1.
Anal Chem ; 74(7): 1597-603, 2002 Apr 01.
Article in English | MEDLINE | ID: mdl-12033250

ABSTRACT

An optimal environment for glucose oxidase (GOx) in Nafion membranes is achieved using an advanced immobilization protocol based on a nonaqueous immobilization route. Exposure of glucose oxidase to water-organic mixtures with a high (85-95%) content of the organic solvent resulted in stabilization of the enzyme by a membrane-forming polyelectrolyte. Such an optimal environment leads to the highest enzyme specific activity in the resulting membrane, as desired for optimal use of the expensive oxidases. Casting solution containing glucose oxidase and Nafion is completely stable over 5 days in a refrigerator, providing almost absolute reproducibility of GOx-Nafion membranes. A glucose biosensor was prepared by casting the GOx-Nafion membranes over Prussian Blue-modified glassy carbon disk electrodes. The biosensor operated in the FIA mode allows the detection of glucose down to the 0.1 microM level, along with high sensitivity (0.05 A M(-1) cm(-2)), which is only 10 times lower than the sensitivity of the hydrogen peroxide transducer used. A comparison with the recently reported enzyme electrodes based on similar H2O2 transducers (transition metal hexacyanoferrates) shows that the proposed approach displays a dramatic (100-fold) improvement in sensitivity of the resulting biosensor. Combined with the attractive performance of a Prussian Blue-based hydrogen peroxide transducer, the proposed immobilization protocol provides a superior performance for first-generation glucose biosensors in term of sensitivity and detection limits.


Subject(s)
Biosensing Techniques/methods , Glucose Oxidase , Membranes, Artificial , Biosensing Techniques/standards , Electrodes , Enzymes, Immobilized , Fluorocarbon Polymers/chemistry , Glucose/analysis , Polymers/chemistry , Sensitivity and Specificity
2.
Bioelectrochemistry ; 55(1-2): 145-8, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11786361

ABSTRACT

Electropolymerisation of nonconducting polymer, poly-(1,2-diaminobenzene) on the top of Prussian Blue (PB) modified electrode led to significant improvement of resulting hydrogen peroxide transducer selectivity and operational stability. The reported transducer retained 100% of response during 20 h under the continuous flow of 0.1 mM H(2)O(2), and thus improves the stability level in selective peroxide detection by one order of magnitude. The selectivity value of the PB-poly(1,2-DAB) based H(2)O(2) sensor in relation to ascorbate is approximately 600. No signals to acetaminophen and urate were investigated. PB-poly(1,2-diaminobenzene) modified electrode allows the detection of H(2)O(2) in the flow-injection mode down to 10(-7) M with the sensitivity 0.3 A M(-1) cm(-2), which is only two times lower compared to the uncovered PB based transducer.


Subject(s)
Electrodes , Ferrocyanides/chemistry , Hydrogen Peroxide/chemistry , Phenylenediamines/chemical synthesis