Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(5 Pt 2): 056326, 2011 May.
Article in English | MEDLINE | ID: mdl-21728666

ABSTRACT

In this paper, a series of numerical simulations was performed to investigate the pumping performance of electro-osmotic micropumps containing electrode arrays patterned on the upper and lower sides of a microchannel. The simulations have been analyzed with a linear electro-osmotic model based upon the Debye-Hückel theory of the double layer. The potential drop across the diffuse layer is assumed to be less than 25 mV (k(B)T/e), and there is a linear response between the surface charge and the voltage drop across the double layer. The double layer is not resolved but is lumped into effective parameters that are imported from the Debye-Hückel and Stern layers. We examined the effects of the relative positioning of the electrodes in the opposing arrays (i.e., symmetrical or staggered), and the phase lag and the angular frequency of the alternating current (ac) signals applied to the electrodes within the two arrays. A critical height of the microchannel was observed, below which the interactions of the applied electrical potentials on the walls became significant. The optimum pumping effect was obtained when the electrode arrays were symmetrical to one another around the centerline of the channel and were activated by ac potentials with a 0° phase shift. The corresponding angular frequency of the maximum pumping velocity for different phase shifts of the applied ac signals was also determined. Overall, the simulation results presented in this paper provide a useful insight into the optimal design parameters and operating conditions for micropumps containing two arrays of microelectrodes on the microchannel walls.


Subject(s)
Electroosmosis/instrumentation , Electrodes , Hydrodynamics , Models, Theoretical
2.
Biosens Bioelectron ; 21(8): 1644-8, 2006 Feb 15.
Article in English | MEDLINE | ID: mdl-16112854

ABSTRACT

This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.


Subject(s)
Biosensing Techniques/instrumentation , Electrochemistry/instrumentation , Flow Injection Analysis/instrumentation , Microfluidic Analytical Techniques/instrumentation , Biosensing Techniques/methods , Electrochemistry/methods , Equipment Design , Equipment Failure Analysis , Flow Injection Analysis/methods , Microfluidic Analytical Techniques/methods
3.
J Colloid Interface Sci ; 295(2): 551-61, 2006 Mar 15.
Article in English | MEDLINE | ID: mdl-16242138

ABSTRACT

This paper investigates two-dimensional, time-dependent electroosmotic flow driven by an AC electric field via patchwise surface heterogeneities distributed along the micro-channel walls. The time-dependent flow fields through the micro-channel are simulated for various patchwise heterogeneous surface patterns using the backwards-Euler time stepping numerical method. Different heterogeneous surface patterns are found to create significantly different electrokinetic transport phenomena. The transient behavior characteristics of the generated electroosmotic flow are then discussed in terms of the influence of the patchwise surface heterogeneities, the direction of the applied AC electric field, and the velocity of the bulk flow. It is shown that the presence of oppositely charged surface heterogeneities on the micro-channel walls results in the formation of localized flow circulations within the bulk flow. These circulation regions grow and decay periodically in phase with the applied periodic AC electric field intensity. The location and rotational direction of the induced circulations are determined by the directions of the bulk flow velocity and the applied electric field.