Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
J Clin Med ; 12(11)2023 May 27.
Article in English | MEDLINE | ID: mdl-37297907

ABSTRACT

Restoring teeth with dental implants has become the gold standard in recent years, especially in the esthetic zone. However, limited amount of available bone as well as limited interdental space in the anterior zone may create problems for implant treatment. Narrow diameter implants (NDI) may be a treatment option to resolve the above-mentioned limitations and providing minimally invasive implant therapy without additional regenerative procedures. In this retrospective study, a comparison of clinical and radiographic outcomes between one-piece and two-piece titanium-made NDIs was done with the follow-up of two years after loading. Twenty-three NDI cases were analyzed, 11 in the one-piece implant group (group one) and 12 in the two-piece implant group (group two). The outcomes were implant and prosthetic failures, any complications occurred, peri-implant bone level changes, and as well as the Pink Esthetic score. No implant or prosthetic failures, as well as, no complications were reported at the two-year follow-up examination. At the same time the marginal bone loss was 0.23 ± 0.11 in the group one and 0.18 ± 0.12 in the group two. Difference was not statistically significant (p = 0.3339). The Pink Esthetic Score, recorded two years after definitive loading, was 12.6 ± 0.97 in the group one and 12.2 ± 0.92 in the group two, with no statistically significant difference between groups (p = 0.3554). With the limitations of the present study, including the small sample size and short follow-up, it is possible to conclude that either one and two-piece NDI can be successfully used to restore lateral incisors with comparable results within the two years of follow-up.

2.
J Craniomaxillofac Surg ; 50(5): 462-467, 2022 May.
Article in English | MEDLINE | ID: mdl-35430134

ABSTRACT

Among healthcare workers, oral and maxillofacial surgeons are some of the most exposed to coronavirus disease (COVID-19). The aim of this retrospective study was to develop suggestions for continuing the work of oral and maxillofacial surgeons using a safe protocol for elective and urgent aerosol-generating procedures that could prevent the onset of new clusters. Based on the results obtained and a guidelines review of those Asian countries that had promptly managed the current pandemic, the following safety protocol was developed.


Subject(s)
COVID-19 , Oral Surgical Procedures , Aerosols , COVID-19/prevention & control , Humans , Pandemics/prevention & control , Retrospective Studies , SARS-CoV-2
3.
Materials (Basel) ; 15(2)2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35057240

ABSTRACT

To evaluate the implant and prosthetic of two implants with different surfaces and neck design. Enrolled patients received bone level, 12° conical connection implants (Nobel Parallel, Nobel Biocare; NOBEL group) with anodized surface (TiUnite) and roughness of 1.35 µm, or transmucosal implant system (Prama, Sweden and Martina; PRAMA group) with convergent collar, ZIrTi surface, and roughness 1.4-1.7 µm. Both implants were made of pure grade IV titanium, with similar diameter and length, chosen according to the dentistry department availability and patient's request. After early prosthesis delivery, patients were filled for at least one year. Outcome measures were: implant and prosthetic survival and success rates, physiological marginal bone remodeling, periodontal parameters and pink esthetic score (PES). Results: Fifteen patients were allocated and treated in each group. At the one-year follow-up, three patients dropped out, one in the NOBEL group and two in the PRAMA group. During the entire time of investigation, all implants survived and the prostheses were successful. No statistically significant differences were found in term of marginal bone loss, periodontal parameters, and aesthetics (p > 0.05). Conclusion: With the limitations of the present study, both implant systems showed successful clinical results. Finally, many other clinical and surgical variables may influenced marginal bone levels, implant survival, and periodontal parameters. More homogenous clinical trials with larger samples are needed to confirm these preliminary conclusions.

4.
Eur J Dent ; 16(4): 787-795, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34991163

ABSTRACT

OBJECTIVE: The purpose of the present prospective, case-series study was to report implant survival rate and marginal bone remodeling expected 5 years after loading using dental implants placed in daily practice. MATERIALS AND METHODS: This research was designed as an open-cohort, prospective, case-series evaluation. Any partially or completely edentulous patient, scheduled to receive at least one bone level implant, was considered eligible for this study. Primary outcome measurements were: implant and prosthetic cumulative survival rate and any complications experienced up to the 5-year follow-up. Secondary outcome measures were: thickness of gingival biotype, implant insertion torque, implant stability quotient, and marginal bone loss (MBL). RESULTS: Ninety consecutive patients (34 males and 56 females, aged between 24 and 81 years old [mean: 53.2 ± 15.4]) with 243 inserted implants were followed for at least 5 years after loading (mean: 65.4 ± 3.1 months; range from 60 to 72). At the 1-year follow-up, no drop-outs were recorded, but 17 patients (18.9%) with 18 restorations (12.6%) delivered on 34 implants (14%) were lost at the 5-year examination. At the 5-year follow-up examination, six implants lost osseointegration (97.5%). In the same period, four prostheses failed (97.2%). Five complications were reported in five different patients (prosthetic success rate was 96.5%, at patient level). Five years after loading, the mean MBL was 0.41 ± 0.30 mm. The difference from the 1-year data was 0.04 ± 0.19 mm. A statistically significant higher MBL was found for smokers, and patients with thin gingival biotype. The mean implant insertion torque was 42.9 ± 4.8 Ncm (range from 15 to 45 Ncm). Two-hundred and three implants (83.5%) were inserted with an insertion torque ≥35 and ≤45 Ncm. CONCLUSIONS: High implant survival and success rate could be expected with stable marginal bone remodeling up to 5 years after loading. Smoking and thin tissue biotype were the most important variabilities associated with higher MBL. Further research studies are needed to confirm these results.

5.
Dent J (Basel) ; 9(4)2021 Mar 24.
Article in English | MEDLINE | ID: mdl-33804864

ABSTRACT

Implant design factors and the abutment connection are correlated with crestal bone stability. The aim of the present study was to evaluate a new type of screw-retained prostheses delivered on tissue-level implants with conical external vertical seal and internal hexagon connection. Implants 4.25 mm in diameter and 10 mm in length (Prama, Sweden and Martina) were placed in partially edentulous patients needing at least one implant in the healed site, having sufficient bone volume. The implant neck was positioned above the bone crest. A healing abutment was placed according to a one-stage approach. Outcome measures were implant and prosthesis survival rate, any complications, marginal bone loss (MBL), periodontal parameters, and pink esthetic score (PES). Overall, 13 patients (4 women and 9 men; mean age 50 ± 22 years) with the same number of implants were treated and followed for one year after loading. At the 12-month follow up, no implant and no prosthesis failed, and no complications were experienced. The mean MBL experienced at the one year follow-up was 0.65 ± 0.48 mm. One year after loading, 2 out of 13 implants present bleeding on probing (15.4%), 4 out of 13 patients presented with plaque at the one year of follow-up (30.8%) and the PES was 10.5 ± 2.3 mm. Within the limitations of the present study, the analyzed implants seem to be a viable treatment option for the rehabilitation of a single tooth gap.

6.
Clin Implant Dent Relat Res ; 23(3): 380-387, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33611832

ABSTRACT

BACKGROUND: Surgical templates are classified as noncritical devices, and they do not need to be sterile. AIM: Primary aim of this study was to assess the microbiological burden present on the surgical templates without metallic sleeves after disinfection. Furthermore, to evaluate trueness after disinfection and steam sterilization at 121°C/15 min, and over a 8-week storage period. Finally, to assess their accuracy after in vitro implant placement simulation. MATERIALS AND METHODS: Forty surgical templates were printed and divided in five groups of eight templates each. Groups A to C were disinfected with 0.5% Chlorhexidine Gluconate and 70% ethyl alcohol base solution for 15 min. Templates in the group D were steam sterilized at 121°C for 15 min, while, the templates in the group E were used as control. Implant simulation was performed in the group A. Outcome measures were determination of bioburden, trueness assessment using GOM Inspect Professional software, and accuracy evaluated thought the mean angular deviation of simulated implants. RESULTS: Total microbic charge measured as colony forming units (CFU) for sample, was 24.40 in the control group (group E; n = 8), and <4.40 in the test group (group C; n = 8), with a reduction of 84%. Colored representation from GOM inspection showed no differences after disinfection and implant simulation, disinfection alone, and steam sterilization, compared to the control group. A very small difference in the surface and volume dimensions was reported 1 month after templates fabrication. The mean roundness tolerances of the tested templates improved of 0.96 ± 0.56° (95% CI 0.57-1.35). CONCLUSION: Surgical templates without metallic sleeves can be safely used after disinfection, demonstrating high level of accuracy, even when the surgical procedures should be postponed within a couple of weeks. Further in vivo study are needed to confirm these preliminary results.


Subject(s)
Computer-Aided Design , Surgery, Computer-Assisted , Disinfection , Software
7.
Eur J Dent ; 15(2): 290-294, 2021 May.
Article in English | MEDLINE | ID: mdl-33622005

ABSTRACT

OBJECTIVE: Preliminary data on survival and success rates of immediately loaded, maxillary, screw-retained, implant-supported, fixed restorations delivered on narrow and low-profile OT Equator abutments (OT Bridge, Rhein'83) were evaluated. MATERIALS AND METHODS: This retrospective study evaluated data collected from patients rehabilitated with OT Bridge prosthetic concept between November 2017 and February 2019 in six different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. RESULTS: A total of 76 implants were inserted in 14 patients. Patients were followed for a mean period of 15.8 months (range = 12-24). All the patients receive OT Equator (Rhein'83) as intermediate abutments. One year after loading, one implant failed (1.3%). None of the prosthesis failed. One prosthetic complication was experienced in one patient. Three out of 76 implants were connected to the prosthetic framework using only the Seeger system, without screw. Difference in OHIP values was statistically significant (71.9 ± 8.5; p = 0.000). One year after loading, MBL was 0.21 ± 0.11 mm and p-value was 0.000. One year after loading, 8.7% of the examined implant sites present positive bleeding on probing, while 6.4% of the implant sites presented plaque. CONCLUSION: The OT Equator abutments (Rhein'83) showed successful results when used to support maxillary fixed dental prosthesis delivered on four to six implants. High implant and prosthetic survival rates, very low complications, high patient satisfaction, and good biological parameters, including only 0.2 mm of bone remodeling were experienced one year after function. Further studies are needed to confirm these preliminary results.

8.
J Funct Biomater ; 12(1)2021 Feb 04.
Article in English | MEDLINE | ID: mdl-33557297

ABSTRACT

The aim of this retrospective study was to clinically evaluate the five-year outcomes of implants placed following a combined approach to the sinus, consisting of sequential drills and osteotomes. Medical records of patients with implants placed in combination with crestal sinus lift using sequential drills and osteotomes, with a residual alveolar bone crest between 4 to 8 mm, and a follow-up of at least five years after final loading, were evaluated. Outcomes were implant and prosthetic survival and success rates, any complication, and marginal bone loss. Data from 96 patients (53 women and 43 men; mean age 54.7 years; range 23-79 years) were collected. A total of 105 single implants were analyzed. After five years of function, two implants were lost and two prostheses failed. No major biological or prosthetic complications occurred. At the five-year examination, the marginal bone loss was 1.24 ± 0.28 mm. Within the limitations of this retrospective study it can be concluded that implants placed following a combined approach to the sinus consisting of sequential drills and osteotomes seem to be a viable option for the treatment of posterior atrophic edentulous maxilla.

9.
Materials (Basel) ; 15(1)2021 Dec 29.
Article in English | MEDLINE | ID: mdl-35009400

ABSTRACT

The purpose of the present study was to evaluate the histological and histomorphometric characteristics of post-extraction sites grafted with decellularized bovine compact bone from bovine femur, mixed and unmixed with leukocyte- and platelet-rich fibrin after four months of healing. This study was designed as a randomized controlled trial of parallel groups. Patients in need of a single, implant-supported restoration to replace a hopeless tooth were recruited for tooth extraction and implant placement four months after socket preservation procedure. After tooth extraction, patients were randomly allocated to receive decellularized bovine compact bone from bovine femur, mixed and unmixed with leukocyte- and platelet-rich fibrin. After four months of healing, tapered implants were inserted with an insertion torque between 35 and 45 Ncm. Two months later, implants were loaded with screw-retained definitive crowns. Outcome measures were implant (ISR) and prosthesis (PSR) survival rates, complications, histological and histomorphometric analyses, radiographic marginal bone-level changes, and patients' satisfaction. Clinical data were collected up to one year after tooth extraction and socket preservation procedures. Thirty patients were consecutively enrolled in the trial (15 in each group). Unfortunately, due to the COVID-19 pandemic, bone samples were collected only in 19 patients. Two implants failed before definitive prosthesis delivery (ISR 93.3%). No prosthesis failed (PSR 100%). Three complications were experienced in the control group. The mean bone percentage was 40.64 ± 18.76 in the test group and 33.40 ± 22.38 in the control group. The difference was not statistically significant (p = 0.4846). The mean soft tissue percentage was 32.55 ± 19.45 in the test group and 55.23 ± 17.64 in the control group. The difference was statistically significant (p = 0.0235). The mean residual graft was 24.59 ± 18.39 in the test group and 11.37 ± 12.12 in the control group. The difference was not statistically significant (p = 0.0992). Mean marginal bone loss, as well as patient satisfaction, showed no differences between groups. With the limitations of the present study, socket preservation with L-PRF mixed with decellularized bovine compact bone demonstrated favorable results, comparing with decellularized bovine compact bone from bovine femur alone. Further studies with larger sample size and longer follow-up are needed to confirm these preliminary results.

10.
Eur J Dent ; 15(1): 1-7, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33242915

ABSTRACT

OBJECTIVE: To compare early implant failure and implant stability of one-stage Hiossen ET III implants with its new hydrophilic (NH) surface, compared with Hiossen ET III implants with the sandblasted and acid-etched (SA) surface at 1-year follow-up. MATERIALS AND METHODS: This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values. RESULTS: Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17-41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02-41.98) Ncm in the NH group (p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group (p = 0.041). Similar results were found in the maxilla (p = 0.045), but not in the mandible (p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66). CONCLUSIONS: NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.

11.
Eur J Dent ; 14(S 01): S171-S176, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33321548

ABSTRACT

The purpose of the present narrative review was to evaluate and discuss the actual available information regarding coronavirus disease 2019 and dental practice, and to share recommendations with the intent to help dentists in providing a safe and healthful workplace during pandemic. A step-by-step workflow is presented including prevention and measures to reduce risk for cross infections before, during, and after the dental treatments. Individualization of different risk-level zones and the establishment of a team-based chain control is also presented. The present manuscript may offer deeper knowledge and discussion regarding recommended procedures aimed to reduce risk for dental health care workers contamination and cross infections. Within these, infection prevention in dental settings, respect of general rules, containment measures, proper use of the personal protective equipments (PPE), and well-organized chain control of all the staff, with definition of risk zones and specific responsibility could be an adjunctive but important step to control the spread of the disease.

12.
Dent J (Basel) ; 8(4)2020 Dec 15.
Article in English | MEDLINE | ID: mdl-33333998

ABSTRACT

Crest module can be defined as the portion of a two-piece implant designed to retain the prosthetic components and to allows the maintenance of the peri-implant tissues in the transition zone. AIM: To evaluate the three-year after loading clinical and radiographic data, collected from patients that received a prosthetic rehabilitation on conical connection implants with partial machined collar (PMC; CC Group) and same body-designed implants, with flat-to-flat connection and groovy neck design (FC Group). MATERIALS AND METHODS: A retrospective chart review of previously collected data, including documents, radiographs, and pictures of patients who received at least one implant-supported restoration on NobelReplace CC PMC or NobelReplace Tapered Groovy implants was performed. Patients with at least three years of follow-up after final loading were considered for this study. Outcomes measures were implant and prosthesis failures, any biological or technical complications, marginal bone loss. RESULTS: Eight-two patients (44 women, 38 men; average age 55.6) with 152 implants were selected and divided in two groups with 77 (CC group) and 75 (FC group), respectively. Three years after final loading, one implant in CC group failed (98.7% survival rate), while no implants failed in FC group (100% survival rate). One restoration failed in CC group (98.7% survival rate) with no restoration failing in the FC one (100% survival rate). Differences were not statistically significant (p = 1.0). Three years after final loading, mean marginal bone loss was 0.22 ± 0.06 mm (95% CI 0.2-0.24) in CC group and 0.62 ± 0.30 mm (95% CI 0.52-0.72) in FC group. The difference was statistically significant (0.40 ± 0.13 mm; 95% CI 0.3-0.5; p = 0.003). CONCLUSION: with the limitation of this retrospective comparative study, implants with conical connection and partial machined collar seem to achieve a trend of superior outcomes if compared with implants with flat connection and groovy collar design.

13.
Materials (Basel) ; 13(17)2020 Sep 02.
Article in English | MEDLINE | ID: mdl-32887390

ABSTRACT

Alveolar-ridge augmentation, anterior aesthetics, and digital technologies are probably the most popular topics in the dental-implant field. The aim of this report is to present a clinical case of severe atrophy of the anterior maxilla in a younger female patient, treated with a titanium membrane customized with computer-aided design/computer-aided manufacturing (CAD/CAM), simultaneous guided implant placement, and a fully digital workflow. A young female patient with a history of maxillary trauma was treated and followed-up for 1 year after implant placement. A narrow implant was inserted in a prosthetically driven position with the aid of computer-guided surgery. In the same surgical section, a customized implantable titanium mesh was applied. The scaffold was designed according to the contralateral maxillary outline in order to recreate a favorable maxillary bone volume. Finally, highly aesthetic, CAD/CAM, metal-free restorations were delivered using novel digital technologies.

14.
Materials (Basel) ; 13(16)2020 Aug 11.
Article in English | MEDLINE | ID: mdl-32796635

ABSTRACT

BACKGROUND: Intraoral scanners (IOSs) in implantology represent a viable approach for single teeth or partial arches. However, when used for complete edentulous arches or long-span edentulous areas, it has been demonstrated that there is a need for improvement of IOS-related techniques. Therefore, the aim of this in vitro study was to assess the trueness and precision of a complete arch digital impression on four and six implants taken with or without a customized, prosthetic-based impression template. MATERIALS AND METHODS: Two experimental models were prepared, representative of a complete edentulous mandible restored with four and six implants with built-in scan abutments. Models were scanned with (test group, TG) or without (control group, CG) the prosthetic-based impression template. Eight scans were taken for each model. The time needed to take impressions, error, trueness, and precision were evaluated. A statistical analysis was performed. RESULTS: In the case of four implants, the time needed for the impression was 128.7 ± 55.3 s in the TG and 81.0 ± 23.5 s in the CG (p = 0.0416). With six scan abutments, the time was 197.5 ± 26.8 and 110.6 ± 25.2 s in the TG and CG, respectively (p = 0.0000). In the TG, no errors were experienced, while in the CG, 13 impressions were retaken due to incorrect stitching processes. In the four-implant impression, the mean angle deviation was 0.252 ± 0.068° (95% CI 0.021-0.115°) in the CG and 0.134 ± 0.053° (95% CI 0.016-0.090°) in the TG. The difference was statistically significant (p = 0.002). In the six-implant impression, the mean angle deviation was 0.373 ± 0.117° (95% CI 0.036-0.198°) in the CG and 0.100 ± 0.029° (95% CI 0.009-0.049°) in the TG (p = 0.000). In the TG, there were no statistically significant differences in the mean angle deviation within the group (p > 0.05), but there were in the CG. A colorimetric analysis showed higher deviations from the original model for the six-implant impression without a prosthetic template. CONCLUSIONS: Although all of the impressions exhibited deviation from the original model in the range of clinical acceptability, the prosthetic-based impression template significantly improved the trueness and precision of complete edentulous arches rehabilitated with four or six implants, making the complete arch digital impression more predictable.

15.
Materials (Basel) ; 13(8)2020 Apr 16.
Article in English | MEDLINE | ID: mdl-32316361

ABSTRACT

The achievement of the optimal implant position is a critical consideration in implant surgery, as it can facilitate the ideal prosthesis design and allow adequate oral hygiene maintenance. The switch from bone-driven to prosthetic-driven implant placement, through a comprehensive diagnosis and adequate treatment plan, is a prerequisite for long-term successful implant-based therapy. The aim of the present case report is to describe a step-by-step prosthetic retreatment of a patient with primary treatment failure due to incorrect dental implant placement. Although dental implants achieve high survival rates, the success of implant prosthetic therapy significantly relies on an appropriate implant position. Malpositioned implants can cause damage to vital structures, like nerves or vessels. Moreover, improper implant positioning can result in esthetic, biological, and technical complications and can, in extreme situations, render the desired prosthetic rehabilitation impossible to achieve.

16.
Int J Oral Implantol (Berl) ; 13(1): 43-52, 2020.
Article in English | MEDLINE | ID: mdl-32186286

ABSTRACT

PURPOSE: To compare the clinical and radiographic outcomes of platform switching (PS) and regular platform (RP) implants. MATERIALS AND METHODS: This study was designed as a randomised controlled split-mouth trial. Eighteen patients, with bilaterally missing single premolars or molars to be restored with implant-supported single crowns, were consecutively enrolled. Implant sites were randomly assigned to be treated according to the PS concept (PS group), or with matching implant-abutment diameters (RP group). A total of 36 implants were placed in healed bone, with an insertion torque between 35 and 45 Ncm, according to a one-stage protocol. All the implants were loaded with a screw-retained provisional crown 3 months after implant insertion. Definitive screw-retained single crowns were delivered 2 months later. Outcome measures were implant and prosthetic survival rates, biological and prosthetic complications, marginal bone level (MBL) changes, pocket probing depth (PPD) and bleeding on probing (BOP). Clinical data were collected at implant placement (baseline), implant loading (3 months later) and at 9, 36 and 60 months after loading. RESULTS: One patient dropped out after 4 years of follow-up. No implant failed and no prosthetic complications were recorded during the study period. One patient experienced mucosal inflammation with positive BOP (RP group) after 3 months and three patients had bilateral peri-implant mucosal inflammation with positive BOP at 6, 24 and 36 months, respectively. No other biological complications were recorded up to 60 months of follow-up. There were no statistically significant differences between groups for complications (3/18 versus 4/18; P = 1.0). Nine months after loading the mean MBL was 0.93 ± 0.26 mm (95% CI 0.81 to 1.05) for RP implants and 0.84 ± 0.23 mm (95% CI 0.73 to 0.95) for PS implants. No statistically significant difference was observed between the groups (P = 0.18). Thirty-six months after loading, the mean MBL was 1.09 ± 0.31 mm (95% CI 0.95 to 1.24) in the RP group and 1.06 ± 0.24 mm (95% CI 0.94 to 1.17) in the PS group, with no statistically significant difference between groups (P = 0.70). Sixty months after loading the mean MBL was 1.24 ± 0.39 mm (95% CI 1.05 to 1.43) in the RP group and 1.20 ± 0.21 mm (95% CI 1.01 to 1.39) in the PS group, with no statistically significant difference between the groups (P = 0.85). The mean PPD was 2.58 ± 0.58 mm (95% CI 2.32 to 2.84) in the RP group and 2.40 ± 0.72 mm (95% CI 2.21 to 2.59) in the PS group at 60 months follow-up, with no statistically significant difference between the groups (P = 0.49). The mean BOP was 0.90 ± 0.88 (95% CI 0.58 to 1.22) in the RP group and 0.93 ± 0.97 (95% CI 0.51 to 1.35) in the PS group at 60 months of follow-up, with no statistically significant difference between the groups (P = 0.85). CONCLUSIONS: Implants restored according to the PS concept and matching implant-abutment diameters showed comparable clinical and radiographic results up to 5 years after loading.


Subject(s)
Dental Implants , Immediate Dental Implant Loading , Bicuspid , Crowns , Humans , Torque
17.
Int J Oral Implantol (Berl) ; 12(4): 483-492, 2019.
Article in English | MEDLINE | ID: mdl-31781701

ABSTRACT

PURPOSE: To compare the outcomes of implants inserted in maxillary sinuses augmented with 100% anorganic bovine bone (ABB) grafts versus mixed with 50% ABB and 50% autologous bone graft using a lateral window approach. MATERIALS AND METHODS: This study was designed as a randomised controlled trial of parallel groups. Patients in need of an implant-supported prosthesis in maxillary posterior areas, with a residual alveolar bone height ranging between 0 and 4 mm, were recruited for lateral sinus grafting and implant placement. Patients were randomly allocated to receive two different graft materials according to a parallel group design: group A was grafted with 50% ABB and 50% autogenous bone; group B was grafted with 100% ABB. After 7 months, tapered implants were inserted with an insertion torque between 20 and 45 Ncm. Three months later implants were loaded with screw-retained temporary crowns. Definitive crowns were delivered after 3 months. Outcome measures were implant and prosthesis survival rates, complications, radiographic marginal bone-level changes, probing pocket depths (PPDs) and bleeding on probing (BOP). Clinical data were collected at definitive prosthesis delivery, and 1, 2 and 5 years after definitive loading. RESULTS: Thirty-two consecutive patients were treated with 32 sinus elevation procedures (16 group A, 16 group B). A total of 46 implants were inserted. One patient (with two implants) dropped out in group A, and two patients (with three implants) dropped out in group B. No implant/crown failed by the end of the study. Three complications (one sinus membrane perforation and two chipping of the ceramic) were observed in three patients in group A, versus none in group B (relative risk was 0.81; 95% CI 0.64-1.03; P = 0.225). At the 2-year follow-up, the mean marginal bone loss was 1.18 ± 0.50 mm (95% CI 0.95-1.45 mm) in group A and 1.28 ± 0.48 mm (95% CI 0.97-1.43 mm) in group B, with no statistically significant differences between the two groups (difference 0.11 ± 0.22 mm; 95% CI -0.06-0.16 mm; P = 0.586). At the 5-year follow-up, the mean marginal bone loss was 1.37 ± 0.48 mm (95% CI 1.13-1.86 mm) in group A and 1.42 ± 0.48 mm (95% CI 1.17-1.90 mm) in group B (difference 0.15 ± 0.08 mm; 95% CI 0.10-0.22 mm; P = 0.426). At the 2-year follow-up, the mean PPD value was 2.70 ± 0.39 mm for group A and 2.54 ± 0.66 mm for group B, with no statistically significant difference between groups (difference 0.17 ± 0.39 mm; 95% CI 0.06-0.32 mm; P = 0.456). At the 5-year follow-up, the mean PPD value was 3.20 ± 0.44 mm for group A and 3.32 ± 0.49 mm for group B (difference 0.12 ± 0.43 mm; 95% CI 0.02-0.22 mm; P = 0.672). At the 2-year follow-up, the mean BOP value was 1.21 ± 0.79 for group A and 1.28 ± 0.68 for group B (difference 0.06 ± 0.49; 95% CI -0.23-0.25; P = 0.297), and at the 5-year follow-up, the mean BOP value was 1.77 ± 0.62 for group A and 1.91 ± 0.48 for group B (difference: 0.14 ± 0.51; 95% CI -0.05-0.33; P = 0.492). CONCLUSIONS: Within the limitations of this study, the present data confirm similar clinical outcomes of implants inserted in sinuses grafted with ABB versus implants inserted in sinuses grafted with mixed 50% ABB and 50% autologous bone.


Subject(s)
Bone Transplantation , Dental Implantation, Endosseous , Dental Prosthesis, Implant-Supported , Animals , Cattle , Dental Prosthesis Design , Dental Restoration Failure , Humans , Maxillary Sinus
18.
J Craniomaxillofac Surg ; 46(2): 293-298, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29275075

ABSTRACT

INTRODUCTION: The purpose of this study was to retrospectively evaluate the difference between the planned and the actual movements of the jaws, using three-dimensional (3D) software for PC-assisted orthognathic surgery, to establish the accuracy of the procedure. MATERIAL AND METHODS: A retrospective study was performed with 49 patients who had undergone PC-guided bimaxillary surgery. The accuracy of the protocol was determined by comparing planned movements of the jaws with the actual surgical movements, analysing frontal and lateral cephalometries. RESULTS: The overall results were deemed accurate, and differences among 12 of the 15 parameters were considered nonsignificant. Significant differences were reported for SNA (p = 0.008), SNB (p = 0.006), and anterior facial height (p = 0.033). The latter was significantly different in patients who had undergone genioplasty when compared with patients who had not. CONCLUSION: Virtual surgical planning presented a good degree of accuracy for most of the parameters assessed, with an average error of 1.98 mm for linear measures and 1.19° for angular measures. In general, a tendency towards under-projection in jaws was detected, probably due to imperfect condylar seating. A slight overcorrection of SNA and SNB during virtual planning (approximately 2°) could be beneficial. Further progress is required in the development of 3D simulation of the soft tissue, which currently does not allow an accurate management of the facial height and the chin position. Virtual planning cannot replace the need for constant intraoperative monitoring of the jaws' movements and real-time comparisons between planned and actual outcomes. It is therefore appropriate to leave some margin for correction of inaccuracies in the virtual planning. In this sense, it may be appropriate to use only the intermediate splint, and then use the planned occlusion and clinical measurements to guide repositioning of the second jaw and chin, respectively.


Subject(s)
Orthognathic Surgical Procedures , Surgery, Computer-Assisted , Adult , Facial Asymmetry/surgery , Female , Humans , Male , Malocclusion, Angle Class II/surgery , Malocclusion, Angle Class III/surgery , Open Bite/surgery , Orthognathic Surgical Procedures/methods , Reproducibility of Results , Retrospective Studies , Surgery, Computer-Assisted/methods
19.
Behav Brain Funct ; 9: 41, 2013 Oct 28.
Article in English | MEDLINE | ID: mdl-24165294

ABSTRACT

BACKGROUND: In some clinical cases, bruxism may be correlated to central nervous system hyperexcitability, suggesting that bruxism may represent a subclinical form of dystonia. To examine this hypothesis, we performed an electrophysiological evaluation of the excitability of the trigeminal nervous system in a patient affected by pineal cavernoma with pain symptoms in the orofacial region and pronounced bruxism. METHODS: Electrophysiological studies included bilateral electrical transcranial stimulation of the trigeminal roots, analysis of the jaw jerk reflex, recovery cycle of masseter inhibitory reflex, and a magnetic resonance imaging study of the brain. RESULTS: The neuromuscular responses of the left- and right-side bilateral trigeminal motor potentials showed a high degree of symmetry in latency (1.92 ms and 1.96 ms, respectively) and amplitude (11 mV and 11.4 mV, respectively), whereas the jaw jerk reflex amplitude of the right and left masseters was 5.1 mV and 8.9 mV, respectively. The test stimulus for the recovery cycle of masseter inhibitory reflex evoked both silent periods at an interstimulus interval of 150 ms. The duration of the second silent period evoked by the test stimulus was 61 ms and 54 ms on the right and left masseters, respectively, which was greater than that evoked by the conditioning stimulus (39 ms and 35 ms, respectively). CONCLUSIONS: We found evidence of activation and peripheral sensitization of the nociceptive fibers, the primary and secondary nociceptive neurons in the central nervous system, and the endogenous pain control systems (including both the inhibitory and facilitatory processes), in the tested subject. These data suggest that bruxism and central orofacial pain can coexist, but are two independent symptoms, which may explain why numerous experimental and clinical studies fail to reach unequivocal conclusions.


Subject(s)
Brain Neoplasms/physiopathology , Bruxism/physiopathology , Dystonic Disorders/physiopathology , Hemangioma, Cavernous, Central Nervous System/physiopathology , Pineal Gland/physiopathology , Trigeminal Nerve/physiopathology , Adult , Brain Neoplasms/pathology , Bruxism/pathology , Dystonic Disorders/pathology , Evoked Potentials, Motor/physiology , Hemangioma, Cavernous, Central Nervous System/pathology , Humans , Magnetic Resonance Imaging , Male , Masseter Muscle/physiopathology , Pineal Gland/pathology , Reaction Time/physiology , Transcranial Magnetic Stimulation
20.
Gut Pathog ; 5(1): 18, 2013 Jul 10.
Article in English | MEDLINE | ID: mdl-23842143

ABSTRACT

Oral lesions may be found in patients with Crohn's disease (CD), in a percentage up to 20%. The aim of this study was to investigate a possible relationship between Mycobacterium avium subsp. paratuberculosis (MAP) and oral lesions in CD patients. 23 oral biopsies were examined performing IS900 Nested PCR; 9 of them were positive: 8 from CD patients and 1 from a control. Our purpose is to go on with this study, amplifying the number of subjects examined and testing subjects with oral lesions related to diseases other than CD to verify the specific association between MAP and oral lesions in CD patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...