Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 77: 138-145, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32829102

ABSTRACT

PURPOSE: Megavoltage radiotherapy to irregular superficial targets is challenging due to the skin sparing effect. We developed a three-dimensional bolus (3DB) program to assess the clinical impact on dosimetric and patient outcomes. MATERIALS AND METHODS: Planar commercial bolus (PCB) and 3DB density, clarity, and net bolus effect were rigorously evaluated prior to clinical implementation. After IRB approval, patients with cutaneous or locally advanced malignancies deemed to require bolus for radiotherapy treatment were treated with custom 3DB. RESULTS: The mean density of 3DB and PCB was of 1.07 g/cm 3 and 1.12 g/cm3, respectively. 3DB optic clarity was superior versus PCB at any material thickness. Phantom measurements of superficial dose with 3DB and PCB showed excellent bolus effect for both materials. 3DB reduced air gaps compared with PCB - particularly in irregular areas such as the ear, nose, and orbit. A dosimetric comparison of 3DB and PCB plans showed equivalent superficial homogeneity for 3DB and PCB (3DB median HI 1.249, range 1.111-1.300 and PCB median HI 1.165, range 1.094-1.279), but better conformity with 3DB (3DB median CI 0.993, range 0.962-0.993) versus PCB (PCB median CI 0.977, range 0.601-0.991). Patient dose measurements using 3DB confirm the delivered superficial dose was within 1% of the intended prescription (95% CI 97-102%; P = 0.11). CONCLUSIONS: 3DB improves radiotherapy plan conformity, reduces air gap volume in irregular superficial areas which could affect superficial dose delivery, and provides excellent dose coverage to irregular superficial targets.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Intensity-Modulated , Head and Neck Neoplasms/radiotherapy , Humans , Phantoms, Imaging , Printing, Three-Dimensional , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
2.
J Neurophysiol ; 118(6): 3252-3270, 2017 12 01.
Article in English | MEDLINE | ID: mdl-28855286

ABSTRACT

Traditionally, head fixation devices and recording cylinders have been implanted in nonhuman primates (NHP) using dental acrylic despite several shortcomings associated with acrylic. The use of more biocompatible materials such as titanium and PEEK is becoming more prevalent in NHP research. We describe a cost-effective set of procedures that maximizes the integration of headposts and recording cylinders with the animal's tissues while reducing surgery time. Nine rhesus monkeys were implanted with titanium headposts, and one of these was also implanted with a recording chamber. In each case, a three-dimensional printed replica of the skull was created based on computerized tomography scans. The titanium feet of the headposts were shaped, and the skull thickness was measured preoperatively, reducing surgery time by up to 70%. The recording cylinder was manufactured to conform tightly to the skull, which was fastened to the skull with four screws and remained watertight for 8.5 mo. We quantified the amount of regression of the skin edge at the headpost. We found a large degree of variability in the timing and extent of skin regression that could not be explained by any single recorded factor. However, there was not a single case of bone exposure; although skin retracted from the titanium, skin also remained adhered to the skull adjacent to those regions. The headposts remained fully functional and free of complications for the experimental life of each animal, several of which are still participating in experiments more than 4 yr after implant.NEW & NOTEWORTHY Cranial implants are often necessary for performing neurophysiology research with nonhuman primates. We present methods for using three-dimensional printed monkey skulls to form and fabricate acrylic-free implants preoperatively to decrease surgery times and the risk of complications and increase the functional life of the implant. We focused on reducing costs, creating a feasible timeline, and ensuring compatibility with existing laboratory systems. We discuss the importance of using more biocompatible materials and enhancing osseointegration.


Subject(s)
Biocompatible Materials , Biomedical Research/methods , Head , Implants, Experimental , Neurophysiology/methods , Titanium , Animals , Biocompatible Materials/standards , Biomedical Research/instrumentation , Female , Implants, Experimental/standards , Macaca mulatta , Male , Neurophysiology/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...