Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 22(18)2022 Sep 06.
Article in English | MEDLINE | ID: mdl-36146079

ABSTRACT

Osseointegration implant has attracted significant attention as an alternative treatment for transfemoral amputees. It has been shown to improve patients' sitting and walking comfort and control of the artificial limb, compared to the conventional socket device. However, the patients treated with osseointegration implants require a long rehabilitation period to establish sufficient femur-implant connection, allowing the full body weight on the prosthesis stem. Hence, a robust assessment method on the osseointegration process is essential to shorten the rehabilitation period and identify the degree of osseointegration prior to the connection of an artificial limb. This paper investigates the capability of a vibration-related index (E-index) on detecting the degree of simulated osseointegration process with three lengths of the residual femur (152, 190 and 228 mm). The adhesive epoxy with a setting time of 5 min was applied at the femur-implant interface to represent the stiffness change during the osseointegration process. The cross-spectrum and colormap of the normalised magnitude demonstrated significant changes during the cure time, showing that application of these plots could improve the accuracy of the currently available diagnostic techniques. Furthermore, the E-index exhibited a clear trend with a noticeable average increase of 53% against the cure time for all three residual length conditions. These findings highlight that the E-index can be employed as a quantitative justification to assess the degree of osseointegration process without selecting and tracing the resonant frequency based on the geometry of the residual femur.


Subject(s)
Amputees , Artificial Limbs , Amputees/rehabilitation , Femur/surgery , Humans , Osseointegration , Prosthesis Implantation/methods , Vibration
2.
Sensors (Basel) ; 22(4)2022 Feb 21.
Article in English | MEDLINE | ID: mdl-35214590

ABSTRACT

Osseointegrated prostheses are widely used following transfemoral amputation. However, this technique requires sufficient implant stability before and during the rehabilitation period to mitigate the risk of implant breakage and loosening. Hence, reliable assessment methods for the osseointegration process are essential to ensure initial and long-term implant stability. This paper researches the feasibility of a vibration analysis technique for the osseointegration (OI) process by investigating the change in the dynamic response of the residual femur with a novel implant design during a simulated OI process. The paper also proposes a concept of an energy index (the E-index), which is formulated based on the normalized magnitude. To illustrate the potential of the E-index, this paper reports on changes in the vibrational behaviors of a 133 mm long amputated artificial femur model and implant system, with epoxy adhesives applied at the interface to simulate the OI process. The results show a significant variation in the magnitude of the colormap against curing time. The study also shows that the E-index was sensitive to the interface stiffness change, especially during the early curing process. These findings highlight the feasibility of using the vibration analysis technique and the E-index to quantitatively monitor the osseointegration process for future improvement on the efficiency of human health monitoring and patient rehabilitation.


Subject(s)
Amputees , Artificial Limbs , Amputation, Surgical , Amputees/rehabilitation , Humans , Osseointegration , Vibration
SELECTION OF CITATIONS