Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
Add more filters










Publication year range
1.
Proc Natl Acad Sci U S A ; 121(22): e2404007121, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38768347

ABSTRACT

Sensations of heat and touch produced by receptors in the skin are of essential importance for perceptions of the physical environment, with a particularly powerful role in interpersonal interactions. Advances in technologies for replicating these sensations in a programmable manner have the potential not only to enhance virtual/augmented reality environments but they also hold promise in medical applications for individuals with amputations or impaired sensory function. Engineering challenges are in achieving interfaces with precise spatial resolution, power-efficient operation, wide dynamic range, and fast temporal responses in both thermal and in physical modulation, with forms that can extend over large regions of the body. This paper introduces a wireless, skin-compatible interface for thermo-haptic modulation designed to address some of these challenges, with the ability to deliver programmable patterns of enhanced vibrational displacement and high-speed thermal stimulation. Experimental and computational investigations quantify the thermal and mechanical efficiency of a vertically stacked design layout in the thermo-haptic stimulators that also supports real-time, closed-loop control mechanisms. The platform is effective in conveying thermal and physical information through the skin, as demonstrated in the control of robotic prosthetics and in interactions with pressure/temperature-sensitive touch displays.


Subject(s)
Touch , Virtual Reality , Wireless Technology , Humans , Wireless Technology/instrumentation , Touch/physiology , Skin , Robotics/instrumentation , Robotics/methods
2.
Sci Adv ; 10(16): eadj0268, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38640247

ABSTRACT

Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.


Subject(s)
Absorbable Implants , Transducers , Animals , Wireless Technology , Hydrogen-Ion Concentration , Biomarkers
3.
Science ; 383(6687): 1096-1103, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38452063

ABSTRACT

Monitoring homeostasis is an essential aspect of obtaining pathophysiological insights for treating patients. Accurate, timely assessments of homeostatic dysregulation in deep tissues typically require expensive imaging techniques or invasive biopsies. We introduce a bioresorbable shape-adaptive materials structure that enables real-time monitoring of deep-tissue homeostasis using conventional ultrasound instruments. Collections of small bioresorbable metal disks distributed within thin, pH-responsive hydrogels, deployed by surgical implantation or syringe injection, allow ultrasound-based measurements of spatiotemporal changes in pH for early assessments of anastomotic leaks after gastrointestinal surgeries, and their bioresorption after a recovery period eliminates the need for surgical extraction. Demonstrations in small and large animal models illustrate capabilities in monitoring leakage from the small intestine, the stomach, and the pancreas.


Subject(s)
Absorbable Implants , Anastomotic Leak , Gastrointestinal Tract , Ultrasonics , Animals , Humans , Homeostasis , Stomach , Gastrointestinal Tract/surgery , Anastomotic Leak/diagnostic imaging , Models, Animal
4.
PNAS Nexus ; 3(3): pgae110, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38516273

ABSTRACT

Recent advances in passive flying systems inspired by wind-dispersed seeds contribute to increasing interest in their use for remote sensing applications across large spatial domains in the Lagrangian frame of reference. These concepts create possibilities for developing and studying structures with performance characteristics and operating mechanisms that lie beyond those found in nature. Here, we demonstrate a hybrid flier system, fabricated through a process of controlled buckling, to yield unusual geometries optimized for flight. Specifically, these constructs simultaneously exploit distinct fluid phenomena, including separated vortex rings from features that resemble those of dandelion seeds and the leading-edge vortices derived from behaviors of maple seeds. Advanced experimental measurements and computational simulations of the aerodynamics and induced flow physics of these hybrid fliers establish a concise, scalable analytical framework for understanding their flight mechanisms. Demonstrations with functional payloads in various forms, including bioresorbable, colorimetric, gas-sensing, and light-emitting platforms, illustrate examples with diverse capabilities in sensing and tracking.

5.
Neuron ; 112(11): 1764-1777.e5, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38537641

ABSTRACT

Comprehensive, continuous quantitative monitoring of intricately orchestrated physiological processes and behavioral states in living organisms can yield essential data for elucidating the function of neural circuits under healthy and diseased conditions, for defining the effects of potential drugs and treatments, and for tracking disease progression and recovery. Here, we report a wireless, battery-free implantable device and a set of associated algorithms that enable continuous, multiparametric physio-behavioral monitoring in freely behaving small animals and interacting groups. Through advanced analytics approaches applied to mechano-acoustic signals of diverse body processes, the device yields heart rate, respiratory rate, physical activity, temperature, and behavioral states. Demonstrations in pharmacological, locomotor, and acute and social stress tests and in optogenetic studies offer unique insights into the coordination of physio-behavioral characteristics associated with healthy and perturbed states. This technology has broad utility in neuroscience, physiology, behavior, and other areas that rely on studies of freely moving, small animal models.


Subject(s)
Behavior, Animal , Optogenetics , Wireless Technology , Animals , Behavior, Animal/physiology , Optogenetics/methods , Mice , Heart Rate/physiology , Male , Prostheses and Implants , Respiratory Rate/physiology , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Algorithms
6.
Adv Healthc Mater ; 13(5): e2302797, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37983897

ABSTRACT

Chronic wounds represent a major health risk for diabetic patients. Regeneration of such wounds requires regular medical treatments over periods that can extend for several months or more. Schemes for monitoring the healing process can provide important feedback to the patient and caregiver. Although qualitative indicators such as malodor or fever can provide some indirect information, quantitative measurements of the wound bed have the potential to yield important insights. The work presented here introduces materials and engineering designs for a wireless system that captures spatio-temporal temperature and thermal transport information across the wound continuously throughout the healing process. Systematic experimental and computational studies establish the materials aspects and basic capabilities of this technology. In vivo studies reveal that both the temperature and the changes in this quantity offer information on wound status, with indications of initial exothermic reactions and mechanisms of scar tissue formation. Bioresorbable materials serve as the foundations for versions of this device that create possibilities for monitoring on and within the wound site, in a way that bypasses the risks of physical removal.


Subject(s)
Cicatrix , Wound Healing , Humans , Temperature , Equipment Design
7.
Nat Biomed Eng ; 7(10): 1252-1269, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37106153

ABSTRACT

Fully implantable wireless systems for the recording and modulation of neural circuits that do not require physical tethers or batteries allow for studies that demand the use of unconstrained and freely behaving animals in isolation or in social groups. Moreover, feedback-control algorithms that can be executed within such devices without the need for remote computing eliminate virtual tethers and any associated latencies. Here we report a wireless and battery-less technology of this type, implanted subdermally along the back of freely moving small animals, for the autonomous recording of electroencephalograms, electromyograms and body temperature, and for closed-loop neuromodulation via optogenetics and pharmacology. The device incorporates a system-on-a-chip with Bluetooth Low Energy for data transmission and a compressed deep-learning module for autonomous operation, that offers neurorecording capabilities matching those of gold-standard wired systems. We also show the use of the implant in studies of sleep-wake regulation and for the programmable closed-loop pharmacological suppression of epileptic seizures via feedback from electroencephalography. The technology can support a broader range of applications in neuroscience and in biomedical research with small animals.

8.
Proc Natl Acad Sci U S A ; 120(6): e2217828120, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36716364

ABSTRACT

Thermal sensations contribute to our ability to perceive and explore the physical world. Reproducing these sensations in a spatiotemporally programmable manner through wireless computer control could enhance virtual experiences beyond those supported by video, audio and, increasingly, haptic inputs. Flexible, lightweight and thin devices that deliver patterns of thermal stimulation across large areas of the skin at any location of the body are of great interest in this context. Applications range from those in gaming and remote socioemotional communications, to medical therapies and physical rehabilitation. Here, we present a set of ideas that form the foundations of a skin-integrated technology for power-efficient generation of thermal sensations across the skin, with real-time, closed-loop control. The systems exploit passive cooling mechanisms, actively switchable thermal barrier interfaces, thin resistive heaters and flexible electronics configured in a pixelated layout with wireless interfaces to portable devices, the internet and cloud data infrastructure. Systematic experimental studies and simulation results explore the essential mechanisms and guide the selection of optimized choices in design. Demonstration examples with human subjects feature active thermoregulation, virtual social interactions, and sensory expansion.


Subject(s)
Skin , Virtual Reality , Humans , Electronics , Thermosensing , Communication
9.
Sci Robot ; 8(74): eadd1053, 2023 01 25.
Article in English | MEDLINE | ID: mdl-36652505

ABSTRACT

Bioengineering approaches that combine living cellular components with three-dimensional scaffolds to generate motion can be used to develop a new generation of miniature robots. Integrating on-board electronics and remote control in these biological machines will enable various applications across engineering, biology, and medicine. Here, we present hybrid bioelectronic robots equipped with battery-free and microinorganic light-emitting diodes for wireless control and real-time communication. Centimeter-scale walking robots were computationally designed and optimized to host on-board optoelectronics with independent stimulation of multiple optogenetic skeletal muscles, achieving remote command of walking, turning, plowing, and transport functions both at individual and collective levels. This work paves the way toward a class of biohybrid machines able to combine biological actuation and sensing with on-board computing.


Subject(s)
Robotics , Robotics/methods , Muscle, Skeletal/physiology , Electronics , Walking
10.
Sci Adv ; 8(51): eade3201, 2022 12 23.
Article in English | MEDLINE | ID: mdl-36563148

ABSTRACT

Recently reported winged microelectronic systems offer passive flight mechanisms as a dispersal strategy for purposes in environmental monitoring, population surveillance, pathogen tracking, and other applications. Initial studies indicate potential for technologies of this type, but advances in structural and responsive materials and in aerodynamically optimized geometries are necessary to improve the functionality and expand the modes of operation. Here, we introduce environmentally degradable materials as the basis of 3D fliers that allow remote, colorimetric assessments of multiple environmental parameters-pH, heavy metal concentrations, and ultraviolet exposure, along with humidity levels and temperature. Experimental and theoretical investigations of the aerodynamics of these systems reveal design considerations that include not only the geometries of the structures but also their mass distributions across a range of bioinspired designs. Preliminary field studies that rely on drones for deployment and for remote colorimetric analysis by machine learning interpretation of digital images illustrate scenarios for practical use.

11.
Micromachines (Basel) ; 13(11)2022 Oct 29.
Article in English | MEDLINE | ID: mdl-36363874

ABSTRACT

The poor hydrophilicity of polyimide (PI) films limits their applications in flexible electronics, such as in wearable and implantable bio-MEMS devices. In this paper, an atmospheric pressure Ar/H2O microplasma jet (µAPPJ) with a nozzle diameter of 100 µm was utilized to site-selectively tune the surface hydrophilicity of a PI film. The electrical and optical characteristics of the µAPPJ were firstly investigated, and the results showed that multi-spikes occurred during the plasma discharge and that diverse reactive species, such as O atoms and OH radicals, were generated in the plasma plume. The physical and chemical properties of pristine and microplasma-modified PI surfaces were characterized by the water contact angle (WCA), atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The wettability of the PI surface was significantly enhanced after microplasma modification, and the WCA could be adjusted by varying the applied voltage, water vapor content, plasma treatment time and storage time. The AFM images indicated that the surface roughness increased after the plasma treatment, which partially contributed to an improvement in the surface hydrophilicity. The XPS results showed a reduction in the C content and an increase in the O content, and abundant hydrophilic polar oxygen-containing functional groups were also grafted onto the PI film surface. Finally, the interaction mechanism between the PI molecular chains and the microplasma is discussed. The breaking of C-N and C-O bonds and the grafting of OH radicals were the key pathways to dominate the reaction process.

12.
Nat Commun ; 13(1): 5576, 2022 Sep 23.
Article in English | MEDLINE | ID: mdl-36151092

ABSTRACT

Low modulus materials that can shape-morph into different three-dimensional (3D) configurations in response to external stimuli have wide-ranging applications in flexible/stretchable electronics, surgical instruments, soft machines and soft robotics. This paper reports a shape-programmable system that exploits liquid metal microfluidic networks embedded in an elastomer matrix, with electromagnetic forms of actuation, to achieve a unique set of properties. Specifically, this materials structure is capable of fast, continuous morphing into a diverse set of continuous, complex 3D surfaces starting from a two-dimensional (2D) planar configuration, with fully reversible operation. Computational, multi-physics modeling methods and advanced 3D imaging techniques enable rapid, real-time transformations between target shapes. The liquid-solid phase transition of the liquid metal allows for shape fixation and reprogramming on demand. An unusual vibration insensitive, dynamic 3D display screen serves as an application example of this type of morphable surface.

13.
Adv Mater ; 34(16): e2108391, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35233865

ABSTRACT

Recent progress in soft material chemistry and enabling methods of 3D and 4D fabrication-emerging programmable material designs and associated assembly methods for the construction of complex functional structures-is highlighted. The underlying advances in this science allow the creation of soft material architectures with properties and shapes that programmably vary with time. The ability to control composition from the molecular to the macroscale is highlighted-most notably through examples that focus on biomimetic and biologically compliant soft materials. Such advances, when coupled with the ability to program material structure and properties across multiple scales via microfabrication, 3D printing, or other assembly techniques, give rise to responsive (4D) architectures. The challenges and prospects for progress in this emerging field in terms of its capacities for integrating chemistry, form, and function are described in the context of exemplary soft material systems demonstrating important but heretofore difficult-to-realize biomimetic and biologically compliant behaviors.


Subject(s)
Biomimetics , Printing, Three-Dimensional
14.
Small ; 18(17): e2107879, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35307953

ABSTRACT

Island-bridge architectures represent a widely used structural design in stretchable inorganic electronics, where deformable interconnects that form the bridge provide system stretchability, and functional components that reside on the islands undergo negligible deformations. These device systems usually experience a common strain concentration phenomenon, i.e., "island effect", because of the modulus mismatch between the soft elastomer substrate and its on-top rigid components. Such an island effect can significantly raise the surrounding local strain, therefore increasing the risk of material failure for the interconnects in the vicinity of the islands. In this work, a systematic study of such an island effect through combined theoretical analysis, numerical simulations and experimental measurements is presented. To relieve the island effect, a buffer layer strategy is proposed as a generic route to enhanced stretchabilities of deformable interconnects. Both experimental and numerical results illustrate the applicability of this strategy to 2D serpentine and 3D helical interconnects, as evidenced by the increased stretchabilities (e.g., by 1.5 times with a simple buffer layer, and 2 times with a ring buffer layer, both for serpentine interconnects). The application of the patterned buffer layer strategy in a stretchable light emitting diodes system suggests promising potentials for uses in other functional device systems.

15.
J Reconstr Microsurg ; 38(2): 96-105, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34404105

ABSTRACT

BACKGROUND: Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are highly sensitive for detecting malperfusion. However, the clinical utility and user experience are limited by the wired connection between the sensor and bedside console. This wire leads to instability of the flap-sensor interface and may cause false alarms. METHODS: We present a novel wearable wireless NIRS sensor for continuous fasciocutaneous free flap monitoring. This waterproof silicone-encapsulated Bluetooth-enabled device contains two light-emitting diodes and two photodetectors in addition to a battery sufficient for 5 days of uninterrupted function. This novel device was compared with a ViOptix T.Ox monitor in a porcine rectus abdominus myocutaneous flap model of arterial and venous occlusions. RESULTS: Devices were tested in four flaps using three animals. Both devices produced very similar tissue oxygen saturation (StO2) tracings throughout the vascular clamping events, with obvious and parallel changes occurring on arterial clamping, arterial release, venous clamping, and venous release. Small interdevice variations in absolute StO2 value readings and magnitude of change were observed. The normalized cross-correlation at zero lag describing correspondence between the novel NIRS and T.Ox devices was >0.99 in each trial. CONCLUSION: The wireless NIRS flap monitor is capable of detecting StO2 changes resultant from arterial vascular occlusive events. In this porcine flap model, the functionality of this novel sensor closely mirrored that of the T.Ox wired platform. This device is waterproof, highly adhesive, skin conforming, and has sufficient battery life to function for 5 days. Clinical testing is necessary to determine if this wireless functionality translates into fewer false-positive alarms and a better user experience.


Subject(s)
Free Tissue Flaps , Myocutaneous Flap , Animals , Monitoring, Physiologic , Oxygen , Spectroscopy, Near-Infrared , Swine , Veins
16.
Adv Sci (Weinh) ; 9(2): e2103331, 2022 01.
Article in English | MEDLINE | ID: mdl-34747140

ABSTRACT

Nutrients play critical roles in maintaining core physiological functions and in preventing diseases. Technologies for delivering these nutrients and for monitoring their concentrations can help to ensure proper nutritional balance. Eccrine sweat is a potentially attractive class of biofluid for monitoring purposes due to the ability to capture sweat easily and noninvasively from nearly any region of the body using skin-integrated microfluidic technologies. Here, a miniaturized system of this type is presented that allows simple, rapid colorimetric assessments of the concentrations of multiple essential nutrients in sweat, simultaneously and without any supporting electronics - vitamin C, calcium, zinc, and iron. A transdermal patch integrated directly with the microfluidics supports passive, sustained delivery of these species to the body throughout a period of wear. Comparisons of measurement results to those from traditional lab analysis methods demonstrate the accuracy and reliability of this platform. On-body tests with human subjects reveal correlations between the time dynamics of concentrations of these nutrients in sweat and those of the corresponding concentrations in blood. Studies conducted before and after consuming certain foods and beverages highlight practical capabilities in monitoring nutritional balance, with strong potential to serve as a basis for guiding personalized dietary choices.


Subject(s)
Microfluidic Analytical Techniques/methods , Microfluidics/methods , Skin/metabolism , Sweat/chemistry , Sweat/metabolism , Vitamins/administration & dosage , Adult , Biosensing Techniques/methods , Colorimetry , Female , Humans , Male , Nutrients/administration & dosage , Transdermal Patch , Vitamins/metabolism , Young Adult
17.
Sci Adv ; 7(43): eabj3686, 2021 Oct 22.
Article in English | MEDLINE | ID: mdl-34669471

ABSTRACT

Microfluidic technologies have wide-ranging applications in chemical analysis systems, drug delivery platforms, and artificial vascular networks. This latter area is particularly relevant to 3D cell cultures, engineered tissues, and artificial organs, where volumetric capabilities in fluid distribution are essential. Existing schemes for fabricating 3D microfluidic structures are constrained in realizing desired layout designs, producing physiologically relevant microvascular structures, and/or integrating active electronic/optoelectronic/microelectromechanical components for sensing and actuation. This paper presents a guided assembly approach that bypasses these limitations to yield complex 3D microvascular structures from 2D precursors that exploit the full sophistication of 2D fabrication methods. The capabilities extend to feature sizes <5 µm, in extended arrays and with various embedded sensors and actuators, across wide ranges of overall dimensions, in a parallel, high-throughput process. Examples include 3D microvascular networks with sophisticated layouts, deterministically designed and constructed to expand the geometries and operating features of artificial vascular networks.

18.
Nature ; 597(7877): 503-510, 2021 09.
Article in English | MEDLINE | ID: mdl-34552257

ABSTRACT

Large, distributed collections of miniaturized, wireless electronic devices1,2 may form the basis of future systems for environmental monitoring3, population surveillance4, disease management5 and other applications that demand coverage over expansive spatial scales. Aerial schemes to distribute the components for such networks are required, and-inspired by wind-dispersed seeds6-we examined passive structures designed for controlled, unpowered flight across natural environments or city settings. Techniques in mechanically guided assembly of three-dimensional (3D) mesostructures7-9 provide access to miniature, 3D fliers optimized for such purposes, in processes that align with the most sophisticated production techniques for electronic, optoelectronic, microfluidic and microelectromechanical technologies. Here we demonstrate a range of 3D macro-, meso- and microscale fliers produced in this manner, including those that incorporate active electronic and colorimetric payloads. Analytical, computational and experimental studies of the aerodynamics of high-performance structures of this type establish a set of fundamental considerations in bio-inspired design, with a focus on 3D fliers that exhibit controlled rotational kinematics and low terminal velocities. An approach that represents these complex 3D structures as discrete numbers of blades captures the essential physics in simple, analytical scaling forms, validated by computational and experimental results. Battery-free, wireless devices and colorimetric sensors for environmental measurements provide simple examples of a wide spectrum of applications of these unusual concepts.


Subject(s)
Biomimetics , Electrical Equipment and Supplies , Miniaturization/instrumentation , Seeds , Wind , Wireless Technology/instrumentation , Colorimetry , Environmental Monitoring/instrumentation , Environmental Monitoring/methods , Mechanical Phenomena , Microfluidics , Population Surveillance/methods , Rotation
19.
Nat Mater ; 20(11): 1559-1570, 2021 11.
Article in English | MEDLINE | ID: mdl-34326506

ABSTRACT

Flexible electronic/optoelectronic systems that can intimately integrate onto the surfaces of vital organ systems have the potential to offer revolutionary diagnostic and therapeutic capabilities relevant to a wide spectrum of diseases and disorders. The critical interfaces between such technologies and living tissues must provide soft mechanical coupling and efficient optical/electrical/chemical exchange. Here, we introduce a functional adhesive bioelectronic-tissue interface material, in the forms of mechanically compliant, electrically conductive, and optically transparent encapsulating coatings, interfacial layers or supporting matrices. These materials strongly bond both to the surfaces of the devices and to those of different internal organs, with stable adhesion for several days to months, in chemistries that can be tailored to bioresorb at controlled rates. Experimental demonstrations in live animal models include device applications that range from battery-free optoelectronic systems for deep-brain optogenetics and subdermal phototherapy to wireless millimetre-scale pacemakers and flexible multielectrode epicardial arrays. These advances have immediate applicability across nearly all types of bioelectronic/optoelectronic system currently used in animal model studies, and they also have the potential for future treatment of life-threatening diseases and disorders in humans.


Subject(s)
Absorbable Implants , Adhesives , Animals , Electric Conductivity , Electronics
20.
Nat Biomed Eng ; 5(7): 759-771, 2021 07.
Article in English | MEDLINE | ID: mdl-34045731

ABSTRACT

Evaluating the biomechanics of soft tissues at depths well below their surface, and at high precision and in real time, would open up diagnostic opportunities. Here, we report the development and application of miniaturized electromagnetic devices, each integrating a vibratory actuator and a soft strain-sensing sheet, for dynamically measuring the Young's modulus of skin and of other soft tissues at depths of approximately 1-8 mm, depending on the particular design of the sensor. We experimentally and computationally established the operational principles of the devices and evaluated their performance with a range of synthetic and biological materials and with human skin in healthy volunteers. Arrays of devices can be used to spatially map elastic moduli and to profile the modulus depth-wise. As an example of practical medical utility, we show that the devices can be used to accurately locate lesions associated with psoriasis. Compact electronic devices for the rapid and precise mechanical characterization of living tissues could be used to monitor and diagnose a range of health disorders.


Subject(s)
Electrochemical Techniques/methods , Skin/chemistry , Adult , Aged , Animals , Biomechanical Phenomena , Elastic Modulus , Electrochemical Techniques/instrumentation , Humans , Hydrogels/chemistry , Middle Aged , Miniaturization , Skin/metabolism , Swine , Vibration , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...