Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Echocardiography ; 40(7): 657-663, 2023 07.
Article in English | MEDLINE | ID: mdl-37248818

ABSTRACT

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is conventionally performed under continuous transesophageal echocardiographic (TEE) guidance. We aimed to evaluate whether a simplified procedural approach, including pure fluoroscopy-guidance and final TEE control, as well as an aimed 'next-day-discharge' is comparable with the conventional TEE-guided procedure in terms of periprocedural and intermediate-term outcomes. METHODS: All patients who underwent a PFO closure at our center between 2010 and 2022 were retrospectively included. Prior to June 2019 cases were performed with continuous TEE guidance (TEE-guided group). Since June 2019, only pure fluoroscopy-guided PFO closures have been performed with TEE insertion and control just prior to device release (fluoroscopy-guided group). We analyzed procedural aspects, as well as long term clinical and echocardiographic outcomes. RESULTS: In total 291 patients were included in the analysis: 197 in the TEE-guided group and 94 in the fluoroscopy-guided group. Fluoroscopy-guided procedures were markedly shorter (48 ± 20 min vs. 25 ± 9 min; p < .01). There was no difference in procedural complications, including death, major bleeding, device dislodgement, stroke or clinically relevant peripheral embolization between the two groups (.5% vs. 0%; p = .99). Hospital stay was also shorter with the simplified approach (2.5 ± 1.6 vs. 3.5 ± 1.2 days; p < .01), allowing 85% same-day discharges during the last 12 months of observation period. At 6 ± 3 months echocardiographic follow-up a residual leakage was described in 8% of the TEE-guided cases and 2% of the fluoroscopy-guided cases (p = .08). CONCLUSION: While a complete TEE-free PFO closure might have potential procedural risks, our approach of pure fluoroscopy-guided with a brisk final TEE check seems to be advantageous in terms of procedural aspects with no sign of any acute or intermediate-term hazard and it could offer an equitable compromise between the two worlds: a complete TEE procedure and a procedure without any TEE.


Subject(s)
Foramen Ovale, Patent , Septal Occluder Device , Humans , Echocardiography, Transesophageal/methods , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/surgery , Retrospective Studies , Treatment Outcome , Fluoroscopy/methods , Cardiac Catheterization/methods , Registries
2.
J Clin Med ; 9(10)2020 Oct 13.
Article in English | MEDLINE | ID: mdl-33066034

ABSTRACT

BACKGROUND: Complete real-world data on the indications and outcomes of left atrial appendage closure (LAAC) outside of clinical trials are rare. In this study, we stratified patients undergoing LAAC by indication groups. METHODS: This analysis of the national multicentre Austrian LAAC Registry comprised all patients that underwent LAAC up until 2018 at the currently active centres in Austria. The baseline characteristics, procedural details and outcomes between the following indication groups were compared: bleeding as an indication for LAAC ("bleeding" group) vs. thromboembolism despite oral anticoagulation (OAC; "thromboembolism" group) vs. an intolerance to OAC for reasons other than the above ("other" group). RESULTS: The analysis included 186 patients, with 59.7% in the "bleeding" group, 8.1% in the "thromboembolism" group and 32.2% in the "other" group. The CHADS2 score was the highest in the "thromboembolism" group and the HAS-BLED score was the highest in the "bleeding" group. The procedural outcomes were similar between groups (implantation success, 97.3%), with major complications occurring in 7.0% of patients. One-year survival free from stroke, bleeding or LAAC-associated hospitalisation was 83.9%, 90.0% and 81.4% in the "bleeding", "thromboembolism" and "other" groups, respectively (p = 0.891). CONCLUSIONS: In routine clinical practice, LAAC was used in a heterogeneous patient population with atrial fibrillation (AF) and contraindication, inefficacy or intolerance to OAC. The long-term outcome was favourable in all groups.

3.
Cardiol J ; 26(3): 233-240, 2019.
Article in English | MEDLINE | ID: mdl-29611164

ABSTRACT

BACKGROUND: Devices currently used to achieve hemostasis of the femoral artery following percutaneous cardiac catheterization are associated with vascular complications and remnants of artificial materials are retained at the puncture site. The Secure arterial closure Device induces hemostasis by utilizing thermal energy, which causes collagen shrinking and swelling. In comparison to established devices, it has the advantage of leaving no foreign material in the body following closing. This study was designed to evaluate the efficacy and safety of the Secure Device to close the puncture site following percutaneous cardiac catheterization. METHODS: The Secure Device was evaluated in a prospective non-randomized single-center trial with patients undergoing 6 F invasive cardiac procedures. A total of 67 patients were enrolled and the device was utilized in 63 patients. Fifty diagnostic and 13 interventional cases were evaluated. Femoral artery puncture closure was performed immediately after completion of the procedure. Time to hemostasis (TTH), time to ambulation (TTA) and data regarding short-term and 30-day clinical follow-up were recorded. RESULTS: Mean TTH was 4:30 ± 2:15 min in the overall observational group. A subpopulation of patients receiving anticoagulants had a TTH of 4:53 ± 1:43 min. There were two access site complications (hematoma > 5 cm). No major adverse events were identified during hospitalization or at the 30 day follow-up. CONCLUSIONS: The new Secure Device demonstrates that it is feasible in diagnostic and interventional cardiac catheterization. With respect to safety, the Secure Device was non-inferior to other closure devices as tested in the ISAR closure trial.


Subject(s)
Catheterization, Peripheral , Femoral Artery , Hemorrhage/prevention & control , Hemostatic Techniques/instrumentation , Aged , Austria , Cardiac Catheterization , Catheterization, Peripheral/adverse effects , Equipment Design , Feasibility Studies , Female , Femoral Artery/diagnostic imaging , Hemorrhage/etiology , Hemostatic Techniques/adverse effects , Humans , Male , Middle Aged , Prospective Studies , Punctures , Time Factors , Treatment Outcome
4.
JACC Cardiovasc Interv ; 11(21): 2160-2167, 2018 11 12.
Article in English | MEDLINE | ID: mdl-30409272

ABSTRACT

OBJECTIVES: This study sought to investigate the outcome of high-risk and inoperable patients with severe symptomatic aortic stenosis undergoing transfemoral transcatheter aortic valve replacement (TAVR) in hospitals with (iOSCS) versus without institutional on-site cardiac surgery (no-iOSCS). BACKGROUND: Current guidelines recommend the use of TAVR only in institutions with a department for cardiac surgery on site. METHODS: In this analysis of the prospective multicenter Austrian TAVI registry, 1,822 consecutive high-risk patients with severe symptomatic aortic stenosis undergoing transfemoral TAVR were evaluated. A total of 290 (15.9%) underwent TAVR at no-iOSCS centers (no-iOSCS group), whereas the remaining 1,532 patients (84.1%) were treated in iOSCS centers (iOSCS group). RESULTS: Patients of the no-iOSCS group had a higher perioperative risk defined by the logistic EuroSCORE (20.9% vs. 14.2%; p < 0.001) compared with patients treated in hospitals with iOSCS. Procedural survival was 96.9% in no-iOSCS centers and 98.6% in iOSCS centers (p = 0.034), whereas 30-day survival was 93.1% versus 96.0% (p = 0.039) and 1-year survival was 80.9% versus 86.1% (p = 0.017), respectively. After propensity score matching for confounders procedural survival was 96.9% versus 98.6% (p = 0.162), 93.1% versus 93.8% (p = 0.719) at 30 days, and 80.9% versus 83.4% (p = 0.402) at 1 year. CONCLUSIONS: Patients undergoing transfemoral TAVR in hospitals without iOSCS had a significantly higher baseline risk profile. After propensity score matching short- and long-term mortality was similar between centers with and without iOSCS.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiac Surgical Procedures , Cardiology Service, Hospital , Catheterization, Peripheral , Femoral Artery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Austria , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/mortality , Female , Humans , Male , Prospective Studies , Registries , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
5.
J Electrocardiol ; 50(4): 402-409, 2017.
Article in English | MEDLINE | ID: mdl-28274541

ABSTRACT

BACKGROUND: There is controversial evidence if atrial fibrillation (AF) alters outcome after transcatheter aortic valve implantation (TAVI). TAVI itself may promote new-onset AF (NOAF). METHODS: We performed a single-center study including 398 consecutive patients undergoing TAVI. Before TAVI, patients were divided into a sinus rhythm (SR) group (n=226, 57%) and baseline AF group (n=172, 43%) according to clinical records and electrocardiograms. Furthermore, incidence and predictors of NOAF were recorded. RESULTS: Baseline AF patients had a significantly higher 1-year mortality than the baseline SR group (19.8% vs. 11.5%, p=0.02). NOAF occurred in 7.1% of patients with prior SR. Previous valve surgery was the only significant predictor of NOAF (HR 5.86 [1.04-32.94], p<0.05). NOAF was associated with higher rehospitalization rate (62.5 vs. 34.8%, p=0.04), whereas mortality was unaffected. CONCLUSIONS: This study shows that NOAF is associated with higher rates of rehospitalization but not mortality after TAVI. Overall, patients with pre-existing AF have higher mortality.


Subject(s)
Atrial Fibrillation/epidemiology , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Atrial Fibrillation/mortality , Austria/epidemiology , Electrocardiography , Female , Humans , Incidence , Male , Patient Readmission/statistics & numerical data , Postoperative Complications/mortality , Risk Factors , Treatment Outcome
8.
Innovations (Phila) ; 11(2): 84-93, 2016.
Article in English | MEDLINE | ID: mdl-26889881

ABSTRACT

OBJECTIVE: This study aimed to evaluate a novel device system for surgical aortic valve replacement (SAVR) using a unique new less invasive access approach. The hypothesis is that SAVR can be performed through a short transverse incision in the neck, similar to that used for transcervical thymectomy avoiding chest disruption. METHODS: A new device system was developed to provide retraction, step-by-step illumination, and on-screen visualization for the new approach. Preliminary feasibility studies were performed in cadavers. Comprehensive risk analysis was performed, and training was implemented in Thiel preserved cadavers. For the first-in-man clinical case, a 63-year-old woman with symptomatic critical aortic stenosis (The Society of Thoracic Surgeons risk, 11%) and heavily calcified aortic valve was selected. A short transverse incision was made in the neck; the device was introduced, and the sternum was elevated; femorofemoral cardiopulmonary bypass was established; substernal dissection was guided by the sequenced illumination, and high-definition visualization was provided by the device, allowing for optimal exposition of the aorta and aortic valve; and a 23-mm Medtronic ENABLE sutureless valve prosthesis was implanted. Procedure success was evaluated according to the standardized composite end point definition of "device success" proposed by the Valve Academic Research Consortium. RESULTS: Access, delivery, and deployment of the valve prosthesis were successful. The correct position and intended performance of the valve were demonstrated (mean gradient, 6 mm Hg; aortic valve area, 2.5 cm) with the absence of moderate or severe prosthetic aortic regurgitation. Only one valve prosthesis was used. CONCLUSIONS: Transcervical SAVR with sutureless valve is feasible using this novel access system. The new approach has potential to offer patients substantially shorter stay and fewer, less serious complications, as has been observed in transcervical thymectomy. Further studies are merited.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiopulmonary Bypass/methods , Heart Valve Prosthesis Implantation/instrumentation , Cardiopulmonary Bypass/instrumentation , Female , Humans , Middle Aged , Minimally Invasive Surgical Procedures/instrumentation , Neck/surgery , Surgery, Computer-Assisted/methods , Treatment Outcome
10.
EuroIntervention ; 4(2): 242-9, 2008 Aug.
Article in English | MEDLINE | ID: mdl-19110790

ABSTRACT

AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.


Subject(s)
Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis/statistics & numerical data , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnostic imaging , Cause of Death , Device Approval , Echocardiography , Female , Humans , Male , Postoperative Complications/mortality , Prosthesis Design , Registries , Risk Management , Severity of Illness Index , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...