Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Vet Sci ; 9(7)2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35878327

ABSTRACT

The aim of this study is to report the results and to review the outcome of 14 cases of Y-T humeral fractures repair using paired polyaxial locking system (PAX) plates through a combined medial and lateral approach. Fourteen consecutive dogs, with traumatic humeral Y-T fractures, met the inclusion criteria. This study includes signalment, preoperative radiographs, type of implants, radiographic bone healing assessment, complications, range of motion (ROM) of the elbow and limb function evaluated at 120 days after surgery. Postoperative radiographs revealed adequate anatomic reconstruction, and in all cases, bone healing has been achieved. No implant failure was observed. Functional outcome was excellent in 7 dogs (no lameness and preserved ROM), good in 4 (slight lameness and moderate ROM reduction) and discrete in 2 (mild lameness and severe ROM reduction). Complications were encountered in 2/14 patients with implant-associated infection resolved after long-term antibiotic treatment and implant removal. The PAX system is shown to be a valid alternative for the treatment of Y-T humeral fractures, offering the benefit of polyaxial insertion of locking screws. The possibility of angle locking screws is helpful in the distal humeral bicondylar fractures, providing additional options for screw placement in juxtarticular fractures, avoiding fracture lines or other implants.

2.
Vet Comp Orthop Traumatol ; 30(3): 200-208, 2017 May 10.
Article in English | MEDLINE | ID: mdl-28474728

ABSTRACT

OBJECTIVES: The aim of the study was to describe the differences in pelvic limb alignment between healthy purebred English Bulldogs and those with medial patellar luxation through the measurement of femoral and tibial angles on computed tomography images in multiplanar reconstruction modality (MPR-CT). METHODS: Twenty-one purebred English Bulldogs were included and divided into two groups: one including healthy dogs (15 limbs) and the other including those with medial patellar luxation (24 limbs). Three different observers used MPR-CT to measure the following angles: anatomical lateral proximal femoral angle (aLPFA), anatomical lateral distal femoral angle (aLDFA), mechanical lateral proximal femoral angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), angle of inclination of the femoral neck (AI), angle of anteversion (AA), mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), mechanical caudal distal tibial angle (mCdDTA), mechanical caudal proximal tibial angle (mCdPTA), and the tibial torsion angle (TTA). A Mann-Whitney U test was used to compare each variable in both groups. RESULTS: The values for aLDFA and mLDFA in the medial patellar luxation population were significantly increased compared to healthy subjects (p <0.05). No significant differences were observed for the other variables. CLINICAL SIGNIFICANCE: In our population, an increased distal femoral varus was associated with medial patellar luxation. Our results could be useful to determine whether or not angular deformity of the femur is present and help determine the degree of correction necessary to restore alignment.


Subject(s)
Dog Diseases/physiopathology , Patellar Dislocation/veterinary , Tomography, X-Ray Computed/veterinary , Animals , Biomechanical Phenomena , Dog Diseases/diagnostic imaging , Dogs , Femur/anatomy & histology , Femur Neck , Hindlimb , Patellar Dislocation/diagnostic imaging , Patellar Dislocation/physiopathology , Pelvis , Tibia
3.
Vet Comp Orthop Traumatol ; 30(3): 172-177, 2017 May 22.
Article in English | MEDLINE | ID: mdl-28331930

ABSTRACT

OBJECTIVE: Evaluation of the bending properties in one direction of three titanium polyaxial locking plate systems. MATERIALS AND METHODS: The Polyaxial Advanced Locking System (PAX®) straight plate (PAX SP), the PAX® reconstruction plate (PAX RP), and the VetLOX reconstruction plates (VetLOX) were evaluated individually and as constructs applied to a bone model simulating a fracture gap and compared using a two-way analysis of variance and Tukey post-hoc analysis. RESULTS: The PAX SP had the highest values of bending stiffness, bending structural stiffness and bending strength. When tested as plates alone, the PAX RP and VetLOX showed no differences with regard to bending stiffness and bending structural stiffness, whilst the PAX RP had significantly higher strength. The PAX RP construct had significantly higher bending stiffness, bending structural stiffness and bending strength than the VetLOX construct. CLINICAL RELEVANCE: The PAX RP and VetLOX reconstruction plates are much more likely to fail when used as bridging implants, thus adjunct support is needed. The lower bending strength of the VetLOX reconstruction plates suggests it should not be used in fractures under high loads.


Subject(s)
Bone Plates/veterinary , Fractures, Bone/veterinary , Materials Testing/veterinary , Titanium , Animals , Biomechanical Phenomena , Bone Plates/standards , Bone Screws , Fracture Fixation, Internal , Fractures, Bone/surgery , Models, Biological
SELECTION OF CITATIONS
SEARCH DETAIL
...