Scand J Clin Lab Invest ; 79(8): 590-594, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31642699

ABSTRACT

Infants are at risk for iron deficiency. Despite research advances, assessing iron stores during infancy remains a challenge to the clinician. Ferritin is the first-choice laboratory marker for measuring iron stores but it is today still unclear how to evaluate reference intervals among infants. We have studied Swedish infants (n = 456), born at term after normal pregnancies. Ferritin was measured at birth (umbilical cord sample), 48-72 h, 4 months and 12 months. Lower and upper reference interval limits were constructed as the 2.5th and 97.5th percentiles. By a large study population, we were able to use more stringent measures to avoid interference from the acute phase response than previous reports on ferritin reference intervals. When we used mathematical transformation we furthermore avoided potential information loss in precision and confirmed earlier reports of sex differences. At the lower reference interval limits there were small differences between sexes. For the higher limits, the differences were more pronounced in the older infant. At 0-3 d of age we observed a difference between the sexes of only 5% at the upper limits. The differences peaked at 12 months, where the boys' upper 97.5th percentile was 56% compared to girls.


Subject(s)
Ferritins/blood , Age Factors , Confidence Intervals , Humans , Infant , Infant, Newborn , Reference Values
2.
Clin Appl Thromb Hemost ; 22(7): 641-7, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26893443

ABSTRACT

BACKGROUND: Intravenous fluids with synthetic colloids such as hydroxyethyl starch (HES) are known to interfere with plasma fibrinogen concentration measurements. The aim of this study was to evaluate the effects of an HES solution on fibrinogen measurements in a clinical setting. METHODS: The study was performed in patients who received at least 1 L of HES during intracranial tumor resection surgery. Blood samples were drawn before the start of surgery (baseline), after infusion of 1 L of HES, and at later time points. The fibrinogen concentration was measured using 3 different methods: (a) enzyme-linked immunosorbent assay (ELISA), (b) Clauss method with a photometric readout, and (c) Clauss method with an electromechanical readout. In addition, the fibrin-based clot quality was evaluated with the thromboelastometric FIBTEM test. RESULTS: Forty patients were enrolled, and 25 patients were included in the analysis. The fibrinogen concentrations at baseline were 2.2, 2.3, and 2.6 g/L and after 1 L of HES 1.6, 1.7, and 1.9 g/L as measured by ELISA, the photometric test, and the electromechanical test, respectively. The electromechanical Clauss test measured significantly higher concentrations at these time points. The relative decrease, however, was comparable between methods (31%, 29%, and 25%, respectively) but significantly lower than the 44% relative decrease with FIBTEM maximum clot firmness. CONCLUSION: Despite providing different fibrinogen concentration values at baseline, the relative decrease in fibrinogen concentration after HES infusion was comparable among the 3 tests. In contrast, fibrin-based clot quality was more affected than fibrinogen concentration tests by HES infusion.


Subject(s)
Fibrinogen/pharmacology , Hydroxyethyl Starch Derivatives/pharmacology , Thrombelastography/methods , Cross-Sectional Studies , Female , Humans , Intraoperative Care , Male , Middle Aged