Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Ground Water Monit Remediat ; 44(2): 101-117, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38846907

ABSTRACT

Understanding vapor intrusion (VI) temporal variability is key for the design of sampling strategies intended to assess reasonable maximum exposure of indoor air concentrations of volatile organic compounds (VOCs) as well as risk evaluation and mitigation planning. VI temporal variability has previously been shown to be dependent on the complex interactions of multiple independent variables-meteorological, hydrogeological, and human behavioral. Several meteorological variables, including barometric pressure, wind speed, and rainfall, are linked during tropical and extratropical storm events. High-frequency meteorological and indoor VOC data from a series of seven tropical storms and four extratropical storms were collected at a single industrial building with multiple heating, ventilation, and air conditioning (HVAC) zones. The storms and sampling zones showed a variety of effects on trichloroethylene (TCE) concentrations in indoor air. In one zone (supply room), increases in TCE concentrations often, but not always, closely coincided with decreasing barometric pressure, sustained wind speeds over 32 km/h (20 mph), and differential pressures indicating subslab to indoor flow. A second zone, in a restroom, did not show a consistent pattern of temporal correlation between meteorological factors and indoor air concentrations. While peak indoor air concentrations may be associated with the passage of cyclonic storms at some sampling locations, this does not appear to be generalizable to all sampling locations. The observed increase in indoor air concentration potentially attributable to these storms is typically less than an order of magnitude and the duration ranges from a day to a week.

2.
Ground Water Monit Remediat ; 41(2): 99-111, 2021 May 21.
Article in English | MEDLINE | ID: mdl-34335002

ABSTRACT

Temporal and spatial variability of indoor air volatile organic compound (VOC) concentrations can complicate vapor intrusion (VI) assessment and decision-making. Indicators and tracers (I&T) of VI, such as differential temperature, differential pressure, and indoor radon concentration, are low-cost lines of evidence to support sampling scheduling and interpretation of indoor air VOC sampling results. This study compares peak indoor air chlorinated VOC concentrations and I&T conditions before and during those peak events at five VI sites. The sites differ geographically and in their VI conceptual site models (CSM). Relative to site-specific baseline values, the results show that cold or falling outdoor temperatures, rising cross slab differential pressures, and increasing indoor radon concentrations can predict peak VOC concentrations. However, cold outdoor air temperature was not useful at one site where elevated shallow soil temperature was a better predictor. Correlations of peak VOC concentrations to elevated or rising barometric pressure and low wind speed were also observed with some exceptions. This study shows how the independent variables that control or predict peak indoor air VOC concentrations are specific to building types, climates, and VI CSMs. More I&T measurements at VI sites are needed to identify scenario-specific baseline and peak related I&T conditions to improve decision-making.

3.
Ground Water Monit Remediat ; 40(1): 74-85, 2020 Feb 11.
Article in English | MEDLINE | ID: mdl-33414610

ABSTRACT

Soil vapor extraction (SVE) is effective for removing volatile organic compound (VOC) mass from the vadose zone and reducing the potential for vapor intrusion (VI) into overlying and surrounding buildings. However, the relationship between residual mass in the subsurface and VI is complex. Through a series of alternating extraction (SVE on) and rebound (SVE off) periods, this field study explored the relationship and aspects of SVE applicable to VI mitigation in a commercial/light-industrial setting. The primary objective was to determine if SVE could provide VI mitigation over a wide area encompassing multiple buildings, city streets, and subsurface utilities and eliminate the need for individual subslab depressurization systems. We determined that SVE effectively mitigates offsite VI by intercepting or diluting contaminant vapors that would otherwise enter buildings through foundation slabs. Data indicate a measurable (5 Pa) influence of SVE on subslab/indoor pressure differential may occur but is not essential for effective VI mitigation. Indoor air quality improvements were evident in buildings 100 to 200 feet away from SVE including those without a measurable reversal of differential pressure across the slab or substantial reductions in subslab VOC concentration. These cases also demonstrated mitigation effects across a four-lane avenue with subsurface utilities. These findings suggest that SVE affects distant VI entry points with little observable impact on differential pressures and without relying on subslab VOC concentration reductions.

4.
Sci Total Environ ; 598: 772-779, 2017 Nov 15.
Article in English | MEDLINE | ID: mdl-28456127

ABSTRACT

The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampled during most vapor intrusion investigations. We have used a tracer study and VOC concentration measurements to evaluate the role of the combined sanitary/storm sewer line in VOC transport at the USEPA vapor intrusion research duplex in Indianapolis, Indiana. The results from the tracer study demonstrated gas migration from the sewer main line into the duplex. The migration pathway appears to be complex and may include leakage from the sewer lateral at a location below the building foundation. Vapor samples collected from the sewer line demonstrated the presence of tetrachloroethene (PCE) and chloroform in the sewer main in front of the duplex and at multiple sample locations within the sewer line upstream of the duplex. These test results combined with results from the prior multi-year study of the duplex indicate that the sewer line plays an important role in transport of VOCs from the subsurface source to the immediate vicinity of the duplex building envelope.

SELECTION OF CITATIONS
SEARCH DETAIL
...