Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-35355780

ABSTRACT

Radiation exposure of orthopaedic residents should be accurately monitored to monitor and mitigate risk. The purpose of this study was to determine whether a personalized lead protocol (PLP) with a radiation monitoring officer would improve radiation exposure monitoring of orthopaedic surgery residents. Materials and Methods: This was a retrospective case-control study of 15 orthopaedic surgery residents monitored for radiation exposure during a 2-year period (March 2017 until February 2019). During the first 12-month period (phase 1), residents were given monthly radiation dosimeter badges and instructed to attach them daily to the communal lead aprons hanging outside the operating rooms. During the second 12-month period (phase 2), a PLP (PLP group) was instituted in which residents were given lead aprons embroidered with their individual names. A radiation safety officer was appointed who placed the badges monthly on all lead aprons and collected them at the end of the month, whereas faculty ensured residents wore their personalized lead apron. Data collected included fluoroscopy use time and radiation dosimeter readings during all orthopaedic surgeries in the study period. Results: There were 1,252 orthopaedic surgeries using fluoroscopy during phase 1 in the control group and 1,269 during phase 2 in the PLP group. The total monthly fluoroscopy exposure time for all cases averaged 190 minutes during phase 1 and 169 minutes during phase 2, with no significant difference between the groups (p < 0.45). During phase 1, 73.1% of the dosimeters reported radiation exposure, whereas during phase 2, 88.7% of the dosimeters reported radiation exposure (p < 0.001). During phase 1, the average monthly resident dosimeter exposure reading was 7.26 millirems (mrem) ± 37.07, vs. 19.00 mrem ± 51.16 during phase 2, which was significantly higher (p < 0.036). Conclusions: Institution of a PLP increased the compliance and exposure readings of radiation dosimeter badges for orthopaedic surgery residents, whereas the actual monthly fluoroscopy time did not change. Teaching hospitals should consider implementing a PLP to more accurately monitor exposure. Level of Evidence: 3.

2.
Cartilage ; 13(1_suppl): 928S-936S, 2021 12.
Article in English | MEDLINE | ID: mdl-33855864

ABSTRACT

OBJECTIVE: To compare radius of curvature (RoC) of distal femur osteochondral autograft transfer (OAT) donor sites from the intercondylar notch and trochlear ridge with recipient sites on the distal and posterior condyles and evaluate differences between recipient sites. DESIGN: Nineteen cadaveric femurs were scanned with a 3-dimensional high-resolution sensor. Donor regions included the lateral (LTR) and medial trochlear ridges (MTR), and the lateral (LICN) and medial intercondylar notch (MICN). Recipient regions analyzed were the distal medial (DMFC), posterior medial (PMFC), distal lateral (DLFC), and posterior lateral femur condyle (PLFC). Six-millimeter OAT grafts were simulated, and average RoC of all regions was compared using an analysis of variance. Post hoc testing was performed using Fisher's least significant difference. RESULTS: We found no significant differences in RoC of the LICN compared with all 4 recipient sites (P = 0.19, 0.97, 0.11, and 0.75 for DLFC, PLFC, DMFC, and PMFC, respectively) or the LTR and MTR to the posterior condyles (LTR vs. PLFC and PMFC; P = 0.72, 0.47, MTR vs. PLFC and PMFC P = 0.39, 0.22, respectively). Significant differences were found for RoC of the MICN compared with each recipient site (P < 0.001) and between distal and posterior femoral condyles (DLFC vs. PLFC, P = 0.016; DMFC vs. PMFC, P = 0.023). CONCLUSION: The LICN is the ideal donor option for all recipient sites on the femoral condyles with respect to RoC of 6-mm OAT plugs. The MTR and LTR were acceptable donor sources for the posterior condyles, while the MICN was a poor match for all recipient sites. Additionally, the distal femur condyle and posterior femur condyle have different RoCs.


Subject(s)
Autografts , Femur/surgery , Intra-Articular Fractures , Radius , Transplant Donor Site , Aged , Cadaver , Female , Humans , Knee , Male , Middle Aged , Transplantation, Autologous
SELECTION OF CITATIONS
SEARCH DETAIL
...