1.
J Cardiovasc Magn Reson ; : 101052, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38936803

ABSTRACT

BACKGROUND: In-vivo diffusion tensor CMR (DT-CMR) is an emerging technique for microstructural tissue characterisation in the myocardium. Most studies are performed at 3T, where higher signal to noise ratio (SNR) should benefit this signal starved method. However, a few studies have suggested that DT-CMR is possible at 1.5T, where EPI artefacts may be less severe and 1.5T hardware is more widely available. METHODS: We recruited 20 healthy volunteers and performed mid-ventricular short axis DT-CMR at 1.5 T and 3 T. Acquisitions were performed at peak systole and end-diastole using both stimulated echo acquisition mode (STEAM) and motion compensated spin-echo (MCSE) sequences at matched spatial resolutions. DT-CMR parameters were averaged over the LV and compared between 1.5 T and 3 T sequences using both datasets with and without the blow reference data included. RESULTS: Eleven (1.5T) and 12 (3T) diastolic MCSE acquisitions were rejected as the helix angle (HA) demonstrated <50% normal appearance circumferentially or the acquisition was abandoned due to poor image quality; a maximum of one acquisition was rejected for other datasets. Subjective HA map quality was significantly better at 3T than 1.5T for STEAM (p<0.05), but not for MCSE and other DT-CMR quality measures were consistent with improvements in STEAM at 3T over 1.5T. When blow data was excluded, no significant differences in mean diffusivity were observed between field strengths, but fractional anisotropy was significantly higher at 1.5T than 3T for STEAM systole (p<0.05). Absolute second eigenvector orientation (E2A, sheetlet angle) was significantly higher at 1.5T than 3T for MCSE systole and STEAM diastole, but significantly lower for STEAM systole (all p<0.05). Transmural HA distribution was less steep at 1.5T than 3T for STEAM diastole data (p<0.05). SNR in the blow images was higher at 3T than 1.5T for all acquisitions (p<0.05). CONCLUSION: While 3T provides benefits in terms of SNR, both STEAM and MCSE can be performed at 1.5T. However, MCSE is unreliable in diastole at both field strengths and STEAM benefits from the improved SNR at 3T over 1.5T. Future clinical research studies may be able to leverage the wider availability of 1.5T CMR hardware where MCSE acquisitions are desirable.

2.
Magn Reson Med ; 91(6): 2403-2416, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38263908

ABSTRACT

PURPOSE: The study aims to assess the potential of referenceless methods of EPI ghost correction to accelerate the acquisition of in vivo diffusion tensor cardiovascular magnetic resonance (DT-CMR) data using both computational simulations and data from in vivo experiments. METHODS: Three referenceless EPI ghost correction methods were evaluated on mid-ventricular short axis DT-CMR spin echo and STEAM datasets from 20 healthy subjects at 3T. The reduced field of view excitation technique was used to automatically quantify the Nyquist ghosts, and DT-CMR images were fit to a linear ghost model for correction. RESULTS: Numerical simulation showed the singular value decomposition (SVD) method is the least sensitive to noise, followed by Ghost/Object method and entropy-based method. In vivo experiments showed significant ghost reduction for all correction methods, with referenceless methods outperforming navigator methods for both spin echo and STEAM sequences at b = 32, 150, 450, and 600 smm - 2 $$ {\mathrm{smm}}^{-2} $$ . It is worth noting that as the strength of the diffusion encoding increases, the performance gap between the referenceless method and the navigator-based method diminishes. CONCLUSION: Referenceless ghost correction effectively reduces Nyquist ghost in DT-CMR data, showing promise for enhancing the accuracy and efficiency of measurements in clinical practice without the need for any additional reference scans.


Subject(s)
Echo-Planar Imaging , Image Processing, Computer-Assisted , Humans , Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Signal-To-Noise Ratio , Phantoms, Imaging , Magnetic Resonance Spectroscopy , Artifacts , Brain , Algorithms