Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
J Clin Med ; 10(17)2021 Sep 02.
Article in English | MEDLINE | ID: mdl-34501432

ABSTRACT

The study aims to evaluate the effectiveness of foot revascularization in persons with diabetic foot ulcers (DFUs) and below-the-ankle (BTA) arterial disease. Consecutive patients referred for a new active ischaemic DFU requiring lower limb revascularization were considered. Among those, only patients with a BTA arterial disease were included. Revascularization procedures were retrospectively analysed: in the case of successful foot revascularization (recanalization of pedal artery, or plantar arteries or both) or not, patients were respectively divided in two groups, successful foot perfusion (SFP) and failed foot perfusion (FFP). Healing, minor and major amputation at 12 months of follow-up were evaluated and compared. Eighty patients (80) were included. The mean age was 70.5 ± 10.9 years, 55 (68.7%) were male, 72 (90%) were affected by type 2 diabetes with a mean duration of 22.7 ± 11.3 years. Overall 45 (56.2%) patients healed, 47 (58.7%) had minor amputation and 13 (16.2%) major amputation. Outcomes for SFP and FFP were respectively: healing (89.3 vs. 9.1%, p < 0.0001), minor amputation (44.7 vs. 78.8%, p = 0.0001), major amputation (2.1 vs. 36.3%, p < 0.0001). Failed foot revascularization resulted an independent predictor of non-healing, minor amputation, and major amputation. Foot revascularization is mandatory to achieve healing and avoid major amputation in persons with ischaemic DFU and BTA arterial disease.

2.
J Cardiovasc Med (Hagerstown) ; 20(5): 335-342, 2019 May.
Article in English | MEDLINE | ID: mdl-30925146

ABSTRACT

BACKGROUND: Stroke is the third most common cause of death and one of the most common cause of long-term disability in the Western world. Carotid plaque morphology is the main predictor of cerebrovascular accidents, more than the degree of stenosis. AIMS: The primary aim was to validate virtual histology- intravascular ultrasound (VH-IVUS) as a diagnostic tool for carotid plaque characterization, by comparison with histology, through ex-vivo evaluation of carotid plaques. The secondary target was to compare VH-IVUS with high-resolution MRI (HR-MRI) through in-vivo evaluation of carotid artery plaques. MATERIALS AND METHODS: In the ex-vivo study, data were acquired from six carotid arteries explanted from six symptomatic male patients with a mean age of 72 W 9.64 years. Sectional images obtained with the IVUS catheter were compared with digitalized histological images. Twelve consecutive patients (eight men, four women, mean age of 75 W 6.33 years), candidates for carotid artery stenting, were included in the in-vivo study. All histological and HR-MR images were converted to a digital format and the exact percentages of the four plaque components were determined. RESULTS: Forty-two images were used for correlation between VH-IVUS and histology. Quantitative analysis of different plaque components revealed a good concordance (0.82) between the two methods [95% confidence interval (CI) 0.69-0.92]. Precision rates of VH-IVUS for concordance with true histology of different plaque components were 99.4% for fibrous tissue, 85.9% for fibrolipid tissue, 71.4% for calcium and 83.4% for necrosis. Comparison between HR-MRI and VH-IVUS was performed on 27 images. Concordance between the two methods was 0.84 (95% CI 0.69-0.92). Precision rates were, respectively, 85.3, 95.2, 90.2 and 82.0%. CONCLUSION: We believe that VH-IVUS may be useful when a quick intraprocedural evaluation of a carotid plaque before or after stent placement is required, but is not suitable for the accurate in-vivo differentiation between stable and unstable plaques prone to rupture, due to the suboptimal assessment of the necrotic component, fibrous cap thickness and rupture signs. We do believe, however, that these results need further evaluation in larger populations to be confirmed.


Subject(s)
Carotid Arteries/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Magnetic Resonance Angiography , Plaque, Atherosclerotic , Ultrasonography, Interventional , Aged , Aged, 80 and over , Biopsy , Carotid Arteries/pathology , Carotid Arteries/surgery , Carotid Stenosis/pathology , Carotid Stenosis/surgery , Endovascular Procedures/instrumentation , Female , Fibrosis , Humans , Male , Middle Aged , Necrosis , Predictive Value of Tests , Prognosis , Reproducibility of Results , Rupture, Spontaneous , Severity of Illness Index , Stents
3.
J Cardiovasc Med (Hagerstown) ; 20(4): 248-252, 2019 04.
Article in English | MEDLINE | ID: mdl-23292649

ABSTRACT

AIMS: The primary aim is the evaluation of the usefulness of intravascular ultrasound (IVUS) in the identification of otherwise unnoticed complications during carotid stenting. The secondary aim is the evaluation of the impact of IVUS assistance in the procedural outcomes and long-term patency rates of carotid artery stenting. MATERIALS AND METHODS: Sixty patients who underwent carotid artery stenting (CAS) during a 14-month period were evaluated prospectively. Thirty patients (50%) underwent IVUS assisted CAS, 30 patients (50%) underwent CAS using angiography as the unique diagnostic tool. All patients were enrolled through a primary duplex ultrasound evaluation; as a secondary evaluation, 54 patients (90%) underwent a preprocedural magnetic resonance angiography, whereas six patients (10%) underwent computed tomography-angiography. Patients with preocclusive stenoses (>85%) were excluded. Mean follow-up was 23 W 5.3 months. RESULTS: No periprocedural or late complications were observed. No statistical significance was observed in long-term stent patency between the two groups. Mean procedural time length of IVUS-assisted procedures was 10.3 W 5 min longer than non-IVUS-assisted procedures. Virtual histology (VH) IVUS evaluation of plaque morphology led to a different stent choice in three patients. In two cases, the IVUS assessment revealed a suboptimal stent deployment, solved by angioplasty; in one patient VH-IVUS detected plaque protrusion through stent cells, immediately treated by manual aspiration. CONCLUSIONS: Though not recommended as a routine intraprocedural evaluation, IVUS may be useful for a real-time CAS control when treating challenging plaques, such as 'soft' or lipidic ones or those prone to rupture, or whenever an intraprocedural morphologic evaluation is required for the appropriate stent choice, or when higher embolic risk is evaluated.


Subject(s)
Carotid Arteries/surgery , Carotid Stenosis/surgery , Endovascular Procedures/instrumentation , Stents , Ultrasonography, Interventional , Vascular Patency , Aged , Aged, 80 and over , Carotid Arteries/diagnostic imaging , Carotid Arteries/physiopathology , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/physiopathology , Clinical Decision-Making , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Female , Humans , Male , Predictive Value of Tests , Preliminary Data , Prospective Studies , Prosthesis Design , Rome , Severity of Illness Index , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex
5.
J Vasc Interv Radiol ; 28(4): 543-549, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28258802

ABSTRACT

PURPOSE: To evaluate outcomes and prognostic factors in patients with acute ischemic stroke caused by tandem internal carotid artery/middle cerebral artery occlusion undergoing endovascular treatment. MATERIALS AND METHODS: Characteristics of consecutive patients with tandem occlusion (TO) were extracted from a prospective registry. Collateral vessel quality on pretreatment computed tomographic (CT) angiography was evaluated on a 4-point grading scale, and patients were dichotomized as having poor or good collateral flow. Outcome measures included successful reperfusion according to Thrombolysis In Cerebral Infarction score, good outcome at 3 months defined as a modified Rankin scale score ≤ 2, symptomatic intracranial hemorrhage (ICH; sICH), and mortality. RESULTS: A total of 72 patients with TO (mean age, 65.6 y ± 12.8) were treated. Intravenous thrombolysis was performed in 54.1% of patients, and a carotid stent was inserted in 48.6%. Successful reperfusion was achieved in 64% of patients, and a good outcome was achieved in 32%. sICH occurred in 12.5% of patients, and the overall mortality rate was 32%. Univariate analysis demonstrated that good outcome was associated with good collateral flow (P = .0001), successful reperfusion (P = .001), and lower rate of any ICH (P = .02) and sICH (P = .04). On multivariate analysis, good collateral flow (odds ratio [OR], 0.18; 95% confidence interval [CI], 0.04-0.75; P = .01) and age (OR, 1.08; 95% CI, 1.01-1.15; P = .01) were the only predictors of good outcome. The use of more than one device for thrombectomy was the only predictor of sICH (OR, 10.74; 95% CI, 1.37-84.13; P = .02). CONCLUSIONS: Endovascular treatment for TO resulted in good outcomes. Collateral flow and age were independent predictors of good clinical outcomes at 3 months.


Subject(s)
Carotid Artery, Internal , Carotid Stenosis/therapy , Endovascular Procedures , Infarction, Middle Cerebral Artery/therapy , Aged , Aged, 80 and over , Carotid Artery, Internal/diagnostic imaging , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/mortality , Cerebrovascular Circulation , Collateral Circulation , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Infarction, Middle Cerebral Artery/complications , Infarction, Middle Cerebral Artery/diagnostic imaging , Infarction, Middle Cerebral Artery/mortality , Intracranial Hemorrhages/etiology , Logistic Models , Male , Middle Aged , Multivariate Analysis , Odds Ratio , Recovery of Function , Regional Blood Flow , Registries , Risk Factors , Rome , Stents , Thrombectomy , Thrombolytic Therapy , Time Factors , Treatment Outcome
6.
Int J Cardiol ; 240: 92-96, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28318657

ABSTRACT

BACKGROUND: Interventional radiology and cardiology procedures contribute significantly to the collective dose of radiation exposure from medical interventions. Recent and dedicated studies comparing directly these procedures in term of patient radiation exposure are lacking. Our aim was to compare radiation exposure among different interventional procedures performed under fluoroscopic guidance. METHODS: The RODEO study (NCT: 02972736) is an international observational retrospective multicenter study enrolling all patients undergoing diagnostic or interventional procedures performed by different interventional operators (i.e. radiologists, interventional cardiologists or electrophysiologists) in 6 centers, without exclusion criteria. The primary end-point of the study was the comparison of dose area product (DAP) among interventional cardiology, electrophysiology or interventional radiology procedures. RESULTS: A total of 17,711 procedures were included in the study: 13,522 interventional cardiology, 2352 electrophysiology and 1864 interventional radiology procedures. The highest DAP values were observed for interventional radiology procedures (74Gy∗cm2 [Interquartile range 27-178Gy∗cm2]), followed by interventional cardiology (40Gy∗cm2 [22-78Gy∗cm2]) and electrophysiology procedures (13Gy∗cm2 [4-44Gy∗cm2], p<0.0001). In term of specific procedures, the highest DAP values were observed in structural or valvular cardiac procedures (134Gy∗cm2 [51-260Gy∗cm2]) whereas the lowest DAP values in pacemaker insertion (11Gy∗cm2 [4-28Gy∗cm2]). CONCLUSION: In this large multicenter study, the highest radiation exposure was observed in procedures performed by interventional radiologists. However, among specific procedures, structural or valvular cardiac procedures were associated with the highest radiation exposure.


Subject(s)
Endovascular Procedures/adverse effects , Occupational Exposure/prevention & control , Radiation Dosage , Radiation Exposure/prevention & control , Radiation Monitoring/methods , Radiologists , Aged , Aged, 80 and over , Endovascular Procedures/standards , Female , Humans , Internationality , Male , Middle Aged , Occupational Exposure/standards , Radiation Exposure/standards , Radiation Monitoring/standards , Radiologists/standards , Retrospective Studies
7.
Med Oncol ; 34(3): 37, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28160267

ABSTRACT

To evaluate safety, efficacy of drug-eluting beads with irinotecan (DEBIRI) on local response and survival of patients affected by colorectal liver metastases (CRLM) progressing during or after second line was evaluated. Sixty-two patients, with colorectal liver metastases, not suitable for surgery or thermal ablation treatments, progressing during or within 6 month from the end of second-line chemotherapy, were treated with DEBIRI chemoembolization between February 2009 and July 2014. CRLM were histologically confirmed. Exclusion criteria were considered. The DEBIRI technique consists in intrahepatic embolization of metastases with non-absorbable beads (75-150 µm and 100-300 µm) preloaded with irinotecan, carried near tumour using a selective catheterization of the right or of the left hepatic artery. To control pain associated with treatment, we use a specific schedule. Efficacy of treatment, defined as lack of disease progression and reduction in size of metastasis according to RECIST 1.1 criteria, was evaluated after two treatments with contrast-enhanced computed tomography (CT) at 4 months. If necessary, more treatments are repeated. A total of 191 procedures were performed. No intra-/peri-procedural death occurred. Pain and post-embolization syndrome were generally controlled by medications. Overall, the efficacy of treatment, evaluated in terms of stability and remission of the disease, was 37.1%. In our experience, DEBIRI technique results as a safe and effective procedure, with good intra- and peri-procedural tolerability.


Subject(s)
Camptothecin/analogs & derivatives , Chemoembolization, Therapeutic/methods , Colorectal Neoplasms/therapy , Liver Neoplasms/surgery , Liver Neoplasms/therapy , Aged , Antineoplastic Agents, Phytogenic/administration & dosage , Antineoplastic Combined Chemotherapy Protocols/administration & dosage , Camptothecin/administration & dosage , Colorectal Neoplasms/drug therapy , Colorectal Neoplasms/pathology , Female , Fluorouracil/administration & dosage , Humans , Irinotecan , Leucovorin/administration & dosage , Liver Neoplasms/drug therapy , Male , Middle Aged , Organoplatinum Compounds/administration & dosage , Retrospective Studies
8.
Phlebology ; 32(5): 355-359, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27231139

ABSTRACT

Objectives Venous aneurysms are uncommon. They can involve both superficial and deep venous systems. We hereby present a unique case of gastrocnemius venous aneurysm developed after compressive knee trauma. Report A large venous aneurysm in the left popliteal fossa was detected by chance in a 44-year-old woman one month after a compressive trauma to the posterior surface of the knee. Magnetic resonance-imaging of the same knee had documented normal venous anatomy one year earlier. The venous aneurysm involved the medial gastrocnemius vein near its confluence in the popliteal vein and was surgically resected. Histopathology evidenced a true venous aneurysm. The patient was discharged under oral anticoagulation for three months. At one year follow-up, neither complications nor new venous aneurysm development was detected. Conclusions An accurate evaluation of the venous system is always mandatory after limb traumas which may lead to post-traumatic venous pseudo-aneurysms, as well as more rarely, true venous aneurysms in the lower extremities.


Subject(s)
Aneurysm , Anticoagulants/administration & dosage , Knee Injuries , Magnetic Resonance Imaging , Veins/surgery , Administration, Oral , Adult , Aneurysm/diagnostic imaging , Aneurysm/surgery , Humans , Knee Injuries/diagnostic imaging , Knee Injuries/surgery , Male
9.
Radiol Case Rep ; 11(3): 255-9, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27594962

ABSTRACT

Penile metastasis from prostate cancer represents a rare condition, associated with poor prognosis. In the literature, authors have reported less than 500 cases of secondary penile cancers, and among these cases of metastases, only 33% are from prostate cancer. Overall reported rate of survival is about 1-24 months. Here, we present an uncommon case of penile metastasis from prostatic adenocarcinoma, with particular focus on the role of computed tomography and magnetic resonance imaging in diagnosis and follow-up.

10.
Vasc Endovascular Surg ; 50(2): 72-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26983664

ABSTRACT

INTRODUCTION: The aim of this study was to assess whether individual patients' or bypass characteristics may influence long-term results of prosthetic above-knee femoropopliteal bypasses in patients with claudication in today's endovascular era. METHODS: Seventy-one consecutivee Expanded Polytetrafluoroethylene (e-PTFE) bypasses were considered. All patients presented a debilitating claudication. Patency of grafts was achieved by Kaplan-Meier method. The association between individual patients' or graft characteristics and primary patency (PP) or secondary patency (SP) was assessed via Cox regression models. RESULTS: An immediate technical success was achieved in all cases. No patient was lost during follow-up (8-90 months, median = 34 months). The median PP was 48 months. Occlusion occurred in 32 bypasses (45%). Eight (25%) of these were treated conservatively. Fifty-two bypasses (73%) were still patent at the end of follow-up, and 13 (25%) of these had been submitted to one or more surgical revisions. There were 2 graft infections. Of 17 (25%) patients with occluded graft at the end of follow-up, 2 (2.8%) had significant aggravation followed by limb loss. The PP was directly influenced by undetected minor distal anastomosis technical defects (hazard ratio [HR] = 5.89, P value = .000002), popliteal artery size (HR = 0.62, P value = 0.007), and distal anastomosis angle ≥40° (HR = 5.55, P value = .003). The SP was associated strictly to technical defects (HR = 11.08, P value = .000007). Multivariable analyses confirmed the influence of technical defects (HR = 6.42, P value = .000003) and anastomosis angle (HR = 1.05, P value = .009) on PP and that of technical defects on SP (HR = 10.84, P value = .00003). A significantly shorter SP was also observed after a previous failed endovascular treatment on the superficial femoral artery (HR = 3.73, P value = .02). CONCLUSION: An adequate arterial size, an ideal anastomotic angle, and the absence of minor, technical defects have a major role in prosthetic above-knee femoropopliteal bypass long-term outcome. A previous, failed endovascular procedure on the superficial femoral artery could markedly alter the natural history of patients with claudication because this approach seems to have a detrimental effect on long-term outcome of grafts needing surgical revisions.


Subject(s)
Blood Vessel Prosthesis Implantation , Femoral Artery/surgery , Intermittent Claudication/surgery , Peripheral Arterial Disease/surgery , Popliteal Artery/surgery , Aged , Amputation, Surgical , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/surgery , Humans , Intermittent Claudication/diagnostic imaging , Intermittent Claudication/physiopathology , Ischemia/diagnostic imaging , Ischemia/physiopathology , Ischemia/surgery , Italy , Kaplan-Meier Estimate , Limb Salvage , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Polytetrafluoroethylene/adverse effects , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Proportional Hazards Models , Prosthesis Design , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/surgery , Reoperation , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
12.
J Cardiovasc Surg (Torino) ; 57(5): 625-33, 2016 Oct.
Article in English | MEDLINE | ID: mdl-25475915

ABSTRACT

BACKGROUND: The aim of this study was to assess the technical success and clinical long-term results of renal artery aneurysm (RAA) treatment using covered stents. METHODS: We performed a retrospective study on endovascular treatment of nine patients with 10 RAAs, arising from the main renal artery or from the proximal portion of large segmental arteries. All procedures were performed in our department between 2004 and 2011. The aneurysms were excluded using covered stents. Our follow-up included laboratories indexes, Computed Tomography-angiography (CTA) at 1-6-12-24 months and 48-month Duplex-ultrasound examination. RESULTS: Study population included 4 males and 5 females (mean age: 63.5±7.3 y.o.). Six were affected by fibromuscular dysplasia and associated renal artery stenosis. The population showed a significant decrease of arterial blood pressure (from baseline values of 163.9±19.4/98.9±9.2 mmHg to 128.9±6.5/79.4±4.6 mmHg at 24 months follow-up) and of drug posology (baseline 3.7±0.7 drugs to 1.6±0.7 drugs at 24 months). Also they showed a significant decrease of serum creatinine levels (baseline 1.9±1.4 mg/dL vs.1.1±0.4 mg/dL at 12 months) and increase of glomerular filtration rate (from baseline values 46.9±23 mL/min/1.73 m2 to 69.1±20 mL/min/1.73 m2 at 24 months follow-up). CTA demonstrated patency of the cover stents, absence of endoleaks and re-stenosis in all patients. Only in one patient the inferior segmental artery was sacrificed due to the presence of its early origin, resulting in a small area of renal parenchyma infarction with no significant clinical consequences. CONCLUSIONS: The procedure revealed to be safe for renal function, feasible and effective for the exclusion of the aneurismal sac and restoring vessel patency.


Subject(s)
Aneurysm/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Renal Artery/surgery , Stents , Aged , Aneurysm/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Female , Humans , Male , Middle Aged , Prosthesis Design , Renal Artery/diagnostic imaging , Retrospective Studies , Rome , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex
13.
J Endovasc Ther ; 21(5): 714-22, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25290801

ABSTRACT

PURPOSE: To assess the technical and midterm results in the treatment of type II endoleaks comparing nonselective (nTCE) vs. selective (sTCE) transcaval embolization. METHODS: During a 4-year period, 26 patients (18 men; median age 73 years, range 68-78) underwent direct transcaval aneurysm puncture followed by embolization of the sac (nTCE, n=9) or of the feeding vessels (sTCE, n=17). Intrasac pressure was recorded immediately after aneurysm sac puncture and at the end of the procedure. Technical success was defined as successful deployment of embolization material in the sac or in the feeding vessel. Clinical success was defined as absence of endoleak with stabilization of the sac on follow-up CTA. RESULTS: Technical success was 100% in the 9 patients treated with nTCE. Mean intrasac pressures before and after nTCE were 58.6±18.4 (range 51-105) and 6.5±1.2 mmHg (range 4-9), respectively. Over a mean 25.9±11.0 months of follow-up, 4 patients developed recurrent endoleak at a mean 9.7±3.9 months. Three patients were subsequently treated with sTCE, while the last patient underwent emergency surgery for aneurysm rupture due to an enlarging sac 5 months after nTCE. The 20 patients in the sTCE group had a successful procedure with no recurrence in a follow-up of 24.1±7.2 months. Mean intrasac pressure was reduced after sTCE from 63.6±15.2 mmHg (range 43-120) to 7.8±2.3 mmHg (range 5-12). CONCLUSION: The selective TCE approach appears to be a feasible and effective primary therapeutic option for treating type II endoleak.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Embolization, Therapeutic/methods , Endoleak/therapy , Endovascular Procedures/adverse effects , Vena Cava, Inferior , Aged , Aortic Aneurysm, Abdominal/diagnosis , Aortography/methods , Embolization, Therapeutic/adverse effects , Endoleak/diagnosis , Endoleak/etiology , Feasibility Studies , Female , Humans , Male , Middle Aged , Punctures , Recurrence , Retrospective Studies , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Vena Cava, Inferior/diagnostic imaging
15.
Clin Neurol Neurosurg ; 115(6): 741-7, 2013 Jun.
Article in English | MEDLINE | ID: mdl-22989778

ABSTRACT

BACKGROUND: Intracranial atherosclerosis may be the underlying pathology in up to 15% of ischemic strokes, but may account for about 40% of strokes in some populations. After an ischemic event determined by intracranial atherosclerosis, patients have a 12% annual risk of stroke recurrence, mostly during the first year. OBJECTIVE: To evaluate procedural safety, clinical outcome and restenosis rate of Wingspan stent placement. METHODS: Twenty-one caucasoid patients were enrolled. Target patients were affected by high-grade, symptomatic, intracranial atherosclerotic lesions, were on antithrombotic therapy and at high stroke risk. All patients were treated with the Wingspan stent system. RESULTS: Technical success resulted 100%, with all target lesions being reduced to <50%. No stroke or death were observed at 30. The mean percent of stenosis was reduced from a middle value of 84% to a middle value of 17% after stent placement. Medium follow-up was 19.5months (range 6-36months). No stroke or death occurred in any patient. None of the patients presented a <50% stent patency rate at follow-up. CONCLUSIONS: The short-term results and follow up analysis provide evidence demonstrating the safety of the Wingspan system when used in high-risk patient population. Due to concerns regarding long-term stent patency and ischemic events occurrence emerged from clinical trials such as the SAMMPRIS, intracranial angioplasty and stent with the Wingspan system should be considered only for high risk patients in which it may be considered the only viable therapeutic option.


Subject(s)
Graft Occlusion, Vascular/epidemiology , Plaque, Atherosclerotic/surgery , Stents , Stroke/prevention & control , Aged , Aged, 80 and over , Alloys , Angioplasty , Brain Ischemia/complications , Brain Ischemia/surgery , Cerebral Angiography , Constriction, Pathologic/prevention & control , Endpoint Determination , Female , Fibrinolytic Agents/therapeutic use , Follow-Up Studies , Humans , Magnetic Resonance Angiography , Male , Middle Aged , Plaque, Atherosclerotic/etiology , Platelet Aggregation Inhibitors/therapeutic use , Recurrence , Stents/adverse effects , Stroke/epidemiology , Survival Rate , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...