Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
J Arthroplasty ; 35(2): 550-556, 2020 02.
Article in English | MEDLINE | ID: mdl-31601456

ABSTRACT

BACKGROUND: Recurrent hemarthrosis after knee arthroplasty is an uncommon and disabling complication of this frequently performed procedure. Selective endovascular embolization of the geniculate arteries is one of the therapeutic options to manage this complication. The purpose of this study is to analyze the effectiveness of this treatment in patients suffering from recurrent hemarthrosis after knee arthroplasty. METHODS: We performed a retrospective study of 31 patients (39 embolization procedures) with recurrent hemarthrosis after knee arthroplasty. There were 17 men and 14 women with a median age of 67 years (range 48-90). All patients were referred for geniculate artery embolization between January 2007 and November 2016. RESULTS: Twenty-seven procedures were executed on the right side and 12 on the left side. Total knee arthroplasty was performed on 29 patients, only 2 patients underwent unicompartmental knee arthroplasty. Embolization of the superior geniculate arteries was achieved in all patients. In 12 of 39 procedures (31%), at least 1 of the inferior geniculate arteries could not be catheterized, therefore embolization was achieved through collaterals. Symptomatic improvement was observed in 26 of 31 patients (84%). Discomfort or mild postprocedural pain was observed in most patients, needing only minor pain medication, mostly resolving within 24 hours. Two patients presented with a severe complication: a 48-year-old male patient developed septic arthritis and an 85-year-old hypertensive female patient treated with anticoagulants showed aseptic necrosis of the femoral condyles. CONCLUSION: Embolization of geniculate arteries is a safe and effective treatment in recurrent hemarthrosis post knee arthroplasty. Clinical improvement was seen in most patients.


Subject(s)
Arthroplasty, Replacement, Knee , Embolization, Therapeutic , Aged , Aged, 80 and over , Arteries , Arthroplasty, Replacement, Knee/adverse effects , Embolization, Therapeutic/adverse effects , Female , Hemarthrosis/surgery , Hemarthrosis/therapy , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Middle Aged , Recurrence , Retrospective Studies
3.
Cancer Imaging ; 19(1): 78, 2019 Nov 29.
Article in English | MEDLINE | ID: mdl-31783926

ABSTRACT

PURPOSE: A newly developed image processing technique fuses conventional windows into a single 'All-In-One' (AIO) window. This study aims to evaluate variability of CT measurement of lesions in thoracic oncology patients on this novel AIO-window. METHODS: Six radiologists with different levels of expertise measured 368 lesions of various size, origin and sharpness. All lesions were measured twice on the AIO-window and twice on the conventional window settings. Intraclass correlation coefficients and Bland-Altman plots were used to assess intra- and interobserver variability. RESULTS: Overall intra-observer agreement for lesion diameters on the AIO-window and conventional window settings was 0.986 (95% Confidence interval (CI): 0.983-0.989) and 0.991 (95% CI 0.989-0.993) respectively. For interobserver agreement this was 0.982 (95% CI 0.979-0.985) (AIO) and 0.979 (95% CI 0.957-0.982) (conventional). For both the AIO and conventional windows, intra- and interobserver agreement were dependent on size, sharpness and reader experience. Measurement variability decreased with increasing lesion size. Regarding sharpness, inter- and intra-observer agreement ranged from 0.986-0.989 (AIO) and 0.985-0.992 (conventional) for well-defined lesions and from 0.978-0.983 (AIO) and 0.974-0.991 (conventional) for ill-defined lesions. CONCLUSIONS: Lesion diameters were consistently smaller on the AIO-window compared to conventional window settings. Overall intra- and interobserver variability rates were similar for the AIO-window and conventional window settings. We conclude that the AIO-window offers a reliable and reproducible alternative for measurement of thoracic lesions.


Subject(s)
Abdomen/diagnostic imaging , Image Processing, Computer-Assisted/methods , Multidetector Computed Tomography/methods , Neoplasms/diagnostic imaging , Thorax/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Image Processing, Computer-Assisted/standards , Lung Neoplasms/diagnostic imaging , Male , Middle Aged , Multidetector Computed Tomography/standards , Observer Variation , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...