Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Emerg Med ; 64(3): 385-387, 2023 03.
Article in English | MEDLINE | ID: mdl-36932004

ABSTRACT

BACKGROUND: Rhino-orbital cerebral mucormycosis (ROCM) is a rare infection caused by an invasive fungus and found predominantly in immunocompromised patients. The presentation of ROCM ranges from a mild headache, fever, and sinusitis to vision loss, altered mental status, and facial disfigurement secondary to local tissue invasion. ROCM can cause significant morbidity and mortality and requires prompt diagnosis with timely evaluation by surgical and infectious disease specialists. Cases of ROCM have been reported extensively in internal medicine, infectious disease, and otolaryngology literature. However, there are very few reports in emergency medicine literature in the United States. CASE REPORT: A 72-year-old woman presented to the Emergency Department (ED) with altered mental status, 4 days of left-sided facial numbness and weakness, and sudden facial pain, swelling, and erythema. Laboratory analysis was consistent with diabetic ketoacidosis. Noncontrast computed tomography of the head and magnetic resonance imaging of the brain demonstrated findings indicative of invasive fungal infection of the left sinus and orbit with extension to the cavernous sinus and surrounding cranial nerves. She was initiated on broad-spectrum antifungals, but based on the extent of the infection, was not a surgical candidate. She subsequently transitioned to a comfort-based plan of care and died 6 days after initial ED presentation. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Early recognition and initiation of treatment can potentially mitigate the devastating outcomes of ROCM, therefore it is critical to be aware of this condition and have a high level of suspicion in susceptible patients.


Subject(s)
Diabetes Mellitus , Diabetic Ketoacidosis , Eye Diseases , Mucormycosis , Orbital Diseases , Female , Humans , Aged , Mucormycosis/complications , Mucormycosis/diagnosis , Mucormycosis/microbiology , Antifungal Agents/therapeutic use , Diabetic Ketoacidosis/complications , Diabetes Mellitus/drug therapy
2.
Resusc Plus ; 13: 100347, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36654723

ABSTRACT

Interventions for many medical emergencies including cardiac arrests, strokes, drug overdoses, seizures, and trauma, are critically time-dependent, with faster intervention leading to improved patient outcomes. Consequently, a major focus of emergency medical services (EMS) systems and prehospital medicine has been improving the time until medical intervention in these time-sensitive emergencies, often by reducing the time required to deliver critical medical supplies to the scene of the emergency. Medical indications for using unmanned aerial vehicles, or drones, are rapidly expanding, including the delivery of time-sensitive medical supplies. To date, the drone-based delivery of a variety of time-critical medical supplies has been evaluated, generating promising data suggesting that drones can improve the time interval to intervention through the rapid delivery of automatic external defibrillators (AEDs), naloxone, antiepileptics, and blood products. Furthermore, the improvement in the time until intervention offered by drones in out-of-hospital emergencies is likely to improve patient outcomes in time-dependent medical emergencies. However, barriers and knowledge gaps remain that must be addressed. Further research demonstrating functionality in real-world scenarios, as well as research that integrates drones into the existing EMS structure will be necessary before drones can reach their full potential. The primary aim of this review is to summarize the current evidence in drone-based Emergency Medical Services Care to help identify future research directions.

3.
Prehosp Disaster Med ; 37(3): 383-389, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35379372

ABSTRACT

BACKGROUND/OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic has challenged the ability of Emergency Medical Services (EMS) providers to maintain personal safety during the treatment and transport of patients potentially infected. Increased rates of COVID-19 infection in EMS providers after patient care exposure, and notably after performing aerosol-generating procedures (AGPs), have been reported. With an already strained workforce seeing rising call volumes and increased risk for AGP-requiring patient presentations, development of novel devices for the protection of EMS providers is of great importance.Based on the concept of a negative pressure room, the AerosolVE BioDome is designed to encapsulate the patient and contain aerosolized infectious particles produced during AGPs, making the cabin of an EMS vehicle safer for providers. The objective of this study was to determine the efficacy and safety of the tent in mitigating simulated infectious particle spread in varied EMS transport platforms during AGP utilization. METHODS: Fifteen healthy volunteers were enrolled and distributed amongst three EMS vehicles: a ground ambulance, an aeromedical-configured helicopter, and an aeromedical-configured jet. Sodium chloride particles were used to simulate infectious particles and particle counts were obtained in numerous locations close to the tent and around the patient compartment. Counts near the tent were compared to ambient air with and without use of AGPs (non-rebreather mask, continuous positive airway pressure [CPAP] mask, and high-flow nasal cannula [HFNC]). RESULTS: For all transport platforms, with the tent fan off, the particle generator alone, and with all AGPs produced particle counts inside the tent significantly higher than ambient particle counts (P <.0001). With the tent fan powered on, particle counts near the tent, where EMS providers are expected to be located, showed no significant elevation compared to baseline ambient particle counts during the use of the particle generator alone or with use of any of the AGPs across all transport platforms. CONCLUSION: Development of devices to improve safety for EMS providers to allow for use of all available therapies to treat patients while reducing risk of communicable respiratory disease transmission is of paramount importance. The AerosolVE BioDome demonstrated efficacy in creating a negative pressure environment and workspace around the patient and provided significant filtration of simulated respiratory droplets, thus making the confined space of transport vehicles potentially safer for EMS personnel.


Subject(s)
COVID-19 , Emergency Medical Services , Aerosolized Particles and Droplets , Aerosols , Humans , Pandemics/prevention & control , SARS-CoV-2
4.
Prehosp Disaster Med ; 37(1): 33-38, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35094732

ABSTRACT

BACKGROUND/OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic has created challenges in maintaining the safety of prehospital providers caring for patients. Reports have shown increased rates of Emergency Medical Services (EMS) provider infection with COVID-19 after patient care exposure, especially while utilizing aerosol-generating procedures (AGPs). Given the increased risk and rising call volumes for AGP-necessitating complaints, development of novel devices for the protection of EMS clinicians is of great importance.Drawn from the concept of the powered air purifying respirator (PAPR), the AerosolVE helmet creates a personal negative pressure space to contain aerosolized infectious particles produced by patients, making the cabin of an EMS vehicle safer for providers. The helmet was developed initially for use in hospitals and could be of significant use in the prehospital setting. The objective of this study was to determine the efficacy and safety of the helmet in mitigating simulated infectious particle spread in varied EMS transport platforms during AGP utilization. METHODS: Fifteen healthy volunteers were enrolled and distributed amongst three EMS vehicles: a ground ambulance, a medical helicopter, and a medical jet. Sodium chloride particles were used to simulate infectious particles, and particle counts were obtained in numerous locations close to the helmet and around the patient compartment. Counts near the helmet were compared to ambient air with and without use of AGPs (non-rebreather mask [NRB], continuous positive airway pressure mask [CPAP], and high-flow nasal cannula [HFNC]). RESULTS: Without the helmet fan on, the particle generator alone and with all AGPs produced particle counts inside the helmet significantly higher than ambient particle counts. With the fan on, there was no significant difference in particle counts around the helmet compared to baseline ambient particle counts. Particle counts at the filter exit averaged less than one despite markedly higher particle counts inside the helmet. CONCLUSION: Given the risk to EMS providers by communicable respiratory diseases, development of devices to improve safety while still enabling use of respiratory therapies is of paramount importance. The AerosolVE helmet demonstrated efficacy in creating a negative pressure environment and provided significant filtration of simulated respiratory droplets, thus making the confined space of transport vehicles potentially safer for EMS personnel.


Subject(s)
COVID-19 , Emergency Medical Services , Aerosolized Particles and Droplets , Head Protective Devices , Humans , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...