Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 200
Filter
1.
J Environ Sci (China) ; 145: 117-127, 2024 Nov.
Article in English | MEDLINE | ID: mdl-38844312

ABSTRACT

Atmospheric particulate matter (PM) exacerbates the risk factor for Alzheimer's and Parkinson's diseases (PD) by promoting the alpha-synuclein (α-syn) pathology in the brain. However, the molecular mechanisms of astrocytes involvement in α-syn pathology underlying the process remain unclear. This study investigated PM with particle size <200 nm (PM0.2) exposure-induced α-syn pathology in ICR mice and primary astrocytes, then assessed the effects of mammalian target of rapamycin inhibitor (PP242) in vitro studies. We observed the α-syn pathology in the brains of exposed mice. Meanwhile, PM0.2-exposed mice also exhibited the activation of glial cell and the inhibition of autophagy. In vitro study, PM0.2 (3, 10 and 30 µg/mL) induced inflammatory response and the disorders of α-syn degradation in primary astrocytes, and lysosomal-associated membrane protein 2 (LAMP2)-mediated autophagy underlies α-syn pathology. The abnormal function of autophagy-lysosome was specifically manifested as the expression of microtubule-associated protein light chain 3 (LC3II), cathepsin B (CTSB) and lysosomal abundance increased first and then decreased, which might both be a compensatory mechanism to toxic α-syn accumulation induced by PM0.2. Moreover, with the transcription factor EB (TFEB) subcellular localization and the increase in LC3II, LAMP2, CTSB, and cathepsin D proteins were identified, leading to the restoration of the degradation of α-syn after the intervention of PP242. Our results identified that PM0.2 exposure could promote the α-syn pathological dysregulation in astrocytes, providing mechanistic insights into how PM0.2 increases the risk of developing PD and highlighting TFEB/LAMP2 as a promising therapeutic target for antagonizing PM0.2 toxicity.


Subject(s)
Astrocytes , Autophagy , Basic Helix-Loop-Helix Leucine Zipper Transcription Factors , Lysosomal-Associated Membrane Protein 2 , Lysosomes , Mice, Inbred ICR , Particulate Matter , alpha-Synuclein , Animals , Astrocytes/drug effects , alpha-Synuclein/metabolism , Autophagy/drug effects , Mice , Lysosomes/metabolism , Lysosomes/drug effects , Basic Helix-Loop-Helix Leucine Zipper Transcription Factors/metabolism , Lysosomal-Associated Membrane Protein 2/metabolism , Particulate Matter/toxicity , Air Pollutants/toxicity
2.
Sci Rep ; 14(1): 10602, 2024 05 08.
Article in English | MEDLINE | ID: mdl-38719935

ABSTRACT

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Subject(s)
Anastomosis, Surgical , Feasibility Studies , Animals , Dogs , Anastomosis, Surgical/methods , Stomach/surgery , Magnets , Magnetics , Natural Orifice Endoscopic Surgery/methods , Natural Orifice Endoscopic Surgery/instrumentation , Colon/surgery , Male
3.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38690021

ABSTRACT

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Subject(s)
Disease Models, Animal , Magnets , Trachea , Tracheoesophageal Fistula , Animals , Dogs , Tracheoesophageal Fistula/surgery , Tracheoesophageal Fistula/pathology , Tracheoesophageal Fistula/etiology , Trachea/surgery , Trachea/pathology , Esophagus/surgery , Esophagus/pathology , Esophagus/diagnostic imaging , Gastroscopy/instrumentation , Gastroscopy/methods , Operative Time , Male , Magnetics/instrumentation , Equipment Design , Humans
4.
BMC Med Imaging ; 24(1): 112, 2024 May 16.
Article in English | MEDLINE | ID: mdl-38755567

ABSTRACT

Accurate preoperative differentiation of the chronic rhinosinusitis (CRS) endotype between eosinophilic CRS (eCRS) and non-eosinophilic CRS (non-eCRS) is an important topic in predicting postoperative outcomes and administering personalized treatment. To this end, we have constructed a sinus CT dataset, which comprises CT scan data and pathological biopsy results from 192 patients of chronic rhinosinusitis with nasal polyps (CRSwNP), treated at the Second Affiliated Hospital of Shantou University Medical College between 2020 and 2022. To differentiate CRSwNP endotype on preoperative CT and improve efficiency at the same time, we developed a multi-view fusion model that contains a mini-architecture with each network of 10 layers by modifying the deep residual neural network. The proposed model is trained on a training set and evaluated on a test set. The multi-view deep learning fusion model achieved the area under the receiver-operating characteristics curve (AUC) of 0.991, accuracy of 0.965 and F1-Score of 0.970 in test set. We compared the performance of the mini-architecture with other lightweight networks on the same Sinus CT dataset. The experimental results demonstrate that the developed ResMini architecture contribute to competitive CRSwNP endotype identification modeling in terms of accuracy and parameter number.


Subject(s)
Deep Learning , Nasal Polyps , Rhinitis , Sinusitis , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Sinusitis/diagnostic imaging , Rhinitis/diagnostic imaging , Nasal Polyps/diagnostic imaging , Nasal Polyps/surgery , Nasal Polyps/pathology , Chronic Disease , Neural Networks, Computer , Female , Male , Adult , Middle Aged , ROC Curve
5.
Bioelectrochemistry ; 158: 108726, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38733722

ABSTRACT

Mucus hypersecretion resulting from excessive proliferation and metaplasia of goblet cells in the airways is the pathological foundation for Chronic obstructive pulmonary disease (COPD). Clinical trials have confirmed the clinical efficacy of pulsed electric field ablation (PFA) for COPD, but its underlying mechanisms is poorly understood. Cellular and animal models of COPD (rich in goblet cells) were established in this study to detect goblet cells' sensitivity to PFA. Schwan's equation was adopted to calculate the cells' transmembrane potential and the electroporation areas in the cell membrane. We found that goblet cells are more sensitive to low-intensity PFA (250 V/cm-500 V/cm) than BEAS-2B cells. It is attributed to the larger size of goblet cells, which allows a stronger transmembrane potential formation under the same electric field strength. Additionally, the transmembrane potential of larger-sized cells can reach the cell membrane electroporation threshold in more areas. Trypan blue staining confirmed that the cells underwent IRE rate was higher in goblet cells than in BEAS-2B cells. Animal experiments also confirmed that the airway epithelium of COPD is more sensitive to PFA. We conclude that lower-intensity PFA can selectively kill goblet cells in the COPD airway epithelium, ultimately achieving the therapeutic effect of treating COPD.


Subject(s)
Electroporation , Goblet Cells , Pulmonary Disease, Chronic Obstructive , Goblet Cells/pathology , Pulmonary Disease, Chronic Obstructive/pathology , Pulmonary Disease, Chronic Obstructive/metabolism , Pulmonary Disease, Chronic Obstructive/therapy , Animals , Humans , Electroporation/methods , Cell Line , Membrane Potentials , Male , Ablation Techniques/methods , Electricity , Mice
6.
Int J Surg ; 2024 May 29.
Article in English | MEDLINE | ID: mdl-38814355

ABSTRACT

BACKGROUND: Some cases of laparoscopic-assisted liver transplantation (LA-LT) with utilization of reduced-size grafts has been reported. We here introduced successful utilization of LA-LT with whole liver grafts and magnetic portal vein anastomosis. METHODS: Eight patients with liver cirrhosis were included for LA-LT using donor organs after cardiac death. The surgical procedures included purely laparoscopic explant hepatectomy and whole-liver graft implantation via the midline incision. After explant removal, the whole-liver graft was then placed in situ, and a side-to-side cavo-caval anastomosis with 4-5 cm oval opening was performed. The magnetic rings were everted on the donor and recipient portal vein, respectively, and the instant attachment of the two magnets at the donor and recipient portal vein allowed fast blood reperfusion, followed by continuous suturing on the surface of the magnets. RESULTS: The median operation time was 495 (range 420-630). The median time of explant hepatectomy and IVC anastomosis was 239 (range 150-300) min and 14.5 (range 10-19) min, respectively. Of note, the median anhepatic time was 25 (range 20-35) min. All the patients were discharged home with no major complications after more than six months follow-up. CONCLUSION: LA-LT with full-size graft is feasible and utilization of magnetic anastomosis would further simplify the procedure.

7.
World J Gastrointest Surg ; 16(5): 1336-1343, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38817276

ABSTRACT

BACKGROUND: Magnetic anchor technique (MAT) has been applied in laparoscopic cholecystectomy and laparoscopic appendectomy, but has not been reported in laparoscopic partial hepatectomy. AIM: To evaluate the feasibility of the MAT in laparoscopic left lateral segment liver resection. METHODS: Retrospective analysis was conducted on the clinical data of eight patients who underwent laparoscopic left lateral segment liver resection assisted by MAT in our department from July 2020 to November 2021. The Y-Z magnetic anchor devices (Y-Z MADs) was independently designed and developed by the author of this paper, which consists of the anchor magnet and magnetic grasping apparatus. Surgical time, intraoperative blood loss, intraoperative accidents, operator experience, postoperative incision pain score, postoperative complications, and other indicators were evaluated and analyzed. RESULTS: All eight patients underwent a MAT-assisted laparoscopic left lateral segment liver resection, including three patients undertaking conventional 5-port and five patients having a transumbilical single-port operation. The mean operation time was 138 ± 34.32 min (range 95-185 min) and the mean intraoperative blood loss was 123 ± 88.60 mL (range 20-300 mL). No adverse events occurred during the operation. The Y-Z MADs showed good workability and maneuverability in both tissue and organ exposure. In particular, the operators did not experience either a "chopstick" or "sword-fight" effect in the single-port laparoscopic operation. CONCLUSION: The results show that the MAT is safe and feasible for laparoscopic left lateral segment liver resection, especially, exhibits its unique abettance for transumbilical single-port laparoscopic left lateral segment liver resection.

8.
World J Gastrointest Surg ; 16(5): 1443-1448, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38817285

ABSTRACT

BACKGROUND: The treatment of postoperative anastomotic stenosis (AS) after resection of colorectal cancer is challenging. Endoscopic balloon dilation is used to treat stenosis in such cases, but some patients do not show improvement even after multiple balloon dilations. Magnetic compression technique (MCT) has been used for gastrointestinal anastomosis, but its use for the treatment of postoperative AS after colorectal cancer surgery has rarely been reported. CASE SUMMARY: We report a 72-year-old man who underwent radical resection of colorectal cancer and ileostomy one year ago. An ileostomy closure was prepared six months ago, but colonoscopy revealed a narrowing of the rectal anastomosis. Endoscopic balloon dilation was performed three times, but colonoscopy showed no significant improvement in stenosis. The AS was successfully treated using MCT. CONCLUSION: MCT is a minimally invasive method that can be used for the treatment of postoperative AS after colorectal cancer surgery.

9.
Sci Rep ; 14(1): 12462, 2024 05 30.
Article in English | MEDLINE | ID: mdl-38816430

ABSTRACT

Various surgical methods have so far been developed for treating rectovaginal fistula (RVF), each with its own advantages and disadvantages. The lack of standardized animal models of RVF is a major reason for the failure to establish a unified and effective surgical method for the treatment of RVF. This study aimed to explore the feasibility of an RVF animal model by magnetic compression and compare it with the traditional modeling method. Thirty-two female Japanese white rabbits were randomly divided into four groups: A, B, C, and D, based on how the rectovaginal septum was treated. The operation time, intraoperative blood loss, and model success rate of each group were determined. The experimental animals were euthanized 2 weeks after the operation. Their rectovaginal septum specimens were obtained. RVF was observed by the naked eye. The fistula size was measured. Histological changes of fistula were observed by hematoxylin and eosin and Masson staining. All rabbits completed the RVF model and survived 2 weeks after the operation. Groups A and B had no bleeding, while groups C and D had < 0.5 mL of bleeding. The magnet detached in 4-6 days in group A, while it remained in place for 2 weeks after surgery in group B. Only one group D rabbit had a plastic hose for 2 weeks after surgery. The RVFs of groups A and C healed by themselves. In group B, the fistula was well formed. In group D, fistula healing was observed in three animals and the diameter of the fistulas was only 2.82-4.64 mm in the other four animals. Groups B and D had a scar on the inner surface of fistulas. Our study shows that the magnetic compression technique based on the T-shaped magnet is a highly useful method to establishing a continuous and stable RVF model in rabbits.


Subject(s)
Disease Models, Animal , Rectovaginal Fistula , Animals , Rabbits , Female , Rectovaginal Fistula/surgery , Rectovaginal Fistula/pathology
10.
Life Sci ; 349: 122718, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38754815

ABSTRACT

Chronic obstructive pulmonary disease (COPD) is projected to become the third leading cause of death globally by 2030. Despite the limited treatment options available for advanced COPD, which are mostly restricted to costly lung transplants, physical ablation therapy offers promising alternatives. This technique focuses on ablating lesioned airway epithelium, reducing secretions and obstructions, and promoting normal epithelial regeneration, demonstrating significant therapeutic potential. Physical ablation therapy primarily involves thermal steam ablation, cryoablation, targeted lung denervation, and high-voltage pulsed electric field ablation. These methods help transform the hypersecretory phenotype, alleviate airway inflammation, and decrease the volume of emphysematous lung segments by targeting goblet cells and damaged lung areas. Compared to traditional treatments, endoscopic physical ablation offers fewer injuries, quicker recovery, and enhanced safety. However, its application in COPD remains limited due to inconsistent clinical outcomes, a lack of well-understood mechanisms, and the absence of standardized guidelines. This review begins by exploring the development of these ablation techniques and their current clinical uses in COPD treatment. It then delves into the therapeutic effects reported in recent clinical studies and discusses the underlying mechanisms. Finally, the review assesses the future prospects and challenges of employing ablation technology in COPD clinical practice, aiming to provide a practical reference and a theoretical basis for its use and inspire further research.


Subject(s)
Ablation Techniques , Pulmonary Disease, Chronic Obstructive , Pulmonary Disease, Chronic Obstructive/therapy , Pulmonary Disease, Chronic Obstructive/surgery , Humans , Ablation Techniques/methods , Lung , Animals
11.
Biomaterials ; 309: 122599, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38703409

ABSTRACT

Development of bioadhesives that can be facilely delivered by endoscope and exhibit instant and robust adhesion with gastric tissues to promote gastric ulcer healing remains challenging. In this study, an advanced bioadhesive is prepared through free radical polymerization of ionized N-acryloyl phenylalanine (iAPA) and N-[tris (hydroxymethyl) methyl] acrylamide (THMA). The precursory polymer solution exhibits low viscosity with the capability for endoscope delivery, and the hydrophilic-hydrophobic transition of iAPA upon exposure to gastric acid can trigger gelation through phenyl groups assisted multiple hydrogen bonds formation and repel water molecules on tissue surface to establish favorable environment for interfacial interactions between THMA and functional groups on tissues. The in-situ formed hydrogel features excellent stability in acid environment (14 days) and exhibits firm wet adhesion to gastric tissue (33.4 kPa), which can efficiently protect the wound from the stimulation of gastric acid and pepsin. In vivo studies reveal that the bioadhesive can accelerate the healing of ulcers by inhibiting inflammation and promoting capillary formation in the acetic acid-induced gastric ulcer model in rats. Our work may provide an effective solution for the treatment of gastric ulcers clinically.


Subject(s)
Stomach Ulcer , Wound Healing , Animals , Stomach Ulcer/drug therapy , Stomach Ulcer/chemically induced , Wound Healing/drug effects , Hydrogen-Ion Concentration , Rats , Rats, Sprague-Dawley , Male , Hydrogels/chemistry , Tissue Adhesives/chemistry , Tissue Adhesives/pharmacology , Phenylalanine/chemistry
12.
Asian J Androl ; 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38563741

ABSTRACT

ABSTRACT: The second-to-fourth digit (2D:4D) ratio is thought to be associated with prenatal androgen exposure. However, the relationship between the 2D:4D ratio and hypospadias is poorly understood, and its molecular mechanism is not clear. In this study, by analyzing the hand digit length of 142 boys with hypospadias (23 distal, 68 middle, and 51 proximal) and 196 controls enrolled in Shanghai Children's Hospital (Shanghai, China) from December 2020 to December 2021, we found that the 2D:4D ratio was significantly increased in boys with hypospadias (P < 0.001) and it was positively correlated with the severity of the hypospadias. This was further verified by the comparison of control mice and prenatal low testosterone mice model obtained by knocking out the risk gene (dynein axonemal heavy chain 8 [DNAH8]) associated with hypospadias. Furthermore, the discrepancy was mainly caused by a shift in 4D. Proteomic characterization of a mouse model validated that low testosterone levels during pregnancy can impair the growth and development of 4D. Comprehensive mechanistic explorations revealed that during the androgen-sensitive window, the downregulation of the androgen receptor (AR) caused by low testosterone levels, as well as the suppressed expression of chondrocyte proliferation-related genes such as Wnt family member 5a (Wnt5a), Wnt5b, Smad family member 2 (Smad2), and Smad3; mitochondrial function-related genes in cartilage such as AMP-activated protein kinase (AMPK) and nuclear respiratory factor 1 (Nrf-1); and vascular development-related genes such as myosin light chain (MLC), notch receptor 3 (Notch3), and sphingosine kinase 1 (Sphk1), are responsible for the limitation of 4D growth, which results in a higher 2D:4D ratio in boys with hypospadias via decreased endochondral ossification. This study indicates that the ratio of 2D:4D is a risk marker of hypospadias and provides a potential molecular mechanism.

13.
World J Gastrointest Surg ; 16(3): 860-870, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38577092

ABSTRACT

BACKGROUND: Despite much work having been conducted on magnetic compression anastomosis (MCA) in the digestive tract, there are no reports on the influence of magnetic force on the anastomosis. AIM: To investigate the effect of different magnetic force magnets on the MCA of the digestive tract. METHODS: Two groups of magnets of the same sizes but different magnetic forces were designed and produced. A total of 24 Sprague-Dawley rats were randomly assigned into two groups (powerful magnet group and common magnet group), with 12 rats in each group. Two types of magnets were used to complete the colonic side-to-side anastomosis of the rats. The operation time and magnet discharge time were recorded. The anastomotic specimens were obtained 4 wk after the operation and then the burst pressure and diameter of the anastomosis were measured, and the anastomosis was observed via the naked eye and subjected to histological examination. RESULTS: The magnetic forces of the powerful and common magnet groups at zero distance were 8.26 N and 4.10 N, respectively. The colonic side-to-side anastomosis was completed in all 24 rats, and the operation success rate and postoperative survival rate were 100%. No significant difference was noted in the operation time between the two groups. The magnet discharge time of the powerful magnet group was slightly longer than that of the common magnet group, but the difference was not statistically significant (P = 0.513). Furthermore, there was no statistical difference in the burst pressure (P = 0.266) or diameter of magnetic anastomosis (P = 0.095) between the two groups. The gross specimens of the two groups showed good anastomotic healing, and histological observation indicated good mucosal continuity without differences on healing. CONCLUSION: In the rat colonic side-to-side MCA model, both the powerful magnet with 8.26 N and the common magnet with 4.10 N showed no significant impact on the anastomosis establishment process or its effect.

14.
Sci Rep ; 14(1): 7907, 2024 04 04.
Article in English | MEDLINE | ID: mdl-38575669

ABSTRACT

Vesicovaginal fistula lacks a standard, established animal model, making surgical innovations for this condition challenging. Herein, we aimed to non-surgically establish vesicovaginal fistula using the magnetic compression technique, and the feasibility of this method was explored using eight female Beagle dogs as model animals. In these dogs, cylindrical daughter and parent magnets were implanted into the bladder and vagina, respectively, after anesthesia, and the positions of these magnets were adjusted under X-ray supervision to make them attract each other, thus forming the structure of daughter magnet-bladder wall-vaginal wall-parent magnet. Operation time and collateral damage were recorded. The experimental animals were euthanized 2 weeks postoperatively, and the vesicovaginal fistula gross specimens were obtained. The size of the fistula was measured. Vesicovaginal fistula was observed by naked eye and under a light microscope. Magnet placement was successful in all dogs, and remained in the established position for the reminder of the experiment. The average operation time was 14.38 min ± 1.66 min (range, 12-17 min). The dogs were generally in good condition postoperatively and were voiding normally, with no complications like bleeding and urine retention. The magnets were removed from the vagina after euthanasia. The vesicovaginal fistula was successfully established according to gross observation, and the fistula diameters were 4.50-6.24 mm. Histological observation revealed that the bladder mucosa and vaginal mucosa were in close contact on the internal surface of the fistula. Taken together, magnetic compression technique is a simple and feasible method to establish an animal model of vesicovaginal fistula using Beagle dogs. This model can help clinicians study new surgical techniques and practice innovative approaches for treating vesicovaginal fistula.


Subject(s)
Vesicovaginal Fistula , Humans , Dogs , Animals , Female , Vesicovaginal Fistula/surgery , Vesicovaginal Fistula/etiology , Urinary Bladder/surgery , Vagina/surgery , Magnetics , Magnetic Phenomena
15.
World J Gastroenterol ; 30(6): 599-606, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38463020

ABSTRACT

BACKGROUND: Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging, especially for patients who do not respond well to endoscopy. In cases where patients have undergone an enterostomy, the stenosis can be easily resolved through magnetic compression. However, common magnetic compression techniques cannot be performed on those without enterostomy. We designed a novel Y-Z deformable magnetic ring (Y-Z DMR) and successfully applied it to a patient with a stenosis rectal anastomosis and without enterostomy after rectal cancer surgery. CASE SUMMARY: We here report the case of a 57-year-old woman who had undergone a laparoscopic radical rectum resection (Dixon) for rectal cancer. However, she started facing difficulty in defecation 6 months after surgery. Her colonoscopy indicated stenosis of the rectal anastomosis. Endoscopic balloon dilation was performed six times on her. However, the stenosis still showed a trend of gradual aggravation. Because the patient did not undergo an enterostomy, the conventional endoscopic magnetic compression technique could not be performed. Hence, we implemented a Y-Z DMR implemented through the anus under single channel. The magnetic ring fell off nine days after the operation and the rectal stenosis was relieved. The patient was followed up for six months and reported good defecation. CONCLUSION: The Y-Z DMR deformable magnetic ring is an excellent treatment strategy for patients with rectal stenosis and without enterostomy.


Subject(s)
Laparoscopy , Rectal Neoplasms , Humans , Female , Middle Aged , Constriction, Pathologic/surgery , Constriction, Pathologic/etiology , Rectal Neoplasms/complications , Rectal Neoplasms/surgery , Rectum/diagnostic imaging , Rectum/surgery , Laparoscopy/adverse effects , Anastomosis, Surgical/adverse effects , Postoperative Complications/etiology , Magnetic Phenomena , Retrospective Studies
16.
J Hepatol ; 80(6): 928-940, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38336346

ABSTRACT

BACKGROUND & AIMS: Men are more prone to develop and die from liver fibrosis than women. In this study, we aim to investigate how sex-determining region Y gene (SRY) in hepatocytes promotes liver fibrosis. METHODS: Hepatocyte-specific Sry knock-in (KI), Sry knockout (KO), and Sry KI with platelet-derived growth factor receptor α (Pdgfrα) KO mice were generated. Liver fibrosis was induced in mice by bile duct ligation for 2 weeks or carbon tetrachloride treatment for 6 weeks. In addition, primary hepatocytes, hepatic stellate cells (HSCs), and immortalized cell lines were used for in vitro studies and mechanistic investigation. RESULTS: Compared to females, the severity of toxin- or cholestasis-induced liver fibrosis is similarly increased in castrated and uncastrated male mice. Among all Y chromosome-encoded genes, SRY was the most significantly upregulated and consistently increased gene in fibrotic/cirrhotic livers in male patients and in mouse models. Sry KI mice developed exacerbated liver fibrosis, whereas Sry KO mice had alleviated liver fibrosis, compared to age- and sex-matched control mice after bile duct ligation or administration of carbon tetrachloride. Mechanistically, both our in vivo and in vitro studies illustrated that SRY in hepatocytes can transcriptionally regulate Pdgfrα expression, and promote HMGB1 (high mobility group box 1) release and subsequent HSC activation. Pdgfrα KO or treatment with the SRY inhibitor DAX1 in Sry KI mice abolished SRY-induced HMGB1 secretion and liver fibrosis. CONCLUSIONS: SRY is a strong pro-fibrotic factor and accounts for the sex disparity observed in liver fibrosis, suggesting its critical role as a potentially sex-specific therapeutic target for prevention and treatment of the disease. IMPACT AND IMPLICATION: We identified that a male-specific gene, sex-determining region Y gene (SRY), is a strong pro-fibrotic gene that accounts for the sex disparity observed in liver fibrosis. As such, SRY might be an appropriate target for surveillance and treatment of liver fibrosis in a sex-specific manner. Additionally, SRY might be a key player in the sexual dimorphism observed in hepatic pathophysiology more generally.


Subject(s)
Hepatic Stellate Cells , Hepatocytes , Liver Cirrhosis , Mice, Knockout , Sex-Determining Region Y Protein , Animals , Male , Female , Mice , Liver Cirrhosis/genetics , Liver Cirrhosis/metabolism , Liver Cirrhosis/physiopathology , Humans , Hepatocytes/metabolism , Sex-Determining Region Y Protein/genetics , Sex-Determining Region Y Protein/metabolism , Hepatic Stellate Cells/metabolism , Sex Characteristics , Receptor, Platelet-Derived Growth Factor alpha/genetics , Receptor, Platelet-Derived Growth Factor alpha/metabolism , Carbon Tetrachloride/toxicity , Carbon Tetrachloride/adverse effects , Cholestasis/genetics , Cholestasis/metabolism , Cholestasis/physiopathology , Disease Models, Animal
17.
Nano Lett ; 24(9): 2894-2903, 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38407042

ABSTRACT

Harnessing the potential of tumor-associated macrophages (TAMs) to engulf tumor cells offers promising avenues for cancer therapy. Targeting phagocytosis checkpoints, particularly the CD47-signal regulatory protein α (SIRPα) axis, is crucial for modulating TAM activity. However, single checkpoint inhibition has shown a limited efficacy. In this study, we demonstrate that ferrimagnetic vortex-domain iron oxide (FVIO) nanoring-mediated magnetic hyperthermia effectively suppresses the expression of CD47 protein on Hepa1-6 tumor cells and SIRPα receptor on macrophages, which disrupts CD47-SIRPα interaction. FVIO-mediated magnetic hyperthermia also induces immunogenic cell death and polarizes TAMs toward M1 phenotype. These changes collectively bolster the phagocytic ability of macrophages to eliminate tumor cells. Furthermore, FVIO-mediated magnetic hyperthermia concurrently escalates cytotoxic T lymphocyte levels and diminishes regulatory T cell levels. Our findings reveal that magnetic hyperthermia offers a novel approach for dual down-regulation of CD47 and SIRPα, reshaping the tumor microenvironment to stimulate immune responses, culminating in significant antitumor activity.


Subject(s)
Hyperthermia, Induced , Neoplasms , Humans , CD47 Antigen , Down-Regulation , Immunotherapy , Phagocytosis , Magnetic Phenomena , Neoplasms/pathology , Tumor Microenvironment
18.
BMC Gastroenterol ; 24(1): 20, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38182996

ABSTRACT

BACKGROUND: To investigate the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR), designed and developed by us, for endoscopic gastrointestinal bypass anastomosis. METHODS: Ten experimental pigs were used as model animals. The DSAMAR comprises 10 trapezoidal magnetic units, arranged in a straight line under the constraint of a guide wire. When the desired anastomosis site is reached under the guidance of an endoscope, the catheter pushes the magnetic unit along the guide wire. The linear DSAMAR can be assembled into a circular DSAMAR. Two DSAMARs were inserted, one at the end of the duodenum and the other into the stomach successively. They attracted each other and compressed the wall of the stomach and duodenum to establish gastrointestinal bypass anastomosis. The experimental pigs were euthanized 4 weeks after the operation, and the gastrointestinal bypass anastomosis specimens were obtained. The anastomosis formation was evaluated by the naked eye and histology. RESULTS: Gastrointestinal bypass anastomosis with DSAMARs was successfully performed. The average operation time under an endoscope was 70.30 ± 19.05 min (range: 43-95 min). The DSAMARs were discharged through the anus 10-17 days after surgery. There were no complications such as gastrointestinal bleeding, perforation, anastomotic fistula, and gastrointestinal obstruction during and after the operation. Gastroscopy and gross specimen of the anastomosis showed a well-formed magnetic anastomosis. Histological observation showed good continuity of the serous membrane and the mucosa of magnetic anastomosis. CONCLUSION: The DSAMAR is a safe and feasible device for fashioning gastrointestinal bypass anastomosis in this animal model.


Subject(s)
Gastroscopy , Stomach , Swine , Animals , Anastomosis, Surgical , Stomach/surgery , Duodenum , Magnetic Phenomena
19.
Sci Rep ; 14(1): 1865, 2024 01 22.
Article in English | MEDLINE | ID: mdl-38253773

ABSTRACT

Magnetic compression anastomosis has been reported to have remarkable clinical outcomes. Here, we tested the applicability of a Y-Z deformable magnetic ring (DMR) for non-surgical manipulation of rectal stenosis (RS) in a beagle dog model under a transanal single-access condition. RS was modeled in 8 beagle dogs using partial ligation with silk thread. Under X-ray guidance, the Y-Z DMR was positioned at the proximal and distal ends of the RS, and the magnetic ring was bent into an "O" shape, such that the two rings were magnetically attracted. Operation time, complications during or after operation, and discharge time of the magnetic rings were recorded. The anastomosis bursting pressure was measured two weeks after removing the rings, and its formation was assessed through gross and histological examination. Partial ligation with a silk thread successfully established the canine RS model. After Y-Z DMR installation, the magnetic ring was successfully reconfigured from an "S" to an "O" shape. Strong attraction existed between the rings. The operation time was 9-15 min (average: 11.75 ± 1.98 min). No rectal bleeding or perforation occurred during or after operation. The ring was naturally expelled 7-10 days after surgery. A pressure of > 300 mmHg was recorded at the point of anastomosis rupture. The rectal anastomosis appeared to have healed properly on the surface, which was confirmed histologically, signifying the success of this procedure. A Y-Z DMR facilitated the successful recanalization of transanal single-channel RS without needing surgery in an animal model.


Subject(s)
Magnetic Phenomena , Silk , Animals , Dogs , Constriction, Pathologic/surgery , Physical Phenomena , Anastomosis, Surgical
20.
Clin Cardiol ; 47(1): e24162, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37936512

ABSTRACT

BACKGROUND: Appropriate time for ejection fraction (EF) reassessment after revascularization in patients with left ventricular dysfunction has not been investigated comprehensively, although 3 months after revascularization is recommended to stratify the risk of sudden cardiac death (SCD). HYPOTHESIS: EF reassessed within different timeframe after revascularization may have incosistent contribution for risk stratification of SCD. METHODS: Patients who had EF ≤ 40% before revascularization and had EF reassessment at least once during follow-up were included. The role of early (<3 months) versus late (3-12 months) EF measurements in prediction of all-cause mortality and SCD were compared. RESULTS: A total of 1589 patients were identified. EF reassessed <3 months was lower than EF reassessed within 3-12 months (42.1 ± 9.7% vs. 45.8 ± 10.8%; p < .01). Among 1069 patients who had EF reassessed <3 months, EF ≤ 35% was associated with a higher risk of all-cause mortality (hazard ratio [HR], 1.67; 95% confidence interval [CI], 1.22-2.29; p < .01), but had no association with the risk of SCD (HR, 1.44; 95% CI, 0.84-2.48; p = .18). By contrast, among 595 patients who had EF reassessed within 3-12 months, EF ≤ 35% was associated with higher risks of both all-cause death (HR, 1.81; 95% CI, 1.06-3.10; p = .03) and SCD (HR, 2.71; 95% CI, 1.31-5.61; p < .01). The relative contribution of SCD to all-cause death was higher in patients with EF ≤ 35% than patients with EF > 35% when EF was reassessed within 3-12 months (p = .04). However, when EF was reassessed <3 months, the mode of death was similar in patients with EF ≤ 35% versus >35% (p = .85). CONCLUSIONS: 3 to 12 months after revascularization may be appropriate for cardiac function reassessment and SCD risk stratification.


Subject(s)
Defibrillators, Implantable , Ventricular Dysfunction, Left , Humans , Stroke Volume , Risk Factors , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Risk Assessment , Defibrillators, Implantable/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...