Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Foot Ankle Res ; 17(3): e12044, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39020474

ABSTRACT

INTRODUCTION: Controlled ankle motion (CAM) boots are a below-knee orthotic device prescribed for the management of foot and ankle injuries to reduce ankle range of motion (RoM) and offload the foot and ankle whilst allowing continued ambulation during recovery. There is a lack of clarity within the current literature surrounding the biomechanical understanding and effectiveness of CAM boots. AIMS: To summarise the biomechanical effects of CAM boot wear as an orthotic for restricting ankle RoM and offloading the foot. METHODS: A systematic literature review was conducted in accordance with the PRISMA 2020 guidelines. All papers were independently screened by two authors for inclusion. Methodological quality was appraised using Joanna Briggs Critical Appraisal checklists. A narrative synthesis of all eligible papers was produced. RESULTS: Thirteen studies involving 197 participants (113 male and 84 female) were included. All studies were quasi-randomised and employed a within-study design, of which 12 studies included a control group and a range of CAM boots were investigated. CAM boots can be seen to restrict ankle RoM, however, neighboring joints such as the knee and hip do have kinetic and kinematic compensatory alterations. Plantar pressure of the forefoot is effectively redistributed to the hindfoot by CAM boots. CONCLUSION: The compensatory mechanisms at the hip and knee joint during CAM boot wear could explain the secondary site pain often reported in patients, specifically at the ipsilateral knee and contralateral hip. Although CAM boots can be used to restrict ankle motion, this review has highlighted a lack of in-boot kinematic analyses during CAM boot use, where tracking markers are placed on the anatomical structure rather than on the boot, or through video fluoroscopy, urging the need for a more robust methodological approach to achieve this. There is a need for studies to assess the biomechanical alterations caused by CAM boots in populations living with foot and ankle pathologies. Future research, adopting a longitudinal study design, is required to fully understand the effectiveness of CAM boots for rehabilitation.


Subject(s)
Ankle Joint , Range of Motion, Articular , Shoes , Humans , Range of Motion, Articular/physiology , Biomechanical Phenomena/physiology , Ankle Joint/physiology , Female , Male , Ankle Injuries/physiopathology , Ankle Injuries/rehabilitation , Foot Orthoses , Adult
2.
Gait Posture ; 108: 208-214, 2024 02.
Article in English | MEDLINE | ID: mdl-38118224

ABSTRACT

BACKGROUND: Controlled ankle motion (CAM) boots are often prescribed during the rehabilitation of lower limb injuries and pathologies to reduce foot and ankle movement and loading whilst allowing the patient to maintain normal daily function. RESEARCH QUESTION: The aim of this study was to quantify the compensatory biomechanical mechanisms undergone by the ipsilateral hip and knee joints during walking. In addition, the compensatory mechanisms displayed by the contralateral limb were also considered. METHODS: Twelve healthy participants walked on an instrumented treadmill at their preferred walking speed. They underwent kinematic and kinetic analysis during four footwear conditions: normal shoes (NORM), a Malleo Immobil Air Walker on the right leg (OTTO), a Rebound® Air Walker on the right leg with (EVEN) and without (OSS) an Evenup Shoelift™ on the contralateral leg. RESULTS: CAM boot wear increased the relative joint contribution to total mechanical work from the ipsilateral hip and knee joints (p < 0.05), which was characterised by increased hip and knee abduction during the swing phase of the gait cycle. EVEN increased the absolute work done and relative contribution of the contralateral limb. CAM boot wear reduced walking speed (p < 0.05), which was partially compensated for during EVEN. SIGNIFICANCE: The increased hip abduction in the ipsilateral leg was likely caused by the increase in effective leg length and limb mass, which could lead to secondary site complications following prolonged CAM boot wear. Although prescribing an even-up walker partially mitigates these compensatory mechanisms, adverse effects to contralateral limb kinematics and kinetics (e.g., elevated knee joint work) should be considered.


Subject(s)
Ankle , Walking , Humans , Kinetics , Walking/physiology , Gait/physiology , Lower Extremity , Ankle Joint/physiology , Knee Joint , Biomechanical Phenomena
3.
J Strength Cond Res ; 37(12): 2417-2422, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37815243

ABSTRACT

ABSTRACT: Lunn, DE, Nicholson, G, Cooke, M, Crespo, R, Robinson, T, Price, RJ, and Walker, J. Discrete hamstring: quadriceps strength ratios do not represent angle-specific ratios in Premier League soccer players. J Strength Cond Res 37(12): 2417-2422, 2023-This study compared angle-specific hamstring:quadriceps (H:Q) ratios with their discrete counterparts during strength testing in professional male soccer players. Twenty-seven professional English Premier League soccer players were recruited for this study (age: 22 ± 4 years; stature: 1.81 ± 0.08 m; body mass: 74.7 ± 6.5 kg). Isokinetic testing of the knee flexors and extensors was conducted concentrically at two angular velocities (60° and 240°·s -1 ) and eccentrically (for the knee flexors only) at 30°·s -1 . Conventional H:Q ratio was calculated as the ratio between peak joint moment in the flexors and extensors at 60°·s -1 . Functional H:Q ratio was calculated as the peak joint moment in the flexors during the eccentric condition and the extensors at 240°·s -1 . Discrete conventional and functional H:Q ratios were 0.56 ± 0.06 and 1.28 ± 0.22, respectively. The residual differences between discrete values and angle-specific residual values were 13.60 ± 6.56% when normalized to the magnitude of the discrete value. For the functional ratios, the normalized residual was 21.72 ± 5.61%. Therefore, neither discrete ratio was representative of angle-specific ratios, although the conventional ratio had lower error overall. Therefore, practitioners should consider H:Q ratio throughout the full isokinetic range of motion, not just the discrete ratio calculated from peak joint moments, when designing and implementing training programs or monitoring injury risk, recovery from injury, and readiness to return to play.


Subject(s)
Hamstring Muscles , Soccer , Humans , Male , Adolescent , Young Adult , Adult , Torque , Quadriceps Muscle , Knee Joint , Muscle Strength
4.
J Arthroplasty ; 35(3): 877-885, 2020 03.
Article in English | MEDLINE | ID: mdl-31699529

ABSTRACT

BACKGROUND: Total hip arthroplasty (THA) implants are routinely tested for their tribological performance through regulatory preclinical wear testing (eg, ISO-14242). The standardized loading conditions defined in these tests consist of simplified waveforms, which do not specifically represent in vivo loads in different groups of patients. The aim of this study is to investigate, through musculoskeletal modeling, patient-specific and activity-related variation in hip contact forces (HCFs) in a large cohort of THA patients during common activities of daily living (ADLs). METHODS: A total of 132 THA patients participated in a motion-capture analysis while performing different ADLs, including walk, fast walk, stair ascent, and descent (locomotor); sit to stand, stand to sit, squat, and lunge (nonlocomotor). HCFs were then calculated using the AnyBody Modeling System and qualitatively compared across all activities. The influence of gender on HCFs was analyzed through statistical parametric mapping analysis. RESULTS: Systematic differences were found in HCF magnitudes and individual components in both locomotor and nonlocomotor ADLs. The qualitative analysis of the ADLs revealed a large range and a large variability in forces experienced at the hip during different activities. Significant differences in the 3-dimensional loading patterns were observed between males and females across most activities. CONCLUSION: THA patients present a large variability in the forces experienced at the hip joint during their daily life. The interpatient variation might partially explain the heterogeneity observed in implant survival rates. A more extensive preclinical implant testing standard under clinically relevant loading conditions has been advocated to better predict and avoid clinical wear problems.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Joint , Activities of Daily Living , Biomechanical Phenomena , Female , Hip Joint/surgery , Humans , Male
5.
J Biomech ; 87: 19-27, 2019 04 18.
Article in English | MEDLINE | ID: mdl-30876738

ABSTRACT

To examine functional differences in total hip replacement patients (THR) when stratified either by age or by functional ability as defined by self-selected walking speed. THR patients and a control group underwent three-dimensional motion analysis under self-selected normal and fast walking conditions. Patients were stratified into five age groups for comparison with existing literature. The THR cohort was also stratified into three functional groups determined by their self-selected gait speed (low function <1SD of total cohort's mean walking speed; high function >1SD; normal function within 1SD). Hip kinematics, ground reaction forces, joint moments and joint powers in all three planes (x-y-z) were analysed. 137 THR and 27 healthy control patients participated. When stratified by age, during normal walking the youngest two age groups walked quicker than the oldest two groups (p < 0.0001) but between-group differences were not consistent across age strata. The differences were diminished under the fast walking condition. When stratified by function, under normal walking conditions, the low function and normal function THR groups had a reduced extension angle (mean = 1.75°, SD = ±7.75, 1.26°â€¯±â€¯7.42, respectively) compared to the control group (-6.07°â€¯±â€¯6.43; p < 0.0001). The low function group had a reduced sagittal plane hip power (0.75 W/kg ±â€¯0.24), reduced flexor (0.60 Nm/kg ±â€¯0.85) and extensor moment (0.51 Nm/kg ±â€¯0.17) compared to controls (p < 0.0001). These differences persisted under the fast walking condition. There were systematic differences between patients when stratified by function, in both walking conditions. Age-related differences were less systematic. Stratifying by biomechanical factors such as gait speed, rather than age, might be more robust for investigating functional differences.


Subject(s)
Arthroplasty, Replacement, Hip , Gait , Hip Joint , Walking Speed , Age Factors , Aged , Aged, 80 and over , Biomechanical Phenomena , Cohort Studies , Female , Hip Joint/physiology , Humans , Kinetics , Male , Middle Aged
6.
PLoS One ; 13(9): e0204109, 2018.
Article in English | MEDLINE | ID: mdl-30222777

ABSTRACT

Musculoskeletal models represent a powerful tool to gain knowledge on the internal forces acting at the joint level in a non-invasive way. However, these models can present some errors associated with the level of detail in their geometrical representation. For this reason, a thorough validation is necessary to prove the reliability of their predictions. This study documents the development of a generic musculoskeletal model and proposes a working logic and simulation techniques for identifying specific model features in need of refinement; as well as providing a quantitative validation for the prediction of hip contact forces (HCF). The model, implemented in the AnyBody Modeling System and based on the cadaveric dataset TLEM 2.0, was scaled to match the anthropometry of a patient fitted with an instrumented hip implant and to reproduce gait kinematics based on motion capture data. The relative contribution of individual muscle elements to the HCF and joint moments was analyzed to identify critical geometries, which were then compared to muscle magnetic resonance imaging (MRI) scans and, in case of inconsistencies, were modified to better match the volumetric scans. The predicted HCF showed good agreement with the overall trend and timing of the measured HCF from the instrumented prosthesis. The average root mean square error (RMSE), calculated for the total HCF was found to be 0.298*BW. Refining the geometries of the muscles thus identified reduced RMSE on HCF magnitudes by 17% (from 0.359*BW to 0.298*BW) over the whole gait cycle. The detailed study of individual muscle contributions to the HCF succeeded in identifying muscles with incorrect anatomy, which would have been difficult to intuitively identify otherwise. Despite a certain residual over-prediction of the final hip contact forces in the stance phase, a satisfactory level of geometrical accuracy of muscle paths has been achieved with the refinement of this model.


Subject(s)
Hip/physiology , Models, Biological , Muscle, Skeletal/anatomy & histology , Muscle, Skeletal/physiology , Biomechanical Phenomena , Gait/physiology , Hip Prosthesis , Humans , Knee Joint/physiology , Male , Middle Aged , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...