Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 130
Filter
1.
Resuscitation ; 185: 109685, 2023 04.
Article in English | MEDLINE | ID: mdl-36610503

ABSTRACT

BACKGROUND: Efficient ventilation is important during cardiopulmonary resuscitation (CPR). Nevertheless, there is insufficient knowledge on how the patient's position affects ventilatory parameters during mechanically assisted CPR. We studied ventilatory parameters at different positive end-expiratory pressure (PEEP) levels and when using an inspiratory impedance valve (ITD) during horizontal and head-up CPR (HUP-CPR). METHODS: In this human cadaver experimental study, we measured tidal volume (VT) and pressure during CPR at different randomized PEEP levels (0, 5 or 10 cmH2O) or with an ITD. CPR was performed, in the following order: horizontal (FLAT), at 18° and then at 35° head-thorax elevation. During the inspiratory phase we measured the net tidal volume (VT) adjusted to predicted body weight (VTPBW), reversed airflow (RAF), and maximum and minimum airway pressure (Pmax and Pmin). RESULTS: Using ten thawed fresh-frozen cadavers we analyzed the inspiratory phase of 1843 respiratory cycles, 229 without CPR and 1614 with CPR. In a mixed linear model, thoracic position and PEEP significantly impacted VTPBW (p < 0.001 for each), and the insufflation time, thoracic position and PEEP significantly affected the RAF (p < 0.001 for each) and Pmax (p < 0.001). For Pmin, only PEEP was significant (p < 0.001). In subgroup analysis, at 35° VTPBW and Pmax were significantly reduced compared with the flat or 18° position. CONCLUSION: When using mechanical ventilation during CPR, it seems that the PEEP level and patient position are important determinants of respiratory parameters. Moreover, tidal volume seems to be lower when the thorax is positioned at 35°.


Subject(s)
Cardiopulmonary Resuscitation , Respiration, Artificial , Humans , Positive-Pressure Respiration , Lung , Tidal Volume , Thorax
2.
Curr Opin Crit Care ; 11(3): 204-11, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15928467

ABSTRACT

PURPOSE OF REVIEW: Despite a more widespread knowledge of basic cardiopulmonary resuscitation maneuvers in the community, the survival rate for patients with cardiac arrest has remained essentially unchanged in the past 30 years. Over the past few decades, many different compression-ventilation ratios have been studied in terms of best coronary and cerebral oxygen delivery, restoration of spontaneous circulation, and neurologic outcome. This article summarizes the recent evidence presented at the International Consensus on Resuscitation Science in January 2005. RECENT FINDINGS: Recent data from animal and mathematical models suggest a move to a higher compression-ventilation ratio to maximize coronary and cerebral oxygen delivery during cardiac arrest and long-term neurologic outcome. Prospective randomized human data on alternative compression-ventilation ratios are missing and new evidence seems to indicate the inadequacy of both lay and professional rescuers in providing chest compression and ventilating the victim in cardiac arrest. Finally, observational and animal studies highlight the hidden danger of inadvertent hyperventilation during advanced cardiac life support as a reduction of both coronary and perfusion pressure secondary to increased intrathoracic pressure and decreased venous return. SUMMARY: The optimal compression-ventilation ratio is still unknown and the best tradeoff between oxygenation and organ perfusion during cardiopulmonary resuscitation is probably different for each patient and scenario. A discrepancy between what is recommended by the current guidelines and the 'real world' of cardiopulmonary resuscitation has resulted in a near flat survival rate from cardiac arrest in the past few years.


Subject(s)
Cardiopulmonary Resuscitation/methods , Pulmonary Ventilation , Cardiopulmonary Resuscitation/standards , Heart Arrest/therapy , Humans , Models, Animal , Models, Statistical , Oxygen Consumption , Survival Rate , Time Factors , United States
4.
Circulation ; 104(14): 1651-6, 2001 Oct 02.
Article in English | MEDLINE | ID: mdl-11581144

ABSTRACT

BACKGROUND: The purpose of this study was to investigate the effects of vasopressin versus epinephrine, and both drugs combined, in a porcine model of simulated adult asphyxial cardiac arrest. METHODS AND RESULTS: At approximately 7 minutes after the endotracheal tube had been clamped, cardiac arrest was present in 24 pigs and remained untreated for another 8 minutes. After 4 minutes of basic life support cardiopulmonary resuscitation, pigs were randomly assigned to receive, every 5 minutes, either epinephrine (45, 200, or 200 microgram/kg; n=6); vasopressin (0.4, 0.8, or 0.8 U/kg; n=6); or epinephrine combined with vasopressin (high-dose epinephrine/vasopressin combination, microgram/kg and U/kg: 45/0.4, 200/0.8, or 200/0.8; n=6; optimal-dose epinephrine/vasopressin combination, 45/0.4, 45/0.8, or 45/0.8; n=6). Mean+/-SEM coronary perfusion pressure was significantly (P<0.05) higher 90 seconds after high- or optimal-dose epinephrine/vasopressin combinations versus vasopressin alone and versus epinephrine alone (37+/-10 versus 25+/-7 versus 19+/-8 versus 6+/-3 mm Hg; 42+/-6 versus 40+/-5 versus 21+/-5 versus 14+/-6 mm Hg; and 39+/-6 versus 37+/-4 versus 9+/-3 versus 12+/-4 mm Hg, respectively). Six of 6 high-dose, 6 of 6 optimal-dose vasopressin/epinephrine combination, 0 of 6 vasopressin, and 1 of 6 epinephrine pigs had return of spontaneous circulation (P<0.05). CONCLUSIONS: Epinephrine combined with vasopressin, but not epinephrine or vasopressin alone, maintained elevated coronary perfusion pressure during cardiopulmonary resuscitation and resulted in significantly higher survival rates in this adult porcine asphyxial model.


Subject(s)
Cardiopulmonary Resuscitation/methods , Heart Arrest/drug therapy , Vasopressins/pharmacology , Animals , Asphyxia/etiology , Blood Pressure/drug effects , Drug Combinations , Epinephrine/pharmacology , Heart/physiopathology , Heart Arrest/physiopathology , Hemodynamics/drug effects , Kinetics , Myocardial Reperfusion , Survival Rate , Swine
5.
Crit Care Med ; 29(8): 1587-92, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11505132

ABSTRACT

OBJECTIVE: The intraosseous route is an emergency alternative for the administration of drugs and fluids if vascular access cannot be established. However, in hemorrhagic shock or after vasopressors are given during resuscitation, bone marrow blood flow may be decreased, thus impairing absorption of intraosseously administered drugs. In this study, we evaluated the effects of vasopressin vs. high-dose epinephrine in hemorrhagic shock and cardiac arrest on bone marrow blood flow. DESIGN: Prospective, randomized laboratory investigation that used an established porcine model for measurement of hemodynamic variables and organ blood flow. SETTING: University hospital laboratory. SUBJECTS: Fourteen pigs weighing 30 +/- 3 kg. INTERVENTIONS: Radiolabeled microspheres were injected to measure bone marrow blood flow during a prearrest control period and during hypovolemic shock produced by rapid hemorrhage of 35% of the estimated blood volume. In the second part of the study, ventricular fibrillation was induced; after 4 mins of untreated cardiac arrest and 4 mins of standard cardiopulmonary resuscitation, a bolus dose of either 200 microg/kg epinephrine (n = 6) or 0.8 units/kg vasopressin (n = 6) was administered. Defibrillation was attempted 2.5 mins after drug administration, and blood flow was assessed again at 5 and 30 mins after successful resuscitation. MEASUREMENTS AND MAIN RESULTS: Mean +/- sem bone marrow blood flow decreased significantly during induction of hemorrhagic shock from 14.4 +/- 4.1 to 3.7 +/- 1.8 mL.100 g-1.min-1 in the vasopressin group and from 18.2 +/- 4.0 to 5.2 +/- 1.0 mL.100 g-1.min-1 in the epinephrine group (p =.025 in both groups). Five minutes after return of spontaneous circulation, mean +/- sem bone marrow blood flow was 3.4 +/- 1.1 mL.100 g-1.min-1 after vasopressin and 0.1 +/- 0.03 mL.100 g-1.min-1 after epinephrine (p =.004 for vasopressin vs. epinephrine). At the same time, bone vascular resistance was significantly (p =.004) higher in the epinephrine group when compared with vasopressin (1455 +/- 392 vs. 43 +/- 19 mm Hg. mL-1.100 g.min, respectively). CONCLUSIONS: Bone blood flow responds actively to both the physiologic stress response of hemorrhagic shock and vasopressors given during resuscitation after hypovolemic cardiac arrest. In this regard, bone marrow blood flow after successful resuscitation was nearly absent after high-dose epinephrine but was maintained after high-dose vasopressin. These findings emphasize the need for pressurized intraosseous infusion techniques, because bone marrow blood flow may not be predictable during hemorrhagic shock and drug therapy.


Subject(s)
Bone Marrow/blood supply , Epinephrine/therapeutic use , Heart Arrest/etiology , Shock/drug therapy , Vasoconstrictor Agents/therapeutic use , Vasopressins/therapeutic use , Animals , Bone Marrow/drug effects , Female , Hemodynamics , Infusions, Intraosseous , Microspheres , Resuscitation , Shock/complications , Swine
6.
Anesth Analg ; 93(3): 649-55, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11524335

ABSTRACT

To improve the efficiency of standard cardiopulmonary resuscitation (CPR), we evaluated the potential value of impeding respiratory gas exchange selectively during the decompression phase of standard CPR in a porcine model of ventricular fibrillation. After 6 min of untreated cardiac arrest, anesthetized farm pigs weighing 30 kg were randomized to be treated with either standard CPR with a sham valve (n = 11) or standard CPR plus a functional inspiratory impedance threshold valve (ITV(TM)) (n = 11). Coronary perfusion pressure (CPP) (diastolic aortic minus right atrial pressure) was the primary endpoint. Vital organ blood flow was assessed with radiolabeled microspheres after 6 min of CPR, and defibrillation was attempted 11 min after starting CPR. After 2 min of CPR, mean +/- SEM CPP was 14 +/- 2 mm Hg with the sham valve versus 20 +/- 2 mm Hg in the ITV group (P < 0.006). Significantly higher CPPs were maintained throughout the study when the ITV was used. After 6 min of CPR, mean +/- SEM left ventricular and global cerebral blood flows were 0.10 +/- 0.03 and 0.19 +/- 0.03 mL. min(-1). g(-1) in the Control group versus 0.19 +/- 0.03 and 0.26 +/- 0.03 mL. min(-1). g(-1) in the ITV group, respectively (P < 0.05). Fifteen minutes after successful defibrillation, 2 of 11 animals were alive in the Control group versus 6 of 11 in the ITV group (not significant). In conclusion, use of an inspiratory impedance valve during standard CPR resulted in a marked increase in CPP and vital organ blood flow after 6 min of cardiac arrest.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Heart Arrest/therapy , Respiration, Artificial/instrumentation , Animals , Blood Gas Analysis , Hemodynamics/physiology , Regional Blood Flow/physiology , Respiratory Mechanics/physiology , Swine
8.
Curr Opin Crit Care ; 7(3): 157-69, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11436522

ABSTRACT

Epinephrine use during cardiopulmonary resuscitation (CPR) is controversial because of its receptor-mediated adverse effects such as increased myocardial oxygen consumption, ventricular arrhythmias, ventilation-perfusion defect, postresuscitation myocardial dysfunction, ventricular arrhythmias, and cardiac failure. In the CPR laboratory, vasopressin improved vital organ blood flow, cerebral oxygen delivery, resuscitability, and neurologic recovery more than did epinephrine. In patients with out-of-hospital ventricular fibrillation, a larger proportion of patients treated with vasopressin survived 24 hours than did patients treated with epinephrine. Currently, a large trial of out-of-hospital cardiac arrest patients being treated with vasopressin versus epinephrine is ongoing in Germany, Austria, and Switzerland. The new international CPR guidelines recommend 40 U vasopressin intravenously, and 1 mg epinephrine intravenously, as equally effective for the treatment of adult patients in ventricular fibrillation; however, no recommendation for vasopressin has been made to date for adult patients with asystole and pulseless electrical activity, or in children, because of lack of clinical data. When adrenergic vasopressors were unable to maintain arterial blood pressure in patients with vasodilatory shock, continuous infusions of vasopressin (0.04-0.10 U/min) stabilized cardiocirculatory parameters and even ensured weaning from catecholamines.


Subject(s)
Arginine Vasopressin/therapeutic use , Cardiopulmonary Resuscitation , Heart Arrest/drug therapy , Shock/drug therapy , Vasodilation/physiology , Epinephrine/therapeutic use , Evidence-Based Medicine , Humans , Shock/physiopathology , United States , Vasoconstriction/physiology
9.
Curr Opin Crit Care ; 7(3): 170-5, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11436523

ABSTRACT

Challenged by the continued high mortality rates for patients in cardiac arrest, the American Heart Association and the European Resuscitation Council developed a new set of guidelines in 2000 to help advance several new and promising cardiopulmonary resuscitation (CPR) techniques and devices. This is the first time these organizations have taken such a bold move, in part because of the poor results with standard closed-chest cardiac massage. The new techniques, interposed abdominal counterpulsation and active compression decompression CPR, each provide greater blood flow to the vital organs in animal models of CPR and lead to higher blood pressures in patients in cardiac arrest. In some clinical studies, both techniques have resulted in a significant increase in survival after cardiac arrest in comparison with standard CPR. Three of the four new CPR devices that were recommended in the new guidelines also provide superior vital organ blood flow and increased blood pressures in comparison with standard CPR. The three devices that improve the efficiency of CPR are the circumferential vest, an active compression decompression CPR device, and an inspiratory impedance valve used in combination with the active compression decompression CPR device. The fourth device type, one that compresses the thorax using an automated mechanical piston compression mechanism, was recommended to reduce the number of personnel required to perform CPR. However, no studies on the automated mechanical compression devices have showed an improvement in hemodynamic variables or survival in comparison with standard CPR. Taken together, these new technologies represent an important step forward in the evolution of CPR from a pair of hands to devices designed to enhance CPR efficiency. Each of these advances is described, and the recent literature about each of them is reviewed.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Cardiopulmonary Resuscitation/methods , Cardiopulmonary Resuscitation/trends , Efficiency , Equipment Design , Guidelines as Topic , Humans , United States
11.
Europace ; 3(2): 159-63, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11333057

ABSTRACT

A 30-year-old Caucasian male was referred for evaluation of a 2-year history of recurrent post-exertion lightheadedness and near syncopal spells in the setting of a family history of unexplained sudden cardiac death. Cardiac evaluation demonstrated normal heart structure, but the 12-lead surface ECG was suggestive of but not diagnostic of Brugada syndrome. An exercise stress test reproduced the patient's usual symptoms during the recovery period, and was consistent with a typical vasovagal faint. The same symptoms were observed during a head-up tilt table test. However, given the family history and ECG, pharmacological testing with procainamide, isoprenaline and metoprolol, as well as programmed ventricular stimulation, were undertaken. Pharmacological provocation further supported a diagnosis of Brugada syndrome, whereas programmed ventricular stimulation was considered non-diagnostic regarding ventricular tachyarrhythmia susceptibility. Consequently, despite ECG and pharmacological findings suggestive of Brugada syndrome, there appeared to be sufficient evidence to believe that this patient's symptoms were the result of neurally mediated syncope and not due to ventricular tachyarrhythmias. The patient was treated with midodrine, and has remained symptom-free for 16 months. Thus, given the frequency with which vasovagal syncope occurs in young patients, its occurrence is not unexpected in individuals with concomitant diagnoses such as Brugada syndrome. In as much as current recommendations favour implantable defibrillators in symptomatic Brugada syndrome, the identification of other causes of syncope in such patients poses an uncomfortable, and currently unsettled dilemma.


Subject(s)
Defibrillators, Implantable , Syncope, Vasovagal/prevention & control , Ventricular Fibrillation/therapy , Adult , Bundle-Branch Block/diagnosis , Bundle-Branch Block/genetics , Bundle-Branch Block/therapy , Diagnosis, Differential , Electrocardiography , Exercise Test , Humans , Male , Midodrine/therapeutic use , Syncope, Vasovagal/etiology , Syndrome , Tilt-Table Test , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/genetics
12.
Anesth Analg ; 92(6): 1499-504, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11375833

ABSTRACT

Exogenous vasopressin is a promising vasopressor when blood pressure is critically threatened, but the role of endogenous vasopressin during cardiopulmonary resuscitation (CPR) is unknown. We assessed the role of endogenous versus exogenous vasopressin in a porcine open chest CPR model. Seven minutes before induction of cardiac arrest, seven pigs received 10 microg/kg of a selective vasopressin V(1)-receptor-antagonist (Blocked Vasopressin group); another 12 pigs in two groups received saline administration only. After 4 min of untreated ventricular fibrillation followed by 3 min of basic life support CPR, six animals received 0.8 U/kg vasopressin (Exogenous Vasopressin group), whereas the blocked vasopressin group (n = 7), and the remaining six animals received saline placebo only (Endogenous Vasopressin group). Defibrillation was attempted after 14 min of CPR. During basic life support CPR, left ventricular myocardial blood flow was significantly (P < 0.05) decreased in the Blocked Vasopressin group compared with the Exogenous Vasopressin group and Endogenous Vasopressin group (42 +/- 5 compared with 64 +/- 6 and 66 +/- 6 mL x min(-1) x 100g(-1)). Left ventricular myocardial blood flow was significantly decreased in the Blocked Vasopressin group versus Exogenous Vasopressin group versus Endogenous Vasopressin group 90 s and 5 min after drug administration, respectively (38 +/- 4 and 27 +/- 3 vs 145 +/- 32 and 110 +/- 12 vs 62 +/- 4 and 56 +/- 6 mL x min(-1) x 100g(-1), respectively). None of seven Blocked Vasopressin animals, six of six Exogenous Vasopressin pigs, and six of six Endogenous Vasopressin swine had return of spontaneous circulation after 14 min of cardiac arrest including 10 min of CPR (P < 0.05). In conclusion, pigs with blocked endogenous vasopressin had poor coronary perfusion pressure and left ventricular myocardial blood flow during open chest CPR, and could not be successfully resuscitated. All pigs with effective endogenous vasopressin or pigs with effective endogenous vasopressin and additional exogenous vasopressin had good left ventricular myocardial blood flow during experimental CPR, and survived the 1-h postresuscitation phase. We conclude that endogenous vasopressin is an adjunct vasopressor to epinephrine and may serve as a back-up regulator to maintain cardiocirculatory homeostasis.


Subject(s)
Cardiopulmonary Resuscitation , Hemodynamics/drug effects , Vasopressins/pharmacology , Vasopressins/physiology , Animals , Coronary Circulation , Epinephrine/blood , Heart Arrest/physiopathology , Myocardium/metabolism , Swine , Ventricular Function, Left/drug effects
16.
Anesth Analg ; 92(4): 967-74, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11273935

ABSTRACT

UNLABELLED: The use of an inspiratory impedance threshold valve (ITV) during active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) improves perfusion pressures, and vital organ blood flow. We evaluated the effects of positive end-expiratory pressure (PEEP) on gas exchange, and coronary perfusion pressure gradients during ACD + ITV CPR in a porcine cardiac arrest model. All animals received pure oxygen intermittent positive pressure ventilation (IPPV) at a 5:1 compression-ventilation ratio during ACD + ITV CPR. After 8 min, pigs were randomized to further IPPV alone (n = 8), or IPPV with increasing levels of PEEP (n = 8) of 2.5, 5.0, 7.5, and 10 cm H(2)O for 4 consecutive min each, respectively. Mean +/- SEM arterial oxygen partial pressure decreased in the IPPV group from 150 +/- 30 at baseline after 8 min of CPR to 110 +/- 25 torr at 24 min, but increased in the PEEP group from 115 +/- 15 to 170 +/- 25 torr with increasing levels of PEEP (P <0.02 for comparisons within groups). Mean +/- SEM diastolic aortic minus diastolic left ventricular pressure gradient was significantly (P < 0.001) higher after the administration of PEEP (24 +/- 0 vs 17 +/- 1 mm Hg with 5 cm H(2)O of PEEP, and 26 +/- 0 vs 17 +/- 1 mm Hg with 10 cm H(2)O of PEEP), whereas the diastolic aortic minus right atrial pressure gradient (coronary perfusion pressure) was comparable between groups. Furthermore, systolic aortic pressures were significantly (P < 0.05) higher with 10 cm H(2)O of PEEP when compared with IPPV alone (68 +/- 0 vs 59 +/- 2 mm Hg). In conclusion, when CPR was performed with devices designed to improve venous return to the chest, increasing PEEP levels improved oxygenation. Moreover, PEEP significantly increased the diastolic aortic minus left ventricular gradient and did not affect the decompression phase aortic minus right atrial pressure gradient. These data suggest that PEEP reduces alveolar collapse during ACD + ITV CPR, thus leading to an increase in indirect myocardial compression. IMPLICATIONS: Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation improves perfusion pressures, and vital organ blood flow during cardiac arrest. Increasing levels of positive end-expiratory pressure during performance of active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve improves oxygenation, and increases the diastolic aortic-left ventricular pressure gradient and systolic arterial blood pressure.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Decompression/instrumentation , Positive-Pressure Respiration/instrumentation , Air Pressure , Animals , Cardiac Output/physiology , Coronary Circulation/physiology , Female , Pulmonary Alveoli/physiology , Pulmonary Circulation/physiology , Pulmonary Gas Exchange/physiology , Swine , Tidal Volume/physiology , Ventricular Fibrillation/physiopathology
17.
Crit Care Med ; 28(11 Suppl): N207-9, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11098948

ABSTRACT

In an effort to improve the efficiency of cardiopulmonary resuscitation (CPR), a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the chest decompression phase. This new device enhances negative intrathoracic pressure during chest wall recoil or the decompression phase, leading to improved vital organ perfusion during both standard CPR and active compression-decompression CPR. With active compression-decompression CPR, addition of the impedance threshold valve results in sustained diastolic pressures of >55 mm Hg in patients in cardiac arrest. The new valve shows promise for patients in asystole or shock refractory ventricular fibrillation, when enhanced return of blood flow to the chest is needed to "prime the pump." The potential long-term benefits of this new valve remain under study.


Subject(s)
Airway Resistance , Cardiopulmonary Resuscitation/instrumentation , Animals , Disease Models, Animal , Equipment Design , Hemodynamics , Humans , Masks , Swine , Thorax/blood supply , Ventricular Fibrillation/therapy
18.
Anesth Analg ; 91(3): 627-34, 2000 Sep.
Article in English | MEDLINE | ID: mdl-10960389

ABSTRACT

UNLABELLED: Survival after hypovolemic shock and cardiac arrest is dismal with current therapies. We evaluated the potential benefits of vasopressin versus large-dose epinephrine in hemorrhagic shock and cardiac arrest on vital organ perfusion, and the likelihood of resuscitation. In 18 pigs, 35% of the estimated blood volume was withdrawn over 15 min and ventricular fibrillation was induced 5 min later. After 4 min of cardiac arrest and 4 min of standard cardiopulmonary resuscitation, a bolus dose of either 200 microg/kg epinephrine (n = 7), 0.8 unit/kg vasopressin (n = 7), or saline placebo (n = 4) was administered in a blinded, randomized manner. Defibrillation was attempted 2.5 min after drug administration, and all animals were subsequently observed for 1 h without further intervention. Spontaneous circulation was restored in 7 of 7 vasopressin animals, in 6 of 7 epinephrine pigs, and in 0 of 4 placebo swine. At 5 and 30 min after return of spontaneous circulation, median (minimum and maximum) renal blood flow after epinephrine was 2 (0-31), and 2 (0-48) mL. 100 g(-1). min(-1), respectively; and after vasopressin 96 (12-161), and 44 (16-105) mL. 100 g(-1). min(-1), respectively (P: <.01 between groups). Epinephrine animals developed a profound metabolic acidosis by 15 min after return of spontaneous circulation (mean arterial pH, 7.11 +/- 0.01), and by 60 min all epinephrine-treated animals had died. The vasopressin pigs had (P: = 0.015) less acidosis (pH = 7.26+/-0. 04) at corresponding time points, and all survived > or =55 min (P: < 0. 01). In conclusion, treatment of hypovolemic cardiac arrest with vasopressin, but not with large-dose epinephrine or saline placebo, resulted in sustained vital organ perfusion, less metabolic acidosis, and prolonged survival. Based on these findings, clinical evaluation of vasopressin during hypovolemic cardiac arrest may be warranted. IMPLICATIONS: The chances of surviving cardiac arrest in hemorrhagic shock are considered dismal without adequate fluid replacement. However, treatment of hypovolemic cardiac arrest with vasopressin, but not with large-dose epinephrine or saline placebo, resulted in sustained vital organ perfusion and prolonged survival in an animal model of suspended infusion therapy.


Subject(s)
Heart Arrest/drug therapy , Shock/drug therapy , Vasopressins/therapeutic use , Animals , Blood Gas Analysis , Blood Pressure/drug effects , Blood Pressure/physiology , Cardiopulmonary Resuscitation , Coronary Circulation/drug effects , Female , Heart Arrest/etiology , Heart Arrest/mortality , Microspheres , Regional Blood Flow/drug effects , Regional Blood Flow/physiology , Shock/complications , Shock/mortality , Survival Analysis , Swine
19.
Crit Care Med ; 28(8): 2915-20, 2000 Aug.
Article in English | MEDLINE | ID: mdl-10966271

ABSTRACT

OBJECTIVE: Especially in pediatric patients with severe hypothermia, intraosseous access may be more readily available than intravascular access during an early phase of treatment and therefore, may be helpful to optimize management. The purpose of this study was to determine whether intraosseous blood gases are comparable with arterial, mixed venous, and sagittal sinus blood gases during different degrees of hypothermia. DESIGN: Prospective, descriptive laboratory investigation using a porcine model. SETTING: University hospital laboratory. SUBJECTS: Twelve anesthetized, 12- to 16-wk-old domestic pigs weighing 30-35 kg. INTERVENTIONS: Volume-controlled ventilated animals were instrumented with arterial, pulmonary artery, sagittal sinus, and 16-gauge intraosseous catheters. Blood samples were obtained from each site every 15 mins during surface cooling with crushed ice until mean +/- SEM core temperature decreased from 38.5+/-0.1 degrees C [101.3+/-0.2 degrees F] to 27+/-0.5 degrees C [80.5+/-0.9 degrees F] over 2 hrs. MEASUREMENTS AND MAIN RESULTS: Intraindividual correlation of Pco2 and pH values were determined as the difference (delta) between intraosseous and reference blood samples. With hypothermia, absolute values of Pco2 decreased and pH increased in samples from all sites. At 27 degrees C, intraosseous--arterial delta P(CO2) and delta pH (mean +/- 95% confidence intervals) were 2.6+/-10.6 torr [0.35+/-1.4 kPa] and -0.11+/-0.07 units; intraosseous - mixed venous were 0.4+/-12.2 torr [0.05+/-1.6 kPa] and -0.06+/-0.08 units; and intraosseous - sagittal sinus were -7.3+/-16 torr [-0.97+/-2.1 kPa] and 0.001+/-0.14 units, respectively. Intraosseous Pco2 was not comparable to end-tidal values (deltaP(CO2) 17.4+/-14.6 torr [2.3+/-1.9 kPa]), and intraosseous lactate did not correlate with arterial, mixed venous, or sagittal sinus values. CONCLUSIONS: During hypothermia, intraosseous P(CO2) values were predictable for mixed venous Pco2 and arterial P(CO2). Intraosseous pH values also correlated with mixed venous and sagittal sinus blood samples. Accordingly, interpretation of blood gas values obtained from bone marrow aspirates may be helpful to adjust ventilation and optimize fluid and drug therapy during the early treatment of patients with severe hypothermia.


Subject(s)
Blood Gas Analysis/methods , Bone and Bones/chemistry , Hypothermia/blood , Animals , Prospective Studies , Swine
20.
Jpn J Pharmacol ; 82(2): 150-4, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10877534

ABSTRACT

m-(Iodobenzyl)trozamicol (MIBT) is a recently discovered vesamicol analogue. It has been shown that radiolabelled [125I]MIBT can be used as a marker of cholinergic innervation in the heart as well as in the brain. The purpose of this study was to analyze the direct effects of MIBT on the atrioventricular and intraventricular conduction in addition to the coronary blood flow using the canine isolated, blood-perfused atrioventricular node preparation. Intracoronary administration of MIBT suppressed the atrioventricular and intraventricular conduction, while it increased the coronary blood flow. The effect and duration of action on the intraventricular conduction was less pronounced compared with other effects. Moreover, the doses of MIBT needed to cause negative dromotropic and coronary vasodilator effects in this study was much greater than those needed for imaging the cardiac cholinergic innervation. Pretreatment of the preparations with a muscarinic receptor antagonist, atropine, did not block these effects of MIBT, suggesting that MIBT may possess muscarinic receptor-independent ion channel activity in the cardiac conduction system and coronary arteries.


Subject(s)
Atrioventricular Node/drug effects , Cholinergic Antagonists/pharmacology , Iodobenzenes/pharmacology , Piperidines/pharmacology , Receptors, Cholinergic/analysis , Animals , Atrioventricular Node/physiology , Atropine/pharmacology , Coronary Circulation/drug effects , Dogs , Dose-Response Relationship, Drug , Perfusion
SELECTION OF CITATIONS
SEARCH DETAIL
...