1.
Brachytherapy ; 16(6): 1257-1264, 2017.
Article in English | MEDLINE | ID: mdl-28827006

ABSTRACT

PURPOSE: To present the clinical commissioning of a novel 103Pd directional brachytherapy device (CivaSheet) for intraoperative radiation therapy. METHODS AND MATERIALS: Clinical commissioning for the CivaSheet consisted of establishing: (1) source strength calibration capabilities, (2) experimental verification of TG-43 dosimetry parameters, (3) treatment planning system validation, and (4) departmental practice for dose specification and source ordering. Experimental verification was performed in water with radiochromic film calibrated with a 37 kVp X-ray beam. Percentage difference ([measurements - calculation]/calculation) and distance to agreement (difference between film-to-source distance and distance that minimized the percentage difference) were calculated. Nomogram values (in U/100 Gy) for all configurations (up to 20 × 20 sources) were calculated for source ordering. Clinical commissioning was used on patients enrolled in an ongoing Institutional Review Board-approved protocol. RESULTS: A source calibration procedure was established, and the treatment planning system was commissioned within standard clinical uncertainties. Percentage dose differences (distances to agreement) between measured and calculated doses were 8.6% (-0.12 mm), 0.6% (-0.01 mm), -6.4% (0.22 mm), and -10.0% (0.44 mm) at depths of 2.3, 5.1, 8.0, and 11.1 mm, respectively. All differences were within the experimental uncertainties. Nomogram values depended on sheet size and spatial extent. A value of 2.4U/100 Gy per CivaDot was found to satisfy most cases, ranging from 2.3 to 3.3U/100 Gy. Nomogram results depended on elongation of the treatment area with a higher variation observed for smaller treatment areas. Postimplantation dose evaluation was feasible. CONCLUSIONS: Commissioning and clinical deployment of CivaSheet was feasible using BrachyVision for postoperative dose evaluation. Experimental verification confirmed that the available TG-43 dosimetry parameters are accurate for clinical use.


Subject(s)
Brachytherapy/instrumentation , Intraoperative Care , Palladium , Prostheses and Implants , Brachytherapy/methods , Calibration , Film Dosimetry , Humans , Radiometry/instrumentation , Radiotherapy Dosage
2.
Med Phys ; 36(11): 5359-73, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19994544

ABSTRACT

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit = /mean/ + 1.96sigma. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.


Subject(s)
Radiometry , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/standards , Film Dosimetry , Head and Neck Neoplasms/radiotherapy , Humans , Male , Phantoms, Imaging , Prostatic Neoplasms/radiotherapy , Quality Assurance, Health Care
3.
Med Phys ; 34(6): 2228-58, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17654924

ABSTRACT

TG-69 is a task group report of the AAPM on the use of radiographic film for dosimetry. Radiographic films have been used for radiation dosimetry since the discovery of x-rays and have become an integral part of dose verification for both routine quality assurance and for complex treatments such as soft wedges (dynamic and virtual), intensity modulated radiation therapy (IMRT), image guided radiation therapy (IGRT), and small field dosimetry like stereotactic radiosurgery. Film is convenient to use, spatially accurate, and provides a permanent record of the integrated two dimensional dose distributions. However, there are several challenges to obtaining high quality dosimetric results with film, namely, the dependence of optical density on photon energy, field size, depth, film batch sensitivity differences, film orientation, processing conditions, and scanner performance. Prior to the clinical implementation of a film dosimetry program, the film, processor, and scanner need to be tested to characterize them with respect to these variables. Also, the physicist must understand the basic characteristics of all components of film dosimetry systems. The primary mission of this task group report is to provide guidelines for film selection, irradiation, processing, scanning, and interpretation to allow the physicist to accurately and precisely measure dose with film. Additionally, we present the basic principles and characteristics of film, processors, and scanners. Procedural recommendations are made for each of the steps required for film dosimetry and guidance is given regarding expected levels of accuracy. Finally, some clinical applications of film dosimetry are discussed.


Subject(s)
Advisory Committees , Film Dosimetry/instrumentation , Film Dosimetry/standards , Radiotherapy, High-Energy/instrumentation , Radiotherapy, High-Energy/standards , Societies, Scientific , Practice Guidelines as Topic
4.
Int J Radiat Oncol Biol Phys ; 66(1): 305-10, 2006 Sep 01.
Article in English | MEDLINE | ID: mdl-16904530

ABSTRACT

PURPOSE: Postmastectomy radiation therapy (PMRT) is often delivered to patients with permanent breast implants. On occasion, patients are irradiated with a tissue expander (TE) in place before their permanent implant exchange. Because of concern of potential under-dosing in these patients, we examined the dosimetric effects of the Magna-Site (Santa Barbara, CA) metallic port that is present in certain TEs. METHODS AND MATERIALS: We performed ex vivo film dosimetry with single 6-MV and 15-MV photon beams on a water phantom containing a Magna-Site disc in two orientations. Additionally, using in vivo films, we measured the exit dose from 1 patient's TE-reconstructed breast during chest wall treatment with 15-MV tangent beams. Finally, we placed thermoluminescent dosimeters (TLDs) on 6 patients with TEs who received PMRT delivered with 15-MV tangent beams. RESULTS: Phantom film dosimetry revealed decreased transmission in the region of the Magna-Site, particularly with the magnet in the parallel orientation (at 22 mm: 78% transmission with 6 MV, 84% transmission with 15 MV). The transmission measured by in vivo films during single beam treatment concurred with ex vivo results. TLD data showed acceptable variation in median dose to the skin (86-101% prescription dose). CONCLUSION: Because of potential dosimetric effects of the Magna-Site, it is preferable to treat PMRT patients with permanent implants. However, it is not unreasonable to treat with a TE because the volume of tissue affected by attenuation from the Magna-Site is small. In this scenario, we recommend using 15 MV photons with compensating bolus.


Subject(s)
Breast Neoplasms/radiotherapy , Metals , Tissue Expansion Devices , Adult , Breast Neoplasms/surgery , Female , Film Dosimetry/methods , Humans , Mastectomy , Middle Aged , Phantoms, Imaging , Postoperative Period , Radiotherapy Dosage , Thermoluminescent Dosimetry/methods