Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Ann Thorac Surg ; 69(3): 931-3, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10750789

ABSTRACT

We report a case of a 5-year-old girl who suffered a massive arterial air embolism during surgical closure of an atrial septal defect. The risk of permanent neurologic deficits or even fatal outcome is significant (mortality rate, 31%). We successfully treated a proven arterial air embolism with intraoperative (retrograde cerebral perfusion) combined with postoperative procedures (deep barbiturate anesthesia and hyperbaric oxygenation). At discharge the girl had fully recovered from the initial neurologic defects.


Subject(s)
Embolism, Air/therapy , Heart Septal Defects, Atrial/surgery , Intraoperative Complications/therapy , Child, Preschool , Embolism, Air/etiology , Extracorporeal Circulation/adverse effects , Female , Humans , Intraoperative Complications/etiology , Remission Induction
2.
Ann Thorac Surg ; 67(4): 1001-5, 1999 Apr.
Article in English | MEDLINE | ID: mdl-10320242

ABSTRACT

BACKGROUND: Risk evaluation comparing the minimally invasive and standard aortic valve operations has not been studied. METHODS: Four surgeons were randomly assigned to perform the minimally invasive (L-shaped sternotomy) (group 1) or the conventional (group 2) operation in 120 patients exclusively. RESULTS: In both groups (n = 60) a CarboMedics prothesis was implanted in 90% of patients. There was no significant difference in the cross-clamping period (group 1, 60 minutes; range, 35 to 116 minutes), in the duration of extracorporal circulation (group 1, 84 minutes; range, 51 to 179 minutes) or in the time from skin-to-skin (group 1, 195 minutes; range, 145 to 466 minutes). Patients in group 1 were extubated earlier (p<0.001), the postoperative blood loss was less (p<0.001), and the need for analgesics was reduced (p<0.05). In 5 patients in group 1 a redo operation was required for bleeding (p>0.05), 3 patients in group 1 required a redo operation because of paravalvular leakage or endocarditis (p>0.05), the 30-day mortality rate was 1.6%. Overall the survival rate was 95% in group 1 and 97% in group 2 (mean follow-up, 294 days; range, 30 to 745 days). CONCLUSION: The advantages of minimally invasive aortic valve operation include reduced trauma from incision and duration of ventilation, decreased blood loss and postoperative pain, the avoidance of groin cannulation, and a cosmetically attractive result. Simple equipment is used with a high degree of effectiveness and with no sacrifice of safety. Our study demonstrated the practicability and reliability of this new method.


Subject(s)
Aortic Valve/surgery , Minimally Invasive Surgical Procedures , Adult , Aged , Extracorporeal Circulation , Female , Humans , Male , Middle Aged , Pain, Postoperative/prevention & control , Postoperative Complications , Postoperative Hemorrhage/prevention & control , Prospective Studies , Reoperation , Survival Rate
3.
Anesth Analg ; 86(1): 34-9, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9428847

ABSTRACT

UNLABELLED: Criteria for ischemic changes in the esophageal electrocardiograph (E-ECG) have not been standardized and validated. The main goal of this study was to evaluate the experimental esophageal recording of myocardial ischemia and to assess the association between ST segment alternans in the E-ECG and ischemia. Experiments were performed on 18 anesthetized sheep with occlusion of a branch of the left anterior descending artery. The bipolar signals were recorded via an esophageal lead containing three chloridized silver electrodes. Electrical signals were amplified in a self-designed, battery-supported preamplifier (gain 1000, frequency range 0.01-2000 Hz, common mode rejection 140 dB, signal noise 5-7 microV p-p), then sent to a digital oscilloscope for display and to a pulse code-modulated recorder. Surface electrocardiography (S-ECG) data were also recorded. Ischemia E-ECG revealed homogenous ST segments without any beat-to-beat alternans. Two minutes after occlusion, 14 of 15 sheep (93%) showed repetitive beat-to-beat fluctuations within the ST segment on the E-ECG. Of the 15 sheep, 7 (47%) showed ischemia in the S-ECG (P < 0.01). For calculation of the dynamic changes in the ST segment in the E-ECG, the difference in the amplitudes of the ST segment of five successive beats to the next beat, performed for 200 consecutive beats, was calculated. The central tendency of the sum of these values before versus during ischemia was 2000 mV/ms versus 5000 mV/ms (Hodges-Lehmann point estimator) (95% confidence intervals 1700/2500 versus 3350/9250 [lower limit/upper limit]). The authors have established a close temporal relationship between the magnitude of ST segment alternans recorded via E-ECG and myocardial ischemia. IMPLICATIONS: The study presents the use of an esophageal electrocardiograph for detection of progressive changes of myocardial ischemia and infarction. During acute myocardial ischemia and infarction in sheep, the esophageal electrocardiograph has visually apparent ST alternans of amplitude in the millivolt range, in part due to a special amplifier (0.01-2000 Hz). This is therefore one very promising technique for better evaluation of electrocardiographic changes of ischemia.


Subject(s)
Electrocardiography/methods , Myocardial Ischemia/diagnosis , Animals , Esophagus , Female , Male , Sheep
4.
Eur J Cardiothorac Surg ; 7(3): 114-6, 1993.
Article in English | MEDLINE | ID: mdl-8384861

ABSTRACT

Six years after the first aortic valve replacement with the Starr-Edwards Silastic ball prosthesis at Oregon Health Sciences University, the model 1260 was implanted in a 44-year-old patient at our department. During 24 years no signs of dysfunction, thromboembolism, thrombosis, periprosthetic leaks or hemolysis were observed. Material test showed no signs of fatigue. The dimension of the Silastic poppet was found to be one millimeter less than the original specifications of these poppets and there were some lipid infiltrations. Functionally the poppet was found to be nonvariant. Histologic findings detected focal hyalinization and giant cells without signs of acute inflammation or ulceration. With regard to its reliability and durability, the Starr-Edwards valve prosthesis should not be viewed with disfavor.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Adult , Aortic Valve Stenosis/rehabilitation , Evaluation Studies as Topic , Follow-Up Studies , Foreign-Body Reaction/etiology , Heart Valve Diseases/complications , Heart Valve Diseases/surgery , Heart Valve Prosthesis/adverse effects , Hemodynamics , Humans , Male , Silicone Elastomers , Silicones