1.
Eur Radiol ; 29(12): 6858-6866, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31175414

ABSTRACT

OBJECTIVES: Diagnostic performance and potential radiation dose reduction of wide-area detector CT sequential acquisition ("wide-volume" acquisition (WV)) in unenhanced chest examination are unknown. This study aims to assess the image quality, the diagnostic performance, and the radiation dose reduction of WV mode compared with the classical helical acquisition for lung parenchyma analysis in an ultra-low-dose (ULD) protocol. METHODS: After Institutional Review Board Approval and written informed consent, 64 patients (72% men; 67.6 ± 9.7 years old; BMI 26.1 ± 5.3 kg/m2) referred for a clinically indicated unenhanced chest CT were prospectively included. All patients underwent, in addition to a standard helical acquisition (120 kV, automatic tube current modulation), two ULD acquisitions (135 kV, fixed tube current at 10 mA): one in helical mode and one in WV mode. Image noise, subjective image quality (5-level Likert scale), and diagnostic performance for the detection of 9 predetermined parenchymal abnormalities were assessed by two radiologists and compared using the chi-square or Fisher non-parametric tests. RESULTS: Subjective image quality (4.2 ± 0.7 versus 4.2 ± 0.8, p = 0.56), image noise (41.7 ± 8 versus 40.9 ± 8.7, p = 0.3), and diagnostic performance were equivalent between ULD WV and ULD helical. Radiation dose was significantly lower for the ULD WV acquisition (mean dose-length product 14.1 ± 1.3 mGy cm versus 15.8 ± 1.3, p < 0.0001). CONCLUSION: An additional 11% dose reduction is achieved with the WV mode in ULD chest CT with fixed tube current, with equivalent image quality and diagnostic performance when compared with the helical acquisition. KEY POINTS: • Image quality and diagnostic performance of ultra-low-dose unenhanced chest CT are identical between wide-volume mode and the reference helical acquisition. • Wide-volume mode allows an additional radiation dose reduction of 11% (mean dose-length product 14.1 ± 1.3 mGy cm versus 15.8 ± 1.3, p < 0.0001).


Subject(s)
Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Clinical Protocols , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Tomography, Spiral Computed/methods
2.
Presse Med ; 45(3): 291-301, 2016 Mar.
Article in French | MEDLINE | ID: mdl-26830922

ABSTRACT

Ultra-low dose chest CT (ULD-CT) is acquired at a radiation dose lowered to that of a PA and lateral chest X-ray. Its image quality is degraded, yet remains diagnostic in many clinical indications. Technological improvements, with iterative reconstruction at the foreground, allowed a strong increase in the image quality obtained with this examination, which is achievable on most recent (<5 years) scanner. Established clinical indications of ULD-CT are increasing, and its non-inferiority compared to the reference "full dose" chest CT are currently demonstrated for the detection of solid nodules, for asbestos-related pleural diseases screening and for the monitoring of infectious pneumonia. Its current limitations are the obese patients (BMI>35) and the interstitial pneumonia, situations in which their performances are insufficient.


Subject(s)
Lung Diseases/diagnostic imaging , Radiography, Thoracic/trends , Tomography, X-Ray Computed/methods , Asbestosis/diagnostic imaging , Contrast Media , Equipment Design , France , Humans , Image Processing, Computer-Assisted/methods , Image-Guided Biopsy , Lung/diagnostic imaging , Mediastinum/diagnostic imaging , Neoplasm Staging/methods , Obesity/complications , Pleura/diagnostic imaging , Pleural Neoplasms/diagnostic imaging , Public Health/legislation & jurisprudence , Radiation Dosage , Radiation Exposure , Radiography, Thoracic/instrumentation , Radiography, Thoracic/methods , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/instrumentation