Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 136
Filter
1.
Braz J Cardiovasc Surg ; 38(6): e20230015, 2023 10 05.
Article in English | MEDLINE | ID: mdl-37797247

ABSTRACT

OBJECTIVE: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). METHODS: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 patients with symptomatic, moderate, or severe valve disease who underwent BVP implants in the timeframe from 2013 to 2020 at three Brazilian institutions. Death, valve-related adverse events (AEs), functional recovery, and hemodynamic performance were evaluated at the hospital, at discharge, and six months and one year later. Primary analysis compared late (> 30 days after implant) linearized rates of valve-related AEs, such as thromboembolism, valve thrombosis, major hemorrhage, major paravalvular leak, and endocarditis, following objective performance criteria (OPC). Analysis was performed to include at least 400 valve-years for each valve position (aortic and mitral) for complete comparisons to OPC. Kaplan-Meier survival and major adverse cardiovascular and cerebrovascular event analyses were also performed. RESULTS: This retrospective study analyzed follow-up data collected from 903 patients (834.2 late patient-years) who have undergone surgery for 455 isolated aortic valve replacement (50.4%), 382 isolated mitral valve replacement (42.3%), and 66 combined valve replacement or other intervention (7.3%). The linearized rates of valve-related AEs were < 2 × OPC. One-year survival rates were 95.1% and 92.7% for aortic and mitral valve replacement, respectively. This study demonstrated an improvement in the New York Heart Association classification from baseline and hemodynamic performance within an expected range. CONCLUSION: According to this analysis, BVP meets world standards for safety and clinical efficacy.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Animals , Cattle , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Pericardium/transplantation , Postoperative Complications/etiology , Prosthesis Design , Retrospective Studies , Treatment Outcome
2.
Arq Bras Cardiol ; 120(1): e20220892, 2023 01 23.
Article in English, Portuguese | MEDLINE | ID: mdl-36700596
3.
Arq. bras. cardiol ; 120(1): e20220892, 2023. tab, graf
Article in Portuguese | LILACS, CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1420149
4.
Rev. bras. cir. cardiovasc ; 38(6): e20230015, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1507833

ABSTRACT

ABSTRACT Objective: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). Methods: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 patients with symptomatic, moderate, or severe valve disease who underwent BVP implants in the timeframe from 2013 to 2020 at three Brazilian institutions. Death, valve-related adverse events (AEs), functional recovery, and hemodynamic performance were evaluated at the hospital, at discharge, and six months and one year later. Primary analysis compared late (> 30 days after implant) linearized rates of valve-related AEs, such as thromboembolism, valve thrombosis, major hemorrhage, major paravalvular leak, and endocarditis, following objective performance criteria (OPC). Analysis was performed to include at least 400 valve-years for each valve position (aortic and mitral) for complete comparisons to OPC. Kaplan-Meier survival and major adverse cardiovascular and cerebrovascular event analyses were also performed. Results: This retrospective study analyzed follow-up data collected from 903 patients (834.2 late patient-years) who have undergone surgery for 455 isolated aortic valve replacement (50.4%), 382 isolated mitral valve replacement (42.3%), and 66 combined valve replacement or other intervention (7.3%). The linearized rates of valve-related AEs were < 2 × OPC. One-year survival rates were 95.1% and 92.7% for aortic and mitral valve replacement, respectively. This study demonstrated an improvement in the New York Heart Association classification from baseline and hemodynamic performance within an expected range. Conclusion: According to this analysis, BVP meets world standards for safety and clinical efficacy.

5.
Rev. bras. cir. cardiovasc ; 37(1): 1-6, Jan.-Feb. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1365542

ABSTRACT

Abstract Introduction: Coronary artery bypass grafting (CABG) performed with and without cardiopulmonary bypass (CPB) support has been widely discussed in the literature. However, little is known about the outcomes of those techniques in Brazil. This study aims at exploring 30-day mortality and morbidity outcomes of on- and off-pump isolated CABG in a large sample from Southern Brazil. Methods: A single-center cohort with 1,767 patients undergoing isolated CABG (January 2013 - December 2018) was initially evaluated. Patients undergoing off-pump (N=397) and on-pump (N=1,370) CABG were identified. To obtain two completely homogeneous study groups, propensity score matching was used. The paired groups were compared by descriptive and univariate analyses. Then, logistic regression was used to verify the effects of on- and off-pump CABG on 30-day mortality. Results: None of the baseline characteristics showed significant difference between the groups (P>0.05). None of the analyzed morbidity outcomes showed any difference between the groups, including acute myocardial infarction (3.0% vs. 1.5%; P=0.192), stroke (2.4% vs. 4.2%; P=0.193), and major reoperation (0.6% vs. 0.3%; P=1.000), as well as the major adverse cardiovascular and cerebrovascular events composite outcome (6.3% vs. 7.5%; P=0.541). Mortality also did not differ (1.5% vs. 2.4%; P=0.401), and CPB support was not an independent predictor of risk for 30-day mortality (odds ratio: 2.052; 95% confidence interval: 0,609-6.913; P=0.246). Conclusion: After matching by propensity analyses, similar rates of on- and off-pump 30-day mortality and other major outcomes were observed. In addition, the use of CPB support was not an independent predictor of risk for the occurrence of 30-day mortality.

6.
Braz J Cardiovasc Surg ; 37(1): 1-6, 2022 03 10.
Article in English | MEDLINE | ID: mdl-35072394

ABSTRACT

INTRODUCTION: Coronary artery bypass grafting (CABG) performed with and without cardiopulmonary bypass (CPB) support has been widely discussed in the literature. However, little is known about the outcomes of those techniques in Brazil. This study aims at exploring 30-day mortality and morbidity outcomes of on- and off-pump isolated CABG in a large sample from Southern Brazil. METHODS: A single-center cohort with 1,767 patients undergoing isolated CABG (January 2013 - December 2018) was initially evaluated. Patients undergoing off-pump (N=397) and on-pump (N=1,370) CABG were identified. To obtain two completely homogeneous study groups, propensity score matching was used. The paired groups were compared by descriptive and univariate analyses. Then, logistic regression was used to verify the effects of on- and off-pump CABG on 30-day mortality. RESULTS: None of the baseline characteristics showed significant difference between the groups (P>0.05). None of the analyzed morbidity outcomes showed any difference between the groups, including acute myocardial infarction (3.0% vs. 1.5%; P=0.192), stroke (2.4% vs. 4.2%; P=0.193), and major reoperation (0.6% vs. 0.3%; P=1.000), as well as the major adverse cardiovascular and cerebrovascular events composite outcome (6.3% vs. 7.5%; P=0.541). Mortality also did not differ (1.5% vs. 2.4%; P=0.401), and CPB support was not an independent predictor of risk for 30-day mortality (odds ratio: 2.052; 95% confidence interval: 0,609-6.913; P=0.246). CONCLUSION: After matching by propensity analyses, similar rates of on- and off-pump 30-day mortality and other major outcomes were observed. In addition, the use of CPB support was not an independent predictor of risk for the occurrence of 30-day mortality.


Subject(s)
Coronary Artery Disease , Postoperative Complications , Brazil/epidemiology , Coronary Artery Bypass/adverse effects , Coronary Artery Disease/surgery , Humans , Propensity Score , Retrospective Studies , Risk Factors , Treatment Outcome
9.
Précoma, Dalton Bertolim; Oliveira, Gláucia Maria Moraes de; Simão, Antonio Felipe; Dutra, Oscar Pereira; Coelho, Otávio Rizzi; Izar, Maria Cristina de Oliveira; Póvoa, Rui Manuel dos Santos; Giuliano, Isabela de Carlos Back; Filho, Aristóteles Comte de Alencar; Machado, Carlos Alberto; Scherr, Carlos; Fonseca, Francisco Antonio Helfenstein; Filho, Raul Dias dos Santos; Carvalho, Tales de; Avezum Jr, Álvaro; Esporcatte, Roberto; Nascimento, Bruno Ramos; Brasil, David de Pádua; Soares, Gabriel Porto; Villela, Paolo Blanco; Ferreira, Roberto Muniz; Martins, Wolney de Andrade; Sposito, Andrei C; Halpern, Bruno; Saraiva, José Francisco Kerr; Carvalho, Luiz Sergio Fernandes; Tambascia, Marcos Antônio; Coelho-Filho, Otávio Rizzi; Bertolami, Adriana; Filho, Harry Correa; Xavier, Hermes Toros; Neto, José Rocha Faria; Bertolami, Marcelo Chiara; Giraldez, Viviane Zorzanelli Rocha; Brandão, Andrea Araújo; Feitosa, Audes Diógenes de Magalhães; Amodeo, Celso; Souza, Dilma do Socorro Moraes de; Barbosa, Eduardo Costa Duarte; Malachias, Marcus Vinícius Bolívar; Souza, Weimar Kunz Sebba Barroso de; Costa, Fernando Augusto Alves da; Rivera, Ivan Romero; Pellanda, Lucia Campos; Silva, Maria Alayde Mendonça da; Achutti, Aloyzio Cechella; Langowiski, André Ribeiro; Lantieri, Carla Janice Baister; Scholz, Jaqueline Ribeiro; Ismael, Silvia Maria Cury; Ayoub, José Carlos Aidar; Scala, Luiz César Nazário; Neves, Mario Fritsch; Jardim, Paulo Cesar Brandão Veiga; Fuchs, Sandra Cristina Pereira Costa; Jardim, Thiago de Souza Veiga; Moriguchi, Emilio Hideyuki; Moriguchi, Emilio Hideyuki; Schneider, Jamil Cherem; Assad, Marcelo Heitor Vieira; Kaiser, Sergio Emanuel; Lottenberg, Ana Maria; Magnoni, Carlos Daniel; Miname, Marcio Hiroshi; Lara, Roberta Soares; Herdy, Artur Haddad; Araújo, Cláudio Gil Soares de; Milani, Mauricio; Silva, Miguel Morita Fernandes da; Stein, Ricardo; Lucchese, Fernando Antônio; Nobre, Fernando; Griz, Hermilo Borba; Magalhães, Lucélia Batista Neves Cunha; Borba, Mario Henrique Elesbão de; Pontes, Mauro Ricardo Nunes; Mourilhe-Rocha, Ricardo.
Arq. bras. cardiol ; 116(4): 855-855, abr. 2021.
Article in Portuguese | LILACS | ID: biblio-1285194
10.
J Environ Manage ; 274: 111140, 2020 Nov 15.
Article in English | MEDLINE | ID: mdl-32795814

ABSTRACT

Invasive alien plants are a major threat to biodiversity and they contribute to the unfavourable conservation status of habitats of interest to the European Community. In order to favour implementation of European Union Regulation no. 1143/2014 on invasive alien species, the Italian Society of Vegetation Science carried out a large survey led by a task force of 49 contributors with expertise in vegetation across all the Italian administrative regions. The survey summed up the knowledge on impact mechanisms of invasive alien plants in Italy and their outcomes on plant communities and the EU habitats of Community Interest, in accordance with Directive no. 92/43/EEC. The survey covered 241 alien plant species reported as having deleterious ecological impacts. The data collected illustrate the current state of the art, highlight the main gaps in knowledge, and suggest topics to be further investigated. In particular, the survey underlined competition as being the main mechanism of ecological impact on plant communities and Natura 2000 habitats. Of the 241 species, only Ailanthus altissima was found to exert an ecological impact on plant communities and Natura 2000 habitats in all Italian regions; while a further 20 species impact up to ten out of the 20 Italian administrative regions. Our data indicate that 84 out of 132 Natura 2000 Habitats (64%) are subjected to some degree of impact by invasive alien plants. Freshwater habitats and natural and semi-natural grassland formations were impacted by the highest number of alien species, followed by coastal sand dunes and inland dunes, and forests. Although not exhaustive, this research is the first example of nationwide evaluation of the ecological impacts of invasive alien plants on plant communities and Natura 2000 Habitats.


Subject(s)
Ecosystem , Introduced Species , Biodiversity , Italy , Plants
13.
Précoma, Dalton Bertolim; Oliveira, Gláucia Maria Moraes de; Simão, Antonio Felipe; Dutra, Oscar Pereira; Coelho, Otávio Rizzi; Izar, Maria Cristina de Oliveira; Póvoa, Rui Manuel dos Santos; Giuliano, Isabela de Carlos Back; Filho, Aristóteles Comte de Alencar; Machado, Carlos Alberto; Scherr, Carlos; Fonseca, Francisco Antonio Helfenstein; Filho, Raul Dias dos Santos; Carvalho, Tales de; Avezum Jr, Álvaro; Esporcatte, Roberto; Nascimento, Bruno Ramos; Brasil, David de Pádua; Soares, Gabriel Porto; Villela, Paolo Blanco; Ferreira, Roberto Muniz; Martins, Wolney de Andrade; Sposito, Andrei C; Halpern, Bruno; Saraiva, José Francisco Kerr; Carvalho, Luiz Sergio Fernandes; Tambascia, Marcos Antônio; Coelho-Filho, Otávio Rizzi; Bertolami, Adriana; Filho, Harry Correa; Xavier, Hermes Toros; Neto, José Rocha Faria; Bertolami, Marcelo Chiara; Giraldez, Viviane Zorzanelli Rocha; Brandão, Andrea Araújo; Feitosa, Audes Diógenes de Magalhães; Amodeo, Celso; Souza, Dilma do Socorro Moraes de; Barbosa, Eduardo Costa Duarte; Malachias, Marcus Vinícius Bolívar; Souza, Weimar Kunz Sebba Barroso de; Costa, Fernando Augusto Alves da; Rivera, Ivan Romero; Pellanda, Lucia Campos; Silva, Maria Alayde Mendonça da; Achutti, Aloyzio Cechella; Langowiski, André Ribeiro; Lantieri, Carla Janice Baister; Scholz, Jaqueline Ribeiro; Ismael, Silvia Maria Cury; Ayoub, José Carlos Aidar; Scala, Luiz César Nazário; Neves, Mario Fritsch; Jardim, Paulo Cesar Brandão Veiga; Fuchs, Sandra Cristina Pereira Costa; Jardim, Thiago de Souza Veiga; Moriguchi, Emilio Hideyuki; Schneider, Jamil Cherem; Assad, Marcelo Heitor Vieira; Kaiser, Sergio Emanuel; Lottenberg, Ana Maria; Magnoni, Carlos Daniel; Miname, Marcio Hiroshi; Lara, Roberta Soares; Herdy, Artur Haddad; Araújo, Cláudio Gil Soares de; Milani, Mauricio; Silva, Miguel Morita Fernandes da; Stein, Ricardo; Lucchese, Fernando Antônio; Nobre, Fernando; Griz, Hermilo Borba; Magalhães, Lucélia Batista Neves Cunha; Borba, Mario Henrique Elesbão de; Pontes, Mauro Ricardo Nunes; Mourilhe-Rocha, Ricardo.
Arq. bras. cardiol ; 113(4): 787-891, Oct. 2019. tab, graf, ilus
Article in English | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1150799
14.
Braz J Cardiovasc Surg ; 33(4): 391-397, 2018.
Article in English | MEDLINE | ID: mdl-30184037

ABSTRACT

INTRODUCTION: The interest in Expert systems has increased in the medical area. Some of them are employed even for diagnosis. With the variability of transcatheter prostheses, the most appropriate choice can be complex. This scenario reveals an enabling environment for the use of an Expert system. The goal of the study was to develop an Expert system based on artificial intelligence for supporting the transcatheter aortic prosthesis selection. METHODS: The system was developed on Expert SINTA. The rules were created according to anatomical parameters indicated by the manufacturing company. Annular aortic diameter, aortic area, aortic perimeter, ascending aorta diameter and Valsalva sinus diameter were considered. After performing system accuracy tests, it was applied in a retrospective cohort of 22 patients with submitted to the CoreValve prosthesis implantation. Then, the system indications were compared to the real heart team decisions. RESULTS: For 10 (45.4%) of the 22 patients there was no concordance between the Expert system and the heart team. In all cases with discordance, the software was right in the indication. Then, the patients were stratified in two groups (same indication vs. divergent indication). The baseline characteristics did not show any significant difference. Mortality, stroke, acute myocardial infarction, atrial fibrillation, atrioventricular block, aortic regurgitation and prosthesis leak did not present differences. Therefore, the maximum aortic gradient in the post-procedure period was higher in the Divergent Indication group (23.9 mmHg vs. 11.9 mmHg, P=0.03), and the mean aortic gradient showed a similar trend. CONCLUSION: The utilization of the Expert system was accurate, showing good potential in the support of medical decision. Patients with divergent indication presented high post-procedure aortic gradients and, even without clinical repercussion, these parameters, when elevated, can lead to early prosthesis dysfunction and the necessity of reoperation.


Subject(s)
Artificial Intelligence , Heart Valve Prosthesis/standards , Transcatheter Aortic Valve Replacement/standards , Aged , Aged, 80 and over , Clinical Decision-Making , Female , Humans , Male , Reference Standards , Reproducibility of Results , Retrospective Studies , Software Design , Statistics, Nonparametric
15.
Rev. bras. cir. cardiovasc ; 33(4): 391-397, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-958426

ABSTRACT

Abstract Introduction: The interest in Expert systems has increased in the medical area. Some of them are employed even for diagnosis. With the variability of transcatheter prostheses, the most appropriate choice can be complex. This scenario reveals an enabling environment for the use of an Expert system. The goal of the study was to develop an Expert system based on artificial intelligence for supporting the transcatheter aortic prosthesis selection. Methods: The system was developed on Expert SINTA. The rules were created according to anatomical parameters indicated by the manufacturing company. Annular aortic diameter, aortic area, aortic perimeter, ascending aorta diameter and Valsalva sinus diameter were considered. After performing system accuracy tests, it was applied in a retrospective cohort of 22 patients with submitted to the CoreValve prosthesis implantation. Then, the system indications were compared to the real heart team decisions. Results: For 10 (45.4%) of the 22 patients there was no concordance between the Expert system and the heart team. In all cases with discordance, the software was right in the indication. Then, the patients were stratified in two groups (same indication vs. divergent indication). The baseline characteristics did not show any significant difference. Mortality, stroke, acute myocardial infarction, atrial fibrillation, atrioventricular block, aortic regurgitation and prosthesis leak did not present differences. Therefore, the maximum aortic gradient in the post-procedure period was higher in the Divergent Indication group (23.9 mmHg vs. 11.9 mmHg, P=0.03), and the mean aortic gradient showed a similar trend. Conclusion: The utilization of the Expert system was accurate, showing good potential in the support of medical decision. Patients with divergent indication presented high post-procedure aortic gradients and, even without clinical repercussion, these parameters, when elevated, can lead to early prosthesis dysfunction and the necessity of reoperation.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Heart Valve Prosthesis/standards , Artificial Intelligence , Transcatheter Aortic Valve Replacement/standards , Reference Standards , Software Design , Reproducibility of Results , Retrospective Studies , Statistics, Nonparametric , Clinical Decision-Making
16.
Eur J Cardiothorac Surg ; 51(3): 539-546, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28082464

ABSTRACT

Objectives: Emergent and late conversions form OFF-to-ON pump coronary artery bypass grafting (CABG) have been associated with worse outcomes, however, it remains unclear as to which risk factors are associated with conversion and how to prevent them. Methods: Among 4718 patients who randomly underwent off- or on-pump CABG, the incidence of off-pump to on-pump cross-over, or 'OFF-to-ON conversion', was 7.9% (186/2356). The primary outcome was a composite of death, stroke, myocardial infarction, or new renal failure requiring dialysis. We assessed the risk factors and outcomes of converted patients. Results: Emergent OFF-to-ON conversions, defined as conversions for hypotension or ischaemia, were required for 3.2% of patients ( n = 75), while most elective conversions were due to small or intramuscular coronaries ( n = 83). OFF-to-ON converted patients required increased surgery time, blood transfusions, intensive care unit stay, and presented a higher incidence at 1 year of the composite outcome compared with non-converted off-pump patients (all P < 0.01), especially if the conversion was emergent. Conversely, elective conversions outcomes were no different compared with non-converted off-pump patients ( P = 0.35). Independent predictors of emergent conversions included higher heart rate or chronic atrial fibrillation, urgent surgery, more grafts planned and surgeon experience with off-pump CABG. Conclusions: Emergent OFF-to-ON conversion is associated with worse outcomes compared with elective conversion or no conversion. In the presence of risk factors for emergent conversion, an early and elective conversion approach is a judicious strategy.


Subject(s)
Cardiopulmonary Bypass/adverse effects , Coronary Artery Bypass, Off-Pump/adverse effects , Aged , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Double-Blind Method , Female , Humans , Intraoperative Care/methods , Intraoperative Complications/therapy , Intraoperative Period , Kaplan-Meier Estimate , Male , Middle Aged , Risk Factors , Treatment Outcome
17.
Eur J Cardiothorac Surg ; 51(3): 539-546, 2017. graf, tab
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062623

ABSTRACT

OBJECTIVES: Emergent and late conversions form OFF-to-ON pump coronary artery bypass grafting (CABG) have been associated with worse outcomes, however, it remains unclear as to which risk factors are associated with conversion and how to prevent them. METHODS: Among 4718 patients who randomly underwent off- or on-pump CABG, the incidence of off-pump to on-pump cross-over, or 'OFF-to-ON conversion', was 7.9% (186/2356). The primary outcome was a composite of death, stroke, myocardial infarction, or new renal failure requiring dialysis. We assessed the risk factors and outcomes of converted patients. RESULTS: Emergent OFF-to-ON conversions, defined as conversions for hypotension or ischaemia, were required for 3.2% of patients ( n  = 75), while most elective conversions were due to small or intramuscular coronaries ( n  = 83). OFF-to-ON converted patients required increased surgery time, blood transfusions, intensive care unit stay, and presented a higher incidence at 1 year of the composite outcome compared with non-converted off-pump patients (all P < 0.01), especially if the conversion was emergent. Conversely, elective conversions outcomes were no different compared with non-converted off-pump patients ( P  = 0.35). Independent predictors of emergent conversions included higher heart rate or chronic atrial fibrillation, urgent surgery, more grafts planned and surgeon experience with off-pump CABG...


Subject(s)
Extracorporeal Circulation , General Surgery , Intraoperative Care , Myocardial Revascularization
19.
Rev. bras. cardiol. invasiva ; 23(2): 152-155, abr.-jun. 2015. ilus
Article in Portuguese | LILACS | ID: lil-787001

ABSTRACT

O implante de valva aórtica transcateter (TAVI) é uma alternativa para pacientes com estenose aórtica de alto risco cirúrgico e para muitos daqueles considerados inoperáveis. Apesar de sua característica minimamente invasiva, podem ocorrer complicações relacionadas ao procedimento. Obstrução coronária durante o TAVI é uma complicação rara, com incidência inferior a 1%, mas potencialmente letal. Em nosso país, essa complicação foi encontrada em 0,72% dos procedimentos − 3 de 418 casos do Registro Brasileiro de Implante de Bioprótese Aórtica por Cateter − com mortalidade hospitalar de 100%. Apresentamos, neste relato de caso, medidas de prevenção e tratamento de oclusão coronária após o TAVI.


Transcatheter aortic valve implantation (TAVI) is an alternative for patients with aortic stenosis at high surgical risk and for many of those considered inoperable. Despite its minimally invasive features,complications related to the procedure may occur. Coronary obstruction during TAVI is a rare (incidence rate of less than 1%) but potentially lethal complication. In Brazil, this complication was found in 0.72% of procedures – three of 418 cases from the Brazilian Transcatheter Aortic Valve Implantation Registry – with an in-hospital mortality rate of 100%. This case report presents prevention and treatment measures forcoronary occlusion after TAVI.


Subject(s)
Humans , Female , Aged , Aortic Valve Stenosis/therapy , Heart Valve Prosthesis Implantation/methods , Coronary Occlusion/complications , Coronary Occlusion/therapy , Angioplasty/methods , Femoral Artery , Catheters , Echocardiography/methods , Risk Factors , Percutaneous Coronary Intervention/methods , Stents , Aortic Valve/surgery
20.
Rev. bras. cir. cardiovasc ; 29(4): 494-504, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741721

ABSTRACT

Objective: To compare in-hospital outcomes in aortic surgery in our cardiac surgery unit, before and after foundation of our Center for Aortic Surgery (CTA). Methods: Prospective cohort with non-concurrent control. Foundation of CTA required specialized training of surgical, anesthetic and intensive care unit teams, routine neurological monitoring, endovascular and hybrid facilities, training of the support personnel, improvement of the registry and adoption of specific protocols. We included 332 patients operated on between: January/2003 to December/2007 (before-CTA, n=157, 47.3%); and January/2008 to December/2010 (CTA, n=175, 52.7%). Baseline clinical and demographic data, operative variables, complications and in-hospital mortality were compared between both groups. Results: Mean age was 58±14 years, with 65% male. Group CTA was older, had higher rate of diabetes, lower rates of COPD and HF, more non-urgent surgeries, endovascular procedures, and aneurysms. In the univariate analysis, CTA had lower mortality (9.7 vs. 23.0%, P=0.008), which occurred consistently across different diseases and procedures. Other outcomes which were reduced in CTA included lower rates of reinterventions (5.7 vs 11%, P=0.046), major complications (20.6 vs. 33.1%, P=0.007), stroke (4.6 vs. 10.9%, P=0.045) and sepsis (1.7 vs. 9.6%, P=0.001), as compared to before-CTA. Multivariable analysis adjusted for potential counfounders revealed that CTA was independently associated with mortality reduction (OR=0.23, IC 95% 0.08 – 0.67, P=0.007). CTA independent mortality reduction was consistent in the multivariable analysis stratified by disease (aneurysm, OR=0.18, CI 95% 0.03 – 0.98, P=0.048; dissection, OR=0.31, CI 95% 0.09 – 0.99, P=0.049) and by procedure (hybrid, OR=0.07, CI 95% 0.007 – 0.72, P=0.026; Bentall, OR=0.18, CI 95% 0.038 – 0.904, P=0.037). Additional multivariable predictors of in-hospital mortality included creatinine ...


Objetivo: Comparar desfechos intrahospitalares em pacientes submetidos a cirurgia da aorta torácica e toracoabdominal, antes e após a constituição do Centro Especializado de Tratamento da Aorta (CTA). Métodos: Coorte prospectiva com controle não contemporâneo. A criação do CTA envolveu treinamento cirúrgico especializado, sala híbrida, monitorização neurológica, capacitação de pessoal de apoio, aperfeiçoamento dos registros e uso de protocolos específicos. Foram incluídos 332 pacientes operados em 2 períodos: janeiro/2003 a dezembro/2007 (pré-CTA, n=157, 47,3%); e janeiro/2008 a dezembro/2010 (CTA, n=175, 52,7%). As características demográficas, clínicas, dados cirúrgicos, complicações e mortalidade hospitalar foram comparados nos 2 grupos. Resultados: A idade média foi 58±14 anos, com 65% sexo masculino. O grupo CTA teve idade, prevalência de diabete (DM) e glicemia maiores; menor prevalência de doença pulmonar obstrutiva crônica e insuficiência cardíaca; maior proporção de aneurismas e cirurgias eletivas; e mais procedimentos endovasculares que o pré-CTA. Na análise univariada, o grupo CTA mostrou redução de mortalidade (9,7% x 23,0%, P=0,008), que foi consistente nos diferentes subgrupos estratificados por patologia e por procedimento. O grupo CTA teve também redução de reoperações (5,7% x 11%, P=0,046), complicações maiores (20,6% x 33,1%, P=0,007), acidente vascular cerebral (4,6% x 10,9%, P=0,045) e sepse (1,7% x 9,6%, P=0,001), comparado ao pré-CTA. Na análise multivariada, o CTA se associou de forma independente a redução de mortalidade hospitalar (OR=0,23, IC 95% 0,08 - 0,67, P=0,007). A redução de mortalidade do CTA também ocorreu na análise estratificada por patologia (cirurgias de aneurisma, OR=0,18, IC 95% 0,03 - 0,98, P=0,048; cirurgias de dissecção, OR=0,31, IC 95% 0,09 - 0,99, P=0,049) e por procedimento (híbridos, OR=0,07, IC 95% 0,007 - 0,72, P=0,026; Bentall, OR=0,18, IC 95% 0,038 – 0,904, P=0,037). Também foram ...


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Aorta/surgery , Aortic Diseases/mortality , Aortic Diseases/surgery , Hospitals, Special/statistics & numerical data , Aortic Valve/surgery , Coronary Artery Bypass/methods , Coronary Artery Bypass/mortality , Epidemiologic Methods , Endovascular Procedures/methods , Hospital Mortality , Intensive Care Units , Length of Stay , Sex Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...