Technical success was achieved in 189 patients (98.4%). Clinical success was observed in 125 of 135 patients (92.6%). Adverse events included bleeding (n = 11, 5.7), infection (n = 2, 1%), and perforation (n = 2, 1%). Three or more endoscopy sessions were a positive predictor for PFC resolution and the only significant predictor for AEs. CONCLUSION: LAMS has a high technical and clinical success rate with a low rate of AEs. PFC drainage via LAMS provides a minimally invasive, safe, and efficacious procedure for PFC resolution.


Subject(s)
Drainage/instrumentation , Hemorrhage/etiology , Pancreatic Pseudocyst/surgery , Stents/adverse effects , Adult , Aged , Body Fluids , Debridement , Drainage/adverse effects , Endoscopy/methods , Endosonography , Female , Humans , Internationality , Logistic Models , Male , Metals , Middle Aged , Multivariate Analysis , Necrosis/surgery , Pancreas/pathology , Pancreas/surgery , Prospective Studies , Prosthesis Failure , Prosthesis Implantation/adverse effects , Treatment Outcome , Ultrasonography, Interventional
11.
Gastrointest Endosc Clin N Am ; 29(2): 205-214, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30846149

ABSTRACT

Indeterminate biliary strictures pose a diagnostic and therapeutic challenge. Although underlying malignancy is a primary concern, biliary strictures may result from benign processes. An accurate diagnosis is paramount to define the treatment strategy and minimize morbidity. The limitations of traditional endoscopic retrograde cholangiopancreatography-based tissue acquisition with cytology brushings are well-documented. Endoscopic retrograde cholangiopancreatography is generally unable to determine a stricture's etiology. Complementary advanced endoscopic imaging and multimodal tissue acquisition have evolved. Careful consideration of the clinical presentation, location of the stricture, and interpretation of imaging constitute the most optimal approach for diagnosis and management.


Subject(s)
Bile Ducts/pathology , Biliary Tract Diseases/diagnosis , Cholangiopancreatography, Endoscopic Retrograde , Liver Diseases/diagnosis , Pancreatic Diseases/diagnosis , Biliary Tract Diseases/complications , Cholangiopancreatography, Magnetic Resonance , Cholestasis, Intrahepatic/diagnostic imaging , Cholestasis, Intrahepatic/etiology , Constriction, Pathologic/diagnostic imaging , Constriction, Pathologic/etiology , Endosonography , Humans , In Situ Hybridization, Fluorescence , Liver Diseases/complications , Molecular Diagnostic Techniques , Pancreatic Diseases/complications
12.
Gastrointest Endosc ; 89(6): 1160-1168.e9, 2019 06.
Article in English | MEDLINE | ID: mdl-30738985

ABSTRACT

BACKGROUND AND AIMS: Minimum EUS and ERCP volumes that should be offered per trainee in "high quality" advanced endoscopy training programs (AETPs) are not established. We aimed to define the number of procedures required by an "average" advanced endoscopy trainee (AET) to achieve competence in technical and cognitive EUS and ERCP tasks to help structure AETPs. METHODS: American Society for Gastrointestinal Endoscopy (ASGE)-recognized AETPs were invited to participate; AETs were graded on every fifth EUS and ERCP examination using a validated tool. Grading for each skill was done using a 4-point scoring system, and learning curves using cumulative sum analysis for overall, technical, and cognitive components of EUS and ERCP were shared with AETs and trainers quarterly. Generalized linear mixed-effects models with a random intercept for each AET were used to generate aggregate learning curves, allowing us to use data from all AETs to estimate the average learning experience for trainees. RESULTS: Among 62 invited AETPs, 37 AETs from 32 AETPs participated. Most AETs reported hands-on EUS (52%, median 20 cases) and ERCP (68%, median 50 cases) experience before starting an AETP. The median number of EUS and ERCPs performed per AET was 400 (range, 200-750) and 361 (range, 250-650), respectively. Overall, 2616 examinations were graded (EUS, 1277; ERCP-biliary, 1143; pancreatic, 196). Most graded EUS examinations were performed for pancreatobiliary indications (69.9%) and ERCP examinations for ASGE biliary grade of difficulty 1 (72.1%). The average AET achieved competence in core EUS and ERCP skills at approximately 225 and 250 cases, respectively. However, overall technical competence was achieved for grade 2 ERCP at about 300 cases. CONCLUSION: The thresholds provided for an average AET to achieve competence in EUS and ERCP may be used by the ASGE and AETPs in establishing the minimal standards for case volume exposure for AETs during their training. (Clinical trial registration number: NCT02509416.).


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Clinical Competence , Education, Medical, Graduate/standards , Endoscopy, Digestive System/education , Endosonography , Fellowships and Scholarships/standards , Gastroenterology/education , Learning Curve , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Humans , Prospective Studies , Sphincterotomy, Endoscopic/education
13.
Endosc Ultrasound ; 8(3): 194-198, 2019.
Article in English | MEDLINE | ID: mdl-30719997

ABSTRACT

BACKGROUND AND OBJECTIVES: Endoscopic drainage/debridement of symptomatic walled off necrosis (WON) using lumen-apposing metal stents (LAMS) is both safe and effective. While endoscopic management of WON is the standard approach to treatment, the ideal concomitant medical therapy remains unclear. The purpose of this study was to further elucidate the effect of proton pump inhibitor (PPIs) therapy on the technical and clinical success of endoscopic treatment of WON. METHODS: Two hundred and seventy-two patients in 8 centers with WON managed by endoscopic drainage using LAMS were evaluated. Patients were followed for at least 6 months following treatment. The patients were divided into two groups: Those that used PPIs continuously during the therapy and those not on PPIs continuously during the interval of therapy. Outcomes included but were not limited to technical success, clinical success, number of procedures performed, and adverse events. RESULTS: From 2013 to 2016, 272 patients underwent WON drainage with successful transmural LAMS placement. The two groups were split evenly into PPI users and non-PPI users, and matched in regards to demographics, etiology of pancreatitis, WON size, and location. There was no difference in the technical success between the two groups (100% vs. 98.8%, P = 1), or in clinical success rates (78.7% vs. 77.9%). There was a significant difference in the required number of direct endoscopic necrosectomies to achieve clinical success in the PPI vs. non-PPI group (3.2 vs. 4.6 respectively, P < 0.01). There were significantly more cases of stent occlusion in the non-PPI group vs. PPI group (9.5% vs. 20.1% P = 0.012), but all other documented adverse events were not significantly different. CONCLUSION: Discontinuing PPIs during endoscopic drainage and necrosectomy of symptomatic WON appears to reduce the number of endoscopic procedures required to achieve resolution. Continuous PPI results in higher rates of early stent occlusion.

14.
Surg Endosc ; 33(4): 1260-1270, 2019 04.
Article in English | MEDLINE | ID: mdl-30209610

ABSTRACT

BACKGROUND: Percutaneous cholecystostomy tube (PTGBD), endoscopic retrograde cholangiopancreatography with transpapillary gallbladder drainage (TP), and endoscopic ultrasound-guided transmural gallbladder drainage (EGBD) using lumen-apposing metal stents (LAMS) have been offered for gallbladder decompression for acute cholecystitis in high-risk surgical patients. Yet, there are limited data comparing these therapies. Our aim was to compare the safety and efficacy of EGBD to TP and PTGBD for gallbladder drainage. METHODS: We retrospectively collected high-risk surgical patients from six centers with acute cholecystitis who underwent gallbladder drainage by EGBD, TP, or PTGBD. Data included technical success (gallbladder drainage), clinical success (acute cholecystitis resolution), adverse events (AE), and follow-up. RESULTS: From 2010 to 2016, 372 patients underwent gallbladder drainage, with 146 by PTGBD, 124 by TP, and 102 drained by EGBD. Technical (98% vs. 88% vs. 94%; p = 0.004) and Clinical (97% vs. 90% vs. 80%; p < 0.001) success rates were significantly higher with PTGBD and EGBD compared to TP. PTGBD group had statistically significantly higher number of complications as compared to EGBD and TP groups (2 0% vs. 2% vs. 5%; p = 0.01). Mean hospital stay in the EGBD group was significantly less than TP and PTGBD (16 vs. 18 vs. 19 days; p = 0.01), while additional surgical intervention was significantly higher in the PTGBD group compared to the EGBD and TP groups (49% vs. 4% vs. 11%; p < 0.0001). CONCLUSIONS: EGBD with LAMS is an effective and safer alternative to TP and PTGBD for treatment of patients with acute cholecystitis who cannot undergo surgery. EGBD with LAMS has significantly lower overall AEs, hospital stay, and unplanned admissions compared to PTGBD. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01522573.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde/methods , Cholecystitis, Acute/surgery , Cholecystostomy/methods , Drainage/methods , Endosonography/methods , Self Expandable Metallic Stents , Adult , Aged , Drainage/adverse effects , Endosonography/instrumentation , Female , Humans , Length of Stay , Male , Middle Aged , Retrospective Studies , Risk Factors
15.
Gastroenterology ; 155(5): 1483-1494.e7, 2018 11.
Article in English | MEDLINE | ID: mdl-30056094

ABSTRACT

BACKGROUND & AIMS: It is unclear whether participation in competency-based fellowship programs for endoscopic ultrasound (EUS) and endoscopic retrograde cholangiopancreatography (ERCP) results in high-quality care in independent practice. We measured quality indicator (QI) adherence during the first year of independent practice among physicians who completed endoscopic training with a systematic assessment of competence. METHODS: We performed a prospective multicenter cohort study of invited participants from 62 training programs. In phase 1, 24 advanced endoscopy trainees (AETs), from 20 programs, were assessed using a validated competence assessment tool. We used a comprehensive data collection and reporting system to create learning curves using cumulative sum analysis that were shared with AETs and trainers quarterly. In phase 2, participating AETs entered data into a database pertaining to every EUS and ERCP examination during their first year of independent practice, anchored by key QIs. RESULTS: By the end of training, most AETs had achieved overall technical competence (EUS 91.7%, ERCP 73.9%) and cognitive competence (EUS 91.7%, ERCP 94.1%). In phase 2 of the study, 22 AETs (91.6%) participated and completed a median of 136 EUS examinations per AET and 116 ERCP examinations per AET. Most AETs met the performance thresholds for QIs in EUS (including 94.4% diagnostic rate of adequate samples and 83.8% diagnostic yield of malignancy in pancreatic masses) and ERCP (94.9% overall cannulation rate). CONCLUSIONS: In this prospective multicenter study, we found that although competence cannot be confirmed for all AETs at the end of training, most meet QI thresholds for EUS and ERCP at the end of their first year of independent practice. This finding affirms the effectiveness of training programs. Clinicaltrials.gov ID NCT02509416.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Clinical Competence , Endosonography , Cholangiopancreatography, Endoscopic Retrograde/standards , Endosonography/standards , Humans , Learning Curve , Prospective Studies , Quality Indicators, Health Care
16.
Endosc Ultrasound ; 7(1): 34-40, 2018.
Article in English | MEDLINE | ID: mdl-29451167

ABSTRACT

BACKGROUND AND OBJECTIVES: The ability to obtain adequate tissue of solid pancreatic lesions by EUS-guided remains a challenge. The aim of this study was to compare the performance characteristics and safety of EUS-FNA for evaluating solid pancreatic lesions using the standard 22-gauge needle versus a novel EUS biopsy needle. METHODS: This was a multicenter retrospective study of EUS-guided sampling of solid pancreatic lesions between 2009 and 2015. Patients underwent EUS-guided sampling with a 22-gauge SharkCore (SC) needle or a standard 22-gauge FNA needle. Technical success, performance characteristics of EUS-FNA, the number of needle passes required to obtain a diagnosis, diagnostic accuracy, and complications were compared. RESULTS: A total of 1088 patients (mean age = 66 years; 49% female) with pancreatic masses underwent EUS-guided sampling with a 22-gauge SC needle (n = 115) or a standard 22-gauge FNA needle (n = 973). Technical success was 100%. The frequency of obtaining an adequate cytology by EUS-FNA was similar when using the SC and the standard needle (94.1% vs. 92.7%, respectively). The sensitivity, specificity, and diagnostic accuracy of EUS-FNA for tissue diagnosis were not significantly different between two needles. Adequate sample collection leading to a definite diagnosis was achieved by the 1st, 2nd, and 3rd pass in 73%, 92%, and 98% of procedures using the SC needle and 20%, 37%, and 94% procedures using the standard needle (P < 0.001), respectively. The median number of passes to obtain a tissue diagnosis using the SC needle was significantly less as compared to the standard needle (1 and 3, respectively; P< 0.001). CONCLUSIONS: The EUS SC biopsy needle is safe and technically feasible for EUS-FNA of solid pancreatic mass lesions. Preliminary results suggest that the SC needle has a diagnostic yield similar to the standard EUS needle and significantly reduces the number of needle passes required to obtain a tissue diagnosis.

17.
Minerva Gastroenterol Dietol ; 64(2): 111-116, 2018 Jun.
Article in English | MEDLINE | ID: mdl-28875690

ABSTRACT

BACKGROUND: Fully-covered self-expandable metal stents (FCSEMS) have been used in benign biliary diseases although reported data is limited. These devices are most commonly used to treat biliary leaks, strictures, or both. The aim of this study was to evaluate effectiveness of FCSEMS in treating benign biliary disease and recognize the associated complications. METHODS: We performed a multicenter longitudinal retrospective cohort study of patients with benign biliary disease needing FCSEMS between 2011 and 2016. Descriptive statistics were performed using SPSS version 24 (SPSS Inc, Chicago, IL, USA) and continuous variables were presented as mean±standard deviation. RESULTS: 75, 57% M/43% F, with a mean age of 58.5±14.9 years, were included. 64 (85%) had benign strictures, 7 patients had leaks, and 4 patients had both a leak and a stricture. Chronic pancreatitis was the most common cause of BBS (47%) and cholecystectomy was the most common cause of leaks. FCSEMS placement was technically successful in all patients. Four patients died of unrelated causes. A recurrent stricture was observed in 24 (32%) of the patients. Recurrent strictures were most commonly seen in patients with chronic pancreatitis 12/35 (34%). Stent migration occurred in 8/75 patients (10.7%). Seven patients (9.3%) had adverse events, acute pancreatitis (N.=4) was most common. CONCLUSIONS: FCSEMS are safe and effective for treating biliary strictures and leaks. We report decreased rates of stent migration compared to previous studies. Prospective studies are needed to compare plastic stents with FCSEMS, determine optimal stent in-dwell times and cost effectiveness of FCSEMS.


Subject(s)
Biliary Tract Diseases/surgery , Self Expandable Metallic Stents , Female , Humans , Longitudinal Studies , Male , Middle Aged , Prosthesis Design , Retrospective Studies
18.
Medicine (Baltimore) ; 96(35): e7900, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28858107

ABSTRACT

Asymptomatic pancreatic cysts are a common clinical problem but only a minority of these cases progress to cancer. Our aim was to compare the accuracy to detect malignancy of the 2015 American Gastroenterological Association (AGA), the 2012 International Consensus/Fukuoka (Fukuoka guidelines [FG]), and the 2010 American College of Radiology (ACR) guidelines.We conducted a retrospective study at 3 referral centers for all patients who underwent resection for an asymptomatic pancreatic cyst between January 2008 and December 2013. We compared the accuracy of 3 guidelines in predicting high-grade dysplasia (HGD) or cancer in resected cysts. We performed logistic regression analyses to examine the association between cyst features and risk of HGD or cancer.A total of 269 patients met inclusion criteria. A total of 228 (84.8%) had a benign diagnosis or low-grade dysplasia on surgical pathology, and 41 patients (15.2%) had either HGD (n = 14) or invasive cancer (n = 27). Of the 41 patients with HGD or cancer on resection, only 3 patients would have met the AGA guideline's indications for resection based on the preoperative cyst characteristics, whereas 30/41 patients would have met the FG criteria for resection and 22/41 patients met the ACR criteria. The sensitivity, specificity, positive predictive value, negative predictive value of HGD, and/or cancer of the AGA guidelines were 7.3%, 88.2%, 10%, and 84.1%, compared to 73.2%, 45.6%, 19.5%, and 90.4% for the FG and 53.7%, 61%, 19.8%, and 88% for the ACR guidelines. In multivariable analysis, cyst size >3 cm, compared to ≤3 cm, (odds ratio [OR] = 2.08, 95% confidence interval [CI] = 1.11, 4.2) and each year increase in age (OR = 1.07, 95% CI = 1.03, 1.11) were positively associated with risk of HGD or cancer on resection.In patients with asymptomatic branch duct-intraductal papillary mucinous neoplasms or mucinous cystic neoplasms who underwent resection, the prevalence rate of HGD or cancer was 15.2%. Using the 2015 AGA criteria for resection would have missed 92.6% of patients with HGD or cancer. The more "inclusive" FG and ACR had a higher sensitivity for HGD or cancer but lower specificity. Given the current deficiencies of these guidelines, it will be important to determine the acceptable rate of false-positives in order to prevent a single true-positive.


Subject(s)
Pancreatic Cyst/diagnosis , Pancreatic Cyst/pathology , Pancreatic Neoplasms/diagnosis , Pancreatic Neoplasms/pathology , Practice Guidelines as Topic/standards , Aged , Aged, 80 and over , Diagnosis, Differential , False Negative Reactions , Female , Humans , Male , Middle Aged , Pancreatic Cyst/surgery , Pancreatic Neoplasms/surgery , Retrospective Studies , Sensitivity and Specificity
20.
Gastrointest Endosc ; 85(4): 758-765, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27566053

ABSTRACT

BACKGROUND AND AIMS: Endoscopic transmural drainage/debridement of pancreatic walled-off necrosis (WON) has been performed using double-pigtail plastic (DP), fully covered self-expanding metal stents (FCSEMSs), or the novel lumen-apposing fully covered self-expanding metal stent (LAMS). Our aim was to perform a retrospective cohort study to compare the clinical outcomes and adverse events of EUS-guided drainage/debridement of WON with DP stents, FCSEMSs, and LAMSs. METHODS: Consecutive patients in 2 centers with WON managed by EUS-guided debridement were divided into 3 groups: (1) those who underwent debridement using DP stents, (2) debridement using FCSEMSs, (3) debridement using LAMSs. Technical success (ability to access and drain a WON by placement of transmural stents), early adverse events, number of procedures performed per patient to achieve WON resolution, and long-term success (complete resolution of the WON without need for further reintervention at 6 months after treatment) were evaluated. RESULTS: From 2010 to 2015, 313 patients (23.3% female; mean age, 53 years) underwent WON debridement, including 106 who were drained using DP stents, 121 using FCSEMSs, and 86 using LAMSs. The 3 groups were matched for age, cause of the pancreatitis, WON size, and location. The cause of the patients' pancreatitis was gallstones (40.6%), alcohol (30.7%), idiopathic (13.1%), and other causes (15.6%). The mean cyst size was 102 mm (range, 20-510 mm). The mean number of endoscopy sessions was 2.5 (range, 1-13). The technical success rate of stent placement was 99%. Early adverse events were noted in 27 of 313 (8.6%) patients (perforation in 6, bleeding in 8, suprainfection in 9, other in 7). Successful endoscopic therapy was noted in 277 of 313 (89.6%) patients. When comparing the 3 groups, there was no difference in the technical success (P = .37). Early adverse events were significantly lower in the FCSEMS group compared with the DP and LAMS groups (1.6%, 7.5%, and 9.3%; P < .01). At 6-month follow-up, the rate of complete resolution of WON was lower with DP stents compared with FCSEMSs and LAMSs (81% vs 95% vs 90%; P = .001). The mean number of procedures required for WON resolution was significantly lower in the LAMS group compared with the FCSEMS and DP groups (2.2 vs 3 vs 3.6, respectively; P = .04). On multivariable analysis, DP stents remain the sole negative predictor for successful resolution of WON (odds ratio [OR], 0.18; 95% confidence interval, 0.06-0.53; P = .002) after adjusting for age, sex, and WON size. Although there was no significant difference between FCSEMSs and LAMSs for WON resolution, the LAMS was more likely to have early adverse events (OR, 6.6; P = .02). CONCLUSIONS: EUS-guided drainage/debridement of WON using FCSEMSs and LAMSs is superior to DP stents in terms of overall treatment efficacy. The number of procedures required for WON resolution was significantly lower with LAMSs compared with FCSEMSs and DP stents.


Subject(s)
Drainage/instrumentation , Endoscopy, Digestive System/methods , Pancreas/pathology , Pancreatic Diseases/surgery , Plastics , Self Expandable Metallic Stents , Stents , Adult , Aged , Anastomosis, Surgical , Cholangiopancreatography, Magnetic Resonance , Cohort Studies , Duodenostomy , Female , Gastrostomy , Humans , Male , Middle Aged , Necrosis , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS