Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 127
Filter
1.
Article in English | MEDLINE | ID: mdl-38465788

ABSTRACT

BACKGROUND: Chronic rhinosinusitis with nasal polyp (CRSwNP) is a typical type 2 inflammation involving interleukin (IL)-4 and IL-13. Dupilumab is a fully human monoclonal antibody targeting IL-4 receptor α subunit, thereby blocking signaling by both cytokines. Our hypothesis was that IL-4 and IL-13, by inducing a severe epithelial dysregulation, are involved in CRSwNP pathogenesis. This study aimed to evaluate the in vitro direct effect of IL-4, IL-13, and dupilumab on nasal epithelial functions. METHODS: Nasal polyps and control mucosa from 28 patients, as well as human nasal epithelial cells (HNEC) from 35 patients with CRSwNP were used. Three major epithelial functions were investigated: the epithelial barrier function (characterized by transepithelial electrical resistance measurements and tight junction protein expression), the ciliary motion (characterized by the ciliary beating efficiency index), and wound healing (characterized by the wound repair rate) under various stimulations (IL-4, IL-13, and dupilumab). The main outcome was a significant change in epithelial functions following exposure to IL-4, IL-13, and dupilumab for 48 h in the basal media. RESULTS: IL-4 (1, 10, and 100 ng/mL) but not IL-13 induced a significant decrease in occludin and zonula-occludens protein expression, ciliary beating efficiency, and wound repair rate in HNEC. Dupilumab (0.04 mg/mL) had no effect on HNEC and specifically restored all epithelial functions altered when cells were exposed to a 48-h IL-4 stimulation. CONCLUSION: Dupilumab, in vitro, restored epithelial integrity by counteracting the effect of IL-4 on the epithelial barrier (increased epithelial permeability, decreased ciliary beating efficiency, and decreased wound repair rate).

2.
J Med Genet ; 61(6): 595-604, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38408845

ABSTRACT

BACKGROUND: Primary ciliary dyskinesia (PCD) is a rare airway disorder caused by defective motile cilia. Only male patients have been reported with pathogenic mutations in X-linked DNAAF6, which result in the absence of ciliary dynein arms, whereas their heterozygous mothers are supposedly healthy. Our objective was to assess the possible clinical and ciliary consequences of X-chromosome inactivation (XCI) in these mothers. METHODS: XCI patterns of six mothers of male patients with DNAAF6-related PCD were determined by DNA-methylation studies and compared with their clinical phenotype (6/6 mothers), as well as their ciliary phenotype (4/6 mothers), as assessed by immunofluorescence and high-speed videomicroscopy analyses. The mutated X chromosome was tracked to assess the percentage of cells with a normal inactivated DNAAF6 allele. RESULTS: The mothers' phenotypes ranged from absence of symptoms to mild/moderate or severe airway phenotypes, closely reflecting their XCI pattern. Analyses of the symptomatic mothers' airway ciliated cells revealed the coexistence of normal cells and cells with immotile cilia lacking dynein arms, whose ratio closely mirrored their XCI pattern. CONCLUSION: This study highlights the importance of searching for heterozygous pathogenic DNAAF6 mutations in all female relatives of male PCD patients with a DNAAF6 defect, as well as in females consulting for mild chronic respiratory symptoms. Our results also demonstrate that about one-third-ranging from 20% to 50%-normal ciliated airway cells sufficed to avoid severe PCD, a result paving the way for gene therapy.


Subject(s)
Cilia , X Chromosome Inactivation , Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Cilia/pathology , Cilia/genetics , Ciliary Motility Disorders/genetics , Ciliary Motility Disorders/pathology , DNA Methylation/genetics , Dyneins/genetics , Kartagener Syndrome/genetics , Kartagener Syndrome/pathology , Mutation , Phenotype , X Chromosome Inactivation/genetics
3.
Proc Natl Acad Sci U S A ; 121(5): e2313089121, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38252817

ABSTRACT

In cystic fibrosis (CF), impaired mucociliary clearance leads to chronic infection and inflammation. However, cilia beating features in a CF altered environment, consisting of dehydrated airway surface liquid layer and abnormal mucus, have not been fully characterized. Furthermore, acute inflammation is normally followed by an active resolution phase requiring specialized proresolving lipid mediators (SPMs) and allowing return to homeostasis. However, altered SPMs biosynthesis has been reported in CF. Here, we explored cilia beating dynamics in CF airways primary cultures and its response to the SPMs, resolvin E1 (RvE1) and lipoxin B4 (LXB4). Human nasal epithelial cells (hNECs) from CF and non-CF donors were grown at air-liquid interface. The ciliary beat frequency, synchronization, orientation, and density were analyzed from high-speed video microscopy using a multiscale Differential Dynamic Microscopy algorithm and an in-house developed method. Mucins and ASL layer height were studied by qRT-PCR and confocal microscopy. Principal component analysis showed that CF and non-CF hNEC had distinct cilia beating phenotypes, which was mostly explained by differences in cilia beat organization rather than frequency. Exposure to RvE1 (10 nM) and to LXB4 (10 nM) restored a non-CF-like cilia beating phenotype. Furthermore, RvE1 increased the airway surface liquid (ASL) layer height and reduced the mucin MUC5AC thickness. The calcium-activated chloride channel, TMEM16A, was involved in the RvE1 effect on cilia beating, hydration, and mucus. Altogether, our results provide evidence for defective cilia beating in CF airway epithelium and a role of RvE1 and LXB4 to restore the main epithelial functions involved in the mucociliary clearance.


Subject(s)
Cystic Fibrosis , Eicosapentaenoic Acid/analogs & derivatives , Humans , Cilia , Nasal Mucosa , Inflammation
4.
Aust Crit Care ; 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38267269

ABSTRACT

BACKGROUND: Tidal volume (Vt) delivery during mechanical ventilation is influenced by gas compression, humidity, and temperature. OBJECTIVES: This bench study aimed at assessing the accuracy of Vt delivery by paediatric intensive care ventilators according to the humidification system. Secondary objectives were to assess the following: (i) the accuracy of Vt delivery in ventilators with an integrated Y-piece pneumotachograph and (ii) the ability of ventilators to deliver and maintain a preset positive end-expiratory pressure. METHODS: Six latest-generation intensive care ventilators equipped with a paediatric mode were tested on the ASL5000 test lung in four simulated paediatric bench models (full-term neonate, infant, preschool-age chile, and school-age child), under volume-controlled mode with a heated humidifier (HH) or a heat moisture exchanger, with various loading conditions. Three ventilators equipped with a Y-piece pneumotachograph were tested with or without the pneumotachograph in the neonatal and infant models. "Accurate Vt" delivery was defined as a volume error (percentage of the preset Vt under body temperature and pressure and saturated water vapour conditions) being ≤10 % of the absolute preset value. RESULTS: Vt accuracy varied significantly across ventilators but was acceptable in almost all the ventilators and all the models, except the neonatal model. The humidification system had an impact on Vt delivery in the majority of the tested conditions (p < 0.05). The use of an HH was associated with a better Vt accuracy in four ventilators (V500, V800, R860, and ServoU) and allowed to achieve an acceptable level of volume error in the neonatal model as compared to the use of heat moisture exchanger. The use of an integrated pneumotachograph was associated with lower volume error in only one ventilator (p < 0.01). All the tested ventilators were able to maintain adequate positive end-expiratory pressure levels. CONCLUSION: The humidification system affects Vt accuracy of paediatric intensive care ventilators, especially in the youngest patients for whom the HH should be preferred.

5.
Ann Intensive Care ; 14(1): 18, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38285231

ABSTRACT

BACKGROUND: Inhaled sedation during invasive mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) has received increasing attention. However, inhaled sedation devices increase dead-space ventilation and an undesirable effect is the increase in minute ventilation needed to maintain CO2 removal. A consequence of raising minute ventilation is an increase in mechanical power (MP) that can promote lung injury. However, the effect of inhaled sedation devices on MP remains unknown. METHODS: We conducted a bench study to assess and compare the effects of three devices delivering inhaled sevoflurane currently available in ICU (AnaConDa-50 mL (ANA-50), AnaConDa-100 mL (ANA-100), and MIRUS) on MP by using a test lung model set with three compliances (20, 40, and 60 mL/cmH2O). We simulated lung-protective ventilation using a low tidal volume and two levels of positive end-expiratory pressure (5 and 15 cmH2O) under ambient temperature and dry conditions. Following the insertion of the devices, either the respiratory rate or tidal volume was increased in 15%-steps until end-tidal CO2 (EtCO2) returned to the baseline value. MP was calculated at baseline and after EtCO2 correction using a simplified equation. RESULTS: Following device insertion, the EtCO2 increase was significantly greater with MIRUS (+ 78 ± 13%) and ANA-100 (+ 100 ± 11%) than with ANA-50 (+ 49 ± 7%). After normalizing EtCO2 by adjusting minute ventilation, MP significantly increased by more than 50% with all inhaled sedation devices compared to controls. The lowest increase in MP was observed with ANA-50 (p < 0.05 versus ANA-100 and MIRUS). The Costa index, another parameter assessing the mechanical energy delivered to the lungs, calculated as driving pressure × 4 + respiratory rate, significantly increased by more than 20% in all experimental conditions. Additional experiments performed under body temperature, ambient pressure, and gas saturated with water vapor conditions, confirmed the main results with an increase in MP > 50% with all devices after normalizing EtCO2 by adjusting minute ventilation. CONCLUSION: Inhaled sedation devices substantially increased MP in this bench model of protective ventilation, which might limit their benefits in ARDS.

6.
Sci Rep ; 13(1): 20393, 2023 11 21.
Article in English | MEDLINE | ID: mdl-37989865

ABSTRACT

Our goal was to investigate the effects of head-thorax elevation (HUP) during chest compressions (CC) on lung ventilation. A prospective study was performed on seven human cadavers. Chest was automatically compressed-decompressed in flat position and during progressive HUP from 18 to 35°. Lung ventilation was measured with electrical impedance tomography. In each cadaver, 5 sequences were randomly performed: one without CC at positive end-expiratory pressure (PEEP) 0cmH2O, 3 s with CC at PEEP0, 5 or 10cmH2O and 1 with CC and an impedance threshold device at PEEP0cmH2O. The minimal-to-maximal change in impedance (VTEIT in arbitrary unit a.u.) and the minimal impedance in every breathing cycle (EELI) the) were compared between flat, 18°, and 35° in each sequence by a mixed-effects model. Values are expressed as median (1st-3rd quartiles). With CC, between flat, 18° and 35° VTEIT decreased at each level of PEEP. It was 12416a.u. (10,689; 14,442), 11,239 (7667; 13,292), and 6457 (4631; 9516), respectively, at PEEP0. The same was true with the impedance threshold device. EELI/VTEIT significantly decreased from - 0.30 (- 0.40; - 0.15) before to - 1.13 (- 1.70; - 0.61) after the CC (P = 0.009). With HUP lung ventilation decreased with CC as compared to flat position. CC are associated with decreased in EELI.


Subject(s)
Positive-Pressure Respiration , Respiration, Artificial , Humans , Prospective Studies , Positive-Pressure Respiration/adverse effects , Thorax/diagnostic imaging , Electric Impedance , Cadaver , Lung
7.
Diagnostics (Basel) ; 13(18)2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37761341

ABSTRACT

Primary ciliary dyskinesia is a heterogeneous, inherited motile ciliopathy in which respiratory cilia beat abnormally, and some ultrastructural ciliary defects and specific genetic mutations have been associated with particular ciliary beating alterations. Ciliary beating can be evaluated using digital high-speed videomicroscopy (DHSV). However, normal reference values, essential to assess ciliary beating in patients referred for a PCD diagnostic, vary between centres, as minor variations in protocols might influence ciliary beating. Consequently, establishment of normal values is essential for each PCD diagnostic centre. We aimed to evaluate whether delay after sampling, and temperature for conservation of respiratory ciliated samples, might modify assessments of ciliary beating. In total, 37 healthy nasal brushing samples of respiratory ciliated epithelia were collected. Video sequences were recorded at 37 °C immediately using DHSV. Then, the samples were divided and conserved at 4 °C or at room temperature (RT). Ciliated beating edges were then recorded at 37 °C, at 3 h and at 9 h post sampling. In six samples, recordings were continued up to 72 h after sampling. Ciliary beating was assessed manually by ciliary beat frequency (CBFM) and ciliary beat pattern (CBP). A semi-automatic software was used for quantitative analysis. Both CBF and CBP evaluated manually and by a semi-automated method were stable 9 h after sampling. CBFM was higher when evaluated using samples stored at RT than at 4 °C. CBP and the semi-automated evaluation of ciliary beating were not affected by storage temperature. When establishing normal references values, ciliary beating can be evaluated at 37 °C up to 9 h after nasal brushing, but the storage temperature modifies ciliary beating and needs to be controlled.

8.
Crit Care ; 27(1): 273, 2023 07 07.
Article in English | MEDLINE | ID: mdl-37420282

ABSTRACT

BACKGROUND: Airway opening pressure (AOP) detection and measurement are essential for assessing respiratory mechanics and adapting ventilation. We propose a novel approach for AOP assessment during volume assist control ventilation at a usual constant-flow rate of 60 L/min. OBJECTIVES: To validate the conductive pressure (Pcond) method, which compare the Pcond-defined on the airway pressure waveform as the difference between the airway pressure level at which an abrupt change in slope occurs at the beginning of insufflation and PEEP-to resistive pressure for AOP detection and measurement, and to compare its respiratory and hemodynamic tolerance to the standard low-flow insufflation method. METHODS: The proof-of-concept of the Pcond method was assessed on mechanical (lung simulator) and physiological (cadavers) bench models. Its diagnostic performance was evaluated in 213 patients, using the standard low-flow insufflation method as a reference. In 45 patients, the respiratory and hemodynamic tolerance of the Pcond method was compared with the standard low-flow method. MEASUREMENTS AND MAIN RESULTS: Bench assessments validated the Pcond method proof-of-concept. Sensitivity and specificity of the Pcond method for AOP detection were 93% and 91%, respectively. AOP obtained by Pcond and standard low-flow methods strongly correlated (r = 0.84, p < 0.001). Changes in SpO2 were significantly lower during Pcond than during standard method (p < 0.001). CONCLUSION: Determination of Pcond during constant-flow assist control ventilation may permit to easily and safely detect and measure AOP.


Subject(s)
Insufflation , Humans , Insufflation/methods , Lung , Respiratory Physiological Phenomena , Respiratory Mechanics , Respiration, Artificial/methods
9.
Int J Mol Sci ; 24(7)2023 Mar 23.
Article in English | MEDLINE | ID: mdl-37047067

ABSTRACT

Chronic rhinosinusitis with nasal polyps (CRSwNP) is a typical type-2 inflammation involving several cytokines and is associated with epithelial cell dysfunction. Oncostatin M (OSM) (belonging to the interleukin(IL)-6 family) could be a key driver of epithelial barrier dysfunction. Therefore, we investigated the presence of OSM and IL-6 and the expression pattern of tight junctions (TJs) in the nasal tissue of CRSwNP patients and controls using reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) and Western blotting. Then, their potential role in the epithelial barrier was evaluated in vitro in 27 different primary cultures of human nasal epithelial cells (HNECs) by measuring TJ expression and transepithelial electric resistance (TEER) with or without OSM or IL-6 (1, 10, and 100 ng/mL). The effect on ciliary beating efficiency was evaluated by high-speed videomicroscopy and on repair mechanisms with a wound healing model with or without OSM. OSM and IL-6 were both overexpressed, and TJ (ZO-1 and occludin) expression was decreased in the nasal polyps compared to the control mucosa. OSM (100 ng/mL) but not IL-6 induced a significant decrease in TJ expression, TEER, and ciliary beating efficiency in HNECs. After 24 h, the wound repair rate was significantly higher in OSM-stimulated HNECs at 100 ng/mL. These results suggest that OSM could become a new target for monoclonal antibodies.


Subject(s)
Nasal Polyps , Rhinitis , Sinusitis , Humans , Cells, Cultured , Chronic Disease , Epithelial Cells/metabolism , Nasal Mucosa/metabolism , Oncostatin M/pharmacology , Oncostatin M/metabolism , Sinusitis/metabolism , Tight Junctions/metabolism
10.
Respir Care ; 68(4): 462-469, 2023 04.
Article in English | MEDLINE | ID: mdl-36963968

ABSTRACT

BACKGROUND: Mechanical insufflation-exsufflation (MI-E) devices are used to improve airway clearance in individuals with acute respiratory failure. Some MI-E devices measure cough peak flow (CPF) during MI-E to optimize pressure adjustments. The aim was to compare CPF and effective cough volume (ECV: volume expired/coughed > 3 L/s) measurements between 4 MI-E devices under simulated conditions of stable versus collapsed airway. METHODS: Four MI-E devices were tested on the bench. Each device was connected via a standard circuit to a collapsible tube placed in an airtight chamber that was attached to a lung model with adjustable compliance and resistance. Pressure was measured upstream and downstream the collapsing tube; air flow was measured between the chamber and the lung model. Each device was tested in 2 conditions: collapse condition (0 cm H2O) and no-collapse condition (-70 cm H2O). For each condition, 6 combinations of inspiratory/expiratory pressures were applied. CPF was measured at the "mouth level" by the device built-in flow meter and at the "tracheal level" by a dedicated pneumotachograph. Comparisons were performed with non-parametric tests. RESULTS: CPF values measured at the tracheal level and ECV values differed between devices for each inspiratory/expiratory pressure in the collapse and no-collapse conditions (P < .001). CPF values were significantly lower at the tracheal level in the collapse as compared with the no-collapse condition (P < .001 for each device), whereas they were higher at the mouth level (P < .05) for 3 of the 4 devices. CONCLUSIONS: CPF values differed significantly across MI-E devices, highlighting limitation(s) of using only CPF values to determine cough effectiveness. In simulated of airway collapse, CPF increased at the mouth, whereas it decreased at the tracheal level.


Subject(s)
Cough , Insufflation , Humans , Respiration, Artificial , Lung , Peak Expiratory Flow Rate
11.
Int J Mol Sci ; 24(4)2023 Feb 07.
Article in English | MEDLINE | ID: mdl-36834705

ABSTRACT

In early 2020, the novel pathogenic severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged in Wuhan, China, and rapidly propagated worldwide causing a global health emergency. SARS-CoV-2 binds to the angiotensin-converting enzyme 2 (ACE2) protein for cell entry, followed by proteolytic cleavage of the Spike (S) protein by the transmembrane serine protease 2 (TMPRSS2), allowing fusion of the viral and cellular membranes. Interestingly, TMPRSS2 is a key regulator in prostate cancer (PCa) progression which is regulated by androgen receptor (AR) signaling. Our hypothesis is that the AR signaling may regulate the expression of TMPRSS2 in human respiratory cells and thus influence the membrane fusion entry pathway of SARS-CoV-2. We show here that TMPRSS2 and AR are expressed in Calu-3 lung cells. In this cell line, TMPRSS2 expression is regulated by androgens. Finally, pre-treatment with anti-androgen drugs such as apalutamide significantly reduced SARS-CoV-2 entry and infection in Calu-3 lung cells but also in primary human nasal epithelial cells. Altogether, these data provide strong evidence to support the use of apalutamide as a treatment option for the PCa population vulnerable to severe COVID-19.


Subject(s)
COVID-19 , Male , Humans , COVID-19/metabolism , SARS-CoV-2/metabolism , Peptidyl-Dipeptidase A/metabolism , Lung/metabolism , Epithelial Cells/metabolism , Virus Internalization
12.
Pediatr Pulmonol ; 58(1): 66-72, 2023 01.
Article in English | MEDLINE | ID: mdl-36102687

ABSTRACT

BACKGROUND: Inappropriate humidification of inspired gas during mechanical ventilation can impair lung development in extremely low birthweight (ELBW) infants. Humidification depends on multiple factors, such as the heater-humidifier device used, type of ventilation, and environmental factors. Few studies have examined inspired gas humidification in these infants, especially during high-frequency oscillatory ventilation (HFOV). Our objective was to compare humidity during HFOV and intermittent positive pressure ventilation (IPPV), in vitro and in vivo. METHODS: In vitro and in vivo studies used the same ventilator during both HFOV and IPPV. The bench study used a neonatal test lung and two heater-humidifiers with their specific circuits; the in vivo study prospectively included preterm infants born before 28 weeks of gestation. RESULTS: On bench testing, mean absolute (AH) and relative (RH) humidity values were significantly lower during HFOV than IPPV (RH = 79.4 ± 8.1% vs. 89.0 ± 6.2%, p < 0.001). Regardless of the ventilatory mode, mean RH significantly differed between the two heater-humidifiers (89.6 ± 6.7% vs 78.7 ± 6.8%, p = 0.003). The in vivo study included 10 neonates (mean ± SD gestational age: 25.7 ± 0.9 weeks and birthweight: 624.4 ± 96.1 g). Mean RH during HFOV was significantly lower than during IPPV (74.6 ± 5.7% vs. 83.0 ± 6.7%, p = 0.004). CONCLUSION: RH was significantly lower during HFOV than IPPV, both in vitro and in vivo. The type of heater-humidifier also influenced humidification. More systematic measurements of humidity of inspired gas, especially during HFOV, should be considered to optimize humidification and consequently lung protection in ELBW infants.


Subject(s)
High-Frequency Ventilation , Respiratory Distress Syndrome, Newborn , Infant, Newborn , Humans , Infant , Intermittent Positive-Pressure Ventilation , Humidity , Infant, Extremely Premature , Respiratory Distress Syndrome, Newborn/therapy
13.
Respir Care ; 68(1): 18-30, 2023 01.
Article in English | MEDLINE | ID: mdl-36220193

ABSTRACT

BACKGROUND: Noninvasive ventilation (NIV) is the reference standard treatment for most situations of chronic respiratory failure. NIV settings must be titrated to both preserve upper-airway patency and control hypoventilation. Automatic adjustment of pressure support (PS) and expiratory positive airway pressure (EPAP) may facilitate the initiation and follow-up of domiciliary NIV. However, whether the automatic-adjustment algorithms embedded into current devices accurately detect, respond to, and score common sleep-related respiratory events remains unclear. METHODS: A bench was set up to simulate central hypopnea (CH), central apnea (CA), obstructive hypopnea (OH), and obstructive apnea (OA). Four home ventilators were evaluated, with their dedicated modes for automatic PS and EPAP adjustment. RESULTS: All 4 devices increased PS during CH, CA, and OH. However, PS adjustment varied widely in magnitude, with tidal volumes within 100 ± 20% of the target being provided by only 3 devices for CH, one for CA, and one for OH. Two devices increased EPAP for OH and 3 for OA, including one that also increased EPAP for CA. Only 2 devices scored residual hypopnea after simulated CA, and only one scored a residual event after OH. One device scored no event. CONCLUSIONS: Current NIV devices differed markedly in their responses to, and reporting of, standardized sleep-related respiratory events. Further improvements in embedded NIV algorithms are needed to allow more widespread out-of-laboratory initiation and follow-up of NIV.


Subject(s)
Noninvasive Ventilation , Sleep Apnea Syndromes , Sleep Apnea, Central , Sleep Apnea, Obstructive , Humans , Sleep/physiology , Positive-Pressure Respiration , Sleep Apnea Syndromes/therapy
14.
Sci Rep ; 12(1): 21053, 2022 12 06.
Article in English | MEDLINE | ID: mdl-36473907

ABSTRACT

The 2019 global coronavirus (COVID-19) pandemic has brought the world to a grinding halt, highlighting the urgent need for therapeutic and preventive solutions to slow the spread of emerging viruses. The objective of this study was to assess the anti-SARS-CoV-2 effectiveness of 8 FDA-approved cationic amphiphilic drugs (CADs). SARS-CoV-2-infected Vero cells, Calu-3 cells and primary Human Nasal Epithelial Cells (HNEC) were used to investigate the effects of CADs and revealed their antiviral mode of action. Among the CADs tested, desloratadine, a commonly used antiallergic, well-tolerated with no major side effects, potently reduced the production of SARS-CoV-2 RNA in Vero-E6 cells. Interestingly, desloratadine was also effective against HCoV-229E and HCoV-OC43 showing that it possessed broad-spectrum anti-coronavirus activity. Investigation of its mode of action revealed that it targeted an early step of virus lifecycle and blocked SARS-CoV-2 entry through the endosomal pathway. Finally, the ex vivo kinetic of the antiviral effect of desloratadine was evaluated on primary Human Nasal Epithelial Cells (HNEC), showing a significant delay of viral RNA production with a maximal reduction reached after 72 h of treatment. Thus, this treatment could provide a substantial contribution to prophylaxis and systemic therapy of COVID-19 or other coronaviruses infections and requires further studies.


Subject(s)
COVID-19 , Virus Internalization , Chlorocebus aethiops , Animals , Humans , SARS-CoV-2 , Vero Cells , RNA, Viral , Cell Culture Techniques
15.
J Extracell Vesicles ; 11(10): e12269, 2022 10.
Article in English | MEDLINE | ID: mdl-36271885

ABSTRACT

Small Extracellular Vesicles (sEVs) are 50-200 nm in diameter vesicles delimited by a lipid bilayer, formed within the endosomal network or derived from the plasma membrane. They are secreted in various biological fluids, including airway nasal mucus. The goal of this work was to understand the role of sEVs present in the mucus (mu-sEVs) produced by human nasal epithelial cells (HNECs) in SARS-CoV-2 infection. We show that uninfected HNECs produce mu-sEVs containing SARS-CoV-2 receptor ACE2 and activated protease TMPRSS2. mu-sEVs cleave prefusion viral Spike proteins at the S1/S2 boundary, resulting in higher proportions of prefusion S proteins exposing their receptor binding domain in an 'open' conformation, thereby facilitating receptor binding at the cell surface. We show that the role of nasal mu-sEVs is to complete prefusion Spike priming performed by intracellular furin during viral egress from infected cells. This effect is mediated by vesicular TMPRSS2 activity, rendering SARS-CoV-2 virions prone to entry into target cells using the 'early', TMPRSS2-dependent pathway instead of the 'late', cathepsin-dependent route. These results indicate that prefusion Spike priming by mu-sEVs in the nasal cavity plays a role in viral tropism. They also show that nasal mucus does not protect from SARS-CoV-2 infection, but instead facilitates it.


Subject(s)
COVID-19 , Extracellular Vesicles , Humans , Spike Glycoprotein, Coronavirus/chemistry , Furin , Angiotensin-Converting Enzyme 2 , SARS-CoV-2 , Proviruses/metabolism , Lipid Bilayers , Virus Internalization , Epithelial Cells/metabolism , Extracellular Vesicles/metabolism , Cathepsins
16.
Langmuir ; 38(34): 10512-10519, 2022 08 30.
Article in English | MEDLINE | ID: mdl-35979644

ABSTRACT

Dynamics with an orientational degree of freedom are fundamental in biological events. Probes with polarized luminescence enable a determination of the orientation. Lanthanide-doped nanocrystals can provide more precise analysis than quantum dots due to the nonphotoblinking/bleaching nature and the multiple line-shaped emission. However, the intrinsic polarization property of the original nanocrystals often deteriorates in complex physiological environments because the colloidal stability easily breaks and the probes aggregate in the media with abundant salts and macromolecules. Engineering the surface chemistry of the probes is thus essential to be compatible with biosystems, which has remained a challenging task that should be exclusively addressed for each specific probe. Here, we demonstrate a facile and efficient surface functionalization of lanthanide-doped nanorods by zwitterionic block copolymers. Due to the steric interaction and the intrinsic zwitterionic nature of the polymers, high colloidal stability of the zwitterionic nanorod suspension is achieved over wide ranges of pH and concentration of salts, even giving rise to the lyotropic liquid crystalline behavior of the nanorods in physiological media. The shear-aligned ability is shown to be unaltered by the coated polymers, and thus, the strongly polarized emission of Eu3+ is preserved. Besides, biological experiments reveal good biocompatibility of the zwitterionic nanorods with negligible nonspecific binding. This study is a stepping stone for the use of the nanorods as orientation probes in biofluids and validates the strategy of coupling zwitterions to lanthanide-doped nanocrystals for various bioapplications.


Subject(s)
Biosensing Techniques , Lanthanoid Series Elements , Quantum Dots , Lanthanoid Series Elements/chemistry , Polymers , Quantum Dots/chemistry , Salts
17.
Respir Care ; 67(9): 1129-1137, 2022 09.
Article in English | MEDLINE | ID: mdl-35790397

ABSTRACT

BACKGROUND: Oxygen therapy via high-flow nasal cannula (HFNC) has been extensively used during the COVID-19 pandemic. The number of devices has also increased. We conducted this study to answer the following questions: Do HFNC devices differ from the original device for work of breathing (WOB) and generated PEEP? METHODS: Seven devices were tested on ASL 5000 lung model. Compliance was set to 40 mL/cm H2O and resistance to 10 cm H2O/L/s. The devices were connected to a manikin head via a nasal cannula with FIO2 set at 0.21. The measurements were performed at baseline (manikin head free of nasal cannula) and then with the cannula and the device attached with oxygen flow set at 20, 40, and 60 L/min. WOB and PEEP were assessed at 3 simulated inspiratory efforts (-5, -10, -15 cm H2O muscular pressure) and at 2 breathing frequencies (20 and 30 breaths/min). Data were expressed as median (first-third quartiles) and compared with nonparametric tests to the Optiflow device taken as reference. RESULTS: Baseline WOB and PEEP were comparable between devices. Over all the conditions tested, WOB was 4.2 (1.0-9.4) J/min with the reference device, and the relative variations from it were 0, -3 (2-4), 1 (0-1), -2 (1-2), -1 (1-2), and -1 (1-2)% with Airvo 2, G5, HM80, T60, V500, and V60 Plus devices, respectively, (P < .05 Kruskal-Wallis test). PEEP was 0.9 (0.3-1.5) cm H2O with Optiflow, and the relative differences were -28 (22-33), -41 (38-46), -30 (26-36), -31 (28-34), -37 (32-42), and -24 (21-34)% with Airvo 2, G5, HM80, T60, V500, and V60 Plus devices, respectively, (P < .05 Kruskal-Wallis test). CONCLUSIONS: WOB was marginally higher and PEEP marginally lower with devices as compared to the reference device.


Subject(s)
COVID-19 , Oxygen , Cannula , Humans , Oxygen Inhalation Therapy , Pandemics , Work of Breathing
19.
Neonatology ; 119(3): 386-393, 2022.
Article in English | MEDLINE | ID: mdl-35504256

ABSTRACT

INTRODUCTION: Synchronization of non-invasive ventilation is challenging in extremely premature infants. We compared patient-ventilator synchrony between non-invasive neurally adjusted ventilatory assist (NIV-NAVA) using transdiaphragmatic (Edi) catheter and synchronized intermittent positive airway pressure (SiPAP) using an abdominal trigger. METHODS: This study was a monocentric, randomized, crossover trial in premature infants born before 28 weeks of gestation, aged 3 days or more, and below 32 weeks postmenstrual age. NIV-NAVA and SiPAP were applied in a random order for 2 h with analysis of data from the second hour. The primary outcome was the asynchrony index. RESULTS: Fourteen patients were included (median [IQR] gestational age at birth 25.6 (25.3-26.4) weeks, median [IQR] birth weight 755 [680-824] g, median [IQR] postnatal age 26.5 [19.8-33.8] days). The median (IQR) asynchrony index was significantly lower in NIV-NAVA versus SiPAP (49.9% [44.1-52.6] vs. 85.8% [74.2-90.9], p < 0.001). Ineffective efforts and auto-triggering were significantly less frequent in NIV-NAVA versus SiPAP (3.0% vs. 32.0% p < 0.001 and 10.0% vs. 26.6%, p = 0.004, respectively). Double triggering was significantly less frequent in SiPAP versus NIV-NAVA (0.0% vs. 9.0%, p < 0.001). No significant difference was observed for premature cycling and late cycling. Peak Edi and swing Edi were significantly lower in NIV-NAVA as compared to SiPAP (7.7 [6.1-9.9] vs. 11.0 [6.7-14.5] µV, p = 0.006; 5.4 [4.2-7.6] vs. 7.6 [4.3-10.8] µV, p = 0.007, respectively). No significant difference was observed between NIV-NAVA and SiPAP for heart rate, respiratory rate, COMFORTneo scores, apnoea, desaturations, or bradycardias. DISCUSSION/CONCLUSION: NIV-NAVA markedly improves patient-ventilator synchrony as compared to SiPAP in extremely premature infants.


Subject(s)
Interactive Ventilatory Support , Noninvasive Ventilation , Cross-Over Studies , Humans , Infant , Infant, Extremely Premature , Infant, Newborn , Pilot Projects , Ventilators, Mechanical
20.
Laryngoscope Investig Otolaryngol ; 7(2): 388-394, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35434327

ABSTRACT

Background: Internal valve collapse is a frequent cause of nasal obstruction but remains poorly understood and is sometimes treated inappropriately as a result. No functional or imaging test for the condition has been validated and the reference diagnostic technique is physical examination. The objective of this study was to evaluate the potential of four-phase rhinomanometry as a diagnostic test for internal valve collapse. Methods: In a case-control diagnostic accuracy study, the nostrils of adult patients consulting for chronic nasal obstruction were classified as "collapsed" or "non-collapsed" based on clinical findings. Four-phase rhinomanometry was performed in all patients. The area defined by the path of the flow/pressure curve in the two phases of inspiration (the "inspiratory loop area" or "hysteresis loop area") was calculated for both nasal cavities and the threshold value with the highest Youden index was identified. Results: Sixty-six patients (132 nostrils) were included with 72 nostrils classified as collapsed and 60 as non-collapsed. Before nasal decongestion, the inspiratory loop area with the highest Youden index was 17.3 Pa L s-1 and the corresponding sensitivity and specificity were 88.3% (95% confidence interval, 80.0-95.0%) and 89.9% (82.6-95.7%), respectively. Conclusions: In these patients, a cutoff inspiratory loop area in four-phase rhinomanometry data reproduced clinical diagnoses of internal valve collapse with high sensitivity and specificity. This method may offer a firmer basis for treatment indications than subjective physical examinations. Level of evidence: Level 4.

SELECTION OF CITATIONS
SEARCH DETAIL
...