Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Res Food Sci ; 7: 100572, 2023.
Article in English | MEDLINE | ID: mdl-37664006

ABSTRACT

The increasing demand for seafood is responsible for many environmental impacts, especially caused by aquaculture. Shrimp accounts for a substantial part of seafood production and therefore also for negative effects associated with it. This work aimed to develop a mushroom-based shrimp analogue with a texture similar to shrimp using the fruiting bodies of pink oyster mushroom (Pleurotus djamor) and lion's mane (Hericium erinaceus). Three flushes of pink oyster mushrooms and a first flush of lion's mane mushroom were analysed regarding their nutritional composition and whether they are suitable shrimp alternatives. The two mushrooms are rich in proteins (∼32% and ∼26% w/w for the first flush of pink oyster and lion's mane, respectively). The protein content of pink oyster mushroom decreased and the dietary fibre content increased across the different flushes. The antioxidants in the mushrooms were extracted using different methods, whereby aqueous extracts mostly excelled in terms of antioxidant activity. Hydrolysis confirmed the presence of conjugated p-coumaric acid in both mushrooms and possibly conjugated caffeic acid in pink oyster. Texture analysis results of the prototypes were close to the values of fried shrimp. However, although the sensory qualities of the final prototypes were perceived as similar to shrimp, further improvements in the recipe are necessary to make the prototypes indistinguishable from shrimp.

2.
PLoS One ; 14(1): e0211207, 2019.
Article in English | MEDLINE | ID: mdl-30689658

ABSTRACT

Clinical flow cytometry is a reliable methodology for whole blood cell phenotyping for different applications. The BD FACSLyric™ system comprises a flow cytometer available in different optical configurations, BD FACSuite™ Clinical software, and optional BD FACS™ Universal Loader. BD FACSuite Clinical software used with BD™ FC Beads and BD CS&T Beads enable universal setup for performance QC, instrument control, data acquisition/storage, online/offline data analysis, and instrument standardization. BD Biosciences sponsored the clinical evaluation of the BD FACSLyric 10-color configuration at seven clinical sites using delinked and de-identified blood specimens from HIV-infected and uninfected subjects to enumerate T-, B-, and NK-lymphocytes with the BD Multitest™ reagents (BD Multitest IMK kit and BD Multitest 6-color TBNK). Samples were analyzed on the BD FACSLyric system with BD FACSuite Clinical software, and on the BD FACSCanto™ II system with BD FACSCanto clinical software and BD FACS 7-Color Setup beads. For equivalency between methods, data (n = 362) were analyzed with Deming regression for absolute count and percentage of lymphocytes. Results gave R2 ≥0.98, with slope values ≥0.96, and slope ranges between 0.90-1.05. The percent (%) bias values were <10% for T- and NK cells and <15% for B- cells. The between-site (n = 4) total precision was tested for 5 days (2 runs/day), and gave %coefficient of variation below 10% for absolute cell counts. The stability claims were confirmed (n = 186) for the two BD Multitest reagents. The reference intervals were re-established in male and female adults (n = 134). The analysis by gender showed statistically significant differences for CD3+ and CD4+ T-cell counts and %CD4. In summary, the BD FACSLyric and the BD FACSCanto II systems generated comparable measurements of T-, B-, and NK-cells using BD Multitest assays.


Subject(s)
B-Lymphocytes/cytology , Cell Count/methods , Killer Cells, Natural/cytology , T-Lymphocytes/cytology , CD4-Positive T-Lymphocytes/cytology , Cell Count/standards , Flow Cytometry , HIV Infections/blood , HIV Infections/diagnosis , HIV Infections/immunology , Humans , Reagent Kits, Diagnostic , Reference Standards , Reproducibility of Results
3.
Bioconjug Chem ; 29(3): 733-741, 2018 03 21.
Article in English | MEDLINE | ID: mdl-29318872

ABSTRACT

Short peptides are the minimal modality of antigen recognized by cellular immunity and are therefore considered a safe and highly specific source of antigen for vaccination. Nevertheless, successful peptide immunotherapy is limited by the short half-life of peptide antigens in vivo as well as their weak immunogenicity. We recently reported a vaccine strategy based on dendritic cell-recruiting Mesoporous Silica Rod (MSR) scaffolds to enhance T-cell responses against subunit antigen. In this study, we investigated the effect of covalently conjugating peptide antigens to MSRs to increase their retention in the scaffolds. Using both stable thioether and reducible disulfide linkages, peptide conjugation greatly increased peptide loading compared to passive adsorption. In vitro, Bone Marrow derived Dendritic Cells (BMDCs) could present Ovalbumin (OVA)-derived peptides conjugated to MSRs and induce antigen-specific T-cell proliferation. Stable conjugation decreased presentation in vitro while reducible conjugation maintained levels of presentation as high as soluble peptide. Compared to soluble peptide, in vitro, expansion of OT-II T-cells was not affected by adsorption or stable conjugation to MSRs but was enhanced with reversible conjugation to MSRs. Both conjugation schemes increased peptide residence time in MSR scaffolds in vivo compared to standard bolus injections or a simple adsorption method. When MSR scaffolds loaded with GM-CSF and CpG-ODN were injected subcutaneously, recruited dendritic cells could present antigen in situ with the stable conjugation increasing presentation capacity. Overall, this simple conjugation approach could serve as a versatile platform to efficiently incorporate peptide antigens in MSR vaccines and potentiate cellular responses.


Subject(s)
Antigens/chemistry , Dendritic Cells/immunology , Nanotubes/chemistry , Peptides/chemistry , Silicon Dioxide/chemistry , Tissue Scaffolds/chemistry , Animals , Antigens/immunology , Cells, Cultured , Dendritic Cells/chemistry , Disulfides/chemistry , Female , Immunity, Cellular , Mice, Inbred C57BL , Nanotubes/ultrastructure , Ovalbumin/chemistry , Ovalbumin/immunology , Oxidation-Reduction , Peptides/immunology , Porosity , Sulfides/chemistry
4.
Open AIDS J ; 11: 76-90, 2017.
Article in English | MEDLINE | ID: mdl-29290885

ABSTRACT

BACKGROUND: The BD FACSPresto™ system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries. The BD FACSPresto system was assessed for variability between laboratory, instrument/operators, cartridge lots and within-run at four sites. METHODS: Samples were collected under approved voluntary consent. EDTA-anticoagulated venous samples were tested for CD4 and %CD4 T cells using the gold-standard BD FACSCalibur™ system, and for Hb, using the Sysmex® KX-21N™ analyzer. Venous and capillary samples were tested on the BD FACSPresto system. Matched data was analyzed for bias (Deming linear regression and Bland-Altman methods), and for concordance around the clinical decision point. The coefficient of variation was estimated per site, instrument/operator, cartridge-lot and between-runs. RESULTS: For method comparison, 93% of the 720 samples were from HIV-positive and 7% from HIV-negative or normal subjects. CD4 and %CD4 T cells venous and capillary results gave slopes within 0.96-1.05 and R2 ≥0.96; Hb slopes were ≥1.00 and R2 ≥0.89. Variability across sites/operators gave %CV <5.8% for CD4 counts, <1.9% for %CD4 and <3.2% for Hb. The total %CV was <7.7% across instrument/cartridge lot. CONCLUSION: The BD FACSPresto system provides accurate, reliable, precise CD4/%CD4/Hb results compared to gold-standard methods, irrespective of venous or capillary blood sampling. The data showed good agreement between the BD FACSPresto, BD FACSCalibur and Sysmex systems.

5.
PLoS One ; 11(8): e0157939, 2016.
Article in English | MEDLINE | ID: mdl-27483008

ABSTRACT

BACKGROUND: The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA. METHODS: For accuracy, venous samples were tested using the BD FACSCalibur™ instrument with BD Tritest™ CD3/CD4/CD45 reagent, BD Trucount™ tubes, and BD Multiset™ software for AbsCD4 and %CD4, and the Sysmex™ KX-21N for Hb. Stability studies evaluated duration of staining (18-120-minute incubation), and effects of venous blood storage <6-24 hours post-draw. A normal cohort was tested for reference intervals. Precision covered multiple days, operators, and instruments. Linearity required mixing two pools of samples, to obtain evenly spaced concentrations for AbsCD4, total lymphocytes, and Hb. RESULTS: AbsCD4 and %CD4 venous/capillary (N = 189/ N = 162) accuracy results gave Deming regression slopes within 0.97-1.03 and R2 ≥0.96. For Hb, Deming regression results were R2 ≥0.94 and slope ≥0.94 for both venous and capillary samples. Stability varied within 10% 2 hours after staining and for venous blood stored less than 24 hours. Reference intervals results showed that gender-but not age-differences were statistically significant (p<0.05). Precision results had <3.5% coefficient of variation for AbsCD4, %CD4, and Hb, except for low AbsCD4 samples (<6.8%). Linearity was 42-4,897 cells/µL for AbsCD4, 182-11,704 cells/µL for total lymphocytes, and 2-24 g/dL for Hb. CONCLUSIONS: The BD FACSPresto system provides accurate, precise clinical results for capillary or venous blood samples and is suitable for near-patient CD4 testing. TRIAL REGISTRATION: ClinicalTrials.gov NCT02396355.


Subject(s)
CD4 Lymphocyte Count/methods , HIV Infections/blood , Adolescent , Adult , Aged , CD4-Positive T-Lymphocytes/immunology , Child , Child, Preschool , Female , Flow Cytometry/methods , HIV Infections/immunology , Humans , Kenya/epidemiology , Male , Middle Aged , Sensitivity and Specificity , Young Adult
6.
Biomaterials ; 83: 249-56, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26784009

ABSTRACT

Biomaterial scaffold based vaccines show significant potential in generating potent antigen-specific immunity. However, the role of the scaffold surface chemistry in initiating and modulating the immune response is not well understood. In this study, a mesoporous silica micro-rod (MSR) scaffold was modified with PEG, PEG-RGD and PEG-RDG groups. PEG modification significantly enhanced BMDC activation marker up-regulation and IL-1ß production in vitro, and innate immune cell infiltration in vivo. PEG-RGD MSRs and PEG-RDG MSRs displayed decreased inflammation compared to PEG MSRs, and the effect was not RGD specific. Finally, the Nlrp3 inflammasome was found to be necessary for MSR stimulated IL-1ß production in vitro and played a key role in regulating immune cell infiltration in vivo. These findings suggest that simply modulating the surface chemistry of a scaffold can regulate its immune cell infiltration profile and have implications for the design and development of new material based vaccines.


Subject(s)
Dendritic Cells/cytology , Dendritic Cells/metabolism , Silicon Dioxide/chemistry , Tissue Scaffolds/chemistry , Animals , Bone Marrow Cells/cytology , Carrier Proteins/metabolism , Cytokines/metabolism , Female , Inflammasomes/metabolism , Mice, Inbred C57BL , NLR Family, Pyrin Domain-Containing 3 Protein , Porosity , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...