Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
JACC cardiovasc. interv ; 12(5): 433-443, Mar. 2019. tabela, gráfico
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024526

ABSTRACT

Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)


Subject(s)
Humans , Transcatheter Aortic Valve Replacement
2.
J Cardiovasc Med (Hagerstown) ; 15(7): 543-53, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24922045

ABSTRACT

Optical coherence tomography (OCT) is a light-based technology that provides very high spatial resolution images. OCT has been initially employed as a research tool to investigate plaque morphology and stent strut coverage. The introduction of frequency domain OCT allowing fast image acquisition during a prolonged contrast injection via the guiding catheter has made OCT applicable for guidance of coronary interventions. In this manuscript, the various applications of OCT are reviewed, from assessment of plaque vulnerability and severity to characteristics of unstable lesions and thrombus burden to stent optimization and evaluation of late results.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease/diagnosis , Coronary Vessels/pathology , Plaque, Atherosclerotic/diagnosis , Tomography, Optical Coherence/methods , Cardiac Catheterization , Coronary Artery Disease/surgery , Coronary Vessels/diagnostic imaging , Humans , Intraoperative Period , Plaque, Atherosclerotic/surgery , Reproducibility of Results , Ultrasonography, Interventional
SELECTION OF CITATIONS
SEARCH DETAIL
...