Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Acta Pharmaceutica Sinica B ; (6): 376-383, 2014.
Article in English | WPRIM (Western Pacific) | ID: wpr-329712

ABSTRACT

A Fourier transform infrared derivative spectroscopy (FTIR-DS) method has been developed for determining furosemide (FUR) in pharmaceutical solid dosage form. The method involves the extraction of FUR from tablets with N,N-dimethylformamide by sonication and direct measurement in liquid phase mode using a reduced path length cell. In general, the spectra were measured in transmission mode and the equipment was configured to collect a spectrum at 4 cm(-1) resolution and a 13 s collection time (10 scans co-added). The spectra were collected between 1400 cm(-1) and 450 cm(-1). Derivative spectroscopy was used for data processing and quantitative measurement using the peak area of the second order spectrum of the major spectral band found at 1165 cm(-1) (SO2 stretching of FUR) with baseline correction. The method fulfilled most validation requirements in the 2 mg/mL and 20 mg/mL range, with a 0.9998 coefficient of determination obtained by simple calibration model, and a general coefficient of variation <2%. The mean recovery for the proposed assay method resulted within the (100±3)% over the 80%-120% range of the target concentration. The results agree with a pharmacopoeial method and, therefore, could be considered interchangeable.

2.
Talanta ; 64(5): 1299-303, 2004 Dec 15.
Article in English | MEDLINE | ID: mdl-18969745

ABSTRACT

A flow injection analysis (FIA) method was developed for the determination of pyruvate in onion cultivars (Allium cepa L.) from the West-Center region of Venezuela. The reference Schwimmer and Weston (1961) (J. Agric. Food Chem. 9 (1961) 301) Batch method was modified and adapted to FIA conditions. The formation kinetic of the 2,4-dinitrophenylhydrazine (DNPH)-pyruvate complex was evaluated at room temperature and at 37 degrees C. It was demonstrated the suitability of the chromopher formation at room temperature. The optimal values for the FIA parameters were: sample injection volume 3mL, flow rate 6mLmin(-1), reactor length 1.5m, sodium hydroxide concentration 1.0molL(-1) and hydrochloric acid concentration 0.5molL(-1). The working calibration range was extended from 80mgL(-1) (Batch method) to 700mgL(-1) with the FIA set up. The sample dilution step is thus avoided, simplifying the whole analysis process. The pungency in representative samples of the cultivars Yellow granex 438, Ultra Hybrid and Red onion "Sangre de Toro" was evaluated by the flow injection analysis (FIA)-pyruvate method and the results were compared to the reference Batch pyruvate method and to the taste panel test. Non-significant differences were found at the 95% of confidence level between the FIA method and the Batch reference method. Correlation coefficient when comparing the FIA results to the taste panel test was r(2) = 0.8353. Significant differences (P < 0.05) were found in the pungency of the cultivars, the Ultra Hybrid having the highest pungency. The pungency order from minor to major was: Red onion, Texas Grano 438 and Ultra Hybrid.

SELECTION OF CITATIONS
SEARCH DETAIL
...