Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrasound Med Biol ; 27(3): 409-17, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11369127

ABSTRACT

A method to measure transverse blood flow, based on the correlation between consecutive radiofrequency (RF) signals, has been introduced. This method was validated for an intravascular (IVUS) rotating single element catheter. Currently, we are implementing the method for an IVUS array transducer catheter. The decorrelation characteristics during transverse blood flow using the IVUS array catheter were investigated using computer modeling. Before this, blood was simulated as a collection of randomly located point scatterers and, by moving this scattering medium transversely across the acoustical beam, blood flow was simulated. This paper presents a more realistic scattering media by simulating aggregates of red blood cells (RBCs) as strings of point scatterers. Three configurations of aggregates of RBCs were simulated. First, aggregates of RBCs were strings with different lengths and parallel to the catheter axis. Second, the strings were with a fixed length and angles of plus or minus 45 degrees with respect to the catheter axis. Third, the strings were with different lengths and random angles ranging from -45 degrees to + 45 degrees. The decorrelation characteristics for these configurations of aggregates of RBCs were investigated and compared with point scatterers. For the aggregates of RBCs parallel to the catheter axis, the decorrelation rate became slower when the aggregate length was increased. RBC aggregations with fixed and random lengths and angles resulted in a decorrelation rate that approaches the decorrelation pattern from point scatterers. Results suggests that the presence of aggregates of RBCs will probably not affect the measurements of transverse blood flow using a decorrelation-based method and an IVUS array catheter.


Subject(s)
Blood Flow Velocity , Erythrocyte Aggregation , Ultrasonography, Interventional , Catheterization , Computer Simulation , Humans , Ultrasonography, Interventional/instrumentation
2.
Article in English | MEDLINE | ID: mdl-18238704

ABSTRACT

In recent years, a new method to measure transverse blood flow based on the decorrelation of radio frequency (RF) signals has been introduced. In this paper, we investigated the decorrelation characteristics of transverse blood flow measurement using an intravascular ultrasound (IVUS) array catheter by means of computer modeling. Blood was simulated as a collection of randomly located point scatterers. Moving this scattering medium transversally across the acoustical beam represented flow. First-order statistics were evaluated, and the signal-to-noise ratio from the signals was measured. The correlation coefficient method was used to present the results. The decorrelation patterns for RF and for RF-envelope signals were studied. The decorrelation patterns from the RF signals were in good agreement with those obtained from theoretical beam profiles. This agreement suggests that the decorrelation properties of an IVUS array catheter for measuring quantitative transverse blood flow can be assessed by measuring the ultrasound beam. A line of point scatterers, moved transversally across the acoustical beam (line spread function), can determine this decorrelation behaviour.

SELECTION OF CITATIONS
SEARCH DETAIL
...