Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Radiol Case Rep ; 18(5): 1895-1897, 2023 May.
Article in English | MEDLINE | ID: mdl-36942006

ABSTRACT

Gastropulmonary fistula represents a late complication of sleeve gastrectomy and, if untreated, has high morbidity and mortality. We present a case report of a 29-year-old female who developed a gastropulmonary fistula 3 years after a sleeve gastrectomy. Dual energy CT of the chest and upper abdomen demonstrated a cavitary left lower lobe lesion associated with a focal complex pleural effusion; iodinated oral contrast confirmed the presence of a fistulous connection through the left hemidiaphragm. The patient underwent a thoracotomy, left lower lobectomy, resection of the infected segment of the left hemidiaphragm with primary repair, drainage of a subphrenic abscess and a gastric repair; the patient was discharged 2-weeks postprocedure.

2.
Can Assoc Radiol J ; 72(3): 557-563, 2021 Aug.
Article in English | MEDLINE | ID: mdl-32391715

ABSTRACT

Traumatic lower urinary tract injuries are uncommon and mainly occur in patients with severe trauma and multiple abdominopelvic injuries. In the presence of other substantial injuries, bladder and urethral injuries may be overlooked and cause significant morbidity and mortality. Therefore, it is important that radiologists are familiar with mechanisms and injuries that are high risk for bladder and urethral trauma. We review the imaging findings associated with these injuries and the appropriate modalities and techniques to further evaluate the patient and accurately diagnose these injuries. Computed tomography cystography and conventional retrograde urethrography are effective tools in identifying injuries to the lower urinary tract and play a crucial role in patient care and prognosis.


Subject(s)
Urethra/injuries , Urinary Bladder/injuries , Wounds and Injuries/diagnostic imaging , Cystography , Humans , Tomography, X-Ray Computed , Urethra/diagnostic imaging , Urinary Bladder/diagnostic imaging , Wounds and Injuries/etiology , Wounds and Injuries/therapy
3.
Can Assoc Radiol J ; 71(3): 388-395, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32174156

ABSTRACT

A mass casualty incident (MCI) is an event that generates more patients at one time than locally available resources can manage using routine procedures. By their nature, many of these incidents have no prior notice but result in large numbers of casualties with injuries that range in severity. They can happen anywhere and at any time and regional hospitals and health-care providers have to mount a response quickly and effectively to save as many lives as possible. Radiologists must go from passenger to pilot when it comes to MCI planning. When involved at the hospital-wide planning stage, they can offer valuable expertise on how radiology can improve triage accuracy and at what cost in terms of time and resources and thereby contribute a pragmatic understanding of radiology's role and value during MCIs. By taking ownership of MCI planning in their own departments, radiologists can ensure that the radiology department can respond quickly and effectively to unforeseen emergencies. Well-designed radiology protocols will save lives in an MCI setting.


Subject(s)
Disaster Planning , Emergency Service, Hospital/organization & administration , Mass Casualty Incidents , Organizational Policy , Radiology Department, Hospital/organization & administration , Wounds and Injuries/diagnostic imaging , Humans , Triage/methods
4.
J Thorac Imaging ; 34(6): 387-392, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30994517

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the clinical utility of temporal resolution optimization (TR-Opt), a computed tomography (CT) postprocessing technique, in reducing aortic motion artifacts in blunt thoracic trauma patients. MATERIALS AND METHODS: This was an IRB-approved study of 61 patients with blunt thoracic trauma carried out between February 18 and September 6, 2014; the patients had been imaged using a standardized dual-source high-pitch (DSHP) CT protocol. Image raw data were retrospectively postprocessed using the TR-Opt algorithm (DSHP-TR-Opt) and compared with conventional images (DSHP). Diagnostic ability to confidently identify and exclude potential injuries and qualitative aortic motion artifacts using a 5-point Likert scale (1=absence of motion artifacts; 5=severe motion artifact) was graded by 2 readers at multiple thoracic locations. Signal-to-noise and contrast-to-noise ratios were generated as quantitative indices of image quality. RESULTS: Motion artifacts degrading interpretation and limiting diagnosis of aortic injuries were present in 45% (442/976) of the assessed regions on DSHP. TR-Opt algorithm eliminated motion artifacts in 85% of the motion-degraded areas (375/442), leaving persistent motion artifacts in only 15% (67/442). Motion artifacts were most improved at the interventricular septum (1±1 vs. 3±1), aortic valve (2±1 vs. 4±1.5), and ascending aorta (1±1 vs. 3±2, P<0.005). Mean aorta noise (NAo) was 41.7% higher in the DSHP-TR-Opt images (26.5 vs. 18.7 HU, P<0.0001). CONCLUSIONS: Temporal resolution optimized reconstruction is a raw data-based CT postprocessing technique that can be used to remove the majority of thoracic aortic motion artifacts that commonly degrade interpretation when imaging blunt thoracic trauma patients.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Movement , Radiographic Image Interpretation, Computer-Assisted/methods , Thoracic Injuries/diagnostic imaging , Tomography, X-Ray Computed/methods , Wounds, Nonpenetrating/diagnostic imaging , Adolescent , Adult , Aged , Algorithms , Artifacts , Female , Humans , Male , Middle Aged , Retrospective Studies , Signal-To-Noise Ratio
5.
Emerg Radiol ; 26(3): 269-275, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30631994

ABSTRACT

PURPOSE: It is uncertain whether patients with elevated troponin and non-classical presentation of acute coronary syndrome (ACS) should receive coronary CT angiography (CCTA). A proportion of these patients will have no coronary artery disease (CAD) and would benefit from non-invasive investigations and expedited discharge. Objectives were to determine most common diagnoses and rate of ACS among patients with positive troponin and low clinical suspicion of ACS who received CCTA. METHODS: IRB approved retrospective analysis of 491 consecutive patients in a level I trauma center ED referred for CCTA between April 4, 2015 to April 2, 2017. Patients were included if there was an elevated troponin (TnI > 0.045 µg/L) and atypical chest pain within 24 h prior to imaging. One hundred one patients met inclusion criteria; 17 excluded due to technical factors or history. Scans performed on dual-source CT. RESULTS: Eighty-four patients (47 men, 37 women) with median TnI of 0.11 ± 0.21 µg/L underwent CCTA 8.20 ± 6.41 h after first elevated Tn. Mean age was 53.2 ± 14.6 years. CCTA demonstrated absence of CAD in 39 patients (46.4%; 20 M, 19 F). CAD < 25% stenosis was observed in 24 (28.6%; 9 M, 15 F). CAD with 25-50% stenosis was observed in seven (8.3%; six M, one F). CAD > 50% stenosis was observed in 11 (13.1%; 9 M, 2 F), and non-diagnostic in three (3.6%, 3 M, 0 F). Forty-six (56.8%) were discharged directly from ED with median stay 15.82 ± 6.41 h. CONCLUSIONS: Use of CCTA in ED patients with elevated troponin and low clinical suspicion for ACS allowed obstructive CAD to be excluded in 83%.


Subject(s)
Acute Coronary Syndrome/diagnostic imaging , Biomarkers/blood , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Emergency Service, Hospital , Troponin/blood , Acute Coronary Syndrome/blood , Chest Pain/blood , Chest Pain/diagnostic imaging , Coronary Artery Disease/blood , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Retrospective Studies , Unnecessary Procedures/statistics & numerical data
6.
Abdom Radiol (NY) ; 44(1): 355-361, 2019 01.
Article in English | MEDLINE | ID: mdl-29980828

ABSTRACT

PURPOSE: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). METHODS: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1-5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen's κ test. RESULTS: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). CONCLUSIONS: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.


Subject(s)
Image Processing, Computer-Assisted/methods , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Abdominal/methods , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Female , Humans , Male , Middle Aged , Retrospective Studies
8.
Radiology ; 284(3): 798-805, 2017 09.
Article in English | MEDLINE | ID: mdl-28301779

ABSTRACT

Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in the exclusion of these fractures. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on March 17, 2017.


Subject(s)
Bone Marrow/diagnostic imaging , Edema/diagnostic imaging , Hip Fractures/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Bone Marrow/pathology , Female , Humans , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity , Young Adult
9.
Emerg Radiol ; 23(2): 127-32, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26637401

ABSTRACT

The purpose of this study was to compare diaphragmatic motion on dual-source high-pitch (DS-HP) and conventional single-source (SS) CT scans in trauma patients. Seventy-five consecutive trauma patients who presented to a level one trauma center over a 6-month period were scanned with a standardized whole body trauma CT protocol including both DS-HP chest (pitch = 2.1-2.5) and SS abdominal CT scans. Subjective analysis of diaphragmatic motion was performed by two readers using a four-point motion scale in seven regions of the diaphragm on coronal and axial slices. An overall confidence score to exclude a diaphragmatic tear was determined (1 to 10, 10: completely confident and 1: impossible to exclude). Wilcoxon rank sum tests were used for statistical analysis, and p < 0.05 was considered significant. Mean confidence score of 9.85 for DS-HP was significantly better than the mean score of 7.66 for SS images (p < 0.0001). Diaphragmatic motion scores and subjective diaphragmatic motion artifact on coronal and axial images were significantly better for DS-HP images in all areas when compared individually (p < 0.0001) and overall (p < 0.0001). Regions of DS-HP (99.2 %) were diagnostic, whereas only 87.0 % % regions on SS were. Complete agreement of motion scores was present in 92 % of cases, with moderate overall agreement for confidence to exclude a diaphragmatic tear (κ = 0.45). Dual-source high-pitch CT scanning is advantageous as it allows for significantly better evaluation of diaphragmatic structures by minimizing motion artifacts on images of freely breathing trauma patients.


Subject(s)
Diaphragm/physiology , Tomography, X-Ray Computed/methods , Wounds, Nonpenetrating/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Artifacts , Diaphragm/injuries , Female , Humans , Male , Middle Aged , Motion , Respiration , Young Adult
10.
Radiol Clin North Am ; 53(4): 657-74, vii, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26046504

ABSTRACT

The high morbidity and mortality associated with cervical spine injuries makes identification and classification essential. It is important to have a systematic approach to evaluation, especially in the trauma setting with other distracting injuries. Understanding the anatomy and biomechanics enables rapid and accurate interpretation of images. In severe trauma and in patients with rigid spinal disease, the classic patterns of injury may be difficult or impossible to recognize. This article provides an approach to acquiring and interpreting cervical spine images in the setting of acute trauma and reviews the classic patterns of injury.


Subject(s)
Atlanto-Axial Joint/diagnostic imaging , Atlanto-Axial Joint/injuries , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/injuries , Fractures, Compression/diagnostic imaging , Spinal Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Critical Care/methods , Humans , Radiographic Image Enhancement/methods
11.
Abdom Imaging ; 40(5): 1255-62, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25296996

ABSTRACT

PURPOSE: The objective of this study is to establish the effect of third-generation integrated circuit (IC) CT detector on objective image quality in full- and half-dose non-contrast CT of the urinary tract. METHODS: 51 consecutive patients with acute renal colic underwent non-contrast CT of the urinary tract using a 128-slice dual-source CT before (n = 24) and after (n = 27) the installation of third-generation IC detectors. Half-dose images were generated using projections from detector A using the dual-source RAW data. Objective image noise in the liver, spleen, right renal cortex, and right psoas muscle was compared between DC and IC cohorts for full-dose and half-dose images reconstructed with FBP and IR algorithms using 1 cm(2) regions of interest. Presence and size of obstructing ureteric calculi were also compared for full-dose and half-dose reconstructions using DC and IC detectors. RESULTS: No statistical difference in age and lateral body size was found between patients in the IC and DC cohorts. Radiation dose, as measured by size-specific dose estimates, did not differ significantly either between the two cohorts (10.02 ± 4.54 mGy IC vs. 12.28 ± 7.03 mGy DC). At full dose, objective image noise was not significantly lower in the IC cohort as compared to the DC cohort for the liver, spleen, and right psoas muscle. At half dose, objective image noise was lower in the IC cohort as compared to DC cohort at the liver (21.32 IC vs. 24.99 DC, 14.7% decrease, p < 0.001), spleen (19.33 IC vs. 20.83 DC, 7.20% decrease, p = 0.02), and right renal cortex (20.28 IC vs. 22.98 DC, 11.7% decrease, p = 0.005). Mean obstructing ureteric calculi size was not significantly different when comparison was made between full-dose and half-dose images, regardless of detector type (p > 0.05 for all comparisons). CONCLUSIONS: Third-generation IC detectors result in lower objective image noise at full- and half-radiation dose levels as compared with traditional DC detectors. The magnitude of noise reduction was greater at half-radiation dose indicating that the benefits of using novel IC detectors are greater in low and ultra-low-dose CT imaging.


Subject(s)
Renal Colic/diagnostic imaging , Tomography, X-Ray Computed , Urolithiasis/diagnostic imaging , Adult , Aged , Contrast Media , Female , Humans , Male , Middle Aged , Multidetector Computed Tomography , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Renal Colic/etiology , Urolithiasis/complications
12.
J Comput Assist Tomogr ; 38(3): 348-51, 2014.
Article in English | MEDLINE | ID: mdl-24651751

ABSTRACT

Computed tomography has become increasingly popular in the assessment of limbs in the acute trauma setting. Bony anatomic detail is excellent; however, soft tissue detail is typically limited, especially when compared with ultrasound and magnetic resonance imaging. The advent of dual-energy computed tomography has allowed additional information to be gathered regarding the morphology of collagen-based soft tissue structures. We report our initial experiences of 4 cases with imaging and clinical correlation.


Subject(s)
Algorithms , Multiple Trauma/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Tendon Injuries/diagnostic imaging , Tendons/diagnostic imaging , Tomography, X-Ray Computed/methods , Acute Disease , Adult , Aged , Humans , Male , Middle Aged , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity
14.
Eur J Radiol ; 82(10): 1793-8, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23743054

ABSTRACT

OBJECTIVES/PURPOSE: Aim of this study was to retrospectively compare the image quality and the radiation dose of an ultra high pitch CT scan for the evaluation of pulmonary embolism and visualization of cardiac structures in comparison to our institution's standard pulmonary embolism protocol. METHOD AND MATERIALS: The study cohort consisted of 115 consecutive patients, 57 underwent CT pulmonary angiography on a dual source 128 slice scanner (Siemens Somatom Definition FLASH) via an ultra high pitch mode (Pitch 2.8) while 58 were scanned on a dual source 64 slice scanner (Siemens Somatom Definition Dual Source) with standard pitch (Pitch 0.9). Qualitative image assessment was determined by two blinded radiologists with 3 and 15 years' experience in chest and cardiac CT. Quantitative image assessment was determined by the signal to noise ratio (SNR) and contrast to noise ratio (CNR). Effective radiation dose was calculated via the product of the dose length product. RESULTS: For the ultra high pitch protocol, 14% (8/57) were positive for pulmonary embolus compared to 13.7% (8/58) for the standard pitch group. 98.2% of the ultra high pitch scans were diagnostic for pulmonary embolus vs. 94.8% of the standard protocol. Visualization of cardiac structures was significantly improved with the ultra high pitch protocol (p<0.0001). Significantly more lung parenchymal motion was observed on the standard protocol (p<0.0001). The mean pulmonary vessel attenuation, SNR, and CNR were not significantly different. The mean effective dose was lower for the ultra high pitch studies (4.09mSv±0.78 vs. 7.72mSv±2.60, p<0.0001). CONCLUSION: Ultra high pitch CT imaging for pulmonary embolus is a technique which has potential to assess motion free evaluation of most cardiac structures and proximal coronary arteries at lower radiation doses.


Subject(s)
Artifacts , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/epidemiology , Radiography, Dual-Energy Scanned Projection/statistics & numerical data , Radiography, Thoracic/statistics & numerical data , Respiratory-Gated Imaging Techniques/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Acute Disease , Adult , Aged , Aged, 80 and over , Angiography/statistics & numerical data , British Columbia/epidemiology , Emergency Medical Services/statistics & numerical data , Emergency Service, Hospital/statistics & numerical data , Female , Humans , Male , Middle Aged , Prevalence , Radiation Dosage , Reproducibility of Results , Risk Assessment , Sensitivity and Specificity , Young Adult
16.
Can Assoc Radiol J ; 64(2): 130-9, 2013 May.
Article in English | MEDLINE | ID: mdl-23541829

ABSTRACT

Blunt vascular neck injuries (BVNI), previously thought to be rare, have demonstrated increasing incidence rates in recent literature and are associated with significant mortality and morbidity. A radiologist needs to efficiently recognize these injuries on preliminary screening to enable initiation of early management. When initiation of accurate management is started promptly, decreased rates of postinjury complications, for example, stroke, have been demonstrated. This article reviews the incidence, pathophysiology, and rationale for screening for these BVNI injuries. The utility of computed tomography angiography (CTA) as the potential new criterion standard as the screening and follow-up imaging modality for BVNI will be discussed. The application of new multidetector CTA techniques available, such as dual-energy CT and iterative reconstruction, are also reviewed. In addition, the characteristic imaging findings on CTA and the associated Denver Grading scale for BVNI will be reviewed to allow readers to become familiar with the injury patterns and to understand the prognostic and clinical implications, respectively. Examples of the spectrum of injuries, potential injury mimics, and different artifacts on multidetector CTA are shown to help familiarize readers and allow them to successfully and confidently recognize a true BVNI.


Subject(s)
Cerebral Angiography/methods , Multidetector Computed Tomography , Neck Injuries/diagnostic imaging , Neck/blood supply , Vascular System Injuries/diagnostic imaging , Wounds, Nonpenetrating/diagnostic imaging , Humans
17.
J Thorac Cardiovasc Surg ; 144(2): 347-54, 354.e1, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22070925

ABSTRACT

OBJECTIVE: Delineation of blunt aortic injury by computed tomographic angiography guides management of this potentially fatal injury. Two existing grading systems are problematic to apply and not linked to outcomes. A simplified computed tomographic angiography-based grading system, linked to clinical outcomes, was developed, and feasibility and reliability were evaluated. METHODS: Retrospective review was performed of all blunt aortic injury cases presenting to a single provincial quaternary referral center designated for blunt aortic injury management between 2001 and 2009. Management, associated injuries, hospital survival, and cause of death were determined. Initial computed tomographic angiography was reviewed, and injuries were graded according to the new Vancouver simplified grading system by 2 study authors. Three additional trauma radiologists then graded the aortic injuries with the 2 existing systems and the simplified system. Interrater reliability was determined. RESULTS: Forty-eight patients were identified. Two had minimal aortic injury (grade I), 7 had an intimal flap larger than 1 cm (grade II), 32 had traumatic pseudoaneurysm (grade III), 6 had active contrast extravasation (grade IV), and 1 could not be rated. Survivals were 100%, 90%, and 33% for grades I and II, III, and IV, respectively. Of grade III injuries, 14% were medically managed, 68% repaired endovascularly, and 18% repaired with open surgery. Interrater correlation was best with the simplified score, with only 0.5% of cases unable to be classified. CONCLUSIONS: The Vancouver simplified blunt aortic injury grading system is easy to use and correlates with clinical outcomes. Prospective external validation is required.


Subject(s)
Angiography/methods , Aorta/injuries , Heart Injuries/classification , Heart Injuries/diagnostic imaging , Wounds, Nonpenetrating/classification , Wounds, Nonpenetrating/diagnostic imaging , Abbreviated Injury Scale , Adult , Aged , Comorbidity , Female , Heart Injuries/epidemiology , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Multidetector Computed Tomography , Multiple Trauma/epidemiology , Prognosis , Reproducibility of Results , Retrospective Studies , Wounds, Nonpenetrating/epidemiology , Young Adult
18.
Br J Sports Med ; 45(2): 140-6, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20966035

ABSTRACT

At the end of this article, the reader should be able to (1) recognise normal anatomy and anatomical variants of the extensor mechanism of the knee on various imaging modalities, including plain film, ultrasound and MRI; (2) diagnose a broad spectrum of EM injuries in adult and paediatric patients including patellar and quadriceps tendinopathy, Osgood-Schlatter disease, Sindig-Larsen-Johansson syndrome, chondromalacia patellae and patellar fractures on various imaging modalities; and (3) appreciate the important role of imaging in the diagnosis of musculoskeletal injuries.


Subject(s)
Knee Injuries/diagnosis , Adult , Bursitis/diagnosis , Child , Diagnostic Imaging/methods , Female , Fractures, Bone/diagnosis , Humans , Knee Joint/anatomy & histology , Male , Osteochondrosis/diagnosis , Patella/injuries , Patellar Dislocation/diagnosis , Patellar Ligament/anatomy & histology , Quadriceps Muscle/injuries , Rupture/diagnosis , Tendinopathy/diagnosis , Tendon Injuries/diagnosis
19.
AJR Am J Roentgenol ; 194(4): 1072-8, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20308513

ABSTRACT

OBJECTIVE: Gout is the most common crystal deposition arthropathy currently diagnosed clinically and with arthrocentesis. Dual-energy CT is a promising new imaging technique offering potential new applications in a number of clinical areas. CONCLUSION: The ability of dual-energy CT to diagnose early gout and its use as a problem-solving tool is shown here. Diagnosis of subclinical gout could avert associated long-term complications, thereby reducing disease burden and improving overall quality of life.


Subject(s)
Gout/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Software , Tomography, X-Ray Computed/instrumentation
20.
Article in English | MEDLINE | ID: mdl-30863192

ABSTRACT

Rotator cuff pathology is routinely evaluated in many imaging centers with both magnetic resonance imaging (MRI) and ultrasound. Despite good diagnostic accuracy using each of these modalities, certain limitations persist. In this pictorial essay, we describe five potential "troublemakers" of rotator cuff pathology which are recurrent themes in our busy shoulder referral center. The comparison of imaging findings on MRI and ultrasound are discussed. An awareness of these potential pitfalls will help improve radiologists' diagnostic accuracy of rotator cuff pathology, and allow the clinician to optimize imaging referral and better interpret the subsequent report.

SELECTION OF CITATIONS
SEARCH DETAIL
...