Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Ophthalmol ; 15: 1647-1657, 2021.
Article in English | MEDLINE | ID: mdl-33907378

ABSTRACT

PURPOSE: This study assessed effectiveness and safety of the novel Clareon intraocular lens (IOL; model SY60CL; Alcon Vision LLC). PATIENTS AND METHODS: This was a prospective, single-arm, unmasked clinical trial at 16 investigative clinical sites in the United States. Included were adults ≥22 years who required cataract extraction by phacoemulsification. Following phacoemulsification, 350 subjects received SY60CL IOL unilaterally; 342 completed the study. Monocular best corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) were evaluated. The primary effectiveness endpoint was the percentage of subjects with CDVA ≤0.3 logMAR at month 12. Safety was assessed by monitoring adverse events (AEs). Visual acuity and safety outcomes were compared with historical safety and performance endpoint (SPE) rates. RESULTS: At 12 months post-implantation, 99.7% of subjects receiving the SY60CL IOL achieved monocular CDVA ≤0.3 logMAR (primary effectiveness endpoint; 1-sided 95% upper confidence limit >SPE rate); 99.7% and 86.8% of subjects achieved monocular CDVA of ≤0.34 (20/40 Snellen or better) and ≤0.04 logMAR (20/20 Snellen or better), respectively. At 12 months, >95% of subjects achieved mean monocular UDVA ≤0.3 logMAR; 97.1% and 57.6% of subjects achieved monocular CDVA of ≤0.34 and ≤0.04 logMAR, respectively. Mean monocular CDVA and UDVA were -0.05 and 0.04 logMAR, respectively. AEs were within SPE limits. The most common nonserious ocular AE was posterior capsule opacification (5.4%). Serious AEs were <1%, and no serious ocular AEs were assessed as related to the device. There were no observations for IOL glistenings at 12 months. CONCLUSION: Results of this study supported effectiveness and safety of the SY60CL IOL. Visual acuity outcomes with the SY60CL IOL exceeded the SPE rates for monocular CDVA and AEs were within the limit of historic SPE rates. (Model number SY60WF is the Clareon lens approved by the FDA.).

2.
Ophthalmology ; 126(6): 811-821, 2019 06.
Article in English | MEDLINE | ID: mdl-30880108

ABSTRACT

PURPOSE: Evaluate the safety and effectiveness of an ab interno implanted (iStent inject) Trabecular Micro-Bypass System (Glaukos Corporation, San Clemente, CA) in combination with cataract surgery in subjects with mild to moderate primary open-angle glaucoma (POAG). DESIGN: Prospective, randomized, single-masked, concurrently controlled, multicenter clinical trial. PARTICIPANTS: Eyes with mild to moderate POAG and preoperative intraocular pressure (IOP) ≤24 mmHg on 1 to 3 medications, unmedicated diurnal IOP (DIOP) 21 to 36 mmHg, and cataract requiring surgery. METHODS: After uncomplicated cataract surgery, eyes were randomized 3:1 intraoperatively to ab interno implantation of iStent inject (Model G2-M-IS; treatment group, n = 387) or no stent implantation (control group, n = 118). Subjects were followed through 2 years postoperatively. Annual washout of ocular hypotensive medication was performed. MAIN OUTCOME MEASURES: Effectiveness end points were ≥20% reduction from baseline in month 24 unmedicated DIOP and change in unmedicated month 24 DIOP from baseline. Safety measures included best spectacle-corrected visual acuity (BSCVA), slit-lamp and fundus examinations, gonioscopy, pachymetry, specular microscopy, visual fields, complications, and adverse events. RESULTS: The groups were well balanced preoperatively, including medicated IOP (17.5 mmHg in both groups) and unmedicated DIOP (24.8±3.3 mmHg vs. 24.5±3.1 mmHg in the treatment and control groups, respectively, P = 0.33). At 24 months, 75.8% of treatment eyes versus 61.9% of control eyes experienced ≥20% reduction from baseline in unmedicated DIOP (P = 0.005), and mean reduction in unmedicated DIOP from baseline was greater in treatment eyes (7.0±4.0 mmHg) than in control eyes (5.4±3.7 mmHg; P < 0.001). Of the responders, 84% of treatment eyes and 67% of control eyes were not receiving ocular hypotensive medication at 23 months. Furthermore, 63.2% of treatment eyes versus 50.0% of control eyes had month 24 medication-free DIOP ≤18 mmHg (difference 13.2%; 95% confidence interval, 2.9-23.4). The overall safety profile of the treatment group was favorable and similar to that in the control group throughout the 2-year follow-up. CONCLUSIONS: Clinically and statistically greater reductions in IOP without medication were achieved after iStent inject implantation with cataract surgery versus cataract surgery alone, with excellent safety through 2 years.


Subject(s)
Cataract/complications , Glaucoma Drainage Implants , Glaucoma, Open-Angle/surgery , Phacoemulsification , Trabecular Meshwork/surgery , Aged , Antihypertensive Agents/administration & dosage , Female , Follow-Up Studies , Glaucoma, Open-Angle/physiopathology , Gonioscopy , Humans , Intraocular Pressure/physiology , Lens Implantation, Intraocular , Male , Middle Aged , Prospective Studies , Single-Blind Method , Stents , Tonometry, Ocular , Visual Acuity/physiology , Visual Fields/physiology
3.
Cornea ; 38(2): 177-182, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30615600

ABSTRACT

PURPOSE: Descemet stripping endothelial keratoplasty (DSEK), currently the most common procedure for managing corneal endothelial dysfunction, may be repeated following DSEK failure from a variety of causes. This multicenter study reports the risk factors and outcomes of repeat DSEK. METHODS: This was an institutional review board-approved multicenter retrospective chart review of patients who underwent repeat DSEK. Twelve surgeons from 5 Midwest academic centers and 3 private practice groups participated. The Eversight Eye Bank provided clinical indication and donor graft data. We also assessed the role of the learning curve by comparing cohorts from the first and second 5-year periods. RESULTS: A total of 121 eyes from 121 patients who underwent repeat DSEK were identified. The average age of the patients was 70 ± 12 years. The most common indication for repeat DSEK was late endothelial graft failure without rejection (58%, N = 63). Average preoperative and 12-month postoperative repeat DSEK corrected distance visual acuities were 20/694 and 20/89, respectively. Visual acuity outcomes, endothelial cell density, and cell loss did not significantly vary between the 2 cohorts. Initial graft rebubble rates for the first and second cohorts were 51% and 25%. The presence of glaucoma, prior glaucoma surgery, or a history of penetrating (full thickness) keratoplasty did not significantly affect visual outcomes. The median, mean, and range of intraocular pressures before repeat DSEK were 15.0, 15.7, and 6 to 37 mm Hg, respectively. Patients with higher intraocular pressures before repeat DSEK had improved postoperative corrected distance visual acuities. CONCLUSIONS: Repeating DSEK improves vision following failed or decompensated DSEK surgery. Higher preoperative repeat DSEK IOPs were associated with improved visual outcomes, and initial graft rebubble rates, which decreased over time, were likely due to surgeon experience.


Subject(s)
Corneal Diseases/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Aged , Aged, 80 and over , Corneal Diseases/physiopathology , Corneal Endothelial Cell Loss/etiology , Female , Graft Rejection/pathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Reoperation , Retrospective Studies , Risk Factors , Visual Acuity/physiology
5.
Transl Vis Sci Technol ; 4(4): 7, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26290778

ABSTRACT

PURPOSE: To evaluate the intensity and stability of the red reflex produced by ophthalmic surgical microscopes with nearly-collimated versus focused illumination systems and to assess surgeon preference in a simulated surgical setting. METHODS: This two-part evaluation consisted of postproduction surgical video analysis of red reflex intensity and a microscope use and preference survey completed by 13 experienced cataract surgeons. Survey responses were based on bench testing and experience in a simulated surgical setting. A microscope with nearly-collimated beam illumination and two focused beam microscopes were assessed. RESULTS: Red reflex intensity and stability were greater with the nearly-collimated microscope illumination system. In the bench testing survey, surgeons reported that the red reflex was maintained over significantly greater distances away from pupillary center, and depth of focus was numerically greater with nearly-collimated illumination relative to focused illumination. Most participating surgeons (≥64%) reported a preference for the microscope with nearly-collimated illumination with regard to red reflex stability, depth of focus, visualization, surgical working distance, and perceived patient comfort. CONCLUSIONS: The microscope with nearly-collimated illumination produced a more intense and significantly more stable red reflex and was preferred overall by more surgeons. TRANSLATIONAL RELEVANCE: This is the first report of an attempt to quantify red reflex intensity and stability and to evaluate surgically-relevant parameters between microscope systems. The data and methods presented here may provide a basis for future studies attempting to quantify differences between surgical microscopes that may affect surgeon preference and microscope use in ophthalmic surgery.

SELECTION OF CITATIONS