Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Schmerz ; 31(5): 463-482, 2017 Oct.
Article in German | MEDLINE | ID: mdl-28409236

ABSTRACT

Despite many positive developments, postoperative pain and its treatment is still not always given the necessary attention. Severe pain after surgical procedures affects a significant proportion of patients. This very fact is not only detrimental to the immediate recovery process, but can also form the basis for the development of chronic pain conditions.An adequate and effective management of perioperative pain requires appropriate organizational structures. This multidisciplinary paper which was initiated by the Austrian Society for Anaesthesiology and Intensive Care and the Austrian Pain Society and developed together with numerous specialist and professional societies dealing with the subject aims at supporting the organization of perioperative pain management structures and to make best use of proven concepts. Additional recommendations describe specific interventions for selected types of intervention.


Subject(s)
Guideline Adherence , Interdisciplinary Communication , Intersectoral Collaboration , Pain Management/methods , Pain, Postoperative/therapy , Perioperative Period , Algorithms , Analgesia, Patient-Controlled/methods , Austria , Chronic Pain/classification , Chronic Pain/diagnosis , Chronic Pain/therapy , Combined Modality Therapy/methods , Documentation/methods , Humans , Pain Measurement/methods , Pain, Postoperative/classification , Pain, Postoperative/diagnosis , Precision Medicine/methods , Risk Factors
2.
Eur J Cardiothorac Surg ; 26(4): 747-53, 2004 Oct.
Article in English | MEDLINE | ID: mdl-15450567

ABSTRACT

OBJECTIVE: Orientation-related bileaflet mechanical valve flow and velocity studies in the downstream area are limited in mitral valve replacement studies. METHODS: In five sheep, ventricular blood flow was visualized prior to the implantation of a mitral Edwards Mira Bileaflet Mechanical Valve Model 9600. The implant orientation was either anatomic, with a 45 degrees rotation, or anti-anatomic, with a 90 degrees rotation. Sheep were positioned within an 1.5T field strength MR scanner (Magnetom Sonata; Siemens) to assess time-dependent three-dimensional blood flow velocities displayed as color-encoded vectors. RESULTS: The preoperative ventricular velocity profiles presented negligible individual variances. Streamlines passed homogeneously without any spatial differences into the left ventricle. Starting from the anatomical position, the areas with inhomogeneous and accelerated local blood velocities increased in comparison to the preoperative status. Rotating the prosthesis until it was in a 45 degrees position caused a significant increase in turbulence immediately downstream; fluids stagnated longer at the apex. In the anti-anatomic orientation, mean velocities decreased. In all three positions, but less so in the anatomical position, the flow pattern of the blood helix at the apex was disturbed. The intraventricular flow patterns between prostheses in the three orientations were, however, not significant when compared to the differences between physiologic intraventricular flow and any of the postoperative measurements. CONCLUSIONS: To achieve optimal hemodynamics, rotation of the mitral valve has to be considered carefully, as has long been known from aortic valve replacement studies. To this end, a method for qualitative assessment of left ventricular blood flow patterns was developed.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Mitral Valve/physiology , Ventricular Function, Left/physiology , Animals , Blood Flow Velocity , Hemorheology , Magnetic Resonance Imaging/methods , Rotation , Sheep
3.
Public Health ; 115(5): 345-9, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11593444

ABSTRACT

Between 1983 and 1985, 595 employees who were entering retirement in East Germany were given a medical examination and asked to assess their workplace conditions. Ten years later, we examined whether occupational predictors were associated with death and functional dependence among the study participants and assessed how the surviving pensioners coped with activities and instrumental activities of daily living. We assigned the occupational factors reported between 1983 and 1985 to two scales: demands and resources. Multiple logistic regression analyses were carried out to examine the association of occupational and medical predictors with the outcome variables death and functional dependence. Workplace resources but not demands were significantly associated with a reduced chance of death in women, independent of medical diagnoses. For men neither of these associations were verified. Concerning functional dependence individual items such as 'control over work content' (for both sexes) significantly reduced the risk of developing ADL-dependence. The associations remained stable after medical diagnoses were additionally taken into consideration. The results of our study highlight the influence of occupational factors beyond working life and support the importance of starting geriatric health promotion before retirement age.


Subject(s)
Activities of Daily Living , Occupational Health , Retirement , Age Factors , Aged , Female , Germany , Humans , Job Satisfaction , Logistic Models , Male , Prospective Studies , Sex Factors , Surveys and Questionnaires
4.
Anesth Analg ; 93(5): 1093-9, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11682374

ABSTRACT

UNLABELLED: Cardiac surgery correlates with increased perioperative stress and anxiety. We tested whether preoperative extensive oral information in combination with more personal attention by the surgeon is associated with any effect on patients' perioperative stress, anxiety, and well-being. Sixty patients awaiting open heart surgery were divided into two groups. Group I consisted of 30 patients who received routine medical information through an informative pamphlet. In Group II (n = 30 patients), additional, extensive oral medical information and more personal attention by the surgeon was provided before surgery. Salivary cortisol, plasma cortisol, state anxiety, and patients' well-being were measured perioperatively. Extensive preoperative oral information in combination with more personal attention by the physician did not have any significant influence on the perioperative psychoendocrinologic course of stress. During transport to the operating room, salivary cortisol increased significantly (P < 0.001) in both groups (ranges are 95% confidence intervals) (Group I, 23.2 nmol/L [17.1-31.5]; Group II, 14.6 nmol/L [9.9-21.3]) versus the first day in the hospital (Group I, 8.4 nmol/L [6.2-11.4]; Group II, 6.7 nmol/L [5.3-8.6]). After the induction of anesthesia, plasma cortisol decreased significantly (P < 0.001) in both groups (Group I, 170.1 nmol/L [143.6-201.4]; Group II, 172.0 nmol/L [142.2-208.1]) versus preoperative levels. After surgery, well-being decreased (P = 0.003) in all patients, and patients' state anxiety was reduced (P = 0.001) after surgery. Our data demonstrate a lack of effect of extensive oral medical information that was presented as part of clinical routine on the perioperative psychoendocrinologic course of stress. High levels of stress during transport to the operating room were detected. IMPLICATIONS: The quantity of stress during transport to the operating room and the perioperative psychoendocrinologic course of stress in combination with two different methods of preoperative medical information are described in 60 consecutive patients awaiting cardiac surgery.


Subject(s)
Cardiac Surgical Procedures/psychology , Patient Education as Topic , Stress, Physiological/etiology , Stress, Physiological/prevention & control , Aged , Anxiety/etiology , Anxiety/metabolism , Anxiety/prevention & control , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/education , Female , Humans , Hydrocortisone/blood , Hydrocortisone/metabolism , Male , Middle Aged , Pamphlets , Physician-Patient Relations , Salivary Glands/metabolism , Stress, Physiological/metabolism
5.
Eur J Cardiothorac Surg ; 19(6): 797-805, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11404133

ABSTRACT

OBJECTIVES: Left ventricular hypertrophy in patients with critical aortic stenosis (AS) is an adaptive process that compensates for high intracavitary pressure and reduces systolic wall stress followed by an increase in myocardial masses. In the present prospective clinical trial, we investigated long-term compensatory changes in left ventricular geometry and function after aortic valve replacement using mechanical bileaflet prostheses with the main emphasis on the small-sized aortic annulus and valve prosthesis-patient mismatch. METHODS: A total of 58 patients with critical AS were assigned to the following groups according to the predictive value of prosthetic valve area index (VAI): group EXMIS: 29 patients (VAI < or =0.99), expected mismatch; group NOMIS: 29 patients (VAI < or =0.99), no mismatch. At controls T(0) (before operation/operation (OP), T(1) and T(2) (4 and 20 months after OP) the left ventricular geometry was recorded by means of Imatron electron beam tomography and the transprosthetic velocities were measured by echocardiography. RESULTS: Statistical analysis showed a consistent reduction in the absolute (P=0.04) and indexed (P=0.04) left ventricular myocardial mass for both cohorts; furthermore, there was a significant difference between EXMIS and NOMIS patients concerning the factors, time and mass reduction (P=0.005), because of distinct baselines. A logistic regression report revealed preoperative cardiac output, absolute left ventricular myocardial mass, perfusion, body surface area and the native valve orifice area as predicting coefficients and factors for a minimum mass reduction of 25%. We explain a mathematical formula that turned out to be the most sensitive for correctly classified factors. CONCLUSIONS: The left ventricular geometry and transprosthetic velocities resulted in the same postoperative recovery for both EXMIS and NOMIS patients. The presented data showed that valve prosthesis-patient mismatch had no influence in several stepwise logistic regression models. We conclude that modern mechanical bileaflet prostheses allow both acceptable hemodynamics and recovery of left ventricular hypertrophy, even in small aortic annuli.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Heart Ventricles/anatomy & histology , Aged , Body Surface Area , Cardiac Output , Echocardiography , Female , Heart Ventricles/pathology , Humans , Hypertrophy , Male , Models, Theoretical , Prospective Studies , Ventricular Function, Left/physiology
6.
Naunyn Schmiedebergs Arch Pharmacol ; 363(2): 125-32, 2001 Feb.
Article in English | MEDLINE | ID: mdl-11218064

ABSTRACT

The aim of this study was to investigate the effects of the potassium channel openers (PCOs) cromakalim and pinacidil on the ATP-dependent potassium current I(K)(ATP) in human atrial myocytes. Cells were isolated from the right atrial appendage obtained during cardiac surgery. Membrane currents were studied with the patch-clamp technique in the whole-cell recording mode at 36 degrees -37 degrees C. Under physiological conditions (4.3 mmol/l ATP in the pipette solution, ATPi) I(K)(ATP) did not contribute to basal electrical activity. When ATPi was omitted from the pipette solution I(K)(ATP) activated with a time lag of 4.92+/-0.92 min (n=6) and was completely inhibited by glibenclamide. Using 4.3 mmol/l ATPi I(K)(ATP) at +30 mV was increased by 2.04+/-0.51, 7.24+/-1.65 and 13.22+/-3.71 pA/pF (n=7) with 10, 30 and 100 micromol/l cromakalim, respectively, and by 3.24+/-0.98 (n=6), 4.07+/-0.48 (n=10) and 3.46+/-1.23 pA/pF (n=6) with 10, 30 and 100 micromol/l pinacidil, respectively. Control current density was 5.39+/-0.47 pA/pF (n=39). Using 1 mmol/l ATPi I(K)(ATP) showed a more pronounced activation (4.81+/-3.28, n=6; 9.78+/-2.60, n=7; and 15.1+/-4.18 pA/pF, n=6; with 10, 30 and 100 micromol/l pinacidil, respectively). I(K)(ATP) activated by both compounds could be effectively inhibited by glibenclamide. Repetitive exposure to pinacidil (30 micromol/l at 4.3 mmol/l ATPi) caused a potentiation of I(K)(ATP). Current density at +30 mV was increased by 87% during the first and by 401% during the second pinacidil application (n=5). The data presented in this paper provide new information about electrophysiological characteristics of human atrial I(K)(ATP) and its modulation by the PCOs cromakalim and pinacidil and suggest species-dependent differences.


Subject(s)
Adenosine Triphosphate/pharmacology , Cromakalim/pharmacology , Pinacidil/pharmacology , Potassium Channels/drug effects , Vasodilator Agents/pharmacology , Adult , Aged , Female , Glyburide/pharmacology , Heart Atria/cytology , Heart Atria/drug effects , Humans , Hypoglycemic Agents/pharmacology , Male , Middle Aged , Potassium Channels/physiology , Temperature
7.
Article in German | MEDLINE | ID: mdl-11824345

ABSTRACT

The grounds for liability with robotic surgery include damage to patients, causality, illegality and guilt. The patient must receive very comprehensive information on the treatment under consideration, his/her risk and what will be done in the case of technical failure. The surgeon operating the robotic device is obliged to provide normal conscientious care and state-of-the-art treatment. In addition, there is possible neglect of supervisory duties vis-à-vis other hospital personnel to be considered. A special problem is posed by a forensic physician who lacks experience in robotic surgery. There should be a surgeon at the operating table who is at least equally skilled as the surgeon operating the monitor. Robotic surgery must ultimately be at least as effective as conventional surgery, if not better. It must, however, be borne in mind that in cases involving this new technology, it is that patient who is the pioneer.


Subject(s)
Education, Medical, Graduate/legislation & jurisprudence , Informed Consent/legislation & jurisprudence , Malpractice/legislation & jurisprudence , Robotics/education , Thoracic Surgery, Video-Assisted/education , Thoracic Surgery/education , Germany , Humans , Referral and Consultation/legislation & jurisprudence , Robotics/legislation & jurisprudence , Thoracic Surgery/legislation & jurisprudence , Thoracic Surgery, Video-Assisted/legislation & jurisprudence
8.
Herzschrittmacherther Elektrophysiol ; 12(4): 186-94, 2001 Dec.
Article in German | MEDLINE | ID: mdl-27432388

ABSTRACT

Pacing threshold is not a stable value during the pacemaker's life. It is affected by many physiological, pharmacological and pathophysiological factors. A pacing system able to confirm capture and automatically adjust its output to the actual pacing threshold is highly desirable for a prolonged battery life and maximal patient safety. The Autocapture(TM) of St. Jude Medical and the Capture Management(TM) of Medtronic are currently available on the market. The key feature is the measurement of the evoked response (ER) signal by the pacemaker for capture confirmation. In case of loss of capture, the Autocapture(TM) System delivers a back up safety pulse of 4.5 Volt and 0.49 ms and starts a new threshold search. The pacemaker adapts its output to 0.3V/0.25V above the newly measured threshold. This system needs bipolar leads with low polarization for the first generation in Microny® and Regency® pacemakers; in the second generation with Affinity® and Integrity® pacemakers various bipolar leads are suitable. The Capture Management(TM) System of Medtronic, available in the Kappa® DR 700 series, performs a two point automatic threshold search once every day during rest. The output is determined by the programmed safety margin (nominal 1.5×voltage threshold). A backup pulse is only delivered during the threshold search. No special electrodes are necessary. These functions were shown to work safely and efficaciously in multicenter trials to decrease the current consumption with a prolongation of battery life up to 142%. The patients safety was increased by identifying changes of the capture threshold over time and adjusting the pacing stimulus. The conventional safety margins of 100% might not be safe for all patients. We also learned much about lead maturation and lead instability by the possibility of continuous follow-up of threshold changes in a larger group of leads in order to identify the risk group of about 10% of patients with late threshold increase and lead instability.

9.
Gesundheitswesen ; 62(6): 335-41, 2000 Jun.
Article in German | MEDLINE | ID: mdl-10920571

ABSTRACT

UNLABELLED: Due to structural problems of the East German economy the level of unemployment will probably remain high for the next ten years. Thus, thousands of health-employment-schemes are established to reduce negative social and financial consequences of unemployment for those groups that are most affected. In this study the effects of temporary re-employment on health within the bounds of a job-creating measure are examined. By questionnaire employees of two firms in Magdeburg that exclusively occupies former unemployed men and women were asked about their subjective health status and changes in health status since re-employment. 217 employees filled the questionnaire (response rate: 50%; mean age: 45 years, mean duration of former unemployment: 18 months). About one half of the employees (48%) report positive effects on health after re-employment. This percentage is highest in the age group 50 years and older. The frequency of health impairments remained unchanged for half of the workers, the rest mainly stated fewer impairments. Poor working conditions or physical overtaxing decreases the positive effects of re-employment. Employees who had a positive attitude towards their work report on positive effects on health and other aspects of life more than average. CONCLUSIONS: Negative consequences of unemployment on physical and psychological health are well understood. On the other hand, our study demonstrates positive effects on health and a reduction of health impairments by temporary job-creating measures. This is influenced by the working conditions and the social environment of the employees. Further investigation are needed for detailed medical evaluation of job-creating schemes.


Subject(s)
Health Status , Rehabilitation, Vocational/psychology , Unemployment/psychology , Adult , Female , Follow-Up Studies , Germany , Humans , Male , Middle Aged
10.
Ann Thorac Surg ; 69(3): 931-3, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10750789

ABSTRACT

We report a case of a 5-year-old girl who suffered a massive arterial air embolism during surgical closure of an atrial septal defect. The risk of permanent neurologic deficits or even fatal outcome is significant (mortality rate, 31%). We successfully treated a proven arterial air embolism with intraoperative (retrograde cerebral perfusion) combined with postoperative procedures (deep barbiturate anesthesia and hyperbaric oxygenation). At discharge the girl had fully recovered from the initial neurologic defects.


Subject(s)
Embolism, Air/therapy , Heart Septal Defects, Atrial/surgery , Intraoperative Complications/therapy , Child, Preschool , Embolism, Air/etiology , Extracorporeal Circulation/adverse effects , Female , Humans , Intraoperative Complications/etiology , Remission Induction
11.
Wien Med Wochenschr ; 150(19-21): 414-8, 2000.
Article in German | MEDLINE | ID: mdl-11132435

ABSTRACT

From 1990 to 1999, 2,853 ventricular and 1,084 atrial bipolar leads of various manufacturers (Medtronic, Biotronik, Vitatron, Ela, Pacesetter and Stöckert) were implanted during first implantations of pacemakers at the University of Graz, Dept. of Cardiac Surgery. Surgical complications with the need of reintervention were analyzed during a follow up period of up to 10 years. The overall lead-related complication rate for ventricular bipolar leads was 6.5% (187 of 2,853) and 5.3% (58 of 1,084) for atrial bipolar leads. Early complications within the first month were higher in the atrium (5.3% versus 2.2% in the ventricle), primarily due to dislocation, late complications were higher in the ventricle (4.3% versus 2% in the atrium) due to insulation problems and lead fracture. Insulation material had a marked influence with a higher failure rate in some leads with polyurethane insulation compared with silicone. Therefore we recommend a close follow-up of bipolar polyurethane leads by measurement of chronic impedance in order to assess insulation problems as early as possible.


Subject(s)
Electrodes, Implanted , Pacemaker, Artificial , Austria , Equipment Failure Analysis , Follow-Up Studies , Humans
12.
Br J Pharmacol ; 128(6): 1175-80, 1999 Nov.
Article in English | MEDLINE | ID: mdl-10578129

ABSTRACT

1 It was the aim of our study to investigate the effects of the sulphonylurea glibenclamide on voltage dependent potassium currents in human atrial myocytes. 2 The drug blocked a fraction of the quasi steady state current (ramp response) which was activated positive to -20 mV, was sensitive to 4-aminopyridine (500 microM) and was different from the ATP dependent potassium current IK(ATP). 3 Glibenclamide dose dependently inhibited both, the peak as well as the late current elicited by step depolarization positive to -20 mV. The IC50 for reduction in charge area of total outward current was 76 microM. 4 The double-exponential inactivation time-course of the total outward current was accelerated in the presence of glibenclamide with a tau(fast) of 12.7+/-1.5 ms and a tau(slow) of 213+/-25 ms in control and 5.8+/-1.9 ms (P<0.001) and 101+/-20 ms (P<0.05) under glibenclamide (100 microM). 5 Our data suggest, that both repolarizing currents in human atrial myocytes, the transient outward current (Ito1) and the ultrarapid delayed rectifier current (IKur) were inhibited by glibenclamide. 6 In human ventricular myocytes glibenclamide inhibited Ito1 without affecting the late current. 7 Our data suggest that glibenclamide inhibits human voltage dependent cardiac potassium currents at concentrations above 10 microM.


Subject(s)
Glyburide/pharmacology , Heart Atria/drug effects , Heart Ventricles/drug effects , Membrane Potentials/drug effects , Potassium Channels/drug effects , Adenosine Triphosphate/physiology , Atrial Function , Dose-Response Relationship, Drug , Electric Stimulation , Heart Atria/cytology , Heart Ventricles/cytology , Humans , Time Factors , Ventricular Function
13.
Cardiovasc Res ; 43(2): 332-43, 1999 Aug 01.
Article in English | MEDLINE | ID: mdl-10536663

ABSTRACT

OBJECTIVE: It was the aim of our study to describe repolarizing currents in ventricular myocytes isolated from children with tetralogy of Fallot. This is the first report on outward currents in ventricular myocytes from children. METHODS: Ventricular myocytes were isolated from tissue samples of the outflow tract of the right ventricle which were obtained during corrective surgery of tetralogy of Fallot. Action potentials and whole-cell currents were recorded with the patch clamp technique at a temperature of 36-37 degrees C. RESULTS: The mean resting potential was -71.7 +/- 1.92 mV, action potential amplitude was 110 +/- 2.96 mV and action potential duration at 90% repolarization was 794 +/- 99.5 ms (n = 12). In four out of 12 myocytes early afterdepolarizations (EADs) were observed. Upon hyperpolarization Ba(2+)-sensitive inward currents similar to the inward rectifier current (IKl) could be observed. The current density at -120 mV was -22.8 +/- 2.47 pA/pF (n = 14). A transient outward current (Itol) could be recorded in all myocytes studied, the current density varied from 0.3 to 8.6 pA/pF with a mean of 3.77 +/- 0.47 pA/pF at +40 mV (n = 38). Recovery of Itol from inactivation was fast (70% recovery within 100 ms), rate-dependent reduction amounted to 38.2% at 4 Hz. A delayed rectifier current was seen in only two out of 38 myocytes (rapid component IKr). CONCLUSIONS: The electrophysiological characteristics of right ventricular myocytes isolated from children with tetralogy of Fallot resemble in most cases subendocardial myocytes from adults. The most prominent difference is a fast recovery from inactivation as well as a small rate dependent reduction of Itol. The observed EADs may have clinical implications.


Subject(s)
Action Potentials , Heart/physiopathology , Tetralogy of Fallot/physiopathology , Child , Child, Preschool , Heart Ventricles , Humans , Infant , Patch-Clamp Techniques , Sodium-Potassium-Exchanging ATPase
14.
Thorac Cardiovasc Surg ; 47(2): 101-5, 1999 Apr.
Article in English | MEDLINE | ID: mdl-10363609

ABSTRACT

BACKGROUND: We report on results of a prospective clinical trial designed to demonstrate the influence of various strategies in "Total Cavopulmonary Connection" (TCPC) for palliative therapy of patients with "single ventricle" physiology. METHODS: From 1989 to 1997, a total of 47 patients (mean age 4.8 +/- 3.6 years) underwent definitive TCPC at our unit. 31 patients (66%) underwent one-stage TCPC, in 16 patients (34%) we performed a two-stage modified Fontan operation; 21 patients had central fenestration (4 mm). Inhalative NO therapy in the immediate postoperative period was adopted in 1993. RESULTS: Overall 5-year survival was 76.4%, after two-stage TCPC 87.5%, and 81.3% in patients undergoing fenestrated procedures. Two of three patients survived perioperative Fontan take-down. We lost 11 patients (nine early and two late deaths): three patients died primarily because of neurologic dysfunction and eight patients because of cardiac failures. Under perioperative NO therapy there was no early death. After a mean follow-up of 35.9 +/- 23.3 months, 76% of all patients were in NYHA I and 21 % in NYHA I-II. 89.7% had sinus rhythm. 42% of our patients suffered from temporary pleuropericardial effusions. CONCLUSIONS: Definitive palliation with TCPC achieves acceptable clinical results. Two-stage repair, fenestration, and postoperative inhalative NO therapy - each have a positive influence on early and long-term survival.


Subject(s)
Heart Bypass, Right , Heart Defects, Congenital/surgery , Heart Ventricles/abnormalities , Administration, Inhalation , Adolescent , Adult , Cardiopulmonary Bypass , Child , Child, Preschool , Electrocardiography, Ambulatory , Female , Follow-Up Studies , Heart Bypass, Right/methods , Heart Defects, Congenital/mortality , Heart Defects, Congenital/physiopathology , Heart Ventricles/surgery , Hospital Mortality , Humans , Infant , Male , Nitric Oxide/administration & dosage , Nitric Oxide/therapeutic use , Postoperative Complications/mortality , Postoperative Complications/prevention & control , Prospective Studies , Survival Rate , Treatment Outcome , Vasodilator Agents/administration & dosage , Vasodilator Agents/therapeutic use
15.
Ann Thorac Surg ; 67(4): 1001-5, 1999 Apr.
Article in English | MEDLINE | ID: mdl-10320242

ABSTRACT

BACKGROUND: Risk evaluation comparing the minimally invasive and standard aortic valve operations has not been studied. METHODS: Four surgeons were randomly assigned to perform the minimally invasive (L-shaped sternotomy) (group 1) or the conventional (group 2) operation in 120 patients exclusively. RESULTS: In both groups (n = 60) a CarboMedics prothesis was implanted in 90% of patients. There was no significant difference in the cross-clamping period (group 1, 60 minutes; range, 35 to 116 minutes), in the duration of extracorporal circulation (group 1, 84 minutes; range, 51 to 179 minutes) or in the time from skin-to-skin (group 1, 195 minutes; range, 145 to 466 minutes). Patients in group 1 were extubated earlier (p<0.001), the postoperative blood loss was less (p<0.001), and the need for analgesics was reduced (p<0.05). In 5 patients in group 1 a redo operation was required for bleeding (p>0.05), 3 patients in group 1 required a redo operation because of paravalvular leakage or endocarditis (p>0.05), the 30-day mortality rate was 1.6%. Overall the survival rate was 95% in group 1 and 97% in group 2 (mean follow-up, 294 days; range, 30 to 745 days). CONCLUSION: The advantages of minimally invasive aortic valve operation include reduced trauma from incision and duration of ventilation, decreased blood loss and postoperative pain, the avoidance of groin cannulation, and a cosmetically attractive result. Simple equipment is used with a high degree of effectiveness and with no sacrifice of safety. Our study demonstrated the practicability and reliability of this new method.


Subject(s)
Aortic Valve/surgery , Minimally Invasive Surgical Procedures , Adult , Aged , Extracorporeal Circulation , Female , Humans , Male , Middle Aged , Pain, Postoperative/prevention & control , Postoperative Complications , Postoperative Hemorrhage/prevention & control , Prospective Studies , Reoperation , Survival Rate
16.
Pacing Clin Electrophysiol ; 22(3): 531-3, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10192865

ABSTRACT

After twenty-five years of therapy with different unifocal pacemaking systems, an 84-year old male patient developed a nonseptic pacemaker decubitus. A rare incidental finding of invasive ductal carcinoma of the right mammary gland was surgically treated by a generous excision of the tumor and by consecutive modified radical mastectomy. According to published literature, the association of invasive ductal carcinoma arising from a pacemaker pocket decubitus and followed by curative treatment has not been previously reported. We do conclude that pacemaker generators in close relationship to the mammary gland should be considered with suspicion.


Subject(s)
Breast Neoplasms, Male/etiology , Carcinoma, Ductal, Breast/etiology , Pacemaker, Artificial/adverse effects , Ulcer/etiology , Aged , Aged, 80 and over , Breast Neoplasms, Male/pathology , Breast Neoplasms, Male/surgery , Carcinoma, Ductal, Breast/pathology , Carcinoma, Ductal, Breast/surgery , Humans , Male , Mastectomy, Radical
17.
Cardiovasc Res ; 38(2): 424-32, 1998 May.
Article in English | MEDLINE | ID: mdl-9709403

ABSTRACT

OBJECTIVE: The aim was to investigate the electrophysiological properties of the L-type calcium current (ICa,L) in ventricular myocytes at a physiological temperature (36-37 degrees C) isolated from children undergoing surgical repair of tetralogy of Fallot. METHODS: ICa,L was recorded with the patch-clamp technique in the single electrode whose-cell mode at a physiological calcium concentration (1.8 mmol/l) at 36-37 degrees C. RESULTS: Under these conditions, maximum current density averaged -5.80 +/- 0.45 pA/pF. ICa,L showed a bell-shaped current-voltage relationship: the current activated at -37.7 +/- 1.36 mV, peaked at +9.41 +/- 1.60 mV and reversed at +57.7 +/- 2.12 mV (n = 17). At +10 mV, time to peak of ICa,L was 5.23 +/- 0.46 ms. Membrane potentials for half-maximal steady-state activation and inactivation of ICa,L were -6.02 and -20.4 mV, respectively, the slope factors were 7.16 mV for steady-state activation and 6.49 mV for steady-state inactivation. ICa,L did not completely inactivate and showed a big window current between -45 and +40 mV. The inactivation of ICa,L showed a biexponential time course with a fast time constant ranging from 9.11 to 12.9 ms and a slow time constant ranging from 60.9 to 220 ms between -30 and +30 mV. Only the slow time constant showed a pronounced voltage dependency. The recovery from inactivation of ICa,L was biphasic with a fast time constant of 60.7 ms and a slow time constant of 619 ms. beta-Adrenergic stimulation with isoprenaline (1 mumol/l) increased the ICa,L density from -5.71 +/- 1.55 to -13.8 +/- 1.96 pA/pF (142%; P < 0.05) at +10 mV. CONCLUSIONS: The present study demonstrates that most of the electrophysiological properties of ICa,L in ventricular myocytes isolated from children with tetralogy of Fallot resemble those of adult ventricular cells. The existence of a big calcium window current could be involved in the occurrence of early afterdepolarizations which could lead to the high incidence of arrhythmias after surgical repair of tetralogy of Fallot.


Subject(s)
Calcium/metabolism , Myocardium/metabolism , Tetralogy of Fallot/metabolism , Adrenergic beta-Agonists/pharmacology , Biological Transport, Active/drug effects , Child, Preschool , Heart Ventricles , Humans , Ion Transport/drug effects , Isoproterenol/pharmacology , Membrane Potentials/drug effects , Patch-Clamp Techniques
18.
Pflugers Arch ; 436(3): 457-68, 1998 Aug.
Article in English | MEDLINE | ID: mdl-9644230

ABSTRACT

The aim was to investigate outward currents in single, isolated, human, atrial myocytes and to determine the relative contribution of individual current components to the total outward current. Currents were recorded using the whole-cell patch-clamp technique at 36-37 degreesC. Individual outward current components were estimated from recordings of total outward current using a mathematical procedure based on the inactivation time course of the respective currents. This method allows estimation of outward currents without the use of drugs or conditioning voltage-clamp protocols to suppress individual current components. A rapidly activating and partially inactivating total outward current was recorded when myocytes were voltage clamped at potentials positive to -20 mV (peak current density 24. 0+/-0.97 pA/pF at +40 mV; n=107 cells, 33 patients). This total outward current comprised three overlapping currents: a rapidly inactivating, transient, outward current (Ito1) a slowly and partially inactivating current (ultrarapid delayed rectifier, IKur) and a third current component which most probably reflects a non selective cation current (not characterized). The average current densities at +40 mV were 8.92+/-0.44 pA/pF for Ito1 and 15.1+/-0.72 pA/pF for IKur (n=107 cells). Recovery from inactivation was bi-exponential for both currents and was faster for Ito1. A slowly activating delayed rectifier current (IK) was not found. The current densities of peak Ito1 and IKur varied strongly between individual myocytes, even in those from the same patient. The ratio IKur/Ito1 was 0.5-6.9 with a mean of 1.98+/-0.11 (n=107 cells), suggesting that IKur is the main repolarizing current. The amplitudes of the total outward current, Ito1 and IKur, and the ratio of the latter two were independent of patient age (16-87 years).


Subject(s)
Myocardium/cytology , Potassium Channels, Voltage-Gated , Potassium Channels/physiology , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Atrial Function , Delayed Rectifier Potassium Channels , Female , Heart Atria/cytology , Humans , Ion Channel Gating/physiology , Kinetics , Male , Middle Aged , Patch-Clamp Techniques , Temperature
20.
Anesth Analg ; 86(1): 34-9, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9428847

ABSTRACT

UNLABELLED: Criteria for ischemic changes in the esophageal electrocardiograph (E-ECG) have not been standardized and validated. The main goal of this study was to evaluate the experimental esophageal recording of myocardial ischemia and to assess the association between ST segment alternans in the E-ECG and ischemia. Experiments were performed on 18 anesthetized sheep with occlusion of a branch of the left anterior descending artery. The bipolar signals were recorded via an esophageal lead containing three chloridized silver electrodes. Electrical signals were amplified in a self-designed, battery-supported preamplifier (gain 1000, frequency range 0.01-2000 Hz, common mode rejection 140 dB, signal noise 5-7 microV p-p), then sent to a digital oscilloscope for display and to a pulse code-modulated recorder. Surface electrocardiography (S-ECG) data were also recorded. Ischemia E-ECG revealed homogenous ST segments without any beat-to-beat alternans. Two minutes after occlusion, 14 of 15 sheep (93%) showed repetitive beat-to-beat fluctuations within the ST segment on the E-ECG. Of the 15 sheep, 7 (47%) showed ischemia in the S-ECG (P < 0.01). For calculation of the dynamic changes in the ST segment in the E-ECG, the difference in the amplitudes of the ST segment of five successive beats to the next beat, performed for 200 consecutive beats, was calculated. The central tendency of the sum of these values before versus during ischemia was 2000 mV/ms versus 5000 mV/ms (Hodges-Lehmann point estimator) (95% confidence intervals 1700/2500 versus 3350/9250 [lower limit/upper limit]). The authors have established a close temporal relationship between the magnitude of ST segment alternans recorded via E-ECG and myocardial ischemia. IMPLICATIONS: The study presents the use of an esophageal electrocardiograph for detection of progressive changes of myocardial ischemia and infarction. During acute myocardial ischemia and infarction in sheep, the esophageal electrocardiograph has visually apparent ST alternans of amplitude in the millivolt range, in part due to a special amplifier (0.01-2000 Hz). This is therefore one very promising technique for better evaluation of electrocardiographic changes of ischemia.


Subject(s)
Electrocardiography/methods , Myocardial Ischemia/diagnosis , Animals , Esophagus , Female , Male , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL
...