Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Phys Med Biol ; 68(6)2023 03 31.
Article in English | MEDLINE | ID: mdl-36584393

ABSTRACT

This Roadmap paper covers the field of precision preclinical x-ray radiation studies in animal models. It is mostly focused on models for cancer and normal tissue response to radiation, but also discusses other disease models. The recent technological evolution in imaging, irradiation, dosimetry and monitoring that have empowered these kinds of studies is discussed, and many developments in the near future are outlined. Finally, clinical translation and reverse translation are discussed.


Subject(s)
Radiometry , Animals , X-Rays , Radiometry/methods , Radiography , Models, Animal , Phantoms, Imaging
2.
Reprod Toxicol ; 105: 44-52, 2021 10.
Article in English | MEDLINE | ID: mdl-34407461

ABSTRACT

Pigs have become an important model for agricultural and biomedical purposes. The advent of genomic engineering tools, such as the CRISPR/Cas9 system, has facilitated the production of livestock models with desired modifications. However, precise site-specific modifications in pigs through the homology-directed repair (HDR) pathway remains a challenge. In mammalian embryos, the use of small molecules to inhibit non-homologous end joining (NHEJ) or to improve HDR have been tested, but little is known about their toxicity. The compound RS-1 stimulates the activity of the RAD51 protein, which plays a key role in the HDR mechanism, demonstrating enhancement of HDR events in rabbit and bovine zygotes. Thus, in this study, we evaluated the dosage and temporal effects of RS-1 on porcine embryo development and viability. Additionally, we assessed the effects of its vehicle, DMSO, during embryo in vitro culture. Transient exposure to 7.5 µM of RS-1 did not adversely affect early embryo development and was compatible with subsequent development to term. Additionally, low concentrations of its vehicle, DMSO, did not show any toxicity to in vitro produced embryos. The transient use of RS-1 at 7.5 µM during in vitro culture seems to be the best protocol of choice to reduce the potentially toxic effects of RS-1 while attempting to improve HDR in the pig. Direct injection of the CRISPR/Cas9 system, combined with strategies to increase the frequency of targeted modifications via HDR, have become an important tool to simplify and accelerate the production of genetically modified livestock models.


Subject(s)
Benzamides/pharmacology , Dimethyl Sulfoxide/pharmacology , Embryonic Development/drug effects , Rad51 Recombinase , Sulfonamides/pharmacology , Animals , Embryo Transfer , Embryo, Mammalian/drug effects , Membrane Potential, Mitochondrial/drug effects , Swine , Tissue Culture Techniques
3.
Transgenic Res ; 29(4): 395-407, 2020 08.
Article in English | MEDLINE | ID: mdl-32607872

ABSTRACT

Advances in genome editing tools have reduced barriers to the creation of animal models. Due to their anatomical and physiological similarities to humans, there has been a growing need for pig models to study human diseases, for xenotransplantation and translational research. The ability to determine the sex of genetically modified embryos, cells or fetuses is beneficial for every project involving the production of transgenic animals. This strategy can improve the time-efficiency and lower the production costs. Additionally, sex assessment is very useful for wildlife studies to understand population behavior and structure. Thus, we developed a simple and fast PCR-based protocol for sex determination in pigs by using a unique primer set to amplify either the DDX3X or DDX3Y gene. The sex was 100% correctly assigned when tail genomic DNA, Day-35 fetus and hair samples from pigs were used. For both blastocysts and oocytes (84.6% and 96.5% of efficacy, respectively) the unidentified samples were potentially due to a limitation in sample size. Our assay also worked for domestic sheep (Ovis aries), American bison (Bison bison) and European cattle (Bos taurus) samples and by in silico analysis we confirmed X-Y amplicon length polymorphisms for the DDX3 gene in 12 other mammalian species. This PCR protocol for determining sex in pig tissues and cells showed to be simple, specific, highly reproducible and less time consuming as well as an important tool for other livestock species and wildlife studies.


Subject(s)
DEAD-box RNA Helicases/genetics , Genes, X-Linked , Genes, Y-Linked , Genetic Variation , Sequence Analysis, DNA/methods , Sex Determination Analysis/methods , Animals , Bison , Cattle , Female , Male , Polymerase Chain Reaction , Sheep, Domestic , Swine
4.
Phys Med Biol ; 61(10): 3969-84, 2016 05 21.
Article in English | MEDLINE | ID: mdl-27156786

ABSTRACT

The aim of this work is to compare time-resolved (TR) and time-integrated (TI) portal dosimetry, focussing on the role of an object's position with respect to the isocenter in volumetric modulated arc therapy (VMAT). Portal dose images (PDIs) are simulated and measured for different cases: a sphere (1), a bovine bone (2) and a patient geometry (3). For the simulated case (1) and the experimental case (2), several transformations are applied at different off-axis positions. In the patient case (3), three simple plans with different isocenters are created and pleural effusion is simulated in the patient. The PDIs before and after the sphere transformations, as well as the PDIs with and without simulated pleural effusion, are compared using a TI and TR gamma analysis. In addition, the performance of the TI and TR gamma analyses for the detection of real geometric changes in patients treated with clinical plans is investigated and a correlation analysis is performed between gamma fail rates and differences in dose volume histogram (DVH) metrics. The TI gamma analysis can show large differences in gamma fail rates for the same transformation at different off-axis positions (or for different plan isocenters). The TR gamma analysis, however, shows consistent gamma fail rates. For the detection of real geometric changes in patients treated with clinical plans, the TR gamma analysis has a higher sensitivity than the TI gamma analysis. However, the specificity for the TR gamma analysis is lower than for the TI gamma analysis. Both the TI and TR gamma fail rates show no correlation with changes in DVH metrics. This work shows that TR portal dosimetry is fundamentally superior to TI portal dosimetry, because it removes the strong dependence of the gamma fail rate on the off-axis position/plan isocenter. However, for 2D TR portal dosimetry, it is still difficult to interpret gamma fail rates in terms of changes in DVH metrics for patients treated with VMAT.


Subject(s)
Patient Positioning , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Animals , Cattle , Gamma Rays , Humans , Radiometry/methods , Radiotherapy Dosage
5.
Acta Oncol ; 54(9): 1501-7, 2015.
Article in English | MEDLINE | ID: mdl-26179632

ABSTRACT

BACKGROUND: Geometric changes are frequent during the course of treatment of lung cancer patients. This may potentially result in deviations between the planned and actual delivered dose. Electronic portal imaging device (EPID)-based integrated transit planar portal dosimetry (ITPD) is a fast method for absolute in-treatment dose verification. The aim of this study was to investigate if ITPD could detect geometric changes in lung cancer patients. MATERIALS AND METHODS: A total of 460 patients treated with volumetric modulated arc therapy (VMAT) following daily cone beam computed tomography (CT)-based setup were visually inspected for geometrical changes on a daily basis. Forty-six patients were subject to changes and had a re-CT and an adaptive treatment plan. The reasons for adaptation were: change in atelectasis (n = 18), tumor regression (n = 9), change in pleural effusion (n = 8) or other causes (n = 11). The ITPDs were calculated on both the initial planning CT and the re-CT and compared with a global gamma (γ) evaluation (criteria: 3%\3mm). A treatment fraction failed when the percentage of pixels failing in the radiation fields exceeded 10%. Dose-volume histograms (DVHs) were compared between the initial plan versus the plan re-calculated on the re-CT. RESULTS: The ITPD threshold method detected 76% of the changes in atelectasis, while only 50% of the tumor regression cases and 42% of the pleural effusion cases were detected. Only 10% of the cases adapted for other reasons were detected with ITPD. The method has a 17% false-positive rate. No significant correlations were found between changes in DVH metrics and γ fail-rates. CONCLUSIONS: This study showed that most cases with geometric changes caused by atelectasis could be captured by ITPD, however for other causes ITPD is not sensitive enough to detect the clinically relevant changes and no predictive power of ITPD was found.


Subject(s)
Lung Neoplasms/radiotherapy , Radiometry/methods , Radiotherapy, Intensity-Modulated/methods , Aged , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/radiotherapy , Cone-Beam Computed Tomography , Female , Humans , Imaging, Three-Dimensional , Lung Neoplasms/diagnostic imaging , Male , Pleural Effusion, Malignant/diagnostic imaging , Pulmonary Atelectasis/diagnostic imaging , Radiotherapy, Image-Guided , Retrospective Studies , Small Cell Lung Carcinoma/diagnostic imaging , Small Cell Lung Carcinoma/radiotherapy
6.
Acta Oncol ; 54(9): 1483-9, 2015.
Article in English | MEDLINE | ID: mdl-26219958

ABSTRACT

BACKGROUND: Use of highly conformal radiotherapy in patients with head and neck carcinoma may lead to under-/overdosage of gross target volume (GTV) and organs at risk (OAR) due to changes in patients' anatomy. A method to achieve more effective radiation treatment combined with less toxicity is dose-guided radiotherapy (DGRT). The aim of this study was to evaluate discrepancies between planned and actually delivered radiation dose in head and neck patients and to identify predictive factors. METHODS: In this retrospective analysis, 20 patients with cT2-4 N0-3 M0 carcinoma originating from oropharynx, oral cavity, larynx and hypopharynx (Cohort 1), and seven patients with cT1-4 N0-3 M0 nasopharyngeal carcinoma (Cohort 2) treated with primary (chemo)radiotherapy and undergoing weekly kV-CBCT scans were included. Radiation dose was recalculated on 184 kV-CBCT images, which was quantified by D95% (GTV), Dmean (parotid and submandibular glands) and D2% (spinal cord). Predictive factors investigated for changes in these dose metrics were: gender, age, cT/N-stage, tumor grade, HPV-status, systemic therapy, body mass index at start of treatment, weight loss and volume change over the duration of the radiotherapy. RESULTS: There was no significant difference between the planned and delivered dose for GTV and OARs of Week 1 to subsequent weeks for Cohort 1. In Cohort 2, actually delivered Dmean to parotid glands was significant higher than planned dose (1.1 Gy, p = 0.002). No clinically relevant correlations between dose changes and predictive factors were found. CONCLUSION: Weekly dose calculations do not seem to improve dose delivery for patients with tumors of the oral cavity, oropharynx, larynx and hypopharynx. In patients with nasopharyngeal carcinoma, however, mid-treatment imaging may facilitate DGRT.


Subject(s)
Cone-Beam Computed Tomography , Head and Neck Neoplasms/radiotherapy , Radiotherapy Dosage , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/radiotherapy , Chemoradiotherapy , Female , Head and Neck Neoplasms/diagnostic imaging , Humans , Male , Middle Aged , Radiotherapy Planning, Computer-Assisted , Retrospective Studies , Weight Loss
7.
Phys Med Biol ; 59(20): 5973-85, 2014 Oct 21.
Article in English | MEDLINE | ID: mdl-25230002

ABSTRACT

Modern external beam radiotherapy requires detailed verification and quality assurance so that confidence can be placed on both the delivery of a single treatment fraction and on the consistency of delivery throughout the treatment course. To verify dose distributions, a comparison between prediction and measurement must be made. Comparisons between two dose distributions are commonly performed using a Gamma evaluation which is a calculation of two quantities on a pixel by pixel basis; the dose difference, and the distance to agreement. By providing acceptance criteria (e.g. 3%, 3 mm), the function will find the most appropriate match within its two degrees of freedom. For complex dynamic treatments such as IMRT or VMAT it is important to verify the dose delivery in a time dependent manner and so a gamma evaluation that includes a degree of freedom in the time domain via a third parameter, time to agreement, is presented here. A C++ (mex) based gamma function was created that could be run on either CPU and GPU computing platforms that would allow a degree of freedom in the time domain. Simple test cases were created in both 2D and 3D comprising of simple geometrical shapes with well-defined boundaries varying over time. Changes of varying magnitude in either space or time were introduced and repeated gamma analyses were performed varying the criteria. A clinical VMAT case was also included, artificial air bubbles of varying size were introduced to a patient geometry, along with shifts of varying magnitude in treatment time. For all test cases where errors in distance, dose or time were introduced, the time dependent gamma evaluation could accurately highlight the errors.The time dependent gamma function presented here allows time to be included as a degree of freedom in gamma evaluations. The function allows for 2D and 3D data sets which are varying over time to be compared using appropriate criteria without penalising minor offsets of subsequent radiation fields in time.


Subject(s)
Algorithms , Radiotherapy Planning, Computer-Assisted/methods , Gamma Rays , Radiotherapy Dosage
8.
Phys Med Biol ; 59(16): 4749-68, 2014 Aug 21.
Article in English | MEDLINE | ID: mdl-25088064

ABSTRACT

Methods to calibrate Megavoltage electronic portal imaging devices (EPIDs) for dosimetry have been previously documented for dynamic treatments such as intensity modulated radiotherapy (IMRT) using flattened beams and typically using integrated fields. While these methods verify the accumulated field shape and dose, the dose rate and differential fields remain unverified. The aim of this work is to provide an accurate calibration model for time dependent pre-treatment dose verification using amorphous silicon (a-Si) EPIDs in volumetric modulated arc therapy (VMAT) for both flattened and flattening filter free (FFF) beams. A general calibration model was created using a Varian TrueBeam accelerator, equipped with an aS1000 EPID, for each photon spectrum 6 MV, 10 MV, 6 MV-FFF, 10 MV-FFF. As planned VMAT treatments use control points (CPs) for optimization, measured images are separated into corresponding time intervals for direct comparison with predictions. The accuracy of the calibration model was determined for a range of treatment conditions. Measured and predicted CP dose images were compared using a time dependent gamma evaluation using criteria (3%, 3 mm, 0.5 sec). Time dependent pre-treatment dose verification is possible without an additional measurement device or phantom, using the on-board EPID. Sufficient data is present in trajectory log files and EPID frame headers to reliably synchronize and resample portal images. For the VMAT plans tested, significantly more deviation is observed when analysed in a time dependent manner for FFF and non-FFF plans than when analysed using only the integrated field. We show EPID-based pre-treatment dose verification can be performed on a CP basis for VMAT plans. This model can measure pre-treatment doses for both flattened and unflattened beams in a time dependent manner which highlights deviations that are missed in integrated field verifications.


Subject(s)
Diagnostic Imaging , Electrical Equipment and Supplies , Radiometry/instrumentation , Radiotherapy, Intensity-Modulated/standards , Calibration , Humans , Radiotherapy Planning, Computer-Assisted , Time Factors
9.
Acta Oncol ; 52(7): 1484-9, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24000957

ABSTRACT

UNLABELLED: Atelectasis in lung cancer patients can change rapidly during a treatment course, which may displace the tumor/healthy tissues, or change tissue densities locally. This may result in differences between the planned and the actually delivered dose. With complex delivery techniques treatment verification is essential and inter-fractional adaptation may be necessary. We present the first clinical results of treatment adaptation based on an in-house developed three-dimensional (3D) portal dose measurement (PDM) system. MATERIAL AND METHODS: A method was developed for 3D PDM combined with cone beam computed tomography (kV-CBCT) imaging. Lung cancer patients are monitored routinely with this imaging technique. During treatment, the first three fractions are analyzed with 3D PDM and weekly thereafter. The reconstructed measured dose is compared to the planned dose using dose-volume histograms and a γ evaluation. Patients having |γ|> 1 in more than 5% of the (primary tumor or organ at risk) volume were subjected to further analysis. In this study we show the PDM dose changes for five patients. RESULTS: We detected relevant dose changes induced by changes in atelectasis in the presented cases. Two patients received two treatment adaptations after being detected with PDM confirmed by visual inspection of the kV-CBCTs, and in two other patients the radiation treatment plan was adapted once. In one case no dose delivery change was detected with PDM. CONCLUSION: The first clinical patients show that 3D PDM combined with kV-CBCT is a valuable quality assurance tool for detecting anatomical alterations and their dosimetric consequences during the course of radiotherapy. In our clinic, 3D PDM is fully automated for ease and speed of the procedure, and for minimization of human error. The technique is able to flag patients with suspected dose discrepancies for potential adaptation of the treatment plan.


Subject(s)
Cone-Beam Computed Tomography , Image Processing, Computer-Assisted , Lung Neoplasms/radiotherapy , Pulmonary Atelectasis/radiotherapy , Radiometry , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated/adverse effects , Algorithms , Humans , Imaging, Three-Dimensional , Prognosis , Pulmonary Atelectasis/etiology , Radiographic Image Enhancement
10.
Med Phys ; 38(7): 4032-5, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21859001

ABSTRACT

PURPOSE: A widely accepted method to quantify differences in dose distributions is the gamma (gamma) evaluation. Currently, almost all gamma implementations utilize the central processing unit (CPU). Recently, the graphics processing unit (GPU) has become a powerful platform for specific computing tasks. In this study, we describe the implementation of a 3D gamma evaluation using a GPU to improve calculation time. METHODS: The gamma evaluation algorithm was implemented on an NVIDIA Tesla C2050 GPU using the compute unified device architecture (CUDA). First, several cubic virtual phantoms were simulated. These phantoms were tested with varying dose cube sizes and set-ups, introducing artificial dose differences. Second, to show applicability in clinical practice, five patient cases have been evaluated using the 3D dose distribution from a treatment planning system as the reference and the delivered dose determined during treatment as the comparison. A calculation time comparison between the CPU and GPU was made with varying thread-block sizes including the option of using texture or global memory. RESULTS: A GPU over CPU speed-up of 66 +/- 12 was achieved for the virtual phantoms. For the patient cases, a speed-up of 57 +/- 15 using the GPU was obtained. A thread-block size of 16 x 16 performed best in all cases. The use of texture memory improved the total calculation time, especially when interpolation was applied. Differences between the CPU and GPU gammas were negligible. CONCLUSIONS: The GPU and its features, such as texture memory, decreased the calculation time for gamma evaluations considerably without loss of accuracy.


Subject(s)
Algorithms , Neoplasms/radiotherapy , Numerical Analysis, Computer-Assisted , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Signal Processing, Computer-Assisted , Gamma Rays/therapeutic use , Humans , Radiotherapy Dosage
11.
Acta Med Port ; 3(5): 293-6, 1990.
Article in Portuguese | MEDLINE | ID: mdl-1963997

ABSTRACT

The authors present a clinical case of a patient with a bronchiolo alveolar lung carcinoma with an unusual form of presentation: secretory pattern with large amounts of bronchial secretion--1000 cc per day--. At the same time, a theoretical approach of lung adenocarcinoma is made, in particular the bronchiolo alveolar carcinoma, in which it concerns clinical, radiological, diagnosis, prognosis and therapeutical aspects.


Subject(s)
Adenocarcinoma, Bronchiolo-Alveolar/diagnosis , Lung Neoplasms/diagnosis , Adenocarcinoma, Bronchiolo-Alveolar/complications , Adenocarcinoma, Bronchiolo-Alveolar/therapy , Adult , Humans , Lung Neoplasms/complications , Lung Neoplasms/therapy , Male , Prognosis
SELECTION OF CITATIONS
SEARCH DETAIL
...