Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Radiat Prot Dosimetry ; 147(1-2): 30-3, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21979432

ABSTRACT

Clinical audit is a systematic review of the procedures in order to improve the quality and the outcome of patient care, whereby the procedures are examined against agreed standards for good medical RADIOLOGICAL procedures. The criteria of good procedures (i.e. the good practice) are thus the cornerstones for development of clinical audits: these should be the basis of assessments regardless of the type of the audit--external, internal, comprehensive or partial. A lot of criteria for good practices are available through the recommendations and publications by international and national professional societies and other relevant organisations. For practical use in clinical audits, the criteria need to be compiled, sorted out and agreed on for the particular aims of an audit (comprehensive or partial, external or internal). The national professional and scientific societies can provide valuable contribution to this development. For examination--or treatment-specific criteria--preliminary consensus needs to be obtained with the help of clinical experts, while clinical audits can be useful as a benchmarking tool to improve the criteria.


Subject(s)
Clinical Audit , Radiology/standards , Humans , Practice Guidelines as Topic
2.
Phys Med Biol ; 48(7): 925-42, 2003 Apr 07.
Article in English | MEDLINE | ID: mdl-12701896

ABSTRACT

The inverse radiation treatment planning model for a dynamic multileaf collimator (MLC) is used to find the optimal solution of planning problem. The model for dynamic MLC is explained in Tervo et al (2003 Appl. Math. Comput. 135 227-50). The advantage of this model is that it optimizes leaf velocity parameters directly. Our algorithm uses a gradient-based local optimization method. Two patient cases, prostate carcinoma and tonsilla carcinoma, are studied. Field arrangements are pre-selected and velocity parameters for MLC leaves are optimized to obtain the prescribed dose in the patient space. In both simulated cases, high dose distribution conforms the planning target volume well and organs-at-risk are saved in most parts. Simulations show that the model has its functionality in patient treatments, although it is still formal and needs further development.


Subject(s)
Algorithms , Models, Biological , Prostatic Neoplasms/radiotherapy , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Tonsillar Neoplasms/radiotherapy , Computer Simulation , Humans , Male , Quality Control , Radiotherapy Dosage , Radiotherapy, Conformal/instrumentation
3.
J Biomech ; 34(2): 251-6, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11165290

ABSTRACT

We evaluated whether the use of cartilage thickness measurement would improve the ability of the arthroscopic indentation technique to estimate the intrinsic stiffness of articular cartilage. First, cartilage thickness and ultrasound reflection from the surface of bovine humeral head were registered in situ using a high-frequency ultrasound probe. Subsequently, cartilage was indented in situ at the sites of the ultrasound measurements using arthroscopic instruments with plane-ended and spherical-ended indenters. Finally, full-thickness cartilage disks (n=30) were extracted from the indented sites (thickness=799-1654microm) and the equilibrium Young's modulus was determined with a material testing device in unconfined compression geometry. We applied analytical and numerical indentation models for the theoretical correction of experimental indentation measurements. An aspect-ratio (the ratio of indenter radius to cartilage thickness) correction improved the correlation of the indenter force with the equilibrium Young's modulus from r(2)=0.488 to r(2)=0.642-0.648 (n=30) for the plane-ended indenter (diameter=1.000mm, height=0.300mm) and from r(2)=0.654 to r(2)=0.684-0.692 (n=30) for the spherical-ended indenter (diameter=0.500mm, height=0.100mm), depending on the indentation model used for the correction. The linear correlation between the ultrasound reflection and the Young's modulus was r(2)=0.400 (n=30). These results suggest that with large indenters, knowledge of the cartilage thickness improves the reliability of the indentation measurements, especially in pathological situations where cartilage thickness may be significantly lower than normal. Ultrasound measurements also provide diagnostically important information about cartilage thickness as well as knowledge of the integrity of the superficial zone of cartilage.


Subject(s)
Arthroscopy , Cartilage, Articular/pathology , Animals , Arthroscopy/standards , Cattle , Diagnostic Equipment , Humerus/diagnostic imaging , Methods , Pliability , Ultrasonography
4.
Phys Med Biol ; 44(10): 2511-24, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10533925

ABSTRACT

Structural alterations associated with early, mostly reversible, degeneration of articular cartilage induce tissue softening, generally preceding fibrillation and, thus, visible changes of the cartilage surface. We have already developed an indentation instrument for measuring arthroscopic stiffness of cartilage with typical thickness >2 mm. The aim of this study was to extend the applicability of the instrument for the measurement of thin (<2 mm) cartilage stiffness. Variations in cartilage thickness, which will not be known during arthroscopy, can nonetheless affect the indentation measurement, and therefore optimization of the indenter dimensions is necessary. First, we used theoretical and finite element models to compare plane-ended and spherical-ended indenters and, then, altered the dimensions to determine the optimal indenter for thin cartilage measurements. Finally, we experimentally validated the optimized indenter using bovine humeral head cartilage. Reference unconfined compression measurements were carried out with a material testing device. The spherical-ended indenter was more insensitive to the alterations in cartilage thickness (20% versus 39% in the thickness range 1.5-5 mm) than the plane-ended indenter. For thin cartilage, the optimal dimensions for the spherical-ended indenter were 0.5 mm for diameter and 0.1 mm for height. The experimental stiffness measurements with this indenter correlated well with the reference measurements (r = 0.811, n = 31, p < 0.0001) in the cartilage thickness range 0.7-1.8 mm. We conclude that the optimized indenter is reliable and well suited for the measurement of thin cartilage stiffness.


Subject(s)
Arthroscopes , Arthroscopy/methods , Cartilage, Articular/physiology , Animals , Cartilage, Articular/anatomy & histology , Cattle , Elasticity , Equipment Design , Humerus , Materials Testing , Microcomputers , Regression Analysis , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL