Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Skin Health Dis ; 3(4): e234, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37538326

ABSTRACT

Continuous glucose monitors (CGM) and insulin pumps have become the preferred treatment option for most young children and adolescents with type 1 diabetes (T1D), by avoiding fingerstick testing and providing real-time glucose measurements. These medical devices and their adhesives contain substances which have been identified as being responsible for allergic contact dermatitis. We describe the case of a toddler who developed severe contact dermatitis from her diabetes devices, leading to secondary infections and hospital admissions. This was followed by the development of a symmetrical exanthema with retroauricular and glutaeal distribution. Patch tests were positive for isobornyl acrylate (IBOA) and 4-tert-butylcatechol (PTBC). Her symmetrical exanthema was interpreted as systemic contact dermatitis due to IBOA and PTBC in her diabetes devices. We suspect that systemic contact dermatitis is an underreported complication in diabetic patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...