Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Condens Matter ; 30(49): 494002, 2018 Dec 12.
Article in English | MEDLINE | ID: mdl-30451158

ABSTRACT

We report a study of the structural phase transitions induced by pressure in bulk black phosphorus by using both synchrotron x-ray diffraction for pressures up to 12.2 GPa and Raman spectroscopy up to 18.2 GPa. Very recently black phosphorus attracted large attention because of the unique properties of few-layers samples (phosphorene), but some basic questions are still open in the case of the bulk system. As concerning the presence of a Raman spectrum above 10 GPa, which should not be observed in an elemental simple cubic system, we propose a new explanation by attributing a key role to the non-hydrostatic conditions occurring in Raman experiments. Finally, a combined analysis of Raman and XRD data allowed us to obtain quantitative information on presence and extent of coexistences between different structural phases from ~5 up to ~15 GPa. This information can have an important role in theoretical studies on pressure-induced structural and electronic phase transitions in black phosphorus.

2.
Eur Respir J ; 27(4): 742-7, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16585080

ABSTRACT

This study hypothesises that regardless of the global score of dyspnoea intensity, different descriptors may be selected by asthmatic patients during short cardiopulmonary exercise test (sCPET) and methacholine (Mch) inhalation. It also examines whether different qualitative dyspnoea sensations can help explain the underlying mechanisms of the symptom. Minute ventilation (V'E), tidal volume (VT) and inspiratory capacity (IC) were measured in 22 stable asthmatic patients, and the sensation of dyspnoea during Mch inhalation and sCPET was quantitatively (Borg scale) and qualitatively (descriptors) assessed. The work rate and oxygen uptake (V'O2) were also measured during sCPET. Airway obstruction and hyperinflation, as measured by IC reduction, were the best correlates for dyspnoea with Mch. During sCPET, changes in WR, V'O2, V'E and VT significantly correlated with Borg score, with V'E being the best predictor of dyspnoea; IC decreased in eight patients. Furthermore, chest tightness (68%) was the highest reported descriptor during Mch inhalation, whereas work/effort (72%) was the highest during sCPET. In conclusion, obstruction/hyperinflation and work rate are highly reliable predictors of Borg rating of dyspnoea during methacholine inhalation and short cardiopulmonary exercise testing, respectively. Regardless of the global score of intensity dyspnoea, different descriptors may be selected by patients during short cardiopulmonary exercise testing and methacholine inhalation. Various qualities of dyspnoea result from different pathophysiological abnormalities.


Subject(s)
Asthma/psychology , Bronchial Provocation Tests/psychology , Dyspnea/psychology , Exercise Test/psychology , Methacholine Chloride , Sick Role , Administration, Inhalation , Adult , Aged , Airway Obstruction/diagnosis , Airway Obstruction/physiopathology , Airway Obstruction/psychology , Asthma/diagnosis , Asthma/physiopathology , Dyspnea/diagnosis , Dyspnea/physiopathology , Female , Humans , Lung Volume Measurements , Male , Middle Aged , Physical Exertion/physiology , Psychophysics , Spirometry
3.
Eur J Appl Physiol ; 95(2-3): 229-42, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16086145

ABSTRACT

To determine the effects of exercise with expiratory flow-limitation (EFL) on systemic O(2) delivery, seven normal subjects performed incremental exercise with and without EFL at approximately 0.8 l s(-1) (imposed by a Starling resistor in the expiratory line) to determine maximal power output under control (W'(max,c)) and EFL (W'(max,e)) conditions. W'(max,e) was 62.5% of W'(max,c), and EFL exercise caused a significant fall in the ventilatory threshold. In a third test, after exercising at W'(max,e) without EFL for 4 min, EFL was imposed; exercise continued for 4 more minutes or until exhaustion. O(2) consumption (V'(O)(2)) was measured breath-by-breath for the last 90 s of control, and for the first 90 s of EFL exercise. Assuming that the arterio-mixed venous O(2) content remained constant immediately after EFL imposition, we used V'(O)(2) as a measure of cardiac output (Q'(c)). Q'(c) was also calculated by the pulse contour method with blood pressure measured continuously by a photo-plethysmographic device. Both sets of data showed a decrease of Q'(c) due to a decrease in stroke volume by 10% (p < 0.001 for V'(O)(2)) with EFL and remained decreased for the full 90 s. Concurrently, arterial O(2) saturation decreased by 5%, abdominal, pleural and alveolar pressures increased, and duty cycle decreased by 43%. We conclude that this combination of events led to a decrease in venous return secondary to high expiratory pressures, and a decreased duty cycle which decreased O(2) delivery to working muscles by approximately 15%.


Subject(s)
Exercise/physiology , Oxygen Consumption/physiology , Pulmonary Ventilation/physiology , Adult , Blood Pressure/physiology , Cardiac Output/physiology , Exercise Test , Female , Humans , Lung/physiology , Lung Volume Measurements , Male , Pulmonary Gas Exchange/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...