Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 32(8): 13628-13639, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38859328

ABSTRACT

A mid-infrared (mid-IR) porous silicon (PSi) waveguide gas sensor was fabricated. PSi guiding and confinement layers were prepared by electrochemical anodization. Ridge waveguides were patterned using standard i-line photolithography and reactive ion etching. Due to the open pores, light and gas molecules interact in the inside volume, unlike bulk material in which the interaction takes place with the evanescent part of the light. Propagation losses are measured for a wavelength range spanning from λ = 3.9 to 4.55 µm with a value of 11.4 dB/cm at λ = 4.28 µm. The influence of native oxidation and ageing on the propagation losses was investigated. Limit of detection (LoD) of 1000 ppm is obtained with the waveguide sensor at the carbon dioxide (CO2) absorption peak at λ = 4.28 µm.

2.
RSC Adv ; 14(17): 12071-12080, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38628480

ABSTRACT

The SARS-CoV-2 (COVID-19) pandemic had a strong impact on societies and economies worldwide and tests for high-performance detection of SARS-CoV-2 biomarkers are still needed for potential future outbreaks of the disease. In this paper, we present the different steps for the design of an aptamer-based surface-enhanced Raman scattering (BioSERS) sensing chip capable of detecting the coronavirus nucleocapsid protein (N protein) in spiked phosphate-buffered solutions and real samples of human blood serum. Optimization of the preparation steps in terms of the aptamer concentration used for the functionalization of the silver nanoparticles, time for affixing the aptamer, incubation time with target protein, and insulation of the silver active surface with cysteamine, led to a sensitive BioSERS chip, which was able to detect the N protein in the range from 1 to 75 ng mL-1 in spiked phosphate-buffered solutions with a detection limit of 1 ng mL-1 within 30 min. Furthermore, the BioSERS chip was used to detect the target protein in scarcely spiked human serum. This study demonstrates the possibility of a clinical application that can improve the detection limit and accuracy of the currently commercialized SARS-CoV-2 immunodiagnostic kit. Additionally, the system is modular and can be applied to detect other proteins by only changing the aptamer.

3.
Opt Lett ; 48(5): 1128-1131, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36857230

ABSTRACT

Climate-active gases, notably carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O), display fundamental absorption bands in the mid-infrared (mid-IR). The detection and monitoring of those gases could be enabled by the development of mid-IR optical sources. Broadband mid-IR on-chip light emission from rare-earth-doped chalcogenide photonic integrated circuits could provide a compact, efficient, and cost-effective gas sensing solution. Mid-IR photoluminescence of dysprosium-doped selenide ridge waveguides obtained under optical pumping at a telecommunication wavelength (∼1.3 µm) is investigated for Dy3+ ion concentrations in the 2500-10,000 ppmw range. CO2 detection at around 4.3 µm is then demonstrated based on absorption of this broadband mid-IR emission.

4.
Sensors (Basel) ; 22(3)2022 Jan 22.
Article in English | MEDLINE | ID: mdl-35161590

ABSTRACT

Porous germanium is a promising material for sensing applications in the mid-infrared wavelength range due to its biocompatibility, large internal surface area, open pores network and widely tunable refractive index, as well as its large spectral transparency window ranging from 2 to 15 µm. Multilayers, such as Bragg reflectors and microcavities, based on porous germanium material, are designed and their optical spectra are simulated to enable SF6 gas-sensing applications at a wavelength of 10.55 µm, which corresponds to its major absorption line. The impact of both the number of successive layers and their respective porosity on the multilayer structures reflectance spectrum is investigated while favoring low layer thicknesses and thus the ease of multilayers manufacturing. The suitability of these microcavities for mid-infrared SF6 gas sensing is then numerically assessed. Using an asymmetrical microcavity porous structure, a sensitivity of 0.01%/ppm and a limit of detection (LOD) around 1 ppb for the SF6 gas detection are calculated. Thanks to both the porous nature allowing gases to easily infiltrate the overall structure and Ge mid-infrared optical properties, a theoretical detection limit nearly 1000 times lower than the current state of the art is simulated.

5.
Appl Spectrosc ; 74(2): 168-177, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31617371

ABSTRACT

In this work, we combined a hierarchical nano-array effect of silicon nanowires (SiNWs) with a metallic surface of silver nanoparticles (AgNPs) to design a surface-enhanced Raman spectroscopy (SERS) scattering substrate for sensitive detection of Rhodamine 6G (R6G) which is a typical dye for fluorescence probes. The SiNWs were prepared by Metal-Assisted Chemical Etching (MACE) of n-Si (100) wafers. The Doehlert design methodology was used for planning the experiment and analyzing the experimental results. Thanks to this methodology, the R6G SERS response has been optimized by studying the effects of the silver nitrate concentration, silver nitrate and R6G immersion times and their interactions. The immersion time in R6G solution stands out as the most of influential factor on the SERS response.

6.
Opt Express ; 25(24): 30799-30806, 2017 Nov 27.
Article in English | MEDLINE | ID: mdl-29221106

ABSTRACT

We demonstrate the fabrication of a Vernier effect SU8/PMATRIFE polymer optical biosensor with high homogeneous sensitivity using a standard photolithography process. The sensor is based on one micro-resonator embedded on each arm of a Mach-Zehnder interferometer. Measurements are based on the refractive index variation of the optical waveguide superstrate with different concentrations of glucose solutions. The sensitivity of the sensor has been measured as 17558 nm/RIU and the limit of detection has been estimated to 1.1.10-6 RIU.

7.
Adv Mater ; 27(40): 6181-6, 2015 Oct 28.
Article in English | MEDLINE | ID: mdl-26350035

ABSTRACT

Thin films and ridge waveguides based on large-diameter semiconducting single-wall carbon nanotubes (s-SWCNTs) dispersed in a polyfluorene derivative are fabricated and optically characterized. Ridge waveguides are designed with appropriate dimensions for single-mode propagation at 1550 nm. Using multimode ridge waveguides, guided s-SWCNT photoluminescence is demonstrated for the first time in the near-infrared telecommunications window.

SELECTION OF CITATIONS
SEARCH DETAIL
...